Faulty Code Description Solution

Faulty Code
Solution
Description
SCI Fault
When the port which used for programing and debugging is broken,this fault will happen
CAN1 Fault
PV Config Fault
the communication between two boards is disconnected.
The setting of PV connection is wrong
Inv EEPROM Fault
The ROM in the internal circuit is damaged
Relay Fault
The internal Relay is Broken.
sample Fault
Sample data of two chips on the same board are different
RCD Fault
Residue current device is damaged
Fan1 Fault
FAN 1 is fault
Fan2 Fault
FAN 2 is fault
AC HTC Fault
The internal CT of AC plug is damaged.
Over load Fault
Loads are exceed the standard value
DCI Device Fault
The DCI current sensor is damaged
EPS Relay Fault
The relay of EPS side is dammaged
TZ Protect Fault
Grid lost Fault
Grid Volt Fault
Grid Freq Fault
Protect internal over current of hardware
There is no electricity on the AC side
The voltage on AC side is not in the range
The frequency on AC side is not in the range
PLL Lost Fault
This fault is caused by the local grid
BUS Volt Fault
BUS voltage is higher than the maxnium value
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
AC5M Volt Fault
The AC grid voltage more than the required value and last 5 minutes will give this alarm
Contact SolaX
Inv OCP Fault
PV Volt Fault
protect inverter for over current.
PV voltage is too high
Contact SolaX
Contact SolaX
AC10M Volt Fault
The AC grid voltage more than the required value and last 5 minutes will give this alarm
Contact SolaX
Isolation Fault
Temp Over Fault
The impedance between PV(+) PV(-)and ground is too low.
Internal temperature of inverter is too high
Fan1 Speed Fault
The speed of FAN1 is abnormal
Fan2 Speed Fault
The speed of FAN2 is abnormal
C1 Can Fault
C1 Temp High
Communication between charger 1 and inverter is damaged
The temperature of charger 1 is too high
C1 FAN Fault
The FAN of charger 1 is damaged
C1 TZ Fault
Internal over current of hardware of charger 1
C1 EEPROM Fault
The ROM of charger 1 in the internal circuit is damaged
C1 HTC 1 Fault
C1 HTC 2 Fault
C1 BUS OVP
C1 Temp Low
C1 Boost OVP
C1 Bat OVP
C1 Charger OCP
C1 Boost OCP
CT Fault
The HALL CT1 of charger 1 is damaged
The HALL CT2 of charger 1 is damaged
BUS voltage of charger 1 is higher than the maxnium value
The temperature of charger 1 is too low
Boost over voltage is protected by charger 1
The battery voltage to charger is too high
Over current of charger 1 is detected
Over current of boost of charger 1 is detected
Something wrong about current transformer
RC Fault
Residual current is in the wrong value
DCI OCP Fault
The protection of the DCI current
Other device Fault
SW OCP Fault
The other device is damaged
Protect inverter for over current.
DM 9000 Fault
The Ethernet communication chip is damaged
RTC Fault
Setting of time is wrong
Mgr EEPROM Fault
The ROM of manager board is damaged
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)
Contact SolaX
Replace if frequantly happens, and cannot
recover after re-start(Pic needed)