Platform Touch Voltage Protection Membrane System exclusively from TOKAI-OMNI! A Protection Solution In Accordance to the International Standards of VDE 0115 and EN 50122-1. Introduction Tokai-Omni Platform Touch Voltage Protection Membrane System (PTVPMS) is a customized solution installed at MRT Platforms to safeguard passengers on the platform from possible electrical shocks caused by touch and step voltages. These electrical shocks can occur during: • Boarding / Alighting • Physical contact with the train • Physical contact with Platform Screen Doors (PSDs). Potential Hazards Potential hazards such as electrical shocks to passengers due to the different voltage potentials which can occur around the platform edge especially between the platform screen door and train or train depot workshop area. For our MRT system, the platform screen doors that are installed at the underground and elevated stations are in close proximity to the train at the station platform edge, and this is the area that poses the highest risk to touch potential and its associated hazards. Therefore to mitigate this risk, a protection zone in the form of an insulation system is required, and in doing so we are able to protect passengers on the platform from accidental contact with high voltage that with sufficient energy may result in severe injury or death. System Benefits Our insulation membrane solution is in accordance to the International Standards of VDE 0115 and EN 50122-1 Bonded type Membrane with hot-liquid applied to the required thickness (2.5mm – 3mm) both horizontal and vertical application No adhesive used, hence porous or air-void between membrane and concrete is avoided. Earth resistance compliance test in accordance to the BS 7430 and MS IEC 62305:2006 Proven reliability and durability for MRT Projects Advancing Safety, Protecting Critical Assets A customised solution specifically for Mass Rail Transit Stations www.tokai.com.my Membrane Type The Protection Zone The protection zone coverage of the membrane shall be 1.8 to 2.4m away from the Passengers Screen Door (PSD) and to the height of 2.5m above Finished Floor Level (FFL). Bonded type Membrane with hot-liquid applied to the required thickness of 2.5mm – 3mm for both horizontal and vertical applications. Membrane Specifications 2.5m Subjected to Volume Resistivity Test of ASTM D257:2007 Standard and results states that the Volume Resistivity is tested to exceed 5x1014 ohm-cm. 1.8 to 2.4m image for illustration purposes only ISO9001:2008 certified in Lightning, Surge Protection & Security Solutions and a winner of multiple industry awards! Insulation Sealant Testing of the membrane shall be carried out with the Digital Insulation Tester with a testing voltage of 250/500V DC and the passing criteria shall be as follows: Photos courtesy of Tokai-Omni. Copyright reserved. Testing of Membrane A High Resisitivity Sealant shall be used to seal off all gaps between the floor and the Insulation Membrane which have the following characteristics in accordance to ASTM D257:2007 Standard: • Volume Resistivity : 1 x 1014 ohm – cm • Elongation Break : 200% • Shore hardness : 50 min On Membrane Surface - 50,000 ohm in dry/damp condition On Platform Surface - 35,000 ohm in dry condition - 10,000 ohm in damp condition Tokai-Omni PTVPMS with PSD doors installed european ec ec group ISO 9001 REGISTERED FIRM certification Lot 14, Jalan Astaka U8/82,Seksyen U8, Bukit Jelutong, 40150 Shah Alam, Selangor Darul Ehsan. Tel: 603-7845 2323 | Fax: 603-7845 5420 Email: [email protected] european certification Tokai Engineering (M) Sdn Bhd (259755-W) Tokai-Omni PTVPMS Site Installation group 4152 ISO 9001 REGISTERED FIRM QS 081220007 CB 07 TESTED AND CERTIFIED COMPLIANT TO M S I E C 6 2 3 0 5 , B S E N 6 2 3 0 5 : 2 0 0 6 & PA S 6 8
© Copyright 2025 Paperzz