Connectivity Solutions for Distributed Antenna Systems

Connectivity Solutions for
Distributed Antenna Systems
1st Edition
Connectivity Solutions for
Distributed Antenna Systems
1. Introduction................................................................................................................. 1-0
2. Fiber Panels.............................................................................................................. 2-0
3. Fiber Wall Boxes..................................................................................................... 3-0
4. Fiber Optic Splice Closures.............................................................................4-0
5. Fiber Cable Products........................................................................................... 5-0
6. Fiberguide Fiber Management Products................................................. 6-0
7. WDM Chassis and Modules.............................................................................. 7-0
8. Powerworx Fuse Panel Products.................................................................. 8-0
9. Data Connectivity.................................................................................................. 9-0
10. Rack Hardware & Accessories.................................................................... 10-0
11. Miscellaneous...........................................................................................................11-0
12. Index...........................................................................................................................12-0
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Introduction
FLEXIBLE DAS SOLUTIONS
To meet the needs of your DAS network construction and expansion projects to support additional carriers, or to allow for
3G, 4G, LTE migration and beyond, you need a solid physical layer connectivity foundation for your indoor, or outdoor DAS
networks. TE Connectivity offers a complete portfolio of these essential physical layer infrastructure components.
The purpose of this ordering guide is to outline an array of products for interconnection, splicing, termination, and storage of
both electrical and optical components within a typical indoor, or outdoor DAS network.
The products highlighted in this guide are designed to be used in the following applications:
• MSC to BTS fronthaul and backhaul
• Host to remote fiber interconnect
• In-building, and out building fiber cable
• Fiber demarcation, termination and storage
• DAS headends
With the increasing popularity of wireless devices, mobile operators’ customers expect to have coverage anytime, anywhere.
This necessity requires carriers to increase network capacity, which is typically done by adding new cell sites. Extending service
to these hard-to-reach areas can provide challenges. TE's wireless connectivity solutions help increase both coverage and
capacity in high-demand and hard-to-reach locations. TE is revolutionizing the way people communicate through our high
performance and scalable solutions for wireless networking. From extending fiber reach, to increasing indoor and outdoor
coverage and capacity, to providing high-speed wireless backhaul, wireless service providers consistently look to TE for reliable
solutions that increase revenue, lower churn and improve customer satisfaction.
1-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Introduction
TYPICAL INDOOR DAS (IDAS) INSTALLATION
3
1
4
1
Flexible Fiber Box FFB
or
2
Mini RDT
3
1
2
4
2
3
FPX Rack Mounted Fiber
Termination Panel
1
4
2
3
3
1
4
4
2
LSX Rack Mounted Fiber
Termination Panel
2
4
1
3
Fiber Entrance Cabinet
1
1-2
DAS Host Unit
2
DAS Expansion Group
3
Remote Amplifier
Unit (RAU)
4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Antenna
Connectivity Solutions for Distributed Antenna Systems
Introduction
TYPICAL OUTDOOR DAS (ODAS) INSTALLATION
6
5
7
8
9
1
2
1
2
3
11
10
4
1-3
11
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Introduction
1
2
3
Fiber Entrance Cabinet
Flexible Fiber Box FFB
Fiber Demarcation Cabinet
4
5
1 RU Rapid Fiber Panel
6
Fiber Cable Assembly
7
8
178 mm (7")
432 mm (17")
LSX Fiber Panel
UPC LC
10
WDM
1-4
279 mm (11")
LSX Splice Panel
Plugs into port 1
of Fiber 1 ProAx
Note: WDM
comes
preinstalled in the
Remote.
11
Remote WDM Kit
1
9
UPC Bx.5
Plugs into the
SPF in the SeRF
“15” = REV
“13” = FWD
Prism Host Unit
Remote OADM Splice Box and OADM Module
2
FPX Rack Mounted Fiber
Termination Panel
Prism Remote Unit
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Host WDM Module
Fiber Panels
Fiber Termination Panels.......................................................................................... 2-1
FPX Series Rack Mount Fiber Panels................................................................2-3
LSX Optical Distribution Frame...........................................................................2-4
Splice Tray........................................................................................................................2-6
Cable Clamp Kit and Cable Ring Kit.................................................................2-6
2-0
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
Fiber Termination Panels with Rapid Fiber
Rapid Fiber technology is an important innovation in the fiber optic panel market. Serving as a key distribution point between the
DAS Host and the Remote Hubs, the Rapid Fiber panel offers service providers unmatched savings in installation time, labor costs and
performance.
The Rapid Fiber panel employs TE's unique RapidReel payout spool to deploy 12 Fiber Micro cable—which means the intrafacility
cable (IFC) cable is always the right length. Available in 100' increments (up to 1000'), the multifiber cable terminates to a multifiber push-on connector (MPO), which enables a plug-and-play connection to the Remote Hub location. The MPO connector and
multi-fiber cable ensure fast cable routing and easy handling by technicians; and offers maximum space savings for high density
fiber applications.
The Rapid Fiber panel's combination of microcable, RapidReel spool and MPO connector technology in a single panel not
only relieves cable congestion but also simplifies the ordering and inventory of equipment. The panel also features TE's
industry-leading cable management—providing bend radius protection, cable routing paths and physical protection for
optimal network performance.
The Rapid Fiber panel incorporates the latest panel, cable and connector technology—and can help drive down total cost
of installation by as much as 25%.
KEY FEATURES:
PANEL
• RapidReel fiber cable spool ensures IFC cable is always the
right length; available in 100' increments (up to 1000')
• Spool assembly is equipped with a pulling eye
for easy cable routing and installation
• Mounting brackets allow 19" or 23" rack installation
1 RU Rapid Fiber Panel
• Rated for indoor environments—meets UL 1863 and NEBS
Level 3 requirements for central office applications
CABLE
• 12-fiber 3.6 mm indoor/outdoor riser rated cable
terminated with a MPO connector; or
• 12-fiber 3 mm plenum cable with fanout terminated to
single fiber breakouts with SC, or LC connectors
• GR 409 compliant, robust microcable design to fit a
variety of applications and environments
• Reduced bend radius fiber technology provides cable
protection and eliminates concerns around proper handling,
slack storage, and attenuation loss from macro bends
• Multimode cable designed and tested to TIA 568
CONNECTORS
• Low MPO and SC/LC connector insertion loss and return
loss minimizes impact on link loss budget
• Optical connectors designed and tested to GR 326 and GR 1435
• Multimode connectors designed and tested to TIA 568
2-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
TYPICAL APPLICATION OF RAPID FIBER PANEL AND FPX/LSX TO INDOOR DAS DEPLOYMENT
3
4
1
FPX Panel
3
4
2
3
1
1 RU Rapid Fiber Panel
4
2
3
4
1
3
DAS Host Unit
Remote Amplifier
Unit (RAU)
2
4
DAS Expansion Group
Antenna
2
1
ORDERING INFORMATION
Product Description
Part Number
12-Position Panel; 1 RU (1.75“ H)
12-Position Rapid Fiber Panel - SC/APC to MPO 100'
RCP-1J1DUE03100
12-Position Rapid Fiber Panel - SC/APC to MPO 200'
RCP-1J1DUE06100
12-Position Rapid Fiber Panel - SC/APC to MPO 300'
RCP-1J1DUE09200
12-Position Rapid Fiber Panel - LC/UPC to MPO 100'
RCP-1K1DUE03100
12-Position Rapid Fiber Panel - LC/UPC to MPO 200'
RCP-1K1DUE06100
12-Position Rapid Fiber Panel - LC/UPC to MPO 300'
RCP-1K1DUE09200
24-Position Panel; 1 RU (1.75“ H)
2-2
24-Position Rapid Fiber Panel - SC/APC to MPO 100'
RCP-1J2DUE03100
24-Position Rapid Fiber Panel - SC/APC to MPO 200'
RCP-1J2DUE06100
24-Position Rapid Fiber Panel - SC/APC to MPO 300'
RCP-1J2DUE09200
24-Position Rapid Fiber Panel - LC/UPC to MPO 100'
RCP-1K2DUE03100
24-Position Rapid Fiber Panel - LC/UPC to MPO 200'
RCP-1K2DUE06100
24-Position Rapid Fiber Panel - LC/UPC to MPO 300'
RCP-1K2DUE09200
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
FPX Series Rack Mount Fiber Panels
The FPX series provides industry-leading fiber cable protection
and management in a modular footprint. The panel utilizes
an internal splicing system that creates a compact, featurerich, high-density solution. FPX achieves densities of 24-fiber
terminations/splices in 1 RU (1.75") using SC connectors. These densities are attained while utilizing TE’s angled adapters to
ease cable access, protect bend radius and provide individual fiber access. Field-installable vertical cable guides on either
side of the panel allow for managed routing and protection of the fiber entering and exiting the panel.
