MXHG2 MX G2 Track Luminaire JOB NAME CATALOG NUMBER NOTES TYPE ELECTRICAL DATA LED Light Engine System Wattage * CCT / CRI Delivered Lumens ** L0 L1 L2 10W 16W 20W 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 950lm 1350lm 1700lm System Wattage include driver and LED Module consumption. Delivered lumen output will vary depending on CCT, CRI and optic selection. * ** LED LIGHT ENGINE -- 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning -- Class A 3500K with 80+ GAI and 90+ CRI to emphasize saturated colors -- Crisp White 3000K, vibrant whites and naturally saturated, warm tones with high CRI -- 50,000 hours L70 (rated life at 70% output) OPTICS -- 12° Spot, 24° Narrow Flood, 36° Flood and 50° Wide Flood ELECTRICAL SYSTEM -- 120V-277V 50/60Hz input -- Class 2 power supply -- Over voltage, over current and short circuit protection: Auto recovery -- This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty. TRACK COMPATIBILITY Track luminaire is designed for use with the following track systems: -- Single Circuit / Single Neutral 120V -- Two Circuit / Single Neutral 120V (No Dimming) -- J-Type Single /Two Circuit 120V -- L-Type Single / Two Circuit 120V ACCESSORIES Luminaire will accommodate (2) accessories, accessory holder required. 5 1/2” LISTING/WARRANTY -- ETL Listed to US and Canadian standards for damp locations -- 10-Year Intense LED Limited Warranty -- ENERGY STAR® Qualified 1 -- CEC (T24) Listed 2 1 6 15/16” 2 1 5/8” DIMMING Must specify -DIM for ELV Dimming -- (ELV) reverse phase control dimmers. 120V only. -- Dimmable 100 - 1% 3 3/8” 2 13/16” Horizontal Adjustability: 358º Verical Adjustability: 258º Example: MXHG2L230W-12 Track Head Wattage MXHG2 L0 (10 Watts) L1 (16 Watts) L2 (20 Watts) CCT / CRI 27 279 30 309 35 359 41 419 CA353 CW303 Driver (2700K / 82 CRI) (2700K / 92 CRI) (3000K / 82 CRI) (3000K / 92 CRI) (3500K / 82 CRI) (3500K / 92 CRI) (4100K / 82 CRI) (4100K / 92 CRI) (Class A 3500K) (Crisp White 3000K) blank(Non-Dimming) -DIM4 (ELV Dimming) Finish W(White) B(Black) SV(Silver) Beam Spread -12 (12º Spot) -24 (24º Narrow Flood) -36 (36º Flood) -50 (50º Wide Flood) Adapter blank -J -L Option (Intense Single / Two Circuit 120V) (J-Type Adapter 120V) (L-Type Adapter 120V) -S5 (Integral 1” Snoot) Accessories LH47 LH47W PFLMB-47 PFL1-47 PFL2-47 PFL4-47 (Accessory Holder, Black) (Accessory Holder, White) (Hex Louver, Black) (Prismatic Spread Lens) (Linear Spread Lens) (Soft Focus Lens) MX TRACK L/M-013:17 P-5 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. Notes: 1. Energy Star (82 CRI only) 2. CEC (T24) Listed (92 CRI - L0 & L1 only) 