Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 1. Release version and download file name The newly released program version and download file name is as follows. [Release version] <55C-6e/45C-6e MFP firmware> Model Program Name 55C-6e/45C-6e MFP firmware Current Ver. G20-E4 New Ver. G20-G9 <55C-6e/45C-6e Voice Data> Model Program Name 55C-6e/45C-6e Voice Data Current Ver. 51 New Ver. 52 <55C-6e/45C-6e Drivers/Application> Model Program Name 55C-6e/ 45C-6e PCL Printer Driver for Windows Server2003/ Server2003R2/Vista/ Server2008/Server2008R2/7/ Server2012/Server2012R2/8/8.1 PostScript3 Printer Driver for Windows Server2003/ Server2003R2/Vista/ Server2008/Server2008R2/7/ Server2012/Server2012R2/8/8.1 FAX Driver for Windows Server2003/Server2003R2/ Vista/Server2008/ Server2008R2/7/ Server2012/ Server2012R2/8/8.1 PageMaker PS-PPD XPS Printer Driver for Windows Vista/Server2008/ Server2008R2/7/Server2012/ Server2012R2/8/8.1 PCL Mono Printer Driver for Windows Server2003/ Server2003R2/Vista/ Server2008/Server2008R2/7/ Server2012/Server2012R2/8/8.1 PostScript3 Mono Printer Driver for Windows Server2003/ Server2003R2/Vista/ Server2008/Server2008R2/7/ Server2012/Server2012R2/8/8.1 XPS Mono Printer Driver for Windows Vista/Server2008/ Server2008R2/7/Server2012/ Server2012R2/8/8.1 MacOS 9 PS-PPD MacOS X (Version 10.2.x) PS-PPD Konica Minolta Confidential Program File Name A5C10Y0-F000-G20-G9.exe Program File Name A5C10Y0-C100-G00-52_Voice(Function_Vers ion6).exe Current Ver. New Ver. 4.1.0.0 5.1.3.0 4.1.0.0 5.1.2.0 With WHCK (Win_x86,Win_x64) 4.1.0.0 5.1.2.0 With WHCK (Win_x86,Win_x64) 30000.0001 4.1.0.0 No Change 5.1.2.0 4.1.0.0 5.1.3.0 4.1.0.0 5.1.2.0 With WHCK (Win_x86,Win_x64) 4.1.0.0 5.1.2.0 With WHCK (Win_x86,Win_x64) 30000.0001 4.0.2 No Change No Change 1/15 Download File Name 55C-6_36C-6_Serie s_PS_PCL_FAX_v5 .1.x.0.zip Note With WHCK (Win_x86,Win_x64) 55C-6_36C-6_Serie s_XPS_v5.1.2.0.zip With WHCK (Win_x86,Win_x64) 55C-6_36C-6_Serie s_PS_PCL_XPS_M ono_v5.1.x.0.zip With WHCK (Win_x86,Win_x64) 55C-5_36C-6_Serie s_MacOS_v5.0.0.zi p Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) MacOS X (Version10.3.x , 10.4.x) PS-PPD MacOS X (Version 10.5.x) PS-PPD MacOS X (Version10.6.x) PS-PPD MacOS X (Version10.7.x) PS-PPD MacOS X (Version10.8.x) PS-PPD MacOS X (Version10.9.x) PS-PPD Real-Time Mode TWAIN Driver HDD TWAIN Driver 4.0.2 No Change 4.1.0 No Change 4.1.0 No Change 4.1.0 5.0.0 4.1.0 5.0.0 4.5.3 5.0.0 4.0.12100 4.0.12100 4.0.16000 4.0.16000 2014/07/17 Supported MacOS10.4 (PPC/Intel) Supported MacOS10.5 (PPC/Intel) TWAIN_v4.0.16000. zip [Download File Name] A5C10Y0-F000-G20-G9.exe A5C10Y0-C100-G00-52_Voice(Function_Version6).exe 55C-6_36C-6_Series_PS_PCL_FAX_v5.1.x.0.zip 55C-6_36C-6_Series_XPS_v5.1.2.0.zip 55C-6_36C-6_Series_PS_PCL_XPS_Mono_v5.1.x.0.zip 55C-5_36C-6_Series_MacOS_v5.0.0.zip TWAIN_v4.0.16000.zip 55C-6e_Series_PRI_DLBT1412035EN_0.doc 2. What changed 2.1. Release of 55C-6e/45C-6e (Mass-Production Program Function Version6 Ver.G20-G9) The individual files and the checksum are as follows. Program Name File Name Checksum MFP Card Version A5C10Y0-F000-G20-G9 MFP Controller BOOT Program A5C10Y0-1E00-G00-04 7CD6 Linux-based MFP Controller Linux-2.6.26.8-rt16 F801 MFP Controller Kernel Program A5C10Y0-1C00-G00-61 38E0 MFP Controller Subset A5C10Y0-1F00-G00-J2 484F MFP Controller A5C10Y0-0100-G20-G9 9436 MFP Controller System A5C10Y0-1000-G20-G9 MFP Controller Print Controller A5C10Y0-3000-G01-04 MFP Controller Print Controller Font A5C10Y0-3F00-G01-00 MFP Controller Print Controller Demo Page A5C10Y0-3E00-G00-81 MFP Controller MIO A5C10Y0-5000-G00-H4 MFP Controller PIC A5C10Y0-8200-G00-B1 MFP Controller Thread Image Parameter A5C10Y0-8B00-G00-01 040C MFP Controller PIC Image Parameter A5C10Y0-8A00-G00-01 046B Scanner A5C10Y0-0023-G00-30 BAA2 Printer (55C-6e) A5AY0Y0-0050-G00-26 F18B Printer (45C-6e) A5C00Y0-0050-G00-26 68CE FAX board controller A22M0Y0-4000-G00-08 0CC9 Operation panel message data A5C10Y0-8100-G00-G0 033E ADF (DF-701) A3CE0Y0-0024-G00-10 EDE1 Finisher (FS-533) A2YU0Y0-0071-G00-08 C3B1 Finisher (FS-534) A3EP0Y0-0071-G00-19 7901 Finisher (FS-535) A2Y10Y0-00N1-G00-25 4916 Konica Minolta Confidential 2/15 Note Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 JS-506 SD RU ZU COPY PROTECT Movie Data Voice Data Panel Sound Data Dictionary Data Engine Parameter (55C-6e) Engine Parameter (45C-6e) A2YV0Y0-0070-G00-01 A3ER0Y0-0071-G00-08 A2Y10Y0-00R1-G00-07 A1090Y0-00H1-G01-12 --A5C10Y0-C000-G00-30 A5C10Y0-C100-G00-52 A5C10Y0-C200-G00-00 A5C10Y0-B100-G00-00 A5AY0Y0-0054-G00-00 A5C00Y0-0054-G00-00 B1E3 D58E 6900 C49E D805 40E1 24E1 24BA 2.2. Fixed issues 2.2.1. Addition of function/ Change of specifications 1. The function for Control of OpenAPI is enhanced. 