Panels are available with preterminated pigtails, adapters only, or with MPO adapters packs. The MPO adapter packs utilize
an MPO interface, and makes it a great match with the rapid panel, or flexible fiber box.
FEATURES
• MPO adapter packs which eliminates the
need for on-site fiber terminations or splicing,
thus reducing overall deployment time
• Sold separately for maximum flexibility with
minimum lead time, FPX adapter packs
can also be pre-configured at the factory
for more efficient service turn-up
• FPX panels combine the unique features of
vertical cable guides and angle-left/angleright adapters, offering bend radius protection,
intuitive routing and easy connector access
• Adjustable mounting brackets provide either
19- or 23-inch rack or cabinet mounting (EIA or
WECO) as well as 4- or 5-inch recess mounting
• Rear access makes field termination or splicing
fast and efficient. 1 RU and 2 RU versions feature
convenient sliding access to terminations and splicing.
ORDERING INFORMATION
Product Description
Empty Chassis; 1 RU
Sliding drawer accommodates 2 adapter (1 left/1 right); putty color
Part Number
FPX-1TR000-000
MPO Adapter Pack
Left cassette loaded with 12 singlemode SC/APC front simplex adapters and rear MPO adapter
FPX-12MPLS0J
Right cassette loaded with 12 singlemode SC/APC front simplex adapters and rear MPO adapter
FPX-12MPRS0J
Left cassette loaded with 12 singlemode LC/APC front simplex adapters and rear MPO adapter
FPX-24MPLS08
Right cassette loaded with 12 singlemode LC/APC front simplex adapters and rear MPO adapter
FPX-24MPRS08
Adapter Pack with Stranded Pigtails
Left adapter pack loaded with 12 singlemode LC/UPC adapters and 3 meter singlemode stranded pigtails
FPX-24APL08SP3
Right adapter pack loaded with 12 singlemode LC/UPC adapters and 3 meter singlemode stranded pigtails
FPX-24APR08SP3
Left adapter pack loaded with 12 singlemode SC/APC simplex adapters and 3 meter singlemode stranded pigtails
FPX-12APL0JSP3
Right adapter pack loaded with 12 singlemode SC/APC simplex adapters and 3 meter singlemode stranded pigtails
FPX-12APR0JSP3
Adapter Packs
Left adapter pack loaded with 12 singlemode SC/APC simplex adapters; 12 fiber ports per adapter pack
FPX-12APL0J
Right adapter pack loaded with 12 singlemode SC/APC simplex adapters; 12 fiber ports per adapter pack
FPX-12APR0J
Left adapter pack loaded with 12 singlemode LC/UPC adapters or 24 fiber ports per adapter pack
FPX-24APL08
Right adapter pack loaded with 12 singlemode LC/UPC adapters or 24 fiber ports per adapter pack
FPX-24APR08
Blank Panel
2-3
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
FPX-N0AP00
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
LSX Optical Distribution Frame
PRETERMINATED FIBER TERMINATION/SPLICE PANELS WITH PIGTAILS
LSX preterminated fiber termination/splice panels are available with a splicing area integrated
into the panel. The 12-, 24-, and 48-position panels are 12-inches deep. The 72-, 96-, and
144-position panels are 15-inches deep. These panels include a rear flip-down splicing
compartment. The panels can be ordered with 12-fiber ribbon or 12-fiber stranded pigtails.
Termination/Splice Panels
72-Position
Termination/Splice Panel
ORDERING INFORMATION
Product Description
Rack
Units
Dimensions
(H x W x D)
Cable
Type
Splice
Type
Part Number
Panels with SC/APC Connectors
12-Port
1 RU
1.75" x 19/23" x 12"
Stranded IFC
Heat Shrink Fusion LSX-1L1012-A-SPL
24-Port
1 RU
1.75" x 19/23" x 12"
Stranded IFC
Heat Shrink Fusion LSX-1L1022-A-SPL
48-Port
2 RU
3.5" x 19/23" x 12"
Stranded IFC
Heat Shrink Fusion LSX-3L1042-A-SPL
72-Port
4 RU
7" x 19/23" x 15"
Stranded IFC
Heat Shrink Fusion LSX-6L1062-A-SPL
96-Port
4 RU
7" x 19/23" x 15"
Stranded IFC
Heat Shrink Fusion LSX-7L1092-A-SPL
144-Port
9"
9" x 19/23" x 15"
Stranded IFC
Heat Shrink Fusion LSX-TL1122-A-SPL
Panels with SC/APC Connectors
12-Port
1 RU
1.75" x 19/23" x 12"
Ribbon IFC
Mass Fusion
LSX-1L5013-A-SPL
24-Port
1 RU
1.75" x 19/23" x 12"
Ribbon IFC
Mass Fusion
LSX-1L5023-A-SPL
48-Port
2 RU
3.5" x 19/23" x 12"
Ribbon IFC
Mass Fusion
LSX-3L5043-A-SPL
72-Port
4 RU
7" x 19/23" x 15"
Ribbon IFC
Mass Fusion
LSX-6L5063-A-SPL
96-Port
4 RU
7" x 19/23" x 15"
Ribbon IFC
Mass Fusion
LSX-7L5093-A-SPL
144-Port
9"
9" x 19/23" x 15"
Ribbon IFC
Mass Fusion
LSX-TL5123-A-SPL
Note: Termination and splice panels 72 terminations and greater are 15" deep
Adapter-Only Panels
ORDERING INFORMATION
Product Description
Rack
Units
Dimensions
(H x W x D)
Part Number
Panels with SC/APC Connectors
12-Port
1 RU
1.75" x 19/23" x 12"
LSX-1L0000
24-Port
1 RU
1.75" x 19/23" x 12"
LSX-1L0000
48-Port
2 RU
3.5" x 19/23" x 12"
LSX-2L0000
72-Port
4 RU
7" x 19/23" x 12"
LSX-6L0000
96-Port
4 RU
7" x 19/23" x 12"
LSX-7L0000
144-Port
5 RU
9" x 19/23" x 12"
LSX-TL0000
Adapter-only panels between 72 and 288 terminations will not accept splice trays due to the 12" chassis depth.
For splicing in these termination counts, please refer to the LSX termination and splice panels.
Additional configurations available; please contact the TE Technical Assistance Center for details 800.366.3891 x73475.
2-4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
LSX Splice Panels
The LSX splice panel has the same mounting dimensions as LGX® compatible panels and
consists of six drawers, designation labels and a cover. Maximum splice capacity is 144 when
splicing individual stranded fibers or 432 fibers when using ribbon fiber and mass fusion
splicing. The LSX splice panel requires F3DF splice trays. Each drawer holds twenty-four 900
micron pigtails or twelve 3.0 mm pigtails. Pigtails and cable enter and exit through access
ports in the rear of the panel.
Vertical cable guides must be ordered along with the LSX splice panel unless it is mounted
into a frame that includes vertical cable guides. If needed, cable clamp kit must be ordered
separately (see page 2-6).
178 mm (7")
432 mm (17")
Splice Panel
Shown without Vertical Cable Guides
Ordered Separately(Front View)
ORDERING INFORMATION
Description
LSX splice panel; 4RU 7"h x 19"/23" x 12" rack mount
2-5
279 mm (11")
Part Number
LSX-SPLCA06
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Panels
Splice Tray
Each splice tray is purchased separately.
ORDERING INFORMATION
Description
Part Number
Splice tray; 12 splices per tray
Mass fusion ribbon
FST-F3DF-MT-D*
Heat shrink (single fiber fusion)
FST-F3DF-HS
Bare fusion
FST-F3DF-FT
Mechanical (mass fusion)
FST-F3DF-FT
Nortel QPAK
FST-F3DF-NT
*Use only one FST-F3DF-MT-D per splice drawer (24 splices per tray).
Use trays with the LSX splice panel only. Note: Trays can not be used in
preterminated LSX splice panels. Preterminated LSX splice panels already
include splice trays.
Cable Clamp Kit and Cable Ring Kit
The cable clamp kit provides a means of securing the end of an OSP or IFC
cable to the side of an LSX panel. The cable ring protects and manages jumpers
on the frame.
