AccuForce 12V - 150Ah | VRLA Battery Specifications Nominal Voltage Number of cells Design Life Dimensions Approx. Weight Nominal Capacity (25ºC) Max. Discharge Current (25ºC) Internal Resistance Fully Charged battery (25ºC) Self-Discharge Applications 12 V 6 10 years Length Width Height Total Height 42.8 kg 20 hours rate (7.88 A, 10.8 V) 10 hours rate (15.00 A, 10.8 V) 5 hours rate (26.30 A, 10.5 V) 1 hour rate (93.00 A, 9.6 V) 1200 A (5s) 485 mm 172 mm 240 mm 240 mm 157.6 Ah 150.0 Ah 131.5 Ah 93.0 Ah 3.5 mOhms 3% of capacity declined per month at 20ºC (average) Discharge : -15ºC~50ºC Operating Temperature Range Charge : -10ºC~50ºC Storage : -20ºC~50ºC Short Circuit Current 4120 A Cycle use 2.40-2.45 Vpc Maximum charging current 45 A Charge Methods: Temperature compensation -30 mV/ºC Constant Voltage Charge (25ºC) Standby use 2.23-2.27 Vpc Temperature compensation -18 mV/ºC • Uninterruptible Power Supplies (UPS) • Electric Power Systems (EPS) • Emergency backup power supplies • Electronic apparatus and equipment • Communication power supplies • DC power supplies • Auto control system Battery Construction Component Raw material Positive Plate Lead dioxide Negative Plate Lead Container ABS Cover ABS Safety Valve Rubber Terminal Copper Separator Fiberglass Electrolyte Sulfuric acid Dimensions 485±2 172±2 16 240±2 3 M8 M8 Constant Current Discharge (Amperes) at 25ºC End Voltage (Volts/Cell) 1.60 V 1.65 V 1.70 V 1.75 V 1.80 V 15min 248 242 233 225 213 30min 150 147 143 139 134 1h 93.0 91.6 89.3 87.5 84.8 2h 54.8 54.5 54.0 53.2 51.8 3h 38.3 38.0 37.8 37.5 36.4 4h 31.4 31.2 31.0 30.8 29.8 5h 26.8 26.6 26.4 26.3 25.5 6h 23.4 23.3 23.1 23.0 22.3 8h 18.4 18.3 18.1 18.0 17.5 10h 15.3 15.2 15.2 15.1 15.0 20h 8.02 8.00 7.98 7.93 7.88 6h 277 275 273 271 263 8h 218 217 215 214 207 10h 182 182 181 180 179 20h 96.2 96.0 95.7 95.2 94.5 Constant Power Discharge (Watts) at 25ºC End Voltage (Volts/Cell) 1.60 V 1.65 V 1.70 V 1.75 V 1.80 V 15min 2718 2652 2554 2468 2337 30min 1683 1649 1599 1560 1503 1h 1060 1044 1018 998 967 2h 635 631 625 616 600 3h 450 447 444 441 428 4h 369 367 364 362 351 5h 316 315 312 310 301 (Note) The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. www.systems-sunlight.com AccuForce 12V - 150Ah | VRLA Battery Self Discharge Characteristics Temperature Effects on Float Life 15 110 90 Capacity (%) Life (years) 100 2.30V/Cell 10 5 80 70 60 o C o C o C 50 0 10 20 30 40 50 40 Temperature (ºC) 0 2 Charged Volume Current (% ) Battery Voltage (V) 13.0 12.0 120 11.0 100 10.0 80 9.00 60 8.00 40 2 3 5 20 30 10 60 2 3 5 10 20 30 H Min 8 10 12 14 Storage Time (Months) 16 18 20 Voltage (V ) (C A ) 140 0 1 6 Constant Voltage Charging Characteristic (0.25 CA, 25ºC) Discharge Characteristics (25ºC) 7.00 4 1. 2. 3. 4. 0.25 0.20 0.15 0.10 20 0.05 0 0 15.0 Discharge:100% Charge voltage:2.40V/cell Charge current:0.20C(A) Temperature:25°C Charge Voltage 14.0 13.0 Charging Current 12.0 0 2 4 6 8 10 12 14 Charging Time (hours) Discharge Time Relationship Between Charging Voltage and Temperature Charged Volume 16 18 20 Relationship Between OCV and Residual Capacity (25ºC) 14.00 Open Circuit Voltage (V) Battery Voltage (V) 12V 15.6 13.00 15.0 Cycle 14.4 Stand Use 12.00 by Us 13.8 e 11.00 13.2 -10 0 10 20 30 40 50 60 10.00 Ambient Temperature (ºC) 0 Cycle Service Life in Relation to Depth of Discharge 20 40 60 80 Residual Capacity(%) 100 Temperature Effects on Capacity 120 0.05 C 0.1C Capacity (%) Capacity (%) 100 C 0.25 1.0C 80 60 3.0 C 40 20 0 -20 Number of Cycles (Cycles) -10 0 10 20 30 40 50 Temperature (ºC) SYSTEMS SUNLIGHT S.A. Headquarters 2 Ermou & Nikis Str., Syntagma Sq. 105 63 Athens, Attica, Greece T +30 210 6245400 F +30 210 6245409 European Manufacturing Plant 672 00 Íeo Olvio, Xanthi, Greece T +30 25410 48100 F +30 25410 95446 Global Service Department 90 Tatoiou Str. 136 73 Acharnes, Áttica, Greece T +30 210 6245600 F +30 210 6245619 www.systems-sunlight.com
© Copyright 2026 Paperzz