2. The character encoding setting for Web Browser is supported. 3. Printing jobs without Windows Login ID + password under the Enhanced Server authentication is supported. 4. The deletion settings for Cache, Cookie and Authentication information conditions on Web Browser are changed. 5. Server-less Ubiquitous Print is supported. 6. Input functions of Scan/Fax address settings, etc. are added. 7. The Panel Keyboard layout can be arranged according to languages. 8. When error occurs, Network Error code is displayed. 9. Remote Panel screen is improved and Remote Panel can be started from CSRC. 10. Simultaneous settings (ex. the network settings) can be applied for MFPs. 11. The function of toner coverage accounting is supported. 12. English is supported to be displayed on the system reboot screen of C-D390. 13. The operation sound for Web Browser is supported. 14. SSD FW version will be displayed in the top right corner of the Firmware Update screen. "NG" will be displayed for the SSD Download result if the SSD FW is 6.02n. If the SSD FW is 6.03m, "Completed" will be displayed for the result (The SSD FW will be updated). If the SSD FW is 6.05m, nothing will be displayed. 2.2.2. The following issues are solved in this firmware. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. The message "The specified box does not exist" may be displayed on the WebConnection screen if the following operations are performed at the same time. - Receive print jobs from PC - IP address fax Rx - Download the document in User Box from WebConnection Preview Key can be operated on "No. of Address Screen" in Search Box of Save in User Box. Bluetooth settings will be displayed on the network tab of WebConnection when FIPS mode is valid. Some part of the character string(s) will not become grayout on the Enhanced Server authentication screen. Some size of OCR font may be different when converted. Under Enlarge display mode, the display shows only the last two characters when trying to open the user name input screen again after a user name has been entered. The preview of program jobs is not displayed correctly. Symbols cannot be entered on the E-mail Address input screen if "ON" is selected for searching forecasted destinations of LDAP Settings. A time-string obtained by IWS is not correct if +8:00 is selected for the time zone of Date/Time Settings. "Image Priority" is set even after scanning with DOCX type with Text Priority for Output Method. Recorded music key will be displayed for BGM Settings unnecessarily. VC command parameter cannot be operated correctly from CSRC Web application. In Enlarge display mode, the message "From Address is not set. Unable to transmit. Please specify the From Address." will be displayed when scanning to registered E-mail addresses with which User Settings were imported if Current Setting is selected for Default Scan/Fax Settings. Konica Minolta Confidential 3/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 14. The last character of a JAM code will not be displayed in Enlarge display mode. 15. The Top Bind icon of Duplex/Combine is not displayed correctly. 16. When entering a Fax TX destination(s) using "Enter Registered No." of Direct Input, the destination(s) will not be cleared off even "Next Dest." is touched. 17. The Program list registered for Favorite will not be displayed correctly when Flash is selected for View Mode on WebConnection. 18. Service mode will be shown when touching the APP button on the top screen after closing Service Mode. 19. Jobs cannot be restarted if No matching paper warning or paper empty occurs using PullPrint application. 20. The "Connecting..." screen will not be displayed if logging in and pressing the Stop button when the Auth application server is down for the Enhanced Server Authentication + the Biometric Authentication device. 21. Auto Search may not run on BoxOperator to find MFPs. 22. "An input error occurs when the following sent: AppReqGetDevicePermanentSetting (Network>Remote Panel>Client>Timeout=5)" 23. "The Box destination of Box No.99999999 cannot be specified for the fax line1-4 in the following setting: Administrator Settings > Fax Settings > Function Settings >Forward TX Setting" 24. Fax jobs will be deleted if the main power switch is OFF/ON before transmitting them when the Forward TX Setting is enabled. 