ORDERING INFORMATION
Description
Part Number
Cable clamp kit includes 1 dual bracket and 1 cable clamp
LSX-CBLCLMPKIT
Cable ring kit includes 2 cable rings and appropriate hardware
LSX-ACCVCGKIT
2-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Splice Tray
Fiber Wall Boxes
TE Wall Box Portfolio.................................................................................................. 3-1
Rapid FFB........................................................................................................................3-2
Pre-configured Rapid FFB..................................................................................... 3-4
Fixed FFB.........................................................................................................................3-5
FFB Plates........................................................................................................................3-7
Empty FFB......................................................................................................................3-8
FFB Accessories...........................................................................................................3-9
Mini Rapid Fiber Distribution Terminal (RDT)............................................3-10
Collector Enclosure................................................................................................... 3-13
Fiber Distribution Terminals (iFDT).................................................................. 3-16
Wall Splice Cabinet................................................................................................... 3-18
Fiber Demarcation Cabint..................................................................................... 3-19
WMG Fiber Wall Box................................................................................................ 3-21
Plug-and-Play Adapter Packs............................................................................ 3-23
Fiber Entrance Cabinet..........................................................................................3-24
Accessories
Cable Clamping Kit Splice Tray.................................................................... 3-25
Splice Tray................................................................................................................ 3-25
Grounding Kit......................................................................................................... 3-25
2-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
TE Wall Box Portfolio
TE wall boxes are designed for use in both in-building and outside plant environments.
We offer an unrivaled breadth of low to high density solutions with superior cable
management that are “Right sized” to meet space requirements for a variety of
DAS deployments.
CABLE MANAGEMENT
The management of the fiber cables has a direct impact on network reliability,
performance and cost. TE’s wall box solutions incorporate the four elements of a
successful cable management system:
• Integrated bend radius protection
• Clear, intuitive cable routing paths
• Easy connector and cable access
• Physical protection of fiber
Mini RDT
PERFORMANCE
TE’s wall box solutions are designed to perform in the most rigorous customer
applications and in a variety of fiber environments.
• Created for longevity and low life-cycle cost
• Ensure fast and easy installation
• Engineered for easy expansion and for cost effective upgrades
• Withstands harsh inside and outside environmental conditions
INNOVATION
Many TE wall box solutions incorporate the latest in cutting-edge technology,
helping to deliver unmatched savings in installation time, and labor costs and
performance in all fiber networks.
Flexible Fiber Box FFB
• Reduced bend radius fiber eliminates attenuation caused
from macro bends; and allows for tighter slack storage
spools and promotes the use of smaller enclosure
• Low-loss MPO connectors promote the use of
easier handing and routing of cables
• Plug-and-play technology reduces splice labor
requirements and speeds service turn ups
QUALITY
TE strives to exceed customer expectations and is committed to delivering the
highest quality products throughout the world. TE accomplishes this through
continual improvement in customer satisfaction, supplier relationships and our
business management system. ISO 9001 standards and statistical process controls
help to keep TE's wall box equipment within strict specifications.
3-1
Fiber Distribution Cabinet (FDC)
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Rapid FFB
The Rapid FFB utilizes the RapidReel fiber cable spool to pay-out of internal fiber cable. The innovative spooling system
eliminates the need for detailed site survey inspections. It simplifies cable ordering requirements, and speeds the installation of
DAS networks.
FEATURES:
• 12 or 24 fibers
• Removable/interchangeable RapidReel fiber cable spool
• Available with LC/UPC, SC/UPC, and SC/APC drop side connectors
• Available with adapter terminations
• Available with integrated splice tray
• Singlemode operation
• 3.6mm stranded indoor/outdoor riser rated microcable
• Internal spool holds up to 250' of 12-fiber cable, or up to 100' of 24-fiber cable
• Additional slack storage available in increments of 100’ upto 1000'
Rapid FFB to Fixed FFB with MPO Connectors
Available in two unique base configurations, Fixed and Rapid, the FFB promotes true flexibility with easily interchangeable
components for termination, sliding adapter pack, fixed bulkhead, splice, MPO and hardened multifiber optical connector
(HMFOC) configurations.
The Rapid FFB system leverages TE’s RapidReel fiber cable spool to payout fiber directly from the enclosure. By enabling
faster cable routing and installation, the fiber cable spool helps to minimize overall labor costs. In addition, the spooling system
reduces the need for site survey inspections, and simplifies cable ordering and inventory requirements. Any excess cable stores
easily back on to the spooling system, eliminating the need for additional slack storage equipment.
3-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
TYPICAL APPLICATION OF A RAPID FFB
3
1
2
4
3
4
Rapid FFB
1
3
1
2
4
3
4
2
FPX Panel
2
1
3-3
DAS Host Unit
2
DAS Expansion Group
3
1
Remote Amplifier
Unit (RAU)
4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Antenna
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Preconfigured Rapid FFB
Preconfigured Rapid FFB units are available to ship from the factory with preinstalled RapidReel fiber cable spools, sliding
adapter packs, splice trays, and/or preterminated cable assemblies, and help to simplify the ordering process and reduce
installation time and cost.
SPECIFICATIONS
Color:Almond
Material Type:
Metallic Enclosure
Enclosure Dimensions:
10.5 H x 12 W x 5 D"
Maximum Feeder or Distribution Fibers: 24 (Dependent on Cable)
Splitter Capacity:4
MPO Capacity:3
HMFOC Connectors Capacity:2
Cable Type:
3.6mm indoor/outdoor rated singlemode microcable (12 fibers per cable)
Operating Temperature:
Installation (-18°C to +50°C), Operating (-40°C to +65°C)
Enclosure Rating:
NEMA-4, UL
ORDERING INFORMATION
Product Description
Fibers
12
Rapid FFB
Sliding Adapter Pack Option
24
Connector Type
Part Number
LC-MPO
SKSSDUXXX
SC/APC-MPO
FFB-R012ESJSSDUXXX
LC-MPO
FFB-R024ESKSSDUXXX
SC/APC-MPO
FFB-R024ESJSSDUXXX
Rapid FFB – LC or SC Connectors
ORDERING INFORMATION
Product Description
Fibers
12
Rapid FFB
Splice Option
24
Connector Type
Part Number
MPO (far end)
FFB-R012ES22SDUXXX
Stub (far end)
FFB-R0120S22SDUXXX
MPO (far end)
FFB-R024ES22SDUXXX
Stub (far end)
FFB-R0240S22SDUXXX
Rapid FFB - Splice Tray
XXX=
031
061
076
092
123
153
183
213
244
274
305
3-4
100 FT Spooled (31 Meters).
200 FT Spooled (61 Meters). 24 Fiber requires ext. spool
250 FT Spooled (76 Meters). 24 Fiber requires ext. spool
300 FT Spooled (92 Meters). w/ext. spool
400 FT Spooled (122 Meters). w/ext. spool
500 FT Spooled (153 Meters). w/ext. spool
600 FT Spooled (183 Meters). w/ext. spool
700 FT Spooled (213 Meters). w/ext. spool
800 FT Spooled (244 Meters). w/ext. spool
900 FT Spooled (274 Meters). w/ext. spool
1000 FT Spooled (305 Meters) w/ext. spool
FFB with external fiber spool.
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Fixed FFB
The Fixed FFB utilizes interchangeable plates for the feeder (left) and drop (right) side of the enclosure, allowing service
providers to mix-and-match the unit with different connector types. For co-location scenarios, a locking plate is available to
protect the feeder or drop side of the box from unauthorized tampering.
FEATURES
• 12- or 24-fiber option
• Interchangeable plates for feeder and drop side connections
• Available with LC, SC/UPC or SC/APC drop side connectors
• Available with sliding adapter pack terminations
• Available with fixed adapter type, and fixed adapter type in center terminations
• Available with MPO or HMFOC feeder side connectors
• Available with internal demarc door on feeder or drop side
• Available in singlemode or multimode operation
TYPICAL APPLICATION OF A FIXED FFB
3
1
1
4
2
Fixed FFB
3
4
3
2
1 RU Rapid Fiber Panel
1
4
2
3
4
1
3
3-5
DAS Host Unit
Remote Amplifier
Unit (RAU)
2
4
DAS Expansion Group
Antenna
2
1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Preconfigured Fixed FFB
Pre-configured Fixed FFB units are available to ship from the factory with pre-installed connectors, adapter packs, splice trays,
cables and/or pre-terminated pigtail assemblies, and help to simplify the ordering process and reduce installation time and
cost.
