Table of Contents Section 1 Load Centers Class T Fusible Pullouts 1-2 Dimensions 1-2 LOAD CENTERS Fusible Pullouts Circuit Breaker Covers Circuit Breaker Covers 1-3 Dimensions 1-3 © 2009 Schneider Electric All Rights Reserved Air Conditioning Disconnects 1-4 Dimensions 1-4 1 Air Conditioning Disconnects 1-1 Fusible Pullouts Refer to Catalog 1100CT0501 www.schneider-electric.us 1 Class T Fusible Pullouts • • • 2- or 3-pole fusible pullouts 200 A maximum 300 V Class T fuses (not included) 1Ø3W 120/240 V 1Ø2W 240 V 3Ø3W 240 V delta 3Ø4W 240/120 V delta 3Ø4W 208Y/120 V UL Listed 100 kA short circuit current rating • LOAD CENTERS • FTL3200 FTL2200 Table 1.1: Fusible Pullouts Mains System Two-pole Main Wire Size AWG/kcmil Three-pole Rating Cat. No. 1Ø3W 120/240 V 1Ø2W 240 V 100 A FTL2100a 200 A FTL2200a 3Ø3W 240 V delta 3Ø4W 240/120 V delta 3Ø4W 208Y/120 V 100 A — — FTL3100 1000.00 200 A — — FTL3200 1045.00 a $ Price Fuse Pullout Only $ Price Cat. No. $ Price Al or Cu 380.00 — — 4050704950a 128.00 400.00 — — 4050703850a 151.00 4050707050a 196.00 4050705950a 288.00 4–250 Not stocked in PDS. Order point Lexington. Dimensions 3.00 4.46 76 2.96 3.80 76 1.50 1.85 38 80 2.98 57 1.48 3.16 113 2.23 75 97 38 47 1.48 38 .78 20 5.03 3.20 81 3.44 87 6.38 47 2.19 102 4.25 6.61 108 168 (2) .187 Dia. Hole .34 Dia. C'bore .63 16 2.85 72 (4) .187 Dia. Mounting Holes .34 Dia. C'bore, .38 Deep 3.80 56 1-2 4.25 4.00 162 108 1.85 Pull 200A 128 Pull 200A 97 DE5 Discount Schedule © 2009 Schneider Electric All Rights Reserved Circuit Breaker Covers Refer to Catalog 1100CT0501 www.schneider-electric.us Available now from Square D / Schneider Electric are two different versions of rainproof circuit breaker covers which are UL component recognized as being suitable for use as breaker handle covers. They are constructed of durable impact-resistant material and are intended for use by OEMs where a rainproof cover is needed (e.g. on heat pumps and air conditioners with built-in disconnects). Both models have a built-in latch with padlock provisions. The BCH covers are for use on a horizontally-mounted circuit breaker and fit over Square D two-pole QO, QOU, Q2, EH and three-pole Q2 and EH circuit breakers. The BCV covers are for use on vertically-mounted circuit breakers and will fit over Square D two and three pole QO, QOU, Q2, EH, FA and KA circuit breakers. Table 1.1: Covers Quantity 1 1 Cat. No. BCH BCV $ Price 20.50 20.50 LOAD CENTERS Circuit Breaker Covers 1 Dimensions 2.141 4.58 5 116 .30 8 2.50 59 1.32 34 4.82 4.40 122 4.62 112 1.10 117 28 BCH Horizontal Cover © 2009 Schneider Electric All Rights Reserved 28 80 2.33 64 1.09 3.14 BCV Vertical Cover DE2E Discount Schedule 1-3 Air Conditioning Disconnects Class 3150 / Refer to Catalog 3150CT0401 www.schneider-electric.us 1 Air Conditioning Disconnects Table 1.1: Non-Fusible Air Conditioning Disconnect—Pullout Rainproof—UL Listed Metallic Ampere Ratinga Service Cat. No. Non-metallic $ Price Cat. No. Max. Hp $ Price LOAD CENTERS 2 Wire—240 Vac Maximum 60 A UFP222R 170.00 UFP222RNM 191.00 10 G/B FP221R 2 Wire—240 Vac Maximum—with 20 A GFI receptacle 60 A UFP222RGFI 455.00 — — 10 — — 10 G/B GFI Rec. 2 Wire—240 Vac Maximum—with 20 A duplex receptacle 60 A UFP222RD 260.00 G/B Duplex Rec. Table 1.2: Fusible Air Conditioning Disconnect—Pullout Rainproof—UL Listed Metallic Ampere Ratingb Service Cat. No. Non-metallic $ Price Cat. No. Max. Hp $ Price 2 Wire (Pullout and Fuseholder)—240 Vac Maximum G/B 30 A FP221R 161.00 FP221RNM 191.00 3 60 A FP222R 161.00 FP222RNM 191.00 10 Note: Suitable for use as service equipment on 120/240 Vac 1Ø3 wire services if used only on a 1Ø2 wire load; and only when the equipment grounding terminal is replaced with ground terminal kit PK3GTA1. Price $7.60. Dimensions Table 1.3: Box Dimensions H Cat. No. W D in. mm in. mm in. mm QO200TR 6.50 165 4.63 117 3.88 98 QO200TRNM 8.75 222 6.50 165 3.88 98 UFP222R 7.50 191 5.25 133 3.25 83 UFP222RNM 8.75 222 6.50 165 3.88 98 FP221R 7.50 191 5.25 133 3.25 83 FP221RNM 8.75 222 6.50 165 3.88 98 FP222R 8.88 225 5.25 133 3.25 83 FP222RNM 8.75 222 6.50 165 3.88 98 a Does not contain overcurrent protection. Suitable for use on systems with up to 10 kA available fault current at 240 Vac max when protected by a fuse or circuit breaker rated 60 A or less. b Suitable for use on systems with up to 10 kA available fault current at 240 Vac. NOTE: For Repair and Replacement parts: • Go to www.schneider-electric.us • Click on FAQ’s • Enter the device catalog number • Click SEARCH • Look for the information required. 1-4 DE2A Discount Schedule © 2009 Schneider Electric All Rights Reserved
© Copyright 2026 Paperzz