25. The thumbnail button of the User Box may not be displayed on WebConnection. 26. SELECT1 cannot be specified for the Value of SearchSelectionControl on the Auth application. 27. A user/account name(s) in the list of the password encrypting PDF box is garbled. 28. An error will be displayed if "AES-CTR" is enabled for an ESP encryption algorithm for IPsec from WebConnection. 29. The Web Browser registered in Register Key 1 cannot be started if an application is registered in Register Key 3. 30. The display proceeds to the top screen of the user authentication when opening and closing the front door after an IC card is passed over or placed on the card reader. 31. The screen will be garbled if the Utility screen is closed after the Specified Application Start Setting is enabled and the Scan/Fax application is started. 32. The Start key will become blue if Numeric Control (type2) Control is selected on the Custom Settings screen when the Specified Application Start Setting is enabled. 33. The file name(s) transmitted by the TSI User Box function is not correct if Change is selected for the RX File Change Page Name. 34. The Changes Allowed screen will not be shown even the Changes Allowed button is touched in the PDF Detail Setting of the Scan application. 35. The Register Key(s) of the Scan application does not work even touching it when the category screen is shown on the Scan application. 36. The warning message of the Consumable life stop will not be displayed even the consumable life has exceeded the maximum allowance while printing. 37. A warming of opening the front door will not be displayed while an application error is indicated on the display. 38. The power save mode cannot be entered when the biometric authentication registration screen is displayed for the Enhanced Server authentication + the biometric authentication device. 39. C-E301 may occur when FW is upgraded while using My Panel Manager. 40. If User Name is used at "SYSTEM", the user cannot login to WebConnection. ("Authentication Failure" will be shown) [PEBJTS1400708411] 41. Only up to 13 characters are displayed for a client password on the remote panel. 42. The loadable driver and the machine settings (the authentication settings) will not be updated due to C-E301 occurring if the loadable driver and the machine settings (the authentication settings) are updated at the same time by the Machine Auto Update function. 43. "The following issues will occur to timer TX waiting jobs: - The address book included in broadcast destinations is not displayed in the destination detail list. - Job Status is garbled when entering the job detail screen from the destination detail list." 44. The user authentication fails if a user name is registered with the word "CE". 45. The FIPS settings will be displayed even the Enhanced Security Mode is ON. 46. A written error in German for Document Name Auto Extraction button of Searchable PDF Settings is fixed. [RIBDSP1400714949] 47. The scan job may remain forwarding after FTP Scanning is finished. 48. C-E301 may occur if logging in while using My Panel Manager. Konica Minolta Confidential 4/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 49. The status may be kept at 99% when Overwrite Temporary Data is performed. 50. A panel lock may occur if disconnecting to bizhub RA after a user authentication failure has occurred. 51. "Printing does not work even ON is selected for the following items in the Application of the copy function: - Date/Time - Page Number" 52. The machine auto update will not start even the specified update time has come while the MFP is in the Deep Sleep mode. 53. If printing the black file including PCL Command (Escape &b1M) by LPR command, the job is counted as Color job.[PEBF__1300673822] 54. If printing many Print Jobs, the printing preference may be changed. (When printing the job with 2-Sided printing, one-side may not be printed.) [PEBJTS1300681865] 55. When printing a job from AS400, Print Job is deleted. [PEBNO_1300678003] 56. The printing job will not be started even pressing [Start] button after confirming the Proof Copy. [PEBGB_1400706556] 57. Button of Scan/FAX Address Book Registration screen will slip out of intended place when it comes via Guide menu. [PEBJOS1300696400] 58. An English written error in the deletion confirmation screen of the PullPrint application is fixed. [RIBUS_1400717699] 59. When an IC Card Reader is connected, the message displayed by an Authentication Application will be changed to FW standard message. [PEBNZ_1300671382] 60. The settings of the Overwrite User Info for the User Authentication cannot be imported. 