G:\1Projects\JAM Development\1602

THE ENCLAVE
at
RIVERFRONT LIVING
REFLECTED CEILING PLAN SYMBOLS
2'-0" x 2'-0" SUSPENDED
ACOUSTICAL CEILING PANELS
1 x 4 RECESSED LIGHT FIXTURE
GYPSUM BOARD SOFFIT / CEILING
OR E.I.F.S ON EXTERIOR GYP. BD.
CEILING MOUNTED PROJECTOR
2 x 4 LENS LIGHT FIXTURE
EXIT FIXTURE
Riverfront
JAM LLC
WALL MOUNTED LIGHT FIXTURE
8' FLUORESCENT SHOP LIGHT
0'-0"
FINISH HEIGHT OF CEILING / SOFFIT A.F.F.
4' FLUORESCENT SHOP LIGHT
HVAC RETURN AIR
RECESSED CAN LIGHT FIXTURE
WALL MOUNT EXTERIOR
LIGHT FIXTURE
PENDANT LIGHT FIXTURE
HVAC SUPPLY DIFFUSER
EJ
OCCUPANCY SENSOR
EXPANSION JOINT
101 FREDERICA ST.
OWENSBORO, KENTUCKY 42303
WALL MNT FIXTURE
GENERAL REFLECTED CEILING PLAN NOTES:
1.
CEILING AND SOFFIT HEIGHTS ARE NOTED FROM THEIR RESPECTIVE FLOOR
ELEVATIONS.
2.
PROVIDE CONTROL JOINTS OR OTHER ISOLATION MEANS IN GYPSUM BOARD
PANELS WHERE (A) PARTITION, FURRING, SOFFIT, BULKHEAD OR CEILING, (B)
CONSTRUCTION CHANGED WITHIN PLANE OF PARTITION OR CEILING, (C)
PARTITION, FURRING, SOFFIT, BULKHEAD OR CEILING RUN EXCEEDS 30'-0",
(D) AS NOTED.
3.
BULKHEADS SHALL BE DIAGONALLY BRACED TO FLOOR DECK WITH METAL
STUDS AT 4'-0" O.C. MINIMUM.
4.
REFER TO LIFE SAFETY PLANS FOR LOCATION OF RATED FLOOR/CEILING
ASSEMBLIES.
5.
INDICATES SOUND ATTENUATION BLANKETS WITH
GYPSUM BOARD ON ONE SIDE OF PARTITION TO UNDERSIDE OF ROOF
STRUCTURE ABOVE.
6.
7.
8.
In association with:
Owner
Riverfront JAM LLC
GYPSUM BOARD WALLS NOT REQUIRED TO EXTEND TO BOTTOM OF
STRUCTURE ABOVE SHALL TERMINATE 6" ABOVE THE HIGHEST ADJOINING
CEILING AND SHALL BE BRACED EITHER BY ATTACHING ALTERNATING DIAGONAL
STUDS 48" O.C. FROM TOP OF WALL TO ROOF STRUCTURE OR BY EXTENDING
WALL STUDS TO ROOF STRUCTURE ABOVE.
2960 Fairview Drive
Owensboro, KY 42303
UNLESS NOTED OTHERWISE AT SUSPENDED EXTERIOR SYNTHETIC STUCCO
CEILING SYSTEMS INSTALL STRUTS (MIN. 1 1/2" CHANNEL MATERIAL) AT MINIMUM
4'-0" O.C. SPANNING BETWEEN THE CARRYING CHANNELS AT THE STRUCTURE
ABOVE SECURELY ANCHORED AT BOTH ENDS TO RESIST UPLIFT FORCES.
ENVISION CONTRACTORS LLC
2960 Fairview Drive
Owensboro, KY 42303
MINIMUM DISTANCE FROM EDGE OF WALL TO SUSPENDED CEILING TILE GRID
SHALL BE 6"
Telephone: 270.689.1733
Facsimile: 270.689.2226
SUSPENDED CEILING SEISMIC DESIGN NOTES:
TED LOLLEY & ASSOCIATES
professional engineers
SEISMIC DESIGN CATEGORY C - PROVIDE PER ASTM C635 / C636, AND THE FOLLOWING
SEISMIC REQUIREMENTS:
A. INTERMEDIATE-DUTY GRID SYSTEM. (UNLESS SPECIFIED AS HEAVY-DUTY)
B. 7/8" WALL MOLDING.
C. ATTACHED GRID TO TWO ADJACENT WALLS WITH SEISMIC CLIPS AND SET
SCREWS; OPPOSITE WALLS ATTACHED WITH SEISMIC CLIPS (NO SET SCREW) WITH
3/8" CLEARANCE.
