TeraScanHR Reticle Inspection System High-resolution, die-to-database reticle inspection for 45nm production INSPECTION TeraScanHR The TeraScanHR Reticle Inspection System provides powerful new technology and productivity features that enable the production of defect free reticles for 45nm. The new system includes higher resolution optical imaging for a smaller pixel size, new capabilities for inspecting aggressive Optical Proximity Correction (OPC), and higher speed image processing to improve productivity. This system provides three inspection modes (die-to-die, die-todatabase, and STARlight for contamination defect) along with both illumination modes (transmitted and reflected light). These new advances in technology enable the system to find all types of reticle defects including random reticle manufacturing defects and SubResolution Assist Feature (SRAF) defects, and extensions. The TeraScanHR system’s high sensitivity, improved productivity, and flexible configurations make it a cost-effective solution that meets the needs of mask manufacturers. New Image Acquisition The TeraScanHR System provides a higher NA capability to resolve smaller lines, OPC, SRAF and defects. The higher NA supports the new 72nm pixel. Depending on the model, the user can select different pixel sizes (72, 90, 125, 150nm) allowing for faster scan times when a less sensitive inspection is needed. Additionally the quality of the optical elements was improved for better imaging uniformity to reduce false detections associated with small OPC and SRAF. This improved imaging allows OPC designers to use smaller OPC for current generations to improve yield. The TeraScanHR includes a new autofocus sub-system which provides the necessary precision for the higher NA optics which has lower depth of focus. The new autofocus has improved capability to maintain proper focus when inspecting reticles with significant topology such as complex tri-tone (CTT) and quartz etch types. To further improve imaging, the stage has been modified to achieve lower vibration levels. Die-to-Database Modeling The basic detection method overlays a test image with a matching reference image and identifies differences that are the result of a defect. For die-to-die inspection, the test and reference images compared are from adjacent die; for die-to-database inspection the reference image is reconstructed from the database. Sophisticated alignment and detection algorithms provide high sensitivity and low false detections. In addition, the new die-to-database defect detection algorithm (URR) allows for precise modeling of small OPC structures in both transmitted and reflected light. Condenser Photomask Transmitted Illumination Objective Laser Source Reflected Illumination Reflected Image TDI Sensor Transmitted Image The custom designed objective images the reticle surface through the zoom lens onto the imaging sensor. The zoom lens allows users to select different pixels allowing for faster scan times when a less sensitive inspection is desired. Image pick-up is done by a time-domain-integration (TDI) sensor. This sensor offers high speed continuous image pick-up at lower light levels than a conventional linear sensor. At the bottom is shown high resolution transmitted and reflected images of a binary reticle. An oversize clear serif defect is present and visible in both the transmitted and the reflected images; however, a particle on the dark material is also present but is only visible in the reflected light image (dark spot). Reticle Inspection System High Productivity Transmitted and Reflected Light The system allows for selecting between transmitted and reflected illumination, each illumination mode has the best performance for different classes of defects and different geometry types. The integrated transmitted and reflected modes provides the highest quality inspection. Additionally, the integrated transmitted and reflected light mode scan leads to productivity gains with a ~2x scan time improvement from the separate mode scans. Transmitted Light Reflected Light Integrated transmitted and reflected light mode provides a higher quality inspection and offers higher productivity. 72nm pixel 45nm node Logic > – 90nm node Logic TeraScan - R platform 65nm node Logic 90nm pixel 125nm pixel 150nm pixel TeraScan - H platform 32nm node Logic 90nm pixel 125nm pixel 150nm pixel Flexible configurations to handle 130nm to 45nm node mask requirements, and 32nm development. Optical image on photomask Flexible Configurations The TeraScanHR can be configured as a variety of different models to inspect reticles from the 130nm node to the 45nm node. This upgradeability allows users to purchase a model based on their capability needs and then upgrade as more capability is needed, thus optimizing capital efficiency. Image Processing Computer The throughput of a system can be limited by its image processing computer particularly when using compute intensive defect detection algorithms. The new system includes a new image processing computer which has more than 2x the compute capability of the previous systems. This allows for higher productivity when using a compute intensive inspection mode such as integrated transmitted and reflected light. The KLA-Tencor Solution The new advanced die-to-database high-resolution reticle defect inspection system has been developed to meet the reticle qualifications for the IC industry for 45nm advanced production. The higher NA optics, new autofocus, smaller pixel size, and improved rendering and modeling of algorithms show significant improvement in inspection capability of small linewidths, small defects, and aggressive OPC versus the current technology. Finally, reflected light can be integrated with transmitted light with no additional scan time for some modes. These improvements enable mask manufacturers to produce defect free reticles. SEM image on wafer High-resolution inspection detects small defects on the reticle prior to printing on a wafer improving productivity during the manufacturing process. The integrated transmitted and reflected mode captures defects that have significant topography that scatters light. INSPECTION TeraScanHR BENEFITS • Image acquisition system includes higher numerical aperture optics that supports the new 72nm pixel to provide accurate imaging of aggressive Optical Proximity Correction (OPC) and small defects. • The autofocus subsystem uses a pre-mapping technique to reduce focus error and maintain proper focus for advanced reticles with significant topology. • New modeling algorithms significantly improve the accuracy for small structures such as aggressive OPC which leads to lower false detections and improved sensitivity. • Reflected light combined with transmitted light provides a higher quality inspection since reflected light is typically more sensitive to clear defects such as pinholes, extensions, and to defects on clear SRAFs, while transmitted light is typically more sensitive to opaque defects and critical dimension (CD) errors. • Integrated transmitted and reflected light mode combined with increased compute capability shows a ~2x scan time improvement leading to the production of higher quality reticles at a lower cost per inspection. • More than 4+ generation extendibility allows the system to handle a broad range of nodes so that reticle manufacturers can purchase just the capability needed at the time, and then upgrade as more capability is needed in the future. KLA-TENCOR SERVICE/SUPPORT Customer service and support are an integral part of KLA-Tencor’s yield optimization solution. Our vast customer support organization services our worldwide installed base and is responsible for customer support following shipment of equipment and software. Services include system installation, secure online monitoring, on-site repair, telephone support, relocation services, and selected post-sales applications. © 2007 KLA-Tencor Corporation. All brands or product names may be trademarks of their respective companies. KLA-Tencor reserves the right to change the hardware and/or software specifications without notice. Printed in the USA PB-TSHR-04/07 KLA-Tencor Corporation 160 Rio Robles San Jose, CA 95134 phone 408.875.3000 fax 408.875.4144 www.kla-tencor.com
© Copyright 2024 Paperzz