61. Manually received documents with handset and off-hook will not be transmitted by the TSI User Box function if ON is selected for Individual Receiving Line Setup. 62. Characters will be garbled if the document name, subject and body of an E-mail are entered with 4-bytes Chinese font from IWS. 63. The icons of IWS application logos registered in the MFP are dislocated towards the left side of the top menu. [RIBJSL1400702108] 64. The sender printed on a Fax will be garbled if Other 3 is selected for the Market Area. 65. The setting does not return to the one which has been specified earlier in the Encryption settings for the PDF Detail Setting on the Scan application even touching the Cancel Key. 66. The MFP will be hanged up if 31 or more bytes of the character are entered for File Name/Subject Name/Other settings on Scan/Fax. 67. The following symptom will occur if ON is selected for the Confirm Address (Register): - The Start Key will not be accepted even Fax destinations have already been entered if Fax destinations are entered on the Confirm Address screen." 68. The settings changed will not be applied even specified in the Address Details of the Check Setting when sending documents in the User Box by IP address fax. 69. USB cannot be accessed if an application is restarted after referring to the Administrator Password from IWS. [PEBEU_1400706908] 70. SRA3 will not be displayed in the Print Setting for Mobile/PDA. 71. Alphanumeric keys will not be displayed on the top screen of the Browser Authentication under the following settings: Language Selection: Japanese Panel Keyboard Language Selection: Panel Display Language Synchronize Select Keyboard: Local Keyboard 72. The scanned data cannot be sent under the following setting because the message "Cannot connect to the network." will be shown if Scan to WebDAV is performed: Server Auth. Character Code: Windows Code Page 73. When transferring a received G3-FAX to the products of other companies by IFAX/IP-FAX, RX error will occur. [PEBJOS1400714840] 74. Only two characters will be shown on the MFP if a user name and a password are entered with IME on the tablet terminal. 75. The entered characters will not be shown on the MFP unless the enter key is touched with IME on the tablet terminal. 76. An error may occur and WSD scan may be finished if WSD scan is performed with IPv6. 77. Total Counter Notifications may not be sent according to the schedule. 78. 23rd or later characters in the E-mail subject will not be displayed correctly in Korean. 79. When printing a specific PDF, some characters will not be printed correctly. [PEBJHK1400698800] 80. A specific PDF file will not be printed correctly from PS driver. [PEBF__1300695720] 81. When printing an Excel file using Courier fonts from Max OSX, PS error will occur. [PEBDFS1300686778] 82. When printing data with barcodes in, PS error will occur. [PEBBE_1400704401] Konica Minolta Confidential 5/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 83. 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. 103. 2014/07/17 When printing special characters of Palatino fonts from Mac OS, an error will occur. [PEBF__1400713047] MFP may not receive print jobs while the MFP is in Low Power mode. The BEU localize languages cannot be installed as intended. [PEBEU_1400715683] The version of Printer Controller DemoPage will be changed if the function version is changed. When files are created by Scan to DOCX, the text boxes will overlap. [RIDVRF1300681469] The job may not be deleted and remained after ID&Print job is printed out. [ERBJTS1400724757][ERBJTK1400722917][ERBJTK1400725092][ERBJTK1400725490][ERBJTK1400726791] A warning will not be displayed even the Memory RX User Box Password of the Memory RX setting is not specified when the Individual Receiving Line Setup is ON. Jobs may not be received if in the Deep Sleep mode. The Trail Edge Adjust cannot be specified for postcard in the Administrator mode. The S/N of Status Notification will not be notified correctly. Controller JAM (99-02) may occur if jobs are received while in the Sleep mode. If sending a fax from DF-701, a line is printed. [PEBD__1300681278] A barcode may not be printed correctly. When printing a vertical text document of MS Word file with 2in1 or 6in1, the staple position is not stapled correctly. When printing Encryption PDF file with N in 1 file by direct print, the data light keeps flashing. When printing an OOXML file by direct print, C-E301 may occur. When printing a specific PDF file by direct print, the data light keeps flashing. C-FA14 may occur when receiving an IP-Fax and a PC print job. A hatching Image will be lost partially if printing from Adobe Illustrator CS6. When printing an OOXML file by direct print, MFP may hang up. Add the capability to upgrade SSD internal FW while MFP FW downloading and complement the processing of SSD internal block substitution. 