Technical Information Bulletin – TB016 Company: All Installers Date: 01/09/14 To: Technical & Installation Departments From: Woodway Engineering Limited Number of Pages: 1 ION SURFACE MOUNT SERIES LIGHT HEADS IMPORTANT: When fitting the light head, the gasket must be fitted in the correct orientation. The mounting holes must be higher than the cable entry hole as illustrated below. The vent channel in the gasket is for the vent membrane* (a small fabric like disc) on the rear of the lamp and must be properly positioned over it. DO NOT damage or remove the vent membrane. TOP Mounting holes 44165 Vent Channel MFG in USA Cable Entry Hole Ensure the gasket supplied is used and the light head is mounted in the correct orientation with the Whelen logo at the bottom (see below). Note Whelen Logo *The small fabric disk is of a 'Gore-Tex' type material which allows water and condensation to exit the lamp but not enter. It must therefore be aligned with the vent channel in the rubber mounting gasket which allows venting to atmosphere via the cable entry hole. When mounting the light head DO NOT apply sealant to the area around the cable entry hole as this will seal the vent channel and prevent venting to atmosphere. If properly fitted the light head will not require additional sealing and will provide years of quality service.