Oxygen Sensors www.nuova.de E -09/0 E Connector: 3 Pin Wired Molex Measuring Range: 0-100% O2 Output Signal: 9.5–14 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E -16/0 -33/1 E -15/0 Connector: 2 Gold Plated Contact Rings Measuring Range: 0-100% O2 Output Signal: 14–20 mV Response Time: < 20 seconds Warranty: 18 months Storage: up to 6 months -17/A2 E -77/0 E -15/3 Connector: 3 Gold Plated Contact Rings Measuring Range: 0-100% O2 Output Signal: 14–20 mV Response Time: < 20 seconds Warranty: 18 months Storage: up to 6 months -17/J Connector: 3.5 mm Mono Jack Measuring Range: 0-100% O2 Output Signal: 13–17 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E Connector: RJ11 Modular Plug 4P4C Measuring Range: 0-100% O2 Output Signal: 7.5–12.5 mV Response Time: < 8 seconds Warranty: 16 months Storage: up to 6 months O -15/0 Connector: 2 Contact Rings Gold Plated Measuring Range: 0-100% O2 Output Signal: 14–20 mV Response Time: < 17 seconds Warranty: 16 months Storage: up to 6 months Connector: 3 Pin Molex Measuring Range: 0-100% O2 Output Signal: 8–12.5 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months Connector: Double Wired PCB Plug Measuring Range: 0-100% O2 Output Signal: 200 μA Response Time: < 20 seconds Warranty: 16 months Storage: up to 3 months O E Connector: Wired Phone Connector Measuring Range: 0-100% O2 Output Signal: 8–12 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months Connector: 3 Pin Molex Measuring Range: 0-100% O2 Output Signal: 9.5-16 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E -14/0 -77/0S Connector: RJ11 Modular Jack 4P4C Measuring Range: 0-100% O2 Output Signal: 9–12 mV Response Time: < 13 seconds Warranty: 16 months Storage: up to 3 months O -17-MH Connector: 3 Pin Molex Measuring Range: 0-100% O2 Output Signal: 7–13 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months E -15/2 E Connector: 3 Contact Rings Measuring Range: 0-100% O2 Output Signal: 14.5–20.5 mV Response Time: < 12 seconds Warranty: 15 months Storage: up to 6 months E -17/M -15/4 E Connector: Modular Jack Measuring Range: 0-100% O2 Output Signal: 8–12 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E -17/J1 Connector: 3.5 mm Mono Jack Measuring Range: 0-100% O2 Output Signal: 8–12 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E Oxygen Sensor Connector: 3 Pin Molex Measuring Range: 0-100% O2 Output Signal: 13-16.5 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E -8000 Connector: 3 Gold Plated Contact Rings Measuring Range: 0-100% O2 Output Signal: 14.5–19.5 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months O -33/2 Connector: Double Wired PCB Plug Measuring Range: 0-100% O2 Output Signal: 165–235μA Response Time: 30 seconds Warranty: 12 months Storage: up to 3 months Connector: Gold Plated Contact Rings Measuring Range: 0-100% O2 Output Signal: 200 μA Response Time: < 20 seconds Warranty: 16 months Storage: up to 3 months -43/0 Connector: Gold Plated Contact Rings Measuring Range: 0-100% O2 Output Signal: 25–35 mV Response Time: < 17 seconds Warranty: 12 months Storage: up to 3 months O -33/0 Oxygen Sensor Connector: Straight Power Jack Measuring Range: 0-100% O2 Output Signal: 9–14 mV Response Time: < 12 seconds Warranty: 16 months Storage: up to 6 months E -15/5 -55/0 Connector: PCB 4 Pins Measuring Range: 0-100% O2 Output Signal: 25–40 mV Response Time: 9 seconds Warranty: 14 months Storage: up to 6 months Interferences: according to DIN EN 12598 and ISO 767 All technical data are based on a temperature of 25°C, 50% Relative Humidity and 1013hPa pressure. O -58/0 Connector: Phone Jack Measuring Range: 0-100% O2 Output Signal: 70–160 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months O -60/0 O Connector: Phone Jack Measuring Range: 0-100% O2 Output Signal: 4–6 mV Response Time: 6 seconds Warranty: 18 months Storage: up to 6 months O -75/KE4 -75/KE1 O Connector: Wire Leads Measuring Range: 0-100% O2 Output Signal: 10–14 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months O Connector: Wire Leads Measuring Range: 0-100% O2 Output Signal: 10–14 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months Interferences: according to DIN EN 12598 and ISO 767 All technical data are based on a temperature of 25°C, 50% Relative Humidity and 1013hPa pressure. -75/KE6 Connector: Wire Leads Measuring Range: 0-100% O2 Output Signal: 10–14 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months -75/KE2 Connector: Wire Leads Measuring Range: 0-100% O2 Output Signal: 10–14 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months O -75/KE8 Connector: Wire Leads Measuring Range: 0-100% O2 Output Signal: 10–14 mV Response Time: 13 seconds Warranty: 18 months Storage: up to 6 months Nuova provides the widest range of replacement Oxygen Sensors for medical use for the following brands: Airshields, Alphamed, AII, Atom, BCI, Bertucci, BioMed, Bio Tek, Bird, BMD, Cheiron, City Technologies, Criticare, Dameca, Datascope, Datex-Engström, Devilbiss, Dräger, Dräger North America, EME, Emerson, EnviteC, Fresenius, Hamilton, Heinen und Löwenstein, Heyer, Henleys, Hill-Rom AS, Hudson, Imed, Invivo, IVAC, Kontron, Libra, Lifecare, GE-Marquette, Maxtec, Medigas, Megamed, Mercury Medical, MSA, Newport, Nivaco, Ohmeda, Oxitron, Patient Tech, Penlon, Prolab Puritan-Bennett, Respironics, Schoch, Sechrist, Sensidyne, Siare, Siemens, SLE, Spacelabs, Stephan, Taema, Teledyne, Toptronix, Ventrex, Ventronics, Viasys, Vickers, VTI For detailed specifications please contact Nuova Nuova GmbH Luebecker Strasse 17 · 23909 Ratzeburg · Germany · Phone: +49(0)4541·85 70 90 · Fax: +49(0)4541·857 09 29 E-mail: [email protected] · Internet: www.nuova.de
© Copyright 2026 Paperzz