Operation, Maintenance & Installation Manual Emergency Oxygen Inlet Station Low Pressure 2” Recessed Mount Surface Mount Model#: M-FILL-OXY-LP2 Model#: M-FILL-OXY-LP2S w w w . a m i c o . c o m Contents Introduction 3 Medical Facility Responsibility 3 Installation of Emergency Oxygen Inlet Station 4 Operating Instructions 4 Repair and Replacement Parts List 5 Schematic Drawings 2 6-7 Optional Check and Relief Valves Parts List 7 Model Numbers Also Available 7 Amico Pipeline Introduction As required by NFPA-99 (National Fire Protection Association), Health Care Facilities oxygen systems having the source of supply outside the building shall have an inlet to connect a temporary, auxiliary source of supply for emergency or maintenance situations. This connection shall include necessary valves and to allow for an emergency supply of oxygen and isolation of the normal source of supply. The inlet connection shall be a 2” female NPT connection and be provided with a plug to prevent entry of foreign matter into the oxygen system when not in use. Medical Facility Responsibility Amico Emergency Oxygen Inlet Stations will perform in conformity with the descriptions contained in this manual and accompanying labels and/or inserts when a ssembled, operated, maintained and repaired in accordance with the instructions provided. Emergency Oxygen Inlet Stations must be inspected periodically. A defective product should not be used. Parts that are broken, missing, plainly worn, distorted or contaminated should be replaced immediately. Should such repairs or replacements become necessary, please contact your local distributor. www.amico.com 3 Installation of Emergency Oxygen Inlet Station NOTE: Prior to installation, inspect the unit to ensure no tampering or damages were incurred. 1. Anchor the oxygen inlet station on a finished wall with the appropriate hardware. 2. Before brazing, wrap wet rags around the tube extension next to the valve body to prevent overheating and possible damage to the valve seals. Connect copper tubing to the copper extension using brazing methods and materials in accordance with NFPA-99 or CSA Z7396.1. 3. Test the system for leaks (as per appropriate standards). Operating Instructions To Operate: 1. Ensure that the isolation valve is closed. 2. Open the threaded connection. 3. Connect a pigtail to the oxygen threaded connection. 4. Check the inlet pressure gauge for supply pressure. 5. Ensure that the connection is not leaking. 6. Open the outlet valve. 7. The “Emergency Oxygen Inlet Station” is now in operation. To Shut Down: 1. Ensure that the main bulk oxygen system is working correctly. 2. Close the isolation valve. 3. Close the supply pressure to the pigtail. 4. Open the threaded connection. 5. Replace the cover plug. 6. Close the cover and engage the padlock. 4 Amico Pipeline Repair and Replacement Parts List: 1. V-X-RK-NIB-20 Repair kit for 2” ball valve - seats and O-rings 2. V-X-VLV-HAND-L Valve handle sleeve for 2” 3. V-X-GAUGE-100 Gauge 100 psi/690 kPa – 1/8” NPT 4. M-X-OXF-20-PLG 2” NPT hex-head plug 5. V-X-BOX-PLUG-25-B Box plug for oxygen inlet station 2 ½” (black) 6. V-X-BOX-PLUG-30-B Box plug for oxygen inlet station 3” (black) Recessed Mount Surface Mount 1 1 3 4 2 4 2 3 Front view Front view 6 5 Bottom view Back view www.amico.com 5 Schematic Drawing - Recessed Mount Typical Piping Connect to pipeline 25.5 [648] 8 12" [305] [203] Check Valve Emergency Low Pressure Oxygen Inlet Box. Main Oxygen Supply Shutoff Valve 28 18-1/2" [711] [470] 27 17-1/2" [445] [686] Relief Valve 75 PSIG Turn Down and Screen Pressure Switch Main Line Shutoff Valve Provision for Padlock 16 12" [406] [305] 13-1/2" 17.5 14-1/2" 18.5 [343] [445] [368] [470] Inlet Oxygen connection 2" NPT 7-1/4" 8 [184] [203] 2" Type "K" Copper outlet pipes. Model Number: M-FILL-OXY-LP2 6 Amico Pipeline Check Valve Schematic Drawing - Surface Mount Typical Piping Turn Down and Screen Relief Valve 75 PSIG Emergency Low Pressure Oxygen Inlet Box Shutoff Valve 26" [660] Shutoff Valve 26 [660] Main Oxygen Supply Pressure Switch Check Valve 8 [203] 8" [203] 11 [279.4] 17 [431] Inlet Oxygen connection 2" NPT Inlet Oxygen connection 2” NPT 18" [457] Main Line Shutoff Valve 17" [431] 2" Type "K" Copper outlet pipes 2” Type “K” Copper Outlet Pipes Model Number: M-FILL-OXY-LP2S Optional Check and Relief Valves (to be ordered separately): Check Valve 1”VV-CHK3-EXT10 Check Valve 1-1/2”VV-CHK3-EXT15 Check Valve 2”VV-CHK3-EXT20 Relief Valve Pipe Away Adapter ½” NPT (NFPA) M-X-PIPEAWAY-05 Relief Valve (NFPA)M-X-MAN-72W-075 Relief Valve (CSA)M2-X-MAN-73-075 Model numbers also available: M-FILL-OXY-LP-S M-FILL-OXY-LP M-FILL-OXY-S M-FILL-OXY Emergency low pressure oxygen inlet station 1” surface mounted Emergency low pressure oxygen inlet station 1” recessed mounted Emergency high pressure oxygen inlet station 1” surface mounted Emergency high pressure oxygen inlet station 1” recessed mounted www.amico.com 7 www.amico.com Amico Pipeline | www.amico.com 85 Fulton Way, Richmond Hill Ontario, L4B 2N4, Canada Toll Free Tel: 1.877.462.6426 Toll Free Fax: 1.866.440.4986 Tel:905.764.0800 Fax:905.764.0862 Email:[email protected] APE-OM-INSTAL-EOIS-LP-2IN 01.07.2014
© Copyright 2026 Paperzz