ORDERING INFORMATION
Product Description
Fibers
12
Feeder:MPO
Drop: Sliding Adapter Type
24
Feeder: HMFOC
Drop: Sliding Adapter Type
Feeder:Splice
Drop: VAM
(Order VAM modules
separately)
Feeder: External HMFOC Input with
Demarc Door
(Sliding Adapter Type
Shown)
Feeder: Splice
Drop: Sliding Adapter Type
12
Connector Type
Part Number
LC
FFB-F012EMSKSSDDUx
SC
FFB-F012EMS7SSDDUx
LC
FFB-F024EMSKSSDDUx
SC
FFB-F024EMS7SSDDUx
LC
FFB-F012UMSKSSDDUx
SC
FFB-F012UMS7SSDDUx
LC
FFB-F024UMSKSSDDUx
SC
FFB-F024UMS7SSDDUx
12
–
FFB-F01222SOVS0000
24
–
FFB-F02422SOVS0000
LC
FFB-F01200HKSSDDUD
SC
FFB-F01200H7SSDDUD
24
12
24
12
24
12
Feeder/Drop: Fixed Adapter Type
in Center
24
12
Feeder:MPO
Drop: Fixed Adapter Type Plate
24
LC
FFB-F02400HKSSDDUD
SC
FFB-F02400H7SSDDUD
LC
FFB-F01222SKSSDDUx
SC
FFB-F01222S7SSDDUx
LC
FFB-F02422SKSSDDUx
SC
FFB-F02422S7SSDDUx
LC
FFB-F012KCSK0SA00x
SC
FFB-F0127CS70SA00x
LC
FFB-F024KCSK0SA00x
SC
FFB-F0247CS70SA00x
LC
FFB-F012EMSKFSDDUx
SC
FFB-F012EMS7FSDDUx
LC
FFB-F024EMSKFSDDUx
SC
FFB-F024EMS7FSDDUx
Replace x with "D" to include internal demarc door, or "0" to exclude door.
3-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
FFB Plates
FFB plates are available to ship from the factory with pre-installed connectors, adapter packs, splice trays, cables and/or
pre-terminated pigtail assemblies, and help to simplify the ordering process and reduce installation time and cost.
ORDERING INFORMATION
RAPID REEL PLATES
Product Description
Fibers
Part Number
FFB-RD0120MD2XXX
12
FFB-RD0120MD2XXX
RapidReel
Splice Option
FFB-RD0240MD2XXX
24
FFB-RD0240MD2XXX
Product Description
Connector Type
Part Number
LC/UPC
FFB-RD012KMDSXXX
SC/APC
FFB-RD012JMDSXXX
LC/UPC
FFB-RD024KMDSXXX
SC/APC
FFB-RD024JMDSXXX
12
RapidReel
Connector Option
24
XXX=
031
061
076
092
123
153
XXX=
183
213
244
274
305
100 FT Spooled (31 Meters).
200 FT Spooled (61 Meters). 24 Fiber requires ext. spool
250 FT Spooled (76 Meters). 24 Fiber requires ext. spool
300 FT Spooled (92 Meters). w/ext. spool
400 FT Spooled (122 Meters). w/ext. spool
500 FT Spooled (153 Meters). w/ext. spool
600 FT Spooled (183 Meters). w/ext. spool
700 FT Spooled (213 Meters). w/ext. spool
800 FT Spooled (244 Meters). w/ext. spool
900 FT Spooled (274 Meters). w/ext. spool
1000 FT Spooled (305 Meters). w/ext. spool
FIXED PLATES
Product Description
Cable Type
Singlemode
Fixed Adapter Type
in Center Plate
Multimode
Singlemode
Sliding Adapter Type Plate
Multimode
Singlemode
Fixed Horizontal Adapter
Type Plate
Multimode
3-7
Fibers
Connector Type
Part Number
24
LC
FFB-FD024K0AC000
12
SC/APC
FFB-FD012J0AC000
24
LC
FFB-FD024K0AC000
12
SC
FFB-FD012J0AC000
24
LC
FFB-FD024KMDS000
12
SC/APC
FFB-FD012JMDS000
24
LC
FFB-FD024CMFS000
12
SC
FFB-FD012TMFS000
24
LC
FFB-FD024KMDF000
12
SC/APC
FFB-FD012JMDF000
24
LC
FFB-FD024CMF000
12
SC
FFB-FD012TMF000
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
FFB Plates (Continued)
ORDERING INFORMATION
Product Description
Part Number
Product Description
Part Number
Internal Door for
Fixed Adapter
Bulkhead
FFB-FD000000K000
VAM Module
Mounting Plate
FFB-FD000000V000
Internal
Door-Standard
FFB-FD000000J000
HMFOC Bulkhead
Mounting Plate
FFB-FD000000U000
MPO Bulkhead
Mounting Plate
FFB-FD000000M000
Splice Tray
(Heat Shrink) Plate
FFB-FD0000002000
Strain Relief Plate
(For use with VAM
plate)
FFB-FD000000W000
*Order VAM modules separately.
Empty FFB
The FFB can be purchased empty without any connectors, cables or accessories. In this form, the user can mix-and-match any
combination of FFB plates or accessories as needed to meet their network requirements.
ORDERING INFORMATION
Product Description
Part Number
Empty box for Fixed FFB configurations.
No fiber. Includes grommets.
FFB-F0000S00S00000
Empty box for Rapid FFB configurations.
No fiber. Includes grommets.
FFB-R0000S00S00000
Single Width Plates (i.e. Splice,
Sliding Adapter Type, MPO)
(Empty box for Fixed FFB shown)
Double Width Plates (i.e. Fixed
Type, Fixed Adapter in Center,
Rapid Reel Plates)
3-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Accessories – 1 1/2" Grommet Kit
ORDERING INFORMATION
Product Description
Replacement kit for bottom drop/feeder plate and grommet assembly.
Kit Includes:
2 foam grommets
2 o-rings
2 spacers (large almond colored washers)
2 locking nuts
2 cable entry ports/fittings
1 port plate
1 port plate gasket
8 stainless steel screws (4-40)
3-9
Part Number
FFB-BTM-PLT-KIT
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) fiber connectivity solutions are designed from the ground up to
meet the unique requirements of DAS networks.
The Mini Rapid Fiber Distribution Terminal (RDT) is a compact, high-density, fiber
box solution, designed to speed installation requirement between the DAS host and
remote hubs. Utilizing the patent-pending RapidReel cable payout spool, the Mini RDT
deploys up to 100’ of plenum and 50’ of indoor/outdoor 12-fiber cable. Longer cable
lengths upto 650' are available on an external spool. The multifiber cable terminates to
either a multifiber push-on connector (MPO), or a 4, 8, or 12 fiber single breakouts with
SC/APC connectors or LC/UPC connectors.
The Mini RDT is a cost-efficient system for deploying and managing fiber fed DAS
networks within small to mid-sized indoor environments.
FEATURES
• Compact design: 7.8" x 5.5" x 2.3"
• RapidReel cable payout spool deploys up to 100' (30 m) of stubbed cable
• External spool included for plenum cable lengths over 100'
(30 m) and indoor/outdoor cable over 50' (15 m)
• Cable can be factory terminated with a low-loss MPO connector,
or individual fiber connectors
• Equipped with 4, 8 or 12 adapter ports
• Plastic construction – no grounding required
• Removable cover and adapter housing
• Screw mounts to a wall or flat surface
• Security screw holds cover in place
• Flexible cable routing: Distribution cable can exit from bottom or side of unit
BENEFITS
• High-density, flexible solution for deploying and managing fiber optic connections
• Plug-and-play system eliminates costly splicing requirements
• Innovative RapidReel cable payout spool ensures fast cable
deployment and provides storage for excess cable
• Low profile design allows unit to be installed in niche spaces—
walls, corridors, behind ducts or other existing equipment
• Reduced bend radius fiber and intuitively designed cable
paths eliminate attenuation and signal loss
• Shatter-resistant plastic enclosure minimizes corrosion, dust and moisture entry
• Hinge mechanism locks cover in open position for unhindered technician access
3-10
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
ORDERING INFORMATION
Part Number
RDT - S M __ __ __ 0 0 _ _ __ __ __ __
Enclosure Type
M
12 Fiber plastic
Cable Count
04
4
08
8
12
12
Connector Type
J
SC/APC
K
LC/UPC
L
LC/APC
N
SC/UPC
Cable Type
Stubbed End Configuration
A
MPO connector
O
No connector
Fanout
N
SC/UPC
J
SC/APC
K
LC/UPC
L
LC/APC
Enclosure End Configuration
9
900 µm - standard
Cable Length (Plenum)1
030
30 meters (100')
61 meters (200')
D
Indoor/outdoor 3.6mm black
061
P
3 mm loose tube ivory plenum
(zipcord for 24 fibers)
092
92 meters (300')
122
122 meters (400')
152
152 meters (500')
183
183 meters (600')
Cable Length (Indoor/Outdoor)1
015
External spool included for plenum cable
lengths over 100' (30 m) and indoor/
outdoor cable over 50' (15 m)
1
15 meters (50')
030
30 meters (100')
045
45 meters (150')
061
61 meters (200')
076
76 meters (250')
092
92 meters (300')
107
107 meters (350')
122
122 meters (400')
137
137 meters (450')
152
152 meters (500')
168
168 meters (550')
183
183 meters (600')
198
198 meters (650')
Single fiber breakout option
3-11
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
TYPICAL APPLICATION OF A MINI RDT IN AN INDOOR DAS INSTALLATION
4
1
3
2
4
1
Fiber Wall Box
1
2
3
4
2
1
FPX
3
2
4
1
2
1
Main Hub
2
Expansion Hub
3
2
1
5
5
3
4
3-12
Remote Access
Unit (RAU)
Antenna
5
BTS
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Collector Enclosure
TE's Rapid Collector Enclosure serves as zoned, intermediate distribution points for
designs using MPO cable stubs instead of splices. Each enclosure is wall mounted
within a building and accommodates up to six MPO pairs and ships with 72-fiber
riser ribbon stubs.