D. MINIMUM 3/8" OVERLAP OF GRID ON THE WALL MOLDING.
E. SEISMIC CODE COMPLIANT CLIPS ON ALL MAIN RUNNERS.
F. SAFETY WIRES ON ALL LIGHT FIXTURE CORNERS.
309 East 4th Street Owensboro, KY 42303
Ph. (270) 683-2270
Fax: (270) 9264323
Web: www.lolley.com
Email: [email protected]
REFLECTED CEILING PLAN REFERENCE NOTES:
4
A10.1
1
RECESSED, CONTINUOUS LED LIGHT. SEE ELECTRICAL DRAWINGS.
2
NO CEILING, NO FINISH THIS ROOM. EXPOSED STRUCTURE. SEE ELECTRICAL DRAWING
FOR NUMBER TYPE AND PLACEMENT OF FIXTURES
3
NO CEILING. DRY FALL PAINT FINISH THIS ROOM. EXPOSED STRUCTURE. ALL EXPOSED
CONSTRUCTION INCLUDING STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING, FIRE
PROTECTION AND OTHER MISC. ITEMS SHALL BE PAINTED.
4
CLOUD CEILINGS THIS ROOM. AT THE AREA BETWEEN CLOUDS, DRY FALL PAINT ALL
ELEMENTS AS NOTED ABOVE SO THAT NO UNFINISHED CONSTRUCTION IS VISIBLE
FROM ANY ANGLE BELOW.
5
UNISTRUT GRID SUSPENDED AT 11'-6" A.F.F. PAINT TO MATCH COLOR SELECTED FOR
DRY FALL PAINT ABOVE. SEE ELECTRICAL DRAWINGS FOR NUMBER, TYPE AND
PLACEMENT OF ELECTRICAL FIXTURES AND DEVICES.
6
AT WALLS AND COLUMN SURROUNDS THIS ROOM, PROVIDE A GYPSUM BOARD
EXPANSION JOINT AT 11'-6" A.F.F. PAINT ABOVE THE JOINT SHALL MATCH COLOR
SELECTED FOR DRY FALL PAINT. SEE INTERIOR DRAWINGS FOR PAINT COLOR SELECTED
FOR WALLS BELOW THE EXPANSION JOINT. NOTE THAT ALL WALLS AND COLUMN
SURROUNDS EXTEND TO DECK ABOVE.
7
GYPSUM BOARD SOFFIT, 11'-6" A.F.F. TO DECK ABOVE. PAINT OUTER FACE TO MATCH
COLOR OF DRY FALL PAINT. SEE INTERIOR DRAWINGS FOR PAINT COLOR SELECTED.
8
FACE OF SOFFIT EXTENDS TO DECK ABOVE. SEE FINISH REQUIREMENTS, NOTE 6
ABOVE.
9
SUSPENDED CLOUD CEILING. FURNISH 6" AXIOM VERTICAL TRIM AT PERIMETER.
10
2' x 2' ACCESS PANEL. LOCATE HVAC UNITS ABOVE PANELS.
11
WOOD PLANK CEILING. SEE DETAILS.
12
METAL PANEL CEILING / SOFFIT. SEE DETAILS.
13
EXPOSED STRUCTURE AND DECK AT OUTDOOR STAGE, PAINT.
14
METAL COLUMN COVER. FURNISH WITH FRY-REGLET COLLAR AT SOFFIT.
15
RETURN AIR PATHWAYS. NO FINISH.
16
REINFORCED GYPSUM BOARD COLUMN COVER. FURNISH WITH FRY-REGLET COLLAR
AT CEILING / SOFFIT.
17
SUSPENDED METAL CLOUDS.
18
ACCESS LADDER
19
LOCATE MOTOR ATTACHMENT POINTS TO ALIGN WITH GAPS BETWEEN CLOUD
CEILINGS, SEE STRUCTURAL AND CLAIR DRAWINGS.
20
STRUCTURAL HANGERS FOR LOCATION OF SUSPENDED SPEAKERS, SEE
STRUCTURAL AND CLAIR DRAWINGS.
11/15/16
Revisions:
#
Description
Designed By:
Drawn By:
Sheet title:
REFLECTED CEILING PLAN FIRST FLOOR, NOTES,
LEGEND AND DETAILS
1602-138
REFLECTED CEILING PLAN - FIRST FLOOR
Checked By:
The drawings, specifications and other documents, including those in electronic
form prepared by Hafer for this project are instruments of Service, and may be
used solely with respect to this project. The documents may not be reproduced
or modified by a third party without first obtaining the express written consent of
Hafer. Authorized use of electronic media or file does not guarantee that these
files contain complete and accurate information. In order to insure the accuracy
of the information contained and that no changes or modifications have been
made, these files must be compared to the project's contract documents with
stamped and sealed certification and applicable approved modifications.
Architect's Project No:
1
Date
Date:
NOV. 2016
Drawing No:
1/8" = 1'-0"
A2.1