Section 1 - Schneider Electric

Table of Contents
Section 1
Load Centers
Class T Fusible Pullouts
1-2
Dimensions
1-2
LOAD CENTERS
Fusible Pullouts
Circuit Breaker Covers
Circuit Breaker Covers
1-3
Dimensions
1-3
© 2009 Schneider Electric
All Rights Reserved
Air Conditioning Disconnects
1-4
Dimensions
1-4
1
Air Conditioning Disconnects
1-1
Fusible Pullouts
Refer to Catalog 1100CT0501
www.schneider-electric.us
1
Class T Fusible Pullouts
•
•
•
2- or 3-pole fusible pullouts
200 A maximum 300 V Class T fuses (not included)
1Ø3W 120/240 V
1Ø2W 240 V
3Ø3W 240 V delta
3Ø4W 240/120 V delta
3Ø4W 208Y/120 V
UL Listed 100 kA short circuit current rating
•
LOAD CENTERS
•
FTL3200
FTL2200
Table 1.1:
Fusible Pullouts
Mains
System
Two-pole
Main Wire Size
AWG/kcmil
Three-pole
Rating
Cat. No.
1Ø3W 120/240 V
1Ø2W 240 V
100 A
FTL2100a
200 A
FTL2200a
3Ø3W 240 V delta
3Ø4W 240/120 V delta
3Ø4W 208Y/120 V
100 A
—
—
FTL3100
1000.00
200 A
—
—
FTL3200
1045.00
a
$ Price
Fuse Pullout Only
$ Price
Cat. No.
$ Price
Al or Cu
380.00
—
—
4050704950a
128.00
400.00
—
—
4050703850a
151.00
4050707050a
196.00
4050705950a
288.00
4–250
Not stocked in PDS. Order point Lexington.
Dimensions
3.00
4.46
76
2.96
3.80
76
1.50
1.85
38
80
2.98
57
1.48
3.16
113
2.23
75
97
38
47
1.48
38
.78
20
5.03
3.20
81
3.44
87
6.38
47
2.19
102
4.25
6.61
108
168
(2) .187 Dia. Hole
.34 Dia. C'bore
.63
16
2.85
72
(4) .187 Dia. Mounting Holes
.34 Dia. C'bore, .38 Deep
3.80
56
1-2
4.25
4.00
162
108
1.85
Pull 200A
128
Pull
200A
97
DE5
Discount
Schedule
© 2009 Schneider Electric
All Rights Reserved
Circuit Breaker Covers
Refer to Catalog 1100CT0501
www.schneider-electric.us
Available now from Square D / Schneider Electric are two different versions of rainproof circuit breaker covers which
are UL component recognized as being suitable for use as breaker handle covers.
They are constructed of durable impact-resistant material and are intended for use by OEMs where a rainproof cover is
needed (e.g. on heat pumps and air conditioners with built-in disconnects). Both models have a built-in latch with
padlock provisions.
The BCH covers are for use on a horizontally-mounted circuit breaker and fit over Square D two-pole QO, QOU, Q2,
EH and three-pole Q2 and EH circuit breakers.
The BCV covers are for use on vertically-mounted circuit breakers and will fit over Square D two and three pole QO,
QOU, Q2, EH, FA and KA circuit breakers.
Table 1.1:
Covers
Quantity
1
1
Cat. No.
BCH
BCV
$ Price
20.50
20.50
LOAD CENTERS
Circuit Breaker Covers
1
Dimensions
2.141
4.58
5
116
.30
8
2.50
59
1.32
34
4.82
4.40
122
4.62
112
1.10
117
28
BCH
Horizontal Cover
© 2009 Schneider Electric
All Rights Reserved
28
80
2.33
64
1.09
3.14
BCV
Vertical Cover
DE2E
Discount
Schedule
1-3
Air Conditioning
Disconnects
Class 3150 / Refer to Catalog 3150CT0401
www.schneider-electric.us
1
Air Conditioning Disconnects
Table 1.1:
Non-Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Metallic
Ampere
Ratinga
Service
Cat. No.
Non-metallic
$ Price
Cat. No.
Max. Hp
$ Price
LOAD CENTERS
2 Wire—240 Vac Maximum
60 A
UFP222R
170.00
UFP222RNM
191.00
10
G/B
FP221R
2 Wire—240 Vac Maximum—with 20 A GFI receptacle
60 A
UFP222RGFI
455.00
—
—
10
—
—
10
G/B
GFI Rec.
2 Wire—240 Vac Maximum—with 20 A duplex receptacle
60 A
UFP222RD
260.00
G/B
Duplex Rec.
Table 1.2:
Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Metallic
Ampere
Ratingb
Service
Cat. No.
Non-metallic
$ Price
Cat. No.
Max. Hp
$ Price
2 Wire (Pullout and Fuseholder)—240 Vac Maximum
G/B
30 A
FP221R
161.00
FP221RNM
191.00
3
60 A
FP222R
161.00
FP222RNM
191.00
10
Note: Suitable for use as service equipment on 120/240 Vac 1Ø3 wire services if used only on a 1Ø2 wire load;
and only when the equipment grounding terminal is replaced with ground terminal kit PK3GTA1.
Price $7.60.
Dimensions
Table 1.3:
Box Dimensions
H
Cat. No.
W
D
in.
mm
in.
mm
in.
mm
QO200TR
6.50
165
4.63
117
3.88
98
QO200TRNM
8.75
222
6.50
165
3.88
98
UFP222R
7.50
191
5.25
133
3.25
83
UFP222RNM
8.75
222
6.50
165
3.88
98
FP221R
7.50
191
5.25
133
3.25
83
FP221RNM
8.75
222
6.50
165
3.88
98
FP222R
8.88
225
5.25
133
3.25
83
FP222RNM
8.75
222
6.50
165
3.88
98
a
Does not contain overcurrent protection. Suitable for use on systems with up to 10 kA available fault current at 240
Vac max when protected by a fuse or circuit breaker rated 60 A or less.
b
Suitable for use on systems with up to 10 kA available fault current at 240 Vac.
NOTE: For Repair and Replacement parts:
• Go to www.schneider-electric.us
• Click on FAQ’s
• Enter the device catalog number
• Click SEARCH
• Look for the information required.