2.2.3. The following issues are solved in this driver. 1. 2. 3. 4. Overlay files can be specified with different resolutions on PS driver. The performance will become slow while downloading a printer driver if the Mac PC has multiple user accounts. The driver cannot be installed if selected language is different from the OS language. In the environment of Citrix Receiver 4.x + CitrixUPD, the output will be the paper size selected on a client PC if printed via a PCL driver under the following settings. Or, a PCLXL error will be output if any paper size is selected via CitrixUPD when the "Same as Original Size" is chosen on a client PC: 1200dpi (Rasterize on PC) 1200dpi Rendering Op.: None 3. Functional restrictions 1. If the main switch is turned OFF and ON while saving the Fax job in User Box, the thumbnail is not displayed correctly for a moment. 2. The following characters can enter into Host name from the control panel. - "." and "-" * Refer to the Readme.txt file which is included in each driver and application for other functional restrictions. * Additional memory installation is required when using the following Open API function. - Initial screen customization Konica Minolta Confidential 6/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4. How to install 4.1. How to install program Use USB memory to install. For the details, see the Service Manual. Conditions for USB memory which can be used for updating the firmware are as follows: - Securities such as data encryption and password lock shall be released, or the security function shall be turned Off. - Memory with 1 GB to 2 GB are recommended (One with 4 GB or more may not operate) - Compatible with USB Version 1.0/2.0 interface - Formatted with FAT32 type - A USB flash memory that appears as multiple drives on a computer cannot be used. 4.2. How to upgrade/downgrade firmware [Definition of terms] Function Version2: Firmware Version ver.Gxx-42 and earlier. Function Version2 MR (Maintenance Release) Version: Firmware for Function Version3 Version ver.Gxx-63 or Gxx-A9. (There are not enhancement functions of Function Version3.) "Function Version2" has equal functions. Function Version3: Firmware for Function Version 3 Version ver.Gxx-63 or Gxx-A9. Function Version2 MR2 (Maintenance Release2) Version: Firmware for Function Version5 Version ver.Gxx-C8 or Gxx-E4. (There are not enhancement functions of Function Version5.) "Function Version2" has equal functions. Function Version3 MR (Maintenance Release) Version: Firmware for Function Version5 Version ver.Gxx-C8 or Gxx-E4. (There are not enhancement functions of Function Version5.) "Function Version3" has equal functions. Function Version5: Firmware for Function Version5 Version ver.Gxx-C8 or Gxx-E4. Function Version2 MR3 (Maintenance Release3) Version: Firmware for Function Version 6 Version ver.Gxx-G9. (There are not enhancement functions of Function Version6.) "Function Version2" has equal functions. Function Version 3 MR2 (Maintenance Release2) Version: Firmware for Function Version 6 Version ver.Gxx-G9. (There are not enhancement functions of Function Version 6.) "Function Version3" has equal functions. Function Version 5 MR (Maintenance Release) Version: Firmware for Function Version 6 Version ver.Gxx-G9. (There are not enhancement functions of Function Version 6.) "Function Version5" has equal functions. Function Version 6: Firmware for Function Version 6 Version ver.Gxx-G9. About Software Switch Settings Switch No.: 25 HEX Assignment: 50 -> Function Version6 HEX Assignment: 40 -> Function Version5 HEX Assignment: 20 -> Function Version3 HEX Assignment: 10 -> Function Version2 [Caution] If older than Gxx-C8 firmware is installed to MFP, Gxx-C8 or later cannot be installed by IISW. Once Gxx-C8 or later firmware is installed by USB memory, Gxx-C8 or later can be installed by IISW. Please set the following settings to default before downgrading. - Delete Machine Image of Customize Screen - Toner coverage accounting Setting Konica Minolta Confidential 7/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.1. Upgrade 4.2.1-1. Firmware upgrading procedure from Function Version2 to Function Version2 MR3 (Maintenance Release3) Version. 