FEATURES AND BENEFITS
Rapid Collector Enclosure (open)
• Accommodates up to 6 MPO mated pairs
• Ships with 72-fiber riser ribbon stubs
• Slotted foam grommet provides easy drop installs while maintaining seal
SPECIFICATIONS
Fibers:72
Cable Ports:
1 top and bottom
Jumper Ports:
1 top and bottom
Rating:NEMA-12
Height:6.0"
Width:9.0"
Depth:2.5"
Part Number
MCA-S __ B __ 1 M __ __
Fiber Count
72 72 fiber
Cable Type
B
Riser ribbon
Enclosure Type
A
6 MPO indoor
enclosure
Stubbed End Configuration
0
Stub (no connector)
Length
A
50'
B
100'
D
300'
3-13
Enclosure End
Configuration
M
12F MPO's with
enclosure
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
TYPICAL ODAS APPLICATION OF RAPID COLLECTOR ENCLOSURE
1
Rapid Collector Enclosure
3
2
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
MODEM
STATUS POWER
ADMIN/LAN
POWER
3
3
2
2
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
MODEM
STATUS POWER
ADMIN/LAN
POWER
FPX (1RU)
3
3
2
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
MODEM
STATUS POWER
ADMIN/LAN
POWER
3
3
1 RU Rapid Fiber Panel
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
MODEM
STATUS POWER
3
2
ADMIN/LAN
POWER
3
3
PORT 1
1
3
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
PORT 7
PORT 8
MODEM
STATUS POWER
ADMIN/LAN
POWER
3
4
5
PORT 1
PORT 2
PORT 3
PORT 4
POWER
STATUS
MODEM
ADMIN/LAN
1
PORT 1
2
3-14
Main Hub
Expansion Hub
3
4
PORT 3
PORT 4
POWER
STATUS
MODEM
2
Remote
Cell Site
1
PORT 2
ADMIN/LAN
2
3
Remote Access
Unit (RAU)
Antenna
5
BTS or Repeater
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
TYPICAL LOCATIONS OF SPLICED INDOOR FIBER WALL BOXES
1
Fiber Entrance Cabinet
2
Wall Splice Cabinet
3
Fiber Distribution Terminals (iFDT)
4
4
Fiber Demarcation Cabinet
3
1
2
3-15
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Fiber Distribution Terminals (iFDT)
For splicing large fiber count indoor applications, TE's iFDT can be installed
to support either individual fusion splicing or mass fusion splicing. The units
provide sealed cable ports for cables and interconnection cables and gaskets to
protect against dust and water spray. The units can also be configured with a
standard cable grip kit to provide strain relief for incoming fiber cables. The splice
compartment provides ample space for storing loose-tube, ribbon or individual
fiber slack.
FEATURES
• 12-Packs provide for high-density terminations and conserve wall space.
• Integrated splice tray offers flexible splice management
for individual or mass splicing.
• Sealed enclosure protect fibers from dust, water
spray, insects and other contaminants.
• Dual-hinged design ensures separation of owner/client network segments.
• Designed to NEMA-12
• Front and rear layer maximizes wall space utilization
for both splicing and interconnect.
• Robust steel construction protects fibers against
damage and ensures network reliability.
• Slotted cable entrance ports allow for rapid cable
installation and pass-through capability.
• Cable management and routing limits bend radius and adds strain relief.
• 216-Tool (can wrench), key lock or padlock offers flexible security options.
3-16
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Fiber Distribution Terminals (iFDT)
Part Number
FDT- __ __ __ __ __ N X __ __ __ __ 0
Enclosure Type/Capacity
12 Fiber
Stub Length
A
iFDT-12
000
0 Feet
B
iFDT-24
24 Fiber
025
25 Feet
C
iFDT-48
48 Fiber
100
100 Feet
D
iFDT-72
72 Fiber
200
200 Feet
E
iFDT-96
96 Fiber
300
300 Feet
500
500 Feet
Connector/Adapter Style
Singlemode
J
SC/APC
N
SC/UPC
K
LC/UPC
Multimode
Cable Type
Pigtails
A
B
Bare ribbon pigtail assy
12 Fiber Soft-Walled Bundle*
9
MMSC
Stubs
6
MMLC
S
Ribbon OSP w/Conn
Splice Tray
0
No Tray
2
Heat Shrink Fusion
3
Mechanical/Ribbon
R
Ribbon IFC w/Conn
T
Loose Tube OSP w/Conn
V
Loose Tube IFC w/Conn
*900 micron fiber bundled in a soft jacket.
Fiber Count
06
6 Fiber
12
12 Fiber
24
24 Fiber
48
48 Fiber
72
72 Fiber
96
96 Fiber
3-17
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Wall Splice Cabinet
WALL SPLICE CABINET
TE's Wall Splice Cabinets (WSC) provide a versatile splicing solution when
deploying indoor or outdoor DAS fiber distribution networks. The cabinets are
available in indoor and indoor/outdoor configurations making them suitable for
splicing requirements anywhere in the DAS network. The WSC also offers slack
storage and is easily accessible with its wall-mount design.
WSC-24
open
WSC-24 FEATURES
• Rated for indoor use
• Accommodates up to (2) 12-fiber splice trays
• Built-in slack storage around splice trays
• Flexible cable entry location with its 4 cable entry port design
• Top and bottom cable entry ports allow for pass through splicing capability
• Standard 216 tool access
WSC-24
closed
• Padlock and/or key lock security option
WSC-48 FEATURES
• Rated for indoor and outdoor use
• Accommodates up to (4) 12-fiber splice trays
• Built-in slack storage around splice trays
• Standard 216 tool access
• Padlock security
• One part number can accommodate indoor or outdoor demand
WSC-48
Part Number
WSC-S __ 0 __ __ __ 1 __
Enclosure Type
Key Locks
B
Indoor WSC-24 (24-fiber)
0
None (Padlock Ready)
H
Indoor/Outdoor WSC-48 (48-fiber)
E
Front Lock 1
Splice Tray (provider side)
Fiber Count
2
Heat Shrink Fusion
12
3
Mechanical/Ribbon
24
24 Fibers. 2 Splice Trays
0
No Splice Tray
36
36 Fibers. 3 Splice Trays
48
48 Fibers. 4 Splice Trays
3-18
12 Fibers. 1 Splice Tray
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Fiber Demarcation Cabinet
NEMA FIBER DEMARCATION CABINET WITH PIGTAILS
Designed for operational efficiency and scalability, NEMA fiber demarcation
cabinets simplify network installation, maintenance and management for indoor
and outside plant DAS environments.
TE's family of NEMA fiber demarcation products provides termination and splicing
for fiber cables in environments requiring secure, low profile enclosures. Built with
traditional TE quality and durability, the products promise long service life in harsh,
outside plant environments and help ensure network reliability and flexibility.
FEATURES AND BENEFITS:
• Designed to meet NEMA 250 - Type 4 (rain tight, water tight)
• Wall mountable on outside of building or in harsh indoor environments
• Lockable, removable front door
• Compact design using familiar industry interfaces
(LGX® compatible six packs) with SC, or LC connectors
• Quick installation and cable routing; reduces cost of
installation and network maintenance time
• Multiple locking options allows control access to critical parts of the wall box
• Accommodates top or bottom cable entry
• Ideal for ribbon splicing; supports stranded splicing
• Accommodates LGX compatible value-added modules
* LGX is a registered trademark of Furukawa Electric North America, Inc.
