THE ENCLAVE at RIVERFRONT LIVING REFLECTED CEILING PLAN SYMBOLS 2'-0" x 2'-0" SUSPENDED ACOUSTICAL CEILING PANELS 1 x 4 RECESSED LIGHT FIXTURE GYPSUM BOARD SOFFIT / CEILING OR E.I.F.S ON EXTERIOR GYP. BD. CEILING MOUNTED PROJECTOR 2 x 4 LENS LIGHT FIXTURE EXIT FIXTURE Riverfront JAM LLC WALL MOUNTED LIGHT FIXTURE 8' FLUORESCENT SHOP LIGHT 0'-0" FINISH HEIGHT OF CEILING / SOFFIT A.F.F. 4' FLUORESCENT SHOP LIGHT HVAC RETURN AIR RECESSED CAN LIGHT FIXTURE WALL MOUNT EXTERIOR LIGHT FIXTURE PENDANT LIGHT FIXTURE HVAC SUPPLY DIFFUSER EJ OCCUPANCY SENSOR EXPANSION JOINT 101 FREDERICA ST. OWENSBORO, KENTUCKY 42303 WALL MNT FIXTURE GENERAL REFLECTED CEILING PLAN NOTES: 1. CEILING AND SOFFIT HEIGHTS ARE NOTED FROM THEIR RESPECTIVE FLOOR ELEVATIONS. 2. PROVIDE CONTROL JOINTS OR OTHER ISOLATION MEANS IN GYPSUM BOARD PANELS WHERE (A) PARTITION, FURRING, SOFFIT, BULKHEAD OR CEILING, (B) CONSTRUCTION CHANGED WITHIN PLANE OF PARTITION OR CEILING, (C) PARTITION, FURRING, SOFFIT, BULKHEAD OR CEILING RUN EXCEEDS 30'-0", (D) AS NOTED. 3. BULKHEADS SHALL BE DIAGONALLY BRACED TO FLOOR DECK WITH METAL STUDS AT 4'-0" O.C. MINIMUM. 4. REFER TO LIFE SAFETY PLANS FOR LOCATION OF RATED FLOOR/CEILING ASSEMBLIES. 5. INDICATES SOUND ATTENUATION BLANKETS WITH GYPSUM BOARD ON ONE SIDE OF PARTITION TO UNDERSIDE OF ROOF STRUCTURE ABOVE. 6. 7. 8. In association with: Owner Riverfront JAM LLC GYPSUM BOARD WALLS NOT REQUIRED TO EXTEND TO BOTTOM OF STRUCTURE ABOVE SHALL TERMINATE 6" ABOVE THE HIGHEST ADJOINING CEILING AND SHALL BE BRACED EITHER BY ATTACHING ALTERNATING DIAGONAL STUDS 48" O.C. FROM TOP OF WALL TO ROOF STRUCTURE OR BY EXTENDING WALL STUDS TO ROOF STRUCTURE ABOVE. 2960 Fairview Drive Owensboro, KY 42303 UNLESS NOTED OTHERWISE AT SUSPENDED EXTERIOR SYNTHETIC STUCCO CEILING SYSTEMS INSTALL STRUTS (MIN. 1 1/2" CHANNEL MATERIAL) AT MINIMUM 4'-0" O.C. SPANNING BETWEEN THE CARRYING CHANNELS AT THE STRUCTURE ABOVE SECURELY ANCHORED AT BOTH ENDS TO RESIST UPLIFT FORCES. ENVISION CONTRACTORS LLC 2960 Fairview Drive Owensboro, KY 42303 MINIMUM DISTANCE FROM EDGE OF WALL TO SUSPENDED CEILING TILE GRID SHALL BE 6" Telephone: 270.689.1733 Facsimile: 270.689.2226 SUSPENDED CEILING SEISMIC DESIGN NOTES: TED LOLLEY & ASSOCIATES professional engineers SEISMIC DESIGN CATEGORY C - PROVIDE PER ASTM C635 / C636, AND THE FOLLOWING SEISMIC REQUIREMENTS: A. INTERMEDIATE-DUTY GRID SYSTEM. (UNLESS SPECIFIED AS HEAVY-DUTY) B. 7/8" WALL MOLDING. C. ATTACHED GRID TO TWO ADJACENT WALLS WITH SEISMIC CLIPS AND SET SCREWS; OPPOSITE WALLS ATTACHED WITH SEISMIC CLIPS (NO SET SCREW) WITH 3/8" CLEARANCE. D. MINIMUM 3/8" OVERLAP OF GRID ON THE WALL MOLDING. E. SEISMIC CODE COMPLIANT CLIPS ON ALL MAIN RUNNERS. F. SAFETY WIRES ON ALL LIGHT FIXTURE CORNERS. 309 East 4th Street Owensboro, KY 42303 Ph. (270) 683-2270 Fax: (270) 9264323 Web: www.lolley.com Email: [email protected] REFLECTED CEILING PLAN REFERENCE NOTES: 4 A10.1 1 RECESSED, CONTINUOUS LED LIGHT. SEE ELECTRICAL DRAWINGS. 