1. 2. 3. 4. If the Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Install Loadable Driver for Function Version5 to MFP. 4.2.1-2. Firmware upgrading procedure from Function Version2 to Function Version6. 1. 2. 3. 4. If the Voice Data/Movie Data/Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Movie Data for Function Version3, Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-3. Firmware upgrading procedure from Function Version2 MR (Maintenance Release) Version to Function Version2 MR3 (Maintenance Release3) Version. 1. 2. 3. 4. If the Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Install Loadable Driver for Function Version5 to MFP. 4.2.1-4. Firmware upgrading procedure from Function Version2 MR (Maintenance Release) Version to Function Version6. 1. 2. 3. 4. If the Voice Data/Movie Data/Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Movie Data for Function Version3, Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-5. Firmware upgrading procedure from Function Version2 MR2 (Maintenance Release2) Version to Function Version2 MR3 (Maintenance Release3) Version. 1. 2. 3. 4. If the Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Install Loadable Driver for Function Version5 to MFP. Konica Minolta Confidential 8/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.1-6. Firmware upgrading procedure from Function Version2 MR2 (Maintenance Release2) Version to Function Version6. 1. 2. 3. 4. If the Voice Data/Movie Data/Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Movie Data for Function Version3, Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-7. Firmware upgrading procedure from Function Version3 to Function Version3 MR2 (Maintenance Release2) Version. 1. 2. 3. 4. If the Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Install Loadable Driver for Function Version5 to MFP. 4.2.1-8. Firmware upgrading procedure from Function Version3 to Function Version6. 1. If the Voice Data for Function Version3 and the Loadable Driver for Function Version2 have been already installed, delete them in Service Mode. 2. Install the Firmware for Function Version6 to MFP. 3. Turn OFF/ON the main switch. 4. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-9. Firmware upgrading procedure from Function Version3 MR (Maintenance Release) Version to Function Version3 MR2 (Maintenance Release2) Version. 1. 2. 3. 4. If the Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Install Loadable Driver for Function Version5 to MFP. Konica Minolta Confidential 9/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.1-10. Firmware upgrading procedure from Function Version3 MR (Maintenance Release) Version to Function Version6. 1. If the Voice Data for Function Version3 and Loadable Driver for Function Version2 have been already installed, delete them in Service Mode. 2. Install the Firmware for Function Version6 to MFP. 3. Turn OFF/ON the main switch. 4. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-11. Firmware upgrading procedure from Function Version5 to Function Version5 MR (Maintenance Release) Version. 1. 2. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. 4.2.1-12. Firmware upgrading procedure from Function Version5 to Function Version6. 1. 2. 3. 4. If the Voice Data for Function Version5 has been already installed, delete it in Service Mode. Install the Firmware for Function Version6 to MFP. Turn OFF/ON the main switch. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 5. Turn OFF/ON the main switch. 6. Install Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-13. Firmware upgrading procedure from Function Version2 MR3 (Maintenance Release3) Version to Function Version6. 1. 2. If the Voice Data/Movie Data/Loadable Driver for Function Version2 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 3. Turn OFF/ON the main switch. 4. Install Movie Data for Function Version3, Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. Konica Minolta Confidential 10/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.1-14. Firmware upgrading procedure from Function Version3 MR2 (Maintenance Release2) Version to Function Version6. 1. If the Voice Data for Function Version3 and the Loadable Driver for Function Version2 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 3. Turn OFF/ON the main switch. 