3-19
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
NEMA Fiber Demarcation Cabinet (FDC) with Pigtails
Part Number
FDC- __ __ __ __ S X __ 0 __ 0 __ __ __ 0
Number of Doors
L
Number of 6 packs loaded
1 door (NEMA 4)
Strength Member Tie-offs
Connector/Adapter Style
1
12 fibers
2
24 fibers
4
48 fibers
0
No strength member
tie-offs included
1
1 strength member tie-off included
Compression Fittings
Connector/Adapter Style
Singlemode
J
SC/APC
N
SC/UPC
K
LC/UPC
Multimode
9
MMSC
6
MMLC
0
No compression fitting
1
1 compression fitting
2
2 compression fittings
Splice Tray/Chip Style
0
None or N/A
2
Heat shrink fusion
3
Mechanical/ribbon
Pigtail or Adapter Type
A
Adapters only
R
12 fiber ribbon
4
12-fiber maxi-strip soft-wall
bundle (stranded)
3-20
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
WMG Fiber Wall Box
The WMG fiber wall box series wall mount fiber enclosures are ideal for DAS
applications requiring a fully enclosed and lockable wall mount enclosure. The
cabinets are one or two door direct termination and splice solutions. These
enclosures are designed to support up to eight modular adapter packs. The rugged
wall mount cabinet is equipped with cable management modules and cable
routing accessories to limit bend radius and add strain relief control. In addition,
the lockable dual door design allows public and private portions of the network
to be securely separated from each other. For splicing applications, the cable
management modules are removed and replaced with splice modules and up to
four eight-inch, 12-fiber splice trays.
FEATURES
• Utilizes standard RMG series adapter packs.
• Compact design
• Wrap-around client-side door design provides maximum adapter accessibility
for client-side patching
• Multi-sized cable entry knockouts supports either 1/2-inch or 3/4-inch
cable grommets for maximum cable strain relief and protection
3-21
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
SPECIFICATIONS
Storage/operating temperature: Approximate weight (empty panel)
2 adapter model: 4 adapter model: 8 adapter model:
Dimensions
2 adapter model: 4 adapter model: 8 adapter model: Configuration options and capacity
Termination only
2 adapter model: 4 adapter model: 8 adapter model: Termination/splice
2 adapter model:
4 adapter model: 8 adapter model: -40 to 85 °C (-40 to 185 °F)
2.5 Kg (5.5 lbs)
3.7 Kg (8.25 lbs)
6.2 Kg (13.75 lbs)
22.9 cm x 30.5 cm x 8.9 cm (9" x 12" x 3.5")
30.5 cm x 38.1 cm x 8.9 cm (12" x 15" x 3.5")
35.5 cm x 43.8 cm x 17.8 cm (14" x 17.25" x 7")
24 terminations
48 terminations
96 terminations
not available
48 terminations
96 terminations
WMG Empty Wall box
The WMG empty wall box allows the user to mix and match any combination of modular adapter packs
or to utilize a “grow as you go” approach to their network.
FEATURES:
• Available in three sizes to suit a variety of applications and fiber counts
• Standard LSX/LGX adapter pack footprints are accommodated in empty wall box
ORDERING INFORMATION
Product Description
Dimensions
Part Number
Wall mount fiber enclosure, black
Empty wall box, maximum capacity 2 adapter packs
22.86 cm x 30.48 cm x 8.89 cm
(9" x 12" x 3.5")
WMG-2000-00B
Empty wall box, maximum capacity 4 adapter packs
30.48 cm x 38.1 cm x 8.89 cm
(12" x 15" x 3.5")
WMG-4000-00B
Empty wall box, maximum capacity 8 adapter packs
35.56 cm x 43.82 cm x 17.78 cm
(14" x 17.25" x 7")
WMG-8000-00B
3-22
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Plug-and-Play Adapter Packs
The plug-and-play modular adapter pack assemblies can be used in any of the WMG Series fiber enclosures in a variety
of connector styles. Its modular design is user-friendly and easy to install.
FEATURES:
• Completely interchangeable between WMG panel products
• Can be ordered with all standard types of simplex and duplex multimode and singlemode adapters
• MPO adapters make it a perfect compliment to both Rapid Fiber panels and Flexible Fiber Boxes
Polarity / Wiring Scheme
MPO – Fiber Position
LC Connector
Fiber Color
MPO-1
LC-1 & LC-14
Blue
MPO-2
LC-2 & LC-13
Orange
MPO-3
LC-3 & LC-16
Green
MPO-4
LC-4 & LC-15
Brown
MPO-5
LC-5 & LC-18
Slate
MPO-6
LC-6 & LC-17
White
MPO-7
LC-7 & LC-20
Red
MPO-8
LC-8 & LC-19
Black
MPO-9
LC-9 & LC-22
Yellow
MPO-10
LC-10 & LC-21
Violet
MPO-11
LC-11 & LC-24
Rose
MPO-12
LC-12 & LC-23
Aqua
ORDERING INFORMATION
Product Description
Part Number
Termination only rack or cabinet mount panel, black
1 RU empty panel, black; accommodates 3 MPO cassettes
RMG-1000-000B
2 RU empty panel, black; accommodates 6 MPO cassettes
RMG-2000-000B
4 RU empty panel, black; accommodates 12 MPO cassettes
RMG-4000-000B
Plug-and-Play Cassettes
62.5/125 µm multimode cassettes
12 fiber cassettes; 6 SC duplex (beige) multimode adapters, 1 MPO adapter
RMG-12MPOBC3
12 fiber cassettes; 1 quad LC (beige) multimode adapters, 1 MPO adapter
RMG-12MPOBQ3
24 fiber cassettes; 2 quad LC (beige) multimode adapters, 2 MPO adapter
RMG-24MPOBQ3
50/125 µm multimode cassettes
12 fiber cassettes; 6 SC duplex (beige) multimode adapters, 1 MPO adapter
RMG-12MPOCC3
12 fiber cassettes; 3 quad LC (beige) multimode adapters, 1 MPO adapter
RMG-12MPOCQ3
24 fiber cassettes; 6 quad LC (beige) multimode adapters, 2 MPO adapter
RMG-24MPOCQ3
50/125 µm multimode laser optimized to 300 meter cassettes
12 fiber cassettes; 6 SC duplex (aqua) multimode adapters, 1 MPO adapter
RMG-12MPODC4
12 fiber cassettes; 3 quad LC (aqua) multimode adapters, 1 MPO adapter
RMG-12MPODQ4
RMG-24MPODQ4
24 fiber cassettes; 6 quad LC (aqua) multimode adapters, 2 MPO adapter
Singlemode cassettes
12 fiber cassettes; 6 SC duplex (blue) singlemode adapters, 1 MPO adapter
RMG-12MPOSC8
12 fiber cassettes; 3 quad LC (blue) singlemode adapters, 1 MPO adapter
RMG-12MPOSQ8
24 fiber cassettes; 6 quad LC (blue) singlemode adapters, 2 MPO adapter
RMG-24MPOSQ8
3-23
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Fiber Entrance Cabinet
The fiber entrance cabinet (FEC) provides splicing, administration and storage for
outside plant (OSP) and intrafacility cables (IFC). The cabinets are designed for
deployment in a building equipment area. The FEC offers a cost-effective, spacesaving alternative to splicing on the fiber frame.
356 mm
(14") 406 mm
(16") 813 mm
(32")
356 mm
(14") 406 mm
(16") 813 mm
(32")
711 mm
(28")
495 mm
(19.5")
330 mm
(13")
330 mm
(13")
144-Position
288-Position
• Equipped with 6 drawers
• 144 stranded fiber capacity
• 432 ribbon fiber capacity
• Equipped with 12 drawers
• 288 stranded fiber capacity
• 864 ribbon fiber capacity
ORDERING INFORMATION
Cabinet Size
Stranded
Fibers
Ribbon
Fibers
Number of
Drawers included
with Cabinet
144
432
288
864
3-24
Dimensions
Part
Number
Weight
(HxWxD)
6
40 lbs
(318.18 kg)
495 mm x 813 mm x 330 mm
(19.5" x 32" x 13")
FEC-144
12
80 lbs
(36.3 kg)
711 mm x 813 mm x 330 mm
(28" x 32" x 13")
FEC-288
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Wall Boxes
Cable Clamping Kit
ORDERING INFORMATION
Description
Part Number
IFC/OSP cable clamp kit for wall mount configurations. Secure three cables to a single cable
entry point on the cabinet. Clamp kits can be separated and used as single clamps.
Cables with a maximum diameter of mm (0.4") to 30 mm (1.2")
Cables with a maximum diameter of 5 mm (0.2") to 18 mm (0.7")
OSP-CLPFEC-LG
OSP-CLPFEC
Individual IFC/OSP cable clamp for wall mount configurations. Secure one cable to a single
cable entry point on the cabinet.
