Honeywell.com 2015 Honeywell Channel Partner Conference - EMEA New Experion HS R430 & Latest HC900 Capabilities Frédéric Gourisse 1 Document control number Honeywell Proprietary User Needs & Challenges • Ease of operations – Seamless communication and integration with complex network of multiple 3rd party DCS, PLC’s and RTU’s for plant wide data exchange • Easy communication – Communication and integration with wide variety of third party PLCs, DCSs, RTUs etc • Economic scalability – From a few hundred to 1000’s of IO points, from a single node to hundreds of stations for geographically dispersed applications • Compliance – Compliance to various standards and communication protocols such as 21CFR part 11 for documentation, change management, and data exchange with IED devices Complex industry challenges 2 © 2015 Honeywell International All Rights Reserved Honeywell Solution Overview Experion® HS is a powerful intuitive software platform that incorporates innovative applications for Human Machine Interface (HMI) and supervisory control and data acquisition (SCADA). It comprises a subset of Experion PKS components specifically packaged to provide a targeted and robust system for small to medium automation projects. Mining Applications • Environmental chambers • Dryers, autoclaves and freeze dryers • Galvanizing plants, heat treatment furnaces and kilns • Pharmaceutical ovens and fermenters • Cement plants • Polystirol plants • Catalyst pilot plants • Extrusion units • Food & beverage manufacturing units • Turbine monitoring Spread across industries and applications 3 © 2015 Honeywell International All Rights Reserved Value Proposition Ease of configuration and ease of use ensure projects can be implemented quickly and efficiently Expand as your operations expand and Integrate easily using Honeywell’s Matrikon OPC Server Easy to use Reliable High performance, stable and secure software Experion HS Scalable Flexible Efficient Experion HS successfully addresses a large variety of application requirements Superior alarm management and plant wide data thus improving operator efficiency Reliable, flexible and easy to use 4 © 2015 Honeywell International All Rights Reserved Experion HS R430 1 DSA from HS R430 • DSA with – Publish and subscribe to other HS R430 or above HS systems – Subscribe from lower releases of HS – Publish and subscribe to PC/LX – Only publish to EPKS • DSA up to 5 other systems DSA reduces error and lowers cost of engineering 5 © 2015 Honeywell International All Rights Reserved Experion HS R430 2 OPC Alarm & Event Server The OPC Alarm & Event Server is designed to expose Experion Alarm & Event data in an open manner to OPC clients that require this information. Reduces errors in integrating data with Experion 6 © 2015 Honeywell International All Rights Reserved Experion HS R430 3 IEC 61850 • IEC 61850 protocol interface • SCADA interface regularly used for power, T&D applications Lower integration costs with IED devices, drives 7 © 2015 Honeywell International All Rights Reserved Experion HS R430 4 Alarm Shelving, Dynamic Alarm Shelving, Suppression, Alarm tracking Lowers operations risks and improves operator efficiency 8 © 2015 Honeywell International All Rights Reserved Experion HS R430 5 HMI Web Solution Pack Easy library lowering engineering costs 9 © 2015 Honeywell International All Rights Reserved Experion HS R430 6 Equipment Templates Points Algorithms Displays Trends Relationships Key Parameters Task Filters Comms Templates reduce engineering efforts and cost 10 © 2015 Honeywell International All Rights Reserved Experion HS R430 7 Gas Operations Suite Flow Total Calculations Gas Quality Calculations Line Pack Basic Leak Detection Compressor Map Reduced engineering for gas operations 11 © 2015 Honeywell International All Rights Reserved Experion HS R430 • • • • 8 OPC Browse Improved engineering ease of use Simplified topology, eliminate PC gateways Associate all relevant parameters to point Improved system alarming with PLC Include: • Direct reference to ControlLogix tags and tag structures & browsing PLC namespace • Direct interface to PLC from Experion server • New ‘non-scanned parameters’ to access point related PLC information, eg config options, drive details Reduce engineering cost and minimize errors 12 © 2015 Honeywell International All Rights Reserved Experion HS R430 9 Experion HS R410 Capabilities Carried Forward Operating system MS office Point count Redundancy HC900 Virtualization RDM Station & server Masterlogic Same hardware requirements, product integration, scalability 13 © 2015 Honeywell International All Rights Reserved Controller Offline History backfill adds reliability and reduces risk 14 © 2015 Honeywell International All Rights Reserved Honeywell.com HC900 1 15 Document control number Honeywell Proprietary HC900 – What and Where Are We Selling? Where Are We Selling? What Are We Selling? Chemicals, Pharmaceuticals & Cosmetics Heat Treatment HC900 Food and Beverage Honeywell HC900 is used for applications ranging from process PLCs to DCSs and safety applications such as BMS, ESD, spill prevention, etc Power (Fossil) Power (Fossil) O&G, Refining Water / Waste water Mining & Metals Pulp & Paper Cement & Glass ….various verticals requiring SIL2 Major Applications • Safety applications like burner management systems, combustion control, emergency shutdown, spill prevention • Critical control applications A single flexible system for process and safety applications 16 © 2015 Honeywell International All Rights Reserved Safety and Non-Safety in Separate Systems 900 Control Station Experion HS with Dual Ethernet Safety System Process Control C75 CPUs C70 CPUs C75S (dual networks) A single flexible system for safety & process control Faster start-up time, common engineering tools, reduced training, simplified maintenance and lowest cost of ownership 17 © 2015 Honeywell International All Rights Reserved Addressing the Challenge Safety and Non-Safety in Separate Systems 900 Control Station Experion HS with Dual Ethernet C75S (dual networks) Safety I/Os Non-Interfering Process I/Os Modular, Scalable And Expandable Safety and non-safety I/O’s possible Modular, Scalable And Expandable 18 © 2015 Honeywell International All Rights Reserved Latest Capabilities 2 Honeywell Proprietary Version Control Value – Easy tracking, de-bugging. Revert back to earlier versions. Save dollars for a separate version control offering. 20 © 2015 Honeywell International All Rights Reserved Change Management Value – Manage versions, track and compare. Easier troubleshooting thus reducing maintenance costs. 21 © 2015 Honeywell International All Rights Reserved Configuration Comparison 3 1 2 22 Value – Change management. Save engineering hours in finding previous changes. © 2015 Honeywell International All Rights Reserved Paste Special 3 1 Value – Save 15-20% of engineering efforts 2 23 © 2015 Honeywell International All Rights Reserved Bulk Edit Value – Bulk edit reduces engineering hours 24 © 2015 Honeywell International All Rights Reserved Re-usable Custom Libraries Value – Save engineering time, create logic once and avoid errors 25 © 2015 Honeywell International All Rights Reserved Import Libraries Value – Import custom libraries and replicate. Save engineering hours. 26 © 2015 Honeywell International All Rights Reserved Write Restrictions Value – Control system access only by authorized systems. Millions saved. 27 © 2015 Honeywell International All Rights Reserved Password Protection 1 3 28 2 Value – System intrusion prevented. Millions saved. © 2015 Honeywell International All Rights Reserved Safety Write Value – Reduce additional hardware and engineering costs when writing from HMI or other peer devices 29 © 2015 Honeywell International All Rights Reserved Thank You Honeywell Proprietary
© Copyright 2026 Paperzz