3. Available in L0 only 4. Dimming available in 120V only 5. Snoot is integral to fixture and factory installed. Snoot’s interior is black and compatible with accessory holder, black accessory holder recommended. MXHG2L030 12° Spot (-12) Report #: ILL-02112016-09 (-12) ILL-02112016-10 (-24) ILL-02112016-11 (-36) ILL-02182016-01 (-50) 50 8987 CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87) 1472 20° 10° TYPE 50° Wide Flood (-50) 80° 70° 567 60° 2944 ° 50 4416 40° 11983 NOTES 36° Flood (-36) 80° 70° 60° 5991 CATALOG NUMBER 24° Narrow Flood (-24) 80° 70° 2996 JOB NAME 20° 10° 263 60° 1133 ° 50 1700 40° 5889 30° 80° 70° 20° 10° 50° 789 40° 2267 30° 60° 526 ° 40° 1052 30° 10° 20° 30° Watts: 10 Lumens: 962 LPW: 96 CCT: 3000K Watts: 10 Lumens: 1023 LPW: 102 CCT: 3000K Watts: 10 Lumens: 1006 LPW: 101 CCT: 3000K Watts: 10.4 Lumens: 844 LPW: 81 CCT: 3000K Candelas at Nadir Candelas at Nadir Candelas at Nadir Candelas at Nadir Degree Candela Degree Candela Degree Candela Degree Candela 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 11983 9218 647 121 46 30 5889 5210 1647 179 22 6 2227 2267 1632 544 106 23D 1047 1034 908 544 233 82 D C D D 30o APPLICATION DATA: L L Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based W L FC FC W W illuminated plane. upon uniform illuminanceL aiming angle is the angle between the lamp W axis and the perpendicular to the C W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam. W L C D FC C 45o 30o DD DD D CC DD Beam width Beam length Distance to center of beam Distance Foot candles DD D D 3030 FC FCW LL WW FC L 0° HORIZONTAL D FC o o 3030 o o 30 LL CC L FCFC C W L D C FC W D C FC DD L o o 60D60 C 60o WW W W C LL 30° VERTICAL L 45o L WW 30° HORIZONTAL W o o 4545 LL FC WW CC 30o o D D C L W L W D 60° VERTICAL C CC C60o FC W LL L L MXHG2L030-12 3000K 12° Spot 6’ 8’ 10’ 12’ 333 187 120 83.2 1’ 6” 1’ 11” 2’ 5” 2’ 11” 1’ 6” 1’ 11” 2’ 5” 2’ 11” 6’ 8’ 10’ 12’ 3” 4’ 5’ 6’ 225 126 80.9 56.2 2’ 1” 2’ 6” 3’ 2” 3’ 8” 1’ 5” 2” 2’ 10” 3’ 4” 3.0’ 4.0’ 5.0’ 6.0’ 5’ 6’ 8’ 9’ 300 177 114 78.8 1’ 3” 1’ 8” 2’ 4” 2’ 11” 2’ 10” 3’ 6” 4’ 5” 5’ 3” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ WW 3’ 4’ 473 1’ 253 W 1’ 1” 180 1’ 3” 118 1’ 6” 1’ 1” 1’ 8” 1’ 5” 2’ 2” MXHG2L030-24 3000K 24° Narrow Flood 6’ 8’ 10’ 12’ 164 92 58.9 40.9 2’ 5” 3’ 2” 4’ 4’ 10” 2’ 5” 3’ 2” 4’ 4’ 10” 6’ 8’ 10’ 12’ 3’ 4’ 5’ 6’ 111 62.5 40 27.8 3’ 3’ 11” 4’ 10” 5’ 10” 2’ 8” 3’ 5” 4’ 3” 5’ 2” 3.0’ 4.0’ 5.0’ 6.0’ 5’ 6’ 7’ 9’ 149 88.6 55.5 39.4 2’ 4” 2’ 10” 3’ 7” 4’ 4” 3’ 10” 4’ 11” 6’ 4” 7’ 5” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ 3’ 4’ 236 125 89.1 59.1 