Cables with a maximum diameter of 5 mm (0.2") to 18 mm (0.7")
IFC/OSP Cable Clamp Kit
OSP-CLPSST
(OSP-CLPFEC-LG Shown)
Individual IFC/OSP cable clamp for rack or wall mount configurations. Secure one cable to a
single cable entry point on the cabinet.
Cables with a maximum diameter of 10 mm (0.4") to 30 mm (1.2")
FEC-ACCCLMP01
Individual soft IFC only cable clamp for wall mount configurations.
Secure one cable to a single cable entry point on the cabinet.
Cables with a maximum diameter of 20 mm (0.8") to 28 mm (1.1")
OSP-CLPSST-IFCL
Individual IFC/OSP Cable Clamp
Cables with a maximum diameter of 5 mm (0.2") to 18 mm (0.7")
OSP-CLPSST-IFCS
(OSP-CLPSST Shown)
Splice Tray
Standard-style FEC cabinets will accept two single trays or one dual tray per drawer. 24 stranded fibers maximum per drawer,
72 ribbon fibers maximum per drawer.
ORDERING INFORMATION
Description
Standard Splice Trays
Part Number
Single Tray (12-position)
9 mm x 299 mm x 127 mm
(0.3" x 11.75" x 5")
Dual Tray (24-position)
14 mm x 299 mm x 127 mm
(0.5" x 11.75" x 5")
Splice Sleeve
Protector
N/A
FST-D-MT
FST-ACC006
FST-HS
FST-D-HS
FST-ACC001
Mass fusion ribbon
Heat shrink (single fiber fusion)
Bare fiber
FST-FT
FST-D-FT
FST-ACC001
Mechanical
FST-FT
FST-D-MT
FST-ACC006
Grounding Kit
Set Screws
Cable Assembly Lug
10-24 Screw
Kit used to ground armored fiber cable.
ORDERING INFORMATION
Description
Part Number
Grounding Kit
(GAK-FEC001 Shown)
Grounding kit for
Armored OSP cable Includes: One cable assembly lug type ground kit,
One #6 ground cable 229 mm (9") long
GAK-FEC001
Any armored loose tube or buffer tubed fiber OSP cable Includes:
One bullet ground connector, One #6 ground cable 127 mm (5") long
GND-STPKIT
rame mount configuration
F
Any armored loose tube or buffer tubed OSP cable Includes:
One bullet ground connector, One #6 ground cable 305 mm (12") long
FEC-ACCGND0
2 Securing Nuts
Top
Base
Bullet Ground
Connector
#6 Ground Cable
Grounding Kit
(GND-STPKIT Shown)
3-25
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
FIBER OPTIC SPLICE CLOSURES
Fiber Optic Splice Closures - FOSC 450.........................................................4-1
Cable Termination Accessories........................................................................... 4-4
Closure Sealing Accessories................................................................................. 4-4
SMOUV splice protection sleeves...................................................................... 4-5
Fiber Management and Routing Accessories............................................. 4-5
Slack Basket Accessories....................................................................................... 4-5
Grounding Accessories............................................................................................ 4-5
Gator Splice Closure.................................................................................................. 4-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
FOSC 450
GEL-SEALED FIBER OPTIC SPLICE CLOSURES
FOSC 450 fiber optic splice closures are a family of single-ended closures designed
for use most anywhere there are fiber splicing and storage needs. These closures
are available in five sizes, each featuring:
FEATURES
• Re-usable compressed gel cable sealing components
that accommodate a wide range of cable sizes
• Capability to accommodate a variety of cable styles including loose
tube or central core tube cables with single or ribbon fibers
• H
inging splicing trays that provide controlled
access to splices and slack storage
• S
plice and storage compartments accessible via
a removable dome-clamp system
• T
hermoplastic outer materials that withstand
temperature and contaminate extremes
• S
lack storage baskets of various sizes that provide
different slack storage scenarios
• Many shared components between closure sizes
• A range of accessories for a variety of outside plant needs
4-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
Typical Closure Kit Contents
KIT INCLUDES:
• Dome
• Clamp
• O-ring
• Base
• Gel sealing block with
compression trigger
• Plugs for unused cable ports
• Tray tower to hold hinging
FOSC splice trays
• FOSC splice trays
(quantity according to the
ordering description)
• Cable retention hardware
(quantity according to the
ordering description)
• Miscellaneous hardware, including
fiber routing (transportation)
tubing, cable retention clamps,
strength member retainers, etc.
• Installation Instructions
DOME
The dome is made from a polymer, with ribbing added for extra strength. Five
different sizes are available (A, BS, B6, C6, D6), matching the five closure sizes in
the family.
BASE
The base houses the gel block cable sealing system and is the foundation for the
tray tower and cable attachment/retention hardware.
GEL BLOCK WITH TRIGGER
The gel block provides the sealing mechanism for cables entering the closure.
Available with six cables entry ports (450 B, BS, C or D) or four (450 A size only).
(Not Sold Separately)
DOME TO BASE SEAL
Domes are attached to the base by means of a clamp. Dome-to-base sealing is
accomplished via a compressed O-ring.
CABLE RETENTION HARDWARE
Cable strain relief and strength member termination hardware.
4-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
Closure Dimensions
L
DRAWING KEY
2
D
1. Dome
2. Clamp
3. Base
4. Trigger
1
4
3
GEL-BLOCK PROFILES
CLOSURE SIZE (DIMENSIONS IN INCHES)
L
D
A
BS
B6
C6
D6
Total closure length, excluding trigger
19
19
24
23
30
Closure outer diameter, including clamp
8
9.2
9.8
11.5
11.5
NOTE: Diameters excluding clamp are approximately 2 inches less.
Cable port dimensions (Dimensions in inches)
Number round cable ports
Cable diameter range
450 A
450 BS, B6, C6, D6
4
6
6
6
6
.30-.87
(2x)
.39-1.10
(2X)
.35-1
.35-1
.35-1
.35-1
FOSC 450 Closure Family Assembly Drawings
Note: The drawings are not to scale
450 A
450 BS (B SHORT)
Shown with 2 standard splice trays and tall version
slack basket
Shown with 6 standard splice trays and standard version
slack basket
450 B6
450 C/D
Shown with 6 standard splice trays and standard version
slack basket
D size shown with 6 standard splice trays and standard version
slack basket
Note: FOSC 450 C closure is not shown, but will replicate the D size with
the exception of shorter trays, basket, and dome.
4-3
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
Ordering FOSC 450 Fiber Optic Splice Closures
Follow the steps to choose the desired closure. Then simply match the step to the description key.
See Quick Reference Guide in the back of this catalog for additional details
FEATURES
• Closure Size: A4, BS (B Short), B6, C6, or D6
• Termination Hardware Quantity for the Kit: 2, 4, or 6
• Capacity and Type of Splice Tray
• Quantity of Splice Trays Factory Installed (Choose either “0” trays (no trays installed) or
“1” tray installed. Additional trays sold separately.)
• Slack Basket Type
• Feed-through Ground Quantity
• Flash Test Valve is Desired (Valved version is standard.)
Part Number
FOSC 450 - XX - X - XX - X - XXX
Closure Size (inches)
A4
4 cable entry ports; 8 dia. x 19 long
BS
6 cable entry ports; 9 dia. x 19.5 long
B6
6 cable entry ports; 10 dia. x 24 long
C6
6 cable entry ports; 11.5 dia. x 23 long
D6
6 cable entry ports; 11.5 dia. x 30 long
Termination Hardware Quantity for the kit
2
2 cable attachments included
4
4 cable attachments included
6
6 cable attachments included
Valve for Flash Testing
V
Valve (standard)
N
No Valve
Number of Ground Feed-through Lugs
0
No grounding
1
1 ground feed-through lug (A4 only,
N/A for BS)
3
3 ground feed-through lugs (B6, C6,
and D6 closures only, N/A for BS)
6
6 ground feed-through lugs (C6 and
D6 closure only, N/A for BS)
Capacity and Type of Splice Tray
NT
No tray installed in factory
12
A, B, or C tray with two SM6 splice modules
24*
A, B, or C tray with two SM12 splice modules
36
D tray with six SM6 splice modules
Note: FEG and MEG kits provide optional ground
isolation for FOSC 450 closures.
Slack Basket Type
N
No Basket
72*
D tray with six SM12 splice modules
A
A4 Standard Size
R1
A, B size ribbon tray (accommodates
12 ribbons/144 fibers)
B
B6, BS Standard Size
C
C6 Standard Size
R2
D size ribbon tray(24 ribbons/288 fibers)
D
D6 Standard Size
R3
C size ribbon tray(18 ribbons/216 fibers)
SF
Stackable single fusion trays (12 splices)
E
Special Bulkhead Basket arrangement
for B, BS closures only
T
Tall Size
S
Stackable Trays in D Closure
*Note: SMOUV (1120-01-US) splice protection sleeves are
highly recommended for use with SM12 splice modules.