4. Install Loadable Driver for Function Version5 and Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.1-15. Firmware upgrading procedure from Function Version5 MR (Maintenance Release) Version to Function Version6. 1. 2. If the Voice Data for Function Version5 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 50 3. Turn OFF/ON the main switch. 4. Install Voice Data for Function Version6 to MFP. Please upgrade the printer drivers for Function Version6 if MFP is upgraded to the Firmware for Function Version6. Because, the Device Information cannot be obtained and other problems may occur. And please also upgrade the Applications. 4.2.2. Downgrade 4.2.2-1. Firmware downgrading procedure from Function Version6 to Function Version2. 1. If the Voice Data for Function Version6, the Loadable Driver for Function Version5 and the Movie Data for Function Version3 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 10 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version2 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data/Loadable Driver/Movie Data for Function Version2 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-2. Firmware downgrading procedure from Function Version6 to Function Version2 MR (Maintenance Release) Version. 1. If the Voice Data for Function Version6, the Loadable Driver for Function Version5 and the Movie Data for Function Version3 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 10 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version3 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data/Loadable Driver/Movie Data for Function Version2 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. Konica Minolta Confidential 11/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.2-3. Firmware downgrading procedure from Function Version6 to Function Version2 MR2 (Maintenance Release2) Version. 1. If the Voice Data for Function Version6 and the Movie Data for Function Version3 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 10 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version5 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data/Movie Data for Function Version2 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-4. Firmware downgrading procedure from Function Version6 to Function Version3. 1. If the Voice Data for Function Version6 and the Loadable Driver for Function Version5 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 20 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version3 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data for Function Version3 and Loadable Driver for Function Version2 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-5. Firmware downgrading procedure from Function Version6 to Function Version3 MR (Maintenance Release) Version. 1. 2. If the Voice Data for Function Version6 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 20 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version5 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data for Function Version3 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-6. Firmware downgrading procedure from Function Version6 to Function Version5. 1. 2. If the Voice Data for Function Version6 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 40 3. Turn OFF/ON the main switch. 4. Install the Firmware for Function Version5 to MFP. 5. Turn OFF/ON the main switch. 6. Install Voice Data (If the version is Gxx-E4 or later please use the Voice Data for MR1) for Function Version5 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. Konica Minolta Confidential 12/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.2.2-7. Firmware downgrading procedure from Function Version6 to Function Version2 MR3 (Maintenance Release3) Version. 1. If the Voice Data for Function Version6 and the Movie Data for Function Version3 have been already installed, delete them in Service Mode. 2. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 10 3. Turn OFF/ON the main switch. 4. Install Voice Data/Movie Data for Function Version2 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-8. Firmware downgrading procedure from Function Version6 to Function Version3 MR2 (Maintenance Release2) Version. 1. 2. If the Voice Data for Function Version6 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 20 3. Turn OFF/ON the main switch. 4. Install Voice Data for Function Version3 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.2.2-9. Firmware downgrading procedure from Function Version6 to Function Version5 MR (Maintenance Release) Version. 1. 