2 NO CEILING, NO FINISH THIS ROOM. EXPOSED STRUCTURE. SEE ELECTRICAL DRAWING FOR NUMBER TYPE AND PLACEMENT OF FIXTURES 3 NO CEILING. DRY FALL PAINT FINISH THIS ROOM. EXPOSED STRUCTURE. ALL EXPOSED CONSTRUCTION INCLUDING STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND OTHER MISC. ITEMS SHALL BE PAINTED. 4 CLOUD CEILINGS THIS ROOM. AT THE AREA BETWEEN CLOUDS, DRY FALL PAINT ALL ELEMENTS AS NOTED ABOVE SO THAT NO UNFINISHED CONSTRUCTION IS VISIBLE FROM ANY ANGLE BELOW. 5 UNISTRUT GRID SUSPENDED AT 11'-6" A.F.F. PAINT TO MATCH COLOR SELECTED FOR DRY FALL PAINT ABOVE. SEE ELECTRICAL DRAWINGS FOR NUMBER, TYPE AND PLACEMENT OF ELECTRICAL FIXTURES AND DEVICES. 6 AT WALLS AND COLUMN SURROUNDS THIS ROOM, PROVIDE A GYPSUM BOARD EXPANSION JOINT AT 11'-6" A.F.F. PAINT ABOVE THE JOINT SHALL MATCH COLOR SELECTED FOR DRY FALL PAINT. SEE INTERIOR DRAWINGS FOR PAINT COLOR SELECTED FOR WALLS BELOW THE EXPANSION JOINT. NOTE THAT ALL WALLS AND COLUMN SURROUNDS EXTEND TO DECK ABOVE. 7 GYPSUM BOARD SOFFIT, 11'-6" A.F.F. TO DECK ABOVE. PAINT OUTER FACE TO MATCH COLOR OF DRY FALL PAINT. SEE INTERIOR DRAWINGS FOR PAINT COLOR SELECTED. 8 FACE OF SOFFIT EXTENDS TO DECK ABOVE. SEE FINISH REQUIREMENTS, NOTE 6 ABOVE. 9 SUSPENDED CLOUD CEILING. FURNISH 6" AXIOM VERTICAL TRIM AT PERIMETER. 10 2' x 2' ACCESS PANEL. LOCATE HVAC UNITS ABOVE PANELS. 11 WOOD PLANK CEILING. SEE DETAILS. 12 METAL PANEL CEILING / SOFFIT. SEE DETAILS. 13 EXPOSED STRUCTURE AND DECK AT OUTDOOR STAGE, PAINT. 14 METAL COLUMN COVER. FURNISH WITH FRY-REGLET COLLAR AT SOFFIT. 15 RETURN AIR PATHWAYS. NO FINISH. 16 REINFORCED GYPSUM BOARD COLUMN COVER. FURNISH WITH FRY-REGLET COLLAR AT CEILING / SOFFIT. 17 SUSPENDED METAL CLOUDS. 18 ACCESS LADDER 19 LOCATE MOTOR ATTACHMENT POINTS TO ALIGN WITH GAPS BETWEEN CLOUD CEILINGS, SEE STRUCTURAL AND CLAIR DRAWINGS. 20 STRUCTURAL HANGERS FOR LOCATION OF SUSPENDED SPEAKERS, SEE STRUCTURAL AND CLAIR DRAWINGS. 11/15/16 Revisions: # Description Designed By: Drawn By: Sheet title: REFLECTED CEILING PLAN FIRST FLOOR, NOTES, LEGEND AND DETAILS 1602-138 REFLECTED CEILING PLAN - FIRST FLOOR Checked By: The drawings, specifications and other documents, including those in electronic form prepared by Hafer for this project are instruments of Service, and may be used solely with respect to this project. The documents may not be reproduced or modified by a third party without first obtaining the express written consent of Hafer. Authorized use of electronic media or file does not guarantee that these files contain complete and accurate information. In order to insure the accuracy of the information contained and that no changes or modifications have been made, these files must be compared to the project's contract documents with stamped and sealed certification and applicable approved modifications. Architect's Project No: 1 Date Date: NOV. 2016 Drawing No: 1/8" = 1'-0" A2.1
© Copyright 2026 Paperzz