Sto Specification Australia SS105 StoTherm Vario on MasterWall® Insulation Panel StoTherm Vario Mineral Render System over MasterWall® insulation Panel System On timber/steel frame construction Based on BRANZ Appraisal No 478 Refer to MasterWall for installation details Sto Registration: For StoWarranty the completed specification must be registered with Stoanz Australia Ltd. Email to [email protected] 1. PROJECT DETAILS Specifier: Project & Address: Project Owner: Sto Warranty: Sto 15 Year with StoService Assurance StoTherm Vario Render over MasterWall® Insulation Panel System on timber/steel frame construction This specification details the application of the StoTherm Vario Render System consisting of, StoLevell Novo meshed basecoat render, Stoplex W primer, selected Stolit coloured finishing render coated in selected StoColor facade paint on MasterWall® Insulation Panel System over timber or steel framed construction in accordance with Australian Building Code National Construction Code (NCC). Select Finishing Render: --Click to select-- Select Facade Coating: --Click to select-- Specification Number: Office Use Only i.e. 16.01_StoReg tec_sales_SS105_project address Project Notes: The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 1 Sto Specification Australia SS105 StoTherm Vario on Masterwall® Insulation Panel 2. CONSTRUCTION & DETAILING Responsibility All work in this section shall be the responsibility of the Main Contractor, unless previously agreed in writing. Stoanz Australia Limited accepts no responsibility for defective workmanship in relationship to the application of the Sto system, or for defects in the design, construction, or condition of the building, either as built or in relation to the works. The Main Contractor is to ensure that they are fully conversant with exterior legislation requirements, the project specifications and details, MasterWall® Insulated Panel System Installation & Construction Details Manual and any specific installation requirements relating to the Main Contractor’s responsibilities before any works commence. The Main Contractor is also responsible for the various subcontractors to ensure that all items relating to weathert lightness, penetrations and dissimilar material junctions affecting the construction system are strictly in accordance with project specific details, manufacturer’s instructions and details i.e. items such as roofs, soffits, openings, lights & security fittings, electrical wiring, flashings, deck membranes dissimilar junctions etc. that abut, flash or penetrate the system. The Main Contractor shall also ensure that the window and door joinery is installed in accordance with the project drawings and MasterWall® joinery details. A Masterwal®l cladding QA and StoService Quality Assurance Document is to be filled out as a record of the work undertaken by the Sto Contracting Company. Timber Frame Timber framing must comply with the National Construction Code (NCC) for buildings or parts of a building within the scope limitations. All framing shall be true in vertical and horizontal planes with particular attention to intersections between top plate, floor joists and bottom plate in multi-storey construction. Adequate timber framing including noggins and blocking shall be provided by the Main Contractor to facilitate cladding fixings for the designated wind zone, membrane upstands, dissimilar materials and exterior fixtures on the cladding. The timber grade and level of treatment shall be in accordance with the AS/NZS 1604 current requirements. Note: Any areas to be supported by blocking are required to be designated / assigned prior to installation and the timber framing blocked as necessary. Steel Frame Steel framing must be to a specific design meeting the requirements of the National Construction Code (NCC) and NASH Au. Wall insulation Wall insulation must meet the group climatic zone insulation requirements in accordance with the ASINZS 4859.1 and the BCA Framing Wrap A vapour permeable wrap meeting the requirements of the National Construction Code (NCC).shall be installed in accordance with the building wrap manufacturer’s instructions. The wall wrap should be returned into the recesses of all openings and double lapped and flashing taped as required. The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 2 Sto Specification Australia SS105 StoTherm Vario on Masterwall® Insulation Panel Soffits Soffits are installed with a 6/8mm bead of MS Sealant installed after the cladding work is completed and before rendering commences. Inclined soffits require a metal flashing. Penetrations and Fittings Penetrations and fittings such as waste pipes, vents etc should slope to the exterior, be adequately supported by blocking and be taped onto the sarking with a square sized flexible flashing tape. Blocking must also be installed for taps, door stops hooks, lights, gas fittings, security alarms with all exterior electrical wiring encased in PVC conduit at a downwards rake of 5 degrees that is