1’ 3” 1’ 8” 2’ 4” 2’ 10” 1’ 6” 2’ 3” 2’ 7” 3’ 2” MXHG2L030-36 3000K 36° Flood 6’ 8’ 10’ 12’ 61.9 34.8 22.3 15.5 4’ 5’ 4” 6’ 8” 8’ 4’ 5’ 4” 6’ 8” 8’ 6’ 8’ 10’ 12’ 2’ 3’ 4’ 5’ 47.4 27.6 17.7 12.2 4’ 5” 5’ 8” 7’ 1” 8’ 6” 4’ 1” 5’ 4” 6’ 8” 8’ 3.0’ 4.0’ 5.0’ 6.0’ 4’ 5’ 6’ 7” 72 41.7 26.9 18.6 3’ 2” 4’ 2” 5’ 2” 6’ 3” 4’ 7” 5’ 11” 7’ 4” 8’ 10” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 3’ 4’ 96.6 54 33.9 24.1 2’ 5” 3’ 1” 3’ 9” 4’ 7” 2’ 7” 3’ 3” 4’ 2” 5’ MXHG2L030-50 3000K 50° Wide Flood 6’ 8’ 10’ 12’ 29.1 16.4 10.5 7.3 5’ 8” 7’ 7” 9’ 6” 11’ 5” 5’ 8” 7’ 7” 9’ 6” 11’ 5” 6’ 8’ 10’ 12’ 2’ 3’ 3’ 4’ 23.3 13.1 8.3 5.8 5’ 1” 6’ 9” 8’ 7” 10’ 3” 5’ 6’ 8” 8’ 5” 10’ 3.0’ 4.0’ 5.0’ 6.0’ 3’ 4’ 5’ 7’ 35.7 20.1 12.8 8.9 3’ 9” 5’ 1” 6’ 4” 7’ 7” 4’ 10” 6’ 5” 8’ 9’ 7” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 3’ 4’ 44.8 24.9 15.7 11.2 2’ 11” 3’ 11” 5’ 5’ 9” 3’ 1” 4’ 1” 5’ 2” 6’ 1” MX TRACK L/M-013:17 P-6 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. MXHG2L130 12° Spot (-12) Report #: ILL-02112016-08 (-12) ILL-02112016-07 (-24) ILL-02112016-06 (-36) ILL-02182016-02 (-50) 50 12633 CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87) 2064 20° 10° TYPE 50° Wide Flood (-50) 80° 70° 759 60° 4129 ° 50 6193 40° 16844 NOTES 36° Flood (-36) 80° 70° 60° 8422 CATALOG NUMBER 24° Narrow Flood (-24) 80° 70° 4211 JOB NAME 20° 10° 374 60° 1518 ° 50 2277 40° 8257 30° 80° 70° 20° 10° 50° 1122 40° 3036 30° 60° 743 ° 40° 1496 30° 10° 20° 30° Watts: 15.5 Lumens: 1361 LPW: 88 CCT: 3000K Watts: 15.5 Lumens: 1484 LPW: 96 CCT: 3000K Watts: 15.5 Lumens: 1377 LPW: 89 CCT: 3000K Watts: 15.5 Lumens: 1204 LPW: 78 CCT: 3000K Candelas at Nadir Candelas at Nadir Candelas at Nadir Candelas at Nadir Degree Candela Degree Candela Degree Candela Degree Candela 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 16844 13156 906 170 65 42 8230 7390 2426 273 32 8 3036 2964 2161 765 175 36D 1485 1486 1313 765 330 118 D C D D 30o APPLICATION DATA: L L Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based W L FC FC W W illuminated plane. upon uniform illuminanceL aiming angle is the angle between the lamp W axis and the perpendicular to the C W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam. W L C D FC C 45o 30o DD DD D CC DD Beam width Beam length Distance to center of beam Distance Foot candles DD D D 3030 FC FCW LL WW FC L 0° HORIZONTAL D FC o o 3030 o o 30 LL CC L FCFC C W L D C FC W D C FC DD L o o 60D60 C 60o WW W W C LL 30° VERTICAL L 45o L WW 30° HORIZONTAL W o o 4545 LL FC WW CC 30o o D D C L W L W D 60° VERTICAL C CC C60o FC W LL L L MXHG2L130-12 3000K 12° Spot 6’ 8’ 10’ 12’ 468 