COUNTY OF LOS ANGELES SPECIFICATIONS For Olive View-UCLA Medical Center Solicitation # RFB-IS-15200973 Date: March 16, 2015 For:Monitoring System - Hemodynamic Requisition #:RQN-HO-15024003 BIDDER TO COMPLETE THE FOLLOWING INFORMATION Company Name: __________________________________________________________________________ Address: ________________________________________________________________________________ Contact Person: __________________________________________________________________________ Telephone No: ________________________________ Fax No: ___________________________________ Notice: Bidder shall state in right hand column wherein your product offered differs, indicating performance, specific Size, and/or make and model of all components when not exactly as specified. When bidder is bidding items exactly as described in the left hand column, please state “AS SPECIFIED” on the right hand column. Failure to return and fill in this form will be considered sufficient reason for rejection of your offer. Literature alone is not sufficient for consideration of your offer. All equipment must meet California and County of Los Angeles safety requirements. The equipment shall be the latest model and shall not have been used as a demonstrator. Bidders shall submit detailed literature on the unit they propose to furnish. 1 SPECIFICATION BIDDER’S RESPONSE Hemodynamic Monitoring System to measure cardiac output (CO) and oximetry (ScvO2/SvO2) with CO sensors and oximetry catheters OR EQUAL: I. Physical and Mechanical Specifications Monitor Weight: 2.1 kg (4.6 lbs.) Dimensions : Height 226 mm Width 296 mm Depth 58.6 mm Display : Active Area 257 mm (10.4”) Resolution 800 x 600 LCD Operating System: Windows XPe Speaker count: 2 Databox Weight: 0.9 kg (2.0 lbs.) Dimensions: Height 145 mm Width 206 mm Depth 64 mm II. Environmental Specifications - Platform / Value Operating temperature: 0 to 37 °C Storage Temperature: -25 to 70 °C Relative Humidity, Operation: Up to 95% RH maximum at 45° C (113° F) Relative Humidity, Storage: Up to 95% RH maximum at 60° C (140° F) Altitude, Operation: 0 meter to 3,048 meter (10,000 ft.) Altitude, Storage: -396 meter (-1,300ft) to 6,096 meter (40,000 ft.) III. Base Parameters CO: 2 Diplay Range: 1.0 to 20.0 L/min Reproducibility1: ±6% or 0.1 L/min, whichever is greater Update Rate: 20 seconds (arterial pressure based) or intermittent (TPTD) GEDV: Display Range: 0 to 5000 mL Reproducibility:1 ±6% or 4 mL, whichever is greater Update Rate: Intermittent (TPTD) EVLW: Display Range: 0 to 5000 mL Reproducibility:1: ±6% or 4 mL, whichever is greater Update Rate: Intermittent (TPTD) Note: 1Coefficient of variation - measured using electronically generated data IV. Oximetry - Parameter/ Specification ScvO2/SvO2 Oximetry (Oxygen Saturation): Range: 0 to 99% Precision1: ±2% at 30 to 99% Update Rate: 2 seconds Note: 1 Precision tested under laboratory conditions V. TPTD – Parameter/ Specification Blood Temperature: Range: 15 to 45 °C Accuracy:2 ±0.3 °C Injectate Temperature: Range: 0 to 30 °C Accuracy: 2 ±1.05 °C Note: 2 Accuracy tested under laboratory conditions. VI. Other Parameters - Parameter / Specification PR: Update Rate: Averaged over 20 seconds VII. In vivo Calibration ScvO2/SvO2/HGB/Hct Ranges and Defaults by: Parameter / Selection Range / Defaults – Last Calibration Procedure Completed by: None (Factory) / In vitro / In vivo / Recall / HGB Update 3 Parameter ScvO2/SvO2 : Selection Range: 0.0 to 99.0 by 0.1 Defaults – Last Calibration Procedure Comp None (Factory): 0 In vitro: 0 In vivo: Last in vivo Cal ScvO2/SvO2 Value Recall: Recalled ScvO2/ SvO2 Value HGB Update: 0 if an in vitro Cal was updated or Last in vivo Cal ScvO2/SvO2 value if an in vivo Cal was updated Parameter: HGB (g/dL): . Selection Range: 4.0 to 20.0 by 0.1 Defaults – Last Calibration Procedure Comp None (Factory): 0.0 In vitro: In vitro Cal HGB (g/dL) Value In vivo: Last in vivo Cal HGB (g/dL) Value Recall: Recalled HGB Value HGB Update: Updated HGB Value Parameter: HGB (mmol/L): Selection Range: 2.5 to 12.4 by 0.1 Defaults – Last Calibration Procedure Comp None (Factory): 0.0 In vitro: In vitro Cal HGB (mmol/L) Value In vivo: Last in vivo Cal HGB (mmol/L) Value Recall: Recalled HGB Value HGB Update: Updated HGB Value Parameter: Hct (%): Selection Range:12 to 60 by 1 Defaults – Last Calibration Procedure Comp None (Factory): 0 In vitro:In vitro Cal Hct Value In vivo: Last in vivo Cal Hct Value Recall:Recalled Hct Value HGB Update:Updated Hct Value CLEARSIGHT PUMP WITH KIT Physical and Mechanical Specifications Heart Reference Sensor: Weight 36 g: (0.08 lbs) Dimensions Length: 1.2 m ClearSight Finger Cuff Maximum Weight: 11g (0.02 lbs) LED Spectral Irradiance: See Figure A-1 Max Optical Output over treatment area: 0.013 4 mWatts Max variation of output over treatment area: 50% Monitor Weight: 2.1 kg (4.6 lbs) Dimensions Height: 226 mm Width: 296 mm Depth: 58.6 mm Display Active Area: 257 mm (10.4”) Resolution: 800 x 600 LCD Operating System: Windows XPe Speaker count: 2 Monitor (Advantech Model) Weight: 2 kg (4.4 lbs) Dimensions Height: 217 mm Width: 280 mm Depth: 46 mm Display Active Area: 266 mm (10.4”) Resolution: 1024 x 768 LCD Operating System: Windows XPe Speaker count 2 Pump-Unit 5 Weight (with Bracket) 3.1 kg (6.8 lbs) Dimensions (with Bracket) Height: 280 mm Width: 195 mm Depth: 165 mm Pressure Controller Weight: 0.35 kg (0.77 lbs) Dimensions Height: 97 mm Width: 54 mm Depth: 35 mm Cable Length: 3.5 m Environmental Specifications Clinical Platform NI Value Temperature: Operation: 10 to 37° C Storage and Transportation: 0 to 45° C Relative Humidity Operation: 15% to 85% noncondensing Storage and Transportation: 10% to 95% noncondensing Altitude Operation: 0 meter to 3,000 meter (9,843 ft) Storage and Transportation: -396 meter (-1,300ft) to 6,000 meter (19,685 ft) Base Parameters Parameter/ Specification Finger Cuff Pressure Display Range: 0 to 300 mmHg Accuracy: 1% of full scale (max 3mmHg), zeroing automatically CO 6 Display Range: 1.0 to 20.0 L/min Reproducibility:1 ±6% Update Rate: 20 seconds 1Coefficient of variation - measured using electronically generated data CABLE - FLOTRAC 16 FT TABLE ROLL STAND 12 Months Service Agreement to cover Hemodynamic Monitoring System and DataBox Assemblies. 7
© Copyright 2026 Paperzz