2. If the Voice Data for Function Version6 has been already installed, delete it in Service Mode. Change Software Switch Setting to the following in Service Mode. Switch No.: 25 HEX Assignment: 40 3. Turn OFF/ON the main switch. 4. Install Voice Data (If the version is Gxx-E4 or later please use the Voice Data for MR1) for Function Version5 to MFP. Attention: You cannot use the Addition of function/ Change of specifications. 4.3. How to check card version [ROM version]: You can check the ROM version in service mode, "Firmware Version" For the details, see the Service Manual. 4.4. How to install movie data Use USB memory to install. For the details, see the Service Manual. 4.5. How to install voice data The following options are required to use the voice guidance function. - EK-604/ 605 (local interface kit) - i-Option LK-104 v3 Use USB memory to install. For the details, see the Service Manual. 4.6. How to install OCR Dictionary Data for Searchable PDF and PDF/A Font Data Use USB memory to install. For the details, see the Service Manual. i-Option kit is required to use these functions. 4.7. How to install Unicode Font Data and OCR Font Data Install Font Data for USB using USB memory. For the details, see the Service Manual. i-Option kit is required to use these functions Konica Minolta Confidential 13/15 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 4.8. How to install Loadable Driver 1. Extract the attached exe file and save "xxxxxx.tar" file to root directory of USB memory. 2. Insert the USB memory to USB port of MFP. 3. Call the Service Mode to the screen. 4. Touch [System 2] -> [Driver Install]. 5. Touch [SET] and press "Start" button to start installing the data. 6. Check that data is normally installed from the message that appears on the control panel. 7. Turn OFF/ON the main switch. 8. In the Service Mode> Billing Setting> Management Function Choice, select "Card" or "Body" in "Authentication Device2" and press "OK" button. 9. Turn ON/OFF the main switch. For the details, see the Service Manual. 5. Program that recommends applying at the same time Combinations of this program and other latest program versions are as follows. [55C-6e/45C-6e related] Model Program Name Version 55C-6e/45C-6e MFP Card Version G20-G9 55C-6 Series 55C-6 Series 55C-6 Series 55C-6e/45C-6e 55C-6 Series 55C-6 Series 55C-6 Series 55C-6 Series 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e PCL Printer Driver PostScript3 Printer Driver FAX Driver PageMaker PS-PPD XPS Driver PCL Printer Driver Mono PostScript3 Printer Driver Mono XPS Driver Mono Linux PS-PPD MacOS 9 PS-PPD MacOS X (Version10.2) PS-PPD MacOS X (Version10.3/10.4) PS-PPD 5.1.3.0 5.1.2.0 5.1.2.0 30000.0001 5.1.2.0 5.1.3.0 5.1.2.0 5.1.2.0 30000.0001 30000.0001 4.0.2 4.0.2 55C-6e/45C-6e MacOS X (Version10.5) PS-PPD 4.1.0 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e 55C-6e/45C-6e MacOS X (Version10.6) PS-PPD MacOS X (Version10.7) PS-PPD MacOS X (Version10.8) PS-PPD MacOS X (Version10.9) PS-PPD Real-Time Model TWAIN Driver HDD TWAIN Driver Auth Device Tool Advanced for AU-201 Auth Device Tool Advanced for AU-202H Auth Device Tool Advanced for SCL-010 Auth Device Tool Advanced for YSoft CRv2 4.1.0 5.0.0 5.0.0 5.0.0 4.0.16000 4.0.16000 1.2.00000 1.2.00000 1.2.00000 1.2.00000 Konica Minolta Confidential 14/15 Note Supported MacOS10.4(PPC/Intel) Supported MacOS10.5(PPC/Intel) for Function Version5/6 Program Release Information CSES ID-No. DLBT1412035EN Model: 55C-6e/45C-6e MFP firmware Ver.G20-G9 Subject: 55C-6e/45C-6e Mass-Production Program Function Version6 (Ver.G20-G9)(for Web Browser (LK-101v3)) 2014/07/17 6. OpenAPI supported function level The following is OpenAPI supported function level on this firmware. OpenAPI: OpenAPI Function Level 4.6 Detail: Auth 1.0/1.1/2.0/2.1/2.5/3.5/3.6/3.7/4.0/4.1/4.2/4.5/4.6 Scan to Application 2.0/2.1/2.2/3.0/3.1/3.5/3.6/3.7/4.0/4.5/4.6 PullPrint 1.0/1.1/2.0/2.1/2.5/3.5/3.6/4.0/4.5/4.6 Other A 1.0/3.5/4.0 Job Management 1.0/3.5/3.6/4.0 Setup 1.0/1.1/1.2/1.3/2.0/2.1/2.5/3.5/3.6/3.7/3.8/4.0/4.1/4.2/4.5/4.6 Link 4.5/4.6 Web Browser Auth 1.0/1.1/1.5/3.5/3.6/3.7/4.0/4.1/4.2/4.5 Scan to Application 1.0/1.1/3.5/3.6/3.7/4.0/4.1/4.5/4.6 PullPrint 1.0/1.1/1.5/3.5/3.6/4.0/4.1/4.5 ScrSvr 1.0/3.5/4.0 Launcher 1.0/3.5/4.0 General 4.0/4.1/4.5/4.6 7. IWS function level IWS function Level 2.0.3 * Company names and product names in this document are the registered trademarks for respective companies. Copyright(C) 2014 KONICA MINOLTA, INC. Konica Minolta Confidential 15/15
© Copyright 2024 Paperzz