263 168 117 1’ 6” 2’ 2’ 5” 2’ 11” 1’ 6” 2’ 2’ 5” 2’ 11” 6’ 8’ 10’ 12’ 3’ 4’ 5’ 6’ 319 179 115 79.7 2’ 1” 2’ 6” 3’ 2” 3’ 9” 1’ 5” 2’ 2’ 10” 3’ 4” 3.0’ 4.0’ 5.0’ 6.0’ 5’ 6’ 8’ 9’ 422 252 160 112 1’ 3” 1’ 8” 2’ 4” 2’ 11” 2’ 10” 3’ 6” 4’ 5” 5’ 3” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ WW 3’ 4’ 672 1’ 1” 359 W 1’ 1” 253 1’ 3” 168 1’ 6” 1’ 1” 1’ 8” 1’ 5” 2’ 2” MXHG2L130-24 3000K 24° Narrow Flood 6’ 8’ 10’ 12’ 229 129 82.3 57.1 2’ 6” 3’ 4” 4’ 1” 4’ 11” 2’ 6” 3’ 4” 4’ 1” 4’ 11” 6’ 8’ 10’ 12’ 3’ 4’ 5’ 6’ 157 88.3 56.5 39.2 3’ 4’ 4’ 11” 5’ 11” 2’ 8” 3’ 6” 4’ 5” 5’ 3” 3.0’ 4.0’ 5.0’ 6.0’ 4’ 6’ 7’ 9’ 211 125 78.8 55.6 2’ 4” 2’ 11” 3’ 8” 4’ 5” 3’ 11” 5’ 6’ 4” 7’ 6” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ 3’ 4’ 334 177 125 83.5 1’ 4” 1’ 8” 2’ 5” 2’ 11” 1’ 6” 2’ 3” 2’ 8” 3’ 2” MXHG2L130-36 3000K 36° Flood 6’ 8’ 10’ 12’ 84.3 47.4 30.4 21.1 4’ 2” 5’ 6” 6’ 11” 8’ 4” 4’ 2” 5’ 6” 6’ 11” 8’ 4” 6’ 8’ 10’ 12’ 2’ 3’ 4’ 5’ 62 35.8 22.9 15.8 4’ 5” 5’ 9” 7’ 2” 8’ 8” 4’ 2” 5’ 5” 6’ 9” 8’ 2” 3.0’ 4.0’ 5.0’ 6.0’ 4’ 5’ 6’ 7” 93.1 54 34.8 24.2 3’ 2” 4’ 3” 5’ 3” 6’ 4” 4’ 8” 6’ 7’ 5” 8’ 11” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 3’ 4’ 128 69.8 45.9 32 2’ 5” 3’ 1” 3’ 8” 4’ 7” 2’ 7” 3’ 4” 4’ 1” 5’ MXHG2L130-50 3000K 50° Wide Flood 6’ 8’ 10’ 12’ 41.3 23.2 14.9 10.3 5’ 7” 7’ 6” 9’ 4” 11’ 2” 5’ 7” 7’ 6” 9’ 4” 11’ 2” 6’ 8’ 10’ 12’ 2’ 3’ 3’ 4’ 33.4 18.4 11.9 8.3 5’ 1” 6’ 10” 8’ 6” 10’ 2” 5’ 6’ 11” 8’ 5” 10’ 1” 3.0’ 4.0’ 5.0’ 6.0’ 3’ 4’ 5’ 6’ 51.6 29 18.6 12.9 3’ 8” 5” 6’ 4” 7’ 7” 4’ 9” 6’ 4” 7’ 10” 9’ 5” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 3’ 4’ 63.8 35.1 22.5 15.9 3’ 3’ 11” 5’ 5’ 9” 3’ 1” 4’ 2” 5’ 2” 6’ 2” MX TRACK L/M-013:17 P-7 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice. MXHG2L230 12° Spot (-12) Report #: ILL-02032016-05 (-12) ILL-02112016-02 (-24) ILL-02112016-03 (-36) ILL-02162016-04 (-50) 50 16867 CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87) 2485 20° 10° TYPE 50° Wide Flood (-50) 80° 70° 927 60° 4970 ° 50 7454 40° 22489 NOTES 36° Flood (-36) 80° 70° 60° 11245 CATALOG NUMBER 24° Narrow Flood (-24) 80° 70° 5622 JOB NAME 20° 10° 479 60° 1855 ° 50 2782 40° 9939 30° 80° 70° 20° 10° 50° 1436 40° 3709 30° 60° 957 ° 40° 1915 30° 10° 20° 30° Watts: 20.4 Lumens: 1820 LPW: 89 CCT: 3000K Watts: 20.6 Lumens: 1801 LPW: 87 CCT: 3000K Watts: 20.6 Lumens: 1673 LPW: 81 CCT: 3000K Watts: 20.3 Lumens: 1539 LPW: 76 CCT: 3000K Candelas at Nadir Candelas at Nadir Candelas at Nadir Candelas at Nadir Degree Candela Degree Candela Degree Candela Degree Candela 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 0° 5° 15° 25° 35° 45° 22052 