sealed with MS Sealant. Aluminium Joinery All windows and doors shall be fitted prior to installation of the cladding by the appointed window installer positioned to sit and be sealed / flashed in accordance with the MasterWall® joinery details. MAIN CONTRACTOR & ALL TRADES INVOLVED IN ANY EXTERIOR WORK All details must be in accordance with the Project drawings and details 3. MASTERWALL® PANEL INSTALLATION Responsibility All work in this section shall be the responsibility of the Cladding Contractor who shall check that the timber or steel frame construction is acceptable before proceeding with the installation of the MasterWall® Insulated Panel System. The Cladding Installer is to ensure adequate protection apparel and equipment is supplied to meet their responsibilities in regards to the Health and Safety regulations and that all dissimilar and adjacent surfaces are masked off and protected. MasterWall® Insulation Panel System Shall be installed in accordance with the MasterWall® System Installation & Construction Detail Manual, specifications and details using MasterWall fixings, tapes, adhesives, uPVC etc. Before commencing check the framing is straight adequate studs, blocking and noggins have been installed to securely fix the panel system and fitting or fixtures detailed in the project drawings. All panel joins must be adhesively foamed and the selected joinery must be installed to sit over the MasterWall® opening reveals that have been waterproofed in accordance with the MasterWall® details. On completion of the MasterWall® installation rasp back all joints to remove any adhesive foam residue and check all openings are correctly detailed before commencing any rendering. Note refer to Masterwall® details and specifications before commencing for fixing centres, instillation details and complete a Masterwall® QA as a record of work. Control & Interstorey Joints Vertical control joints are required on walls over 20 metres long, where the system abuts dissimilar material or overlays different construction material. Horizontal interstorey joints are required at all mid floor junctions in accordance with the MasterWall® System & Construction Detail Manual and specifications. The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 3 Sto Specification Australia SS105 StoTherm Vario on Masterwall® Insulation Panel Sealant Shall be paintable MS Sealant used strictly in accordance with the Manufacturers Technical Data Sheet. Rendered Parapets and Balustrade Caps For rendered parapet and balustrade caps refer to the MasterWall® Skyline System to provide a waterproof membrane system. Architectural Profiles & Shapes Architectural shapes used to create decorative detailing shall be correctly cut to size and fitted using StoFlexyl mortar notch towelled to the back of the shape prior to placing. As required construction fixings are used to mechanically fix large or heavy shapes but care is required to avoid distortion. Joins are butted together using Sto Crack filler and any control joints must be mirrored through the profile. Profiles shall be pre-meshed or receive a StoArmat mesh coat and are placed after the mesh coat with top edges meshed to the wall. 4. STOTHERM VARIO RENDER INSTALLATION Responsibility All work in this section shall be the responsibility of the Sto Contractor who must assure themselves that the surfaces to be rendered are dry, free of contamination and satisfactory before work commences. Adequate protection of all adjacent surfaces shall be undertaken prior to commencing. General Rendering shall be carried out in stages over the Masterwall® cladding incorporating; StoLevell Novo meshed basecoat render over the panels sealed with Stoplex W sealer, selected Stolit coloured finishing render coated in selected StoColor facade paint. Materials Stoanz Austrlai Ltd supplies all the following materials StoLevell Novo meshed basecoat Sto Stoplex W sealer Selected Stolit K coloured finishing renders Sto uPVC pre meshed corner angles, finishing edges and drip edges. Selected StoColor facade paint StoFlexyl waterproofing Detailing: Sto uPVC pre meshed finishing edges, drip edges and corner angles are available as required. StoLevell Novo meshed basecoat render To clean dry secure insulation panels apply a base coat of StoLevell Novo render by hawk and trowel at approximate thickness of 5.0mm. While the render is still wet, lightly embed the Sto reinforcing mesh ensuring adjacent drops of mesh are overlapped by a minimum 75mm and float the surface to ensure the mesh has been embedded before reinforcing all openings with mesh butterflies on top of the mesh coat and apply a second coat of StoLevell Novo to ensure the mesh is fully covered. Once dry remove any slight ridging etc. of the rendered surface with a Sto rasp to achieve a flat plane surface. The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 4 Sto Specification Australia SS105 StoTherm Vario on Masterwall® Insulation Panel Sto Stoplex W primer To clean dry StoLevell Novo surface apply