Quantity of Splice Trays Factory Installed
0 or 1 is standard
(Choose either “0” trays (no trays installed) or “1”
tray installed. Additional trays sold separately.)
4-4
Note: D-size closures with “N” option include
backbone used to route ribbons to ribbon trays.
A and B-size closures include storage “sock.”
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
B version shown
Closure
Size
Part
Number
Description
450 BS, B, C, D
Cable Retention Plate
450 A Cable Retention
Plate
Cable Termination Accessories
Cables
Grounding
Hardware
Kits Contents
Kits/
Pkg
A Only
D20592-000
FOSC-ACC-450-A-CBLTERM
1 Port
No
Cable retention hardware; strength member retention hardware
5
A Only
C67369-000
FOSC-ACC-450-A-CBLTERM-G
1 Port
Yes
Cable retention hardware; strength member retention hardware
5
1
BS Only
D25359-000
FOSC450-CABLE-TERM-4-BS
4 Ports
No
4 sets each: cable retention hardware (with hose
clamps), strength member retention hardware
B, C, D
F67166-000
FOSC450-CABLE-TERM-2-N
2 Ports
No
2 sets each: cable retention hardware (with hose
clamps), strength member retention hardware
1
B, C, D
C61629-000
FOSC450-CABLE-TERM-2-G
2 Ports
Yes
2 sets each: cable retention hardware (with hose clamps),
strength member retention hardware; ground wires
1
B, C, D
558850-000
FOSC450-CABLE-TERM-4-N
4 Ports
No
4 sets each: cable retention hardware (with hose
clamps), strength member retention hardware
1
B, C, D
659136-000
FOSC450-CABLE-TERM-4-G
4 Ports
Yes
4 sets each: cable retention hardware (with hose clamps),
strength member retention hardware, ground wire
1
Closure Sealing Accessories
Closure
Size
Cables
Sealed1
Key Sealing
Components
Part Number
Description
Kits/
Pkg
Multiple Cables/Drop Cables per Port Seals
All
All
All
3
4
4
Quick Install
Gel Plug
Gel Tape Wrap
Quick Install
Gel Plug
A38215-000
FAK-MULDRP-45-3-DRP
10
40606V-000
FAK-MULDRP-45-3/CBL-ATT*
10
41606V-000
FAK-MULDRP-45-4-DRP
10
E21473-000
FAK-MULDRP-45-4/CBL-ATT*
10
XJ261N-000
FAK-MULDRP-45-4P-DRP
10
1F6818-000
FAK-MULDRP-45-4P/CBL-ATT*
10
FOSC-ACC-450-PORT-PLUGS
50
3-Cable Seal with Cable
Attachment Kit (assembled)
Port Plugs (used to plug empty cable ports)
All
N/A
Port Plug
A05721-000
Replacement O-Rings (fits between done and base)
450A
N/A
O-Ring
381107-000
FOSC-ACC-400AB-450A-ORIN
5
450BS
N/A
O-Ring
HG302N-000
FOSC-ACC-450-BS-ORING
5
450B
N/A
O-Ring
A51343-000
FOSC-ACC-450-B-ORING
5
450C
N/A
O-Ring
429631-000
FOSC-ACC-D-O-RING-SEAL
5
450D
N/A
O-Ring
429631-000
FOSC-ACC-D-O-RING-SEAL
5
Combined cable diameters must be within cable port size requirements.
*Cable Attachments Included
1
4-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
4-Cable Seal with Cable
Attachment Kit
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
SMOUV splice protection sleeves
Fiber Type
Part Number
Description
Sleeve Information
Kits/Pkg
SMOUV Fusion Splice Protection Sleeves
Single Fiber
693979-000
SMOUV-1120-01-US
Heat-shrinkable, 60mm, single
fiber splice protection sleeve
100
Single Fiber
143339-000
SMOUV-1120-02-US
Heat-shrinkable, 45mm, single
fiber splice protection sleeve
100
Ribbon Fiber
888498-000
SMOUV-1120-R2/12-US
Heat-shrinkable, 42mm, 12 fiber
ribbon splice protection sleeve
50
Fiber Management and Routing Accessories
• Single and Ribbon fiber
Closure
Sizes
Tubing Style
Part Number
Description
Kit Includes
Std.
Pack
All
Transportation
526767-000
FOSC-ACC-TTUBE-SMLL-16IN
Six 16 inch pieces
240
All
Transportation
829333-000
FOSC-ACC-TTUBE-SMLL-50FT
One 50 foot section
All
Transportation
118317-000
FOSC-ACC-TTUBE-LRGE-16IN
Six 16 inch pieces
All
Transportation
646311-000
FOSC-ACC-TTUBE-LRGE-50FT
One 50 foot section
All
Transportation
577809-000
FOSC-ACC-TTUBE-RBN12-16I
Six 16 inch pieces
All
Transportation
226809-000
FOSC-ACC-TTUBE-RBN12-50
One 50 foot section
All
Transportation
F2103R-000
FOSC-ACC-TTUBE-RBN-16I
Six 16 inch pieces
All
Transportation
57581K-000
FOSC-ACC-TTUBE-RIBN24-50
One 50 foot section
All
Buffer Tube
Wrap
RH0073-000
FOSC-ACC-LBTWRAP-100
One wrap
All
Spiral
234855-000
FOSC-ACC-SPRLTUBE-1/8
One 500 foot roll
1
All
Spiral
469031-000
FOSC-ACC-SPRLTUBE-3/16
One 200 foot roll
1
All
Spiral
RH0090-000
FOSC-ACC-SPRLTBE-3/16-25
One 25 foot section
1
All
Spiral
460490-000
FOSC-ACC-SPRLTBE-3/8-50
One 50 foot section
1
4-6
10
240
10
240
10
240
10
100
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
Slack Basket Accessories
FEATURES
• Various styles for regular or increased slack storage
• Slack Baskets-for converting no-basket kits to basket versions, or
for changing basket size
Sizes
Basket Style
Part Number
Description
Pkg.
A
Standard
Tall
E14672-000
A91433-000
FOSC-ACC-A8/450A-BASKET
FOSC-ACC-450A4-BASKET-T
1
BS
Standard
Tall
457507-000
F53958-000
FOSC-ACC-B-BASKET
FOSC-ACC-B-BASKET-TALL
1
B
Standard
Tall
457507-000
F53958-000
FOSC-ACC-B-BASKET
FOSC-ACC-B-BASKET-TALL
1
C
Standard
Tall
RH0199-000
RH0200-000
FOSC-ACC-C-BASKET
FOSC-ACC-C-BASKET-TALL
1
D
Standard
Tall
089279-000
056395-000
FOSC-ACC-D-BASKET
FOSC-ACC-D-BASKET-TALL
1
Note: Tall style slack storage baskets provide increased slack storage over standard baskets,
but may reduce the closure's splice tray capacity!
Grounding Accessories
Part Number
Description
Kit Includes
A33560-000
FOSC-ACC-450-FIBRGRD-KIT
Groundwire and associated hardware to add
1 ground to any FOSC 450 closure
5
449105-000
FOSC-ACC-MULT-EXT-GRND-3
Groundwire and associated hardware to add up
to 3 grounds to any FOSC 450 closure*
5
671575-000
FOSC-ACC-MULT-EXT-GRND-6
Groundwire and associated hardware to add
6 grounds to any FOSC 450 closure*
5
A11796-000
FOSC-ACC-450-COM-GRD-A
Groundwires (alligator clip one end, eyelet on other)
and bonding braid to bond up to 6 cables together
5
D46439-000
FOSC-ACC-450-COM-GRD-B
Groundwires (eyelets on each end ...for use with B-Bonds)
and bonding braid to bond up to 6 cables together
5
92733M-000
FOSC-ACC-RUS-B-BONDS
RUS-listed B Bonds
*Grounds are placed though one of the cable ports.
4-7
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Kits/Pkg.
100
Connectivity Solutions for Distributed Antenna Systems
Fiber Optic Splice Closures
Gator Splice Closure
The Gator splice closure is a small butt splice closure primarily designed
for splicing two loose tube “flat drop” style cables of 1 to 12 fibers in
above grade, below grade, and direct buried applications. This splice
closure uses TE Connectivity’s well accepted gel sealing technology to
create a sealed closure system that will fit into confined areas such as
small “flowerpot” style handholes. The Gator splice closure incorporates
our unique cable hold down and strength member termination features
and