18360 868 168 68 42 9923 8887 2955 322 41 10 3699 3654 2669 925 193 42D 1867 1915 1675 987 404 149 D C D D 30o APPLICATION DATA: L L Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based W L FC FC W W illuminated plane. upon uniform illuminanceL aiming angle is the angle between the lamp W axis and the perpendicular to the C W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam. W L C D FC C 45o 30o DD DD D CC DD Beam width Beam length Distance to center of beam Distance Foot candles DD D D 3030 FC FCW LL WW FC L 0° HORIZONTAL D FC o o 3030 o o 30 LL CC L FCFC C W L D C FC W D C FC DD L o o 60D60 C 60o WW W W C LL 30° VERTICAL L 45o L WW 30° HORIZONTAL W o o 4545 LL FC WW CC 30o o D D C L W L W D 60° VERTICAL C CC C60o FC W LL L L MXHG2L230-12 3000K 12° Spot 6’ 8’ 10’ 12’ 613 345 221 153 1’ 5” 2’ 2’ 6” 3’ 1” 1’ 5” 2’ 2’ 6” 3’ 1” 6’ 8’ 10’ 12’ 3’ 4’ 5’ 6’ 427 240 154 107 2’ 1” 2’ 7” 3’ 5” 4’ 1’ 6” 2’ 3” 2’ 11” 3’ 6” 3.0’ 4.0’ 5.0’ 6.0’ 5’ 6’ 8’ 9’ 564 338 214 150 1’ 4” 1’ 11” 2’ 6” 3’ 3’ 3’ 8” 4’ 8” 5’ 7” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ WW 3’ 4’ 900 1’ 480 W 1’ 1” 338 1’ 4” 225 1’ 7” 1’ 1” 1’ 9” 1’ 7” 2’ 3” MXHG2L230-24 3000K 24° Narrow Flood 6’ 8’ 10’ 12’ 276 155 99.2 68.9 2’ 6” 3’ 4” 4’ 1” 4’ 11” 2’ 6” 3’ 4” 4’ 1” 4’ 11” 6’ 8’ 10’ 12’ 3’ 4’ 5’ 6’ 188 106 67.8 47.1 3’ 4’ 4’ 11” 6’ 2’ 9” 3’ 6” 4’ 5” 5’ 3” 3.0’ 4.0’ 5.0’ 6.0’ 4’ 6’ 7’ 9’ 253 150 94.8 66.8 2’ 5” 2’ 11” 3’ 8” 4’ 5” 3’ 11” 5’ 1” 6’ 4” 7’ 6” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 2’ 3’ 4’ 401 212 150 100 1’ 4” 1’ 8” 2’ 5” 2’ 11” 1’ 6” 2’ 3” 2’ 8” 3’ 3” MXHG2L230-36 3000K 36° Flood 6’ 8’ 10’ 12’ 103 57.8 37 25.7 4’ 1” 5’ 6” 6’ 11” 8’ 4” 4’ 1” 5’ 6” 6’ 11” 8’ 4” 6’ 8’ 10’ 12’ 2’ 3’ 4’ 5’ 77.5 44.6 28.5 19.6 4’ 5” 5’ 9” 7’ 2” 8’ 8” 4’ 1” 5’ 5” 6’ 9” 8’ 1” 3.0’ 4.0’ 5.0’ 6.0’ 4’ 5’ 6’ 7’ 116 67.3 43.5 30.2 3’ 2” 4’ 2” 5’ 3” 6’ 3” 4’ 7” 5’ 11” 7’ 4” 8’ 10” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 3’ 4’ 157 86.7 56.1 39.3 2’ 5” 3’ 1” 3’ 8” 4’ 7” 2’ 8” 3’ 4” 4’ 2” 5’ MXHG2L230-50 3000K 50° Wide Flood 6’ 8’ 10’ 12’ 51.9 29.2 18.7 13 5’ 7” 7’ 5” 9’ 4” 11’ 2” 5’ 7” 7’ 5” 9’ 4” 11’ 2” 6’ 8’ 10’ 12’ 2’ 3’ 4’ 4’ 43.1 24 15.4 9.7 5’ 1” 6’ 10” 8’ 6” 10’ 1” 5’ 6’ 8” 8’ 4” 9’ 11” 3.0’ 4.0’ 5.0’ 6.0’ 3’ 4’ 5’ 7’ 65.8 37 23.7 16.5 3’ 8” 5’ 1” 6’ 4” 7’ 7” 4’ 10” 6’ 5” 7’ 11” 9’ 6” 3.0’ 4.0’ 5.0’ 6.0’ 2’ 3’ 4’ 4’ 81.5 45.8 28.8 20.4 3’ 3’ 11” 5’ 5’ 10” 3’ 2” 4’ 2” 5’ 2” 6’ 2” MX TRACK L/M-013:17 P-8 Intense Lighting 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 ©2016 Intense Lighting, LLC. All rights reserved. Subject to change without notice.
© Copyright 2026 Paperzz