one coat of Stoplex W primer by brush and roller to seal the surface at approximately 10m² per litre. Sealant Installation After the sealer has dried, all render junctions between joinery and adjacent dissimilar surfaces and around penetrations shall be sealed with MS Sealant. Float Finished Renders Note: refer to header for selected finish Stolit K texture is available in 1.0, 1.5, 2.0 or 3.0mm aggregate as selected Stolit K coloured finishing render as selected To all exterior rendered surfaces apply the selected Stolit K coloured finishing render with a stainless steel trowel gauging to the thickness of the aggregate size and finished with a plastic float to the requisite pattern and allow to dry normally overnight. The spreading rate shall be approximately 12sqm/1.0mm, 9sqm/1.5mm, 7sqm/2.0mm and 4sqm/3.0mm -/per pail. StoColor facade paint selected All Stolit K surfaces shall receive one (1) full coat of StoColor façade paint tinted to the selected colour and applied by brush and roller at approximately 6/7 m² per litre. Note: Always maintain wet edges between cutting in and roll in tight to ensure an even film build is maintained. 5. GENERAL NOTES Colour As selected by the client or specifier Stoanz Limited recommends that the selected colour must have a minimum Light Reflectance Value of 35%. Where a colour less than 35% LRV but not less than 25% is selected two coats of StoColor X-black heat reflective facade are required. Colours selected below the recommended values will affect the warranty. 6. STOSERVICE ASSURANCE Refer; StoService Assurance for comprehensive guide The Sto Render System should be cleaned annually by low pressure washing or hosing down to remove surface contaminants with special attention to non-rain washed areas (as required use a proprietary house wash sprayed on first with a low pressure garden spray). When recoating is required at the 9 - 10 year period to maintain long-term integrity this is carried out using StoColor façade paint over a cleaned surface. Where a colour change is required Stoanz Limited should be consulted for a specific specification. An annual visual inspection is to be undertaken by the owner or their agent to check for any physical damage or defects in the cladding or exterior building elements to ensure any obvious faults are identified and repaired. Every two and half years the building occupier will be notified to contact the Sto Contractor to carry out a StoService inspection. On completion the Sto Contractor will issue a current StoService certificate that will be recorded in the Sto warranty information so a longterm record of the service history is maintained. The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 5 Sto Specification Australia SS105 StoTherm Vario on Masterwall® Insulation Panel 7. WARRANTY Sto 15 Year Warranty The StoTherm Vario Insulation System described in this specification is warranted for a period of fifteen (15) years from the date of practical completion. This is to comply with the relevant clauses in the Australian Building Code; for this type of building element provided maintenance requirements as set out in the StoService documents are followed. The warranty is supplied by the Sto Contractor on completion with a five (5) year workmanship warranty signed off on completion of the work. The warranty document and the material warranty is issued by Stoanz Australia Limited provided that; (a) All specified work is carried out by the approved Sto Contractor who must complete and sign the Sto Quality assurance and the PS3 Workmanship Warranty (b) All work is carried out in accordance with this Specification or any written amendments issued by the Manufacturers. (c) The warranty does not cover situations where the render system is subjected to physical disturbance, chemical spillage or interference. 8. DISCLAIMER The information contained in this specification is based on our findings, experience, testing and certification at the revision date. End users are still responsible for establishing the suitability of the specified products in regards to their intended use. No liability is undertaken for use of this information outside of Stoanz Australia Limited control or for the substrates and site conditions that are outside of Stoanz Australia Limited’s parameters. Where a Sto registered contractor applies Stoanz purchased products in accordance with a the specifications, TDS sheets and details a Sto Warranty document is available but must be serviced in accordance with the StoService documentation. Stoanz reserve the right to alter or update information and formulations at any time without prior notice. The StoWarranty requires the completed specification to be registered with Stoanz Australia Ltd. Email [email protected] Stoanz Australia Ltd | Authorised Partner of Sto | 7 Mitchell Street, Marrickville, Sydney, NSW, Australia Ph: +61 2 9560 9589 Fax: +61 2 9572 6003 Email: [email protected] Rev No: 7 pa-16.04 Copyrights© Stoanz Australia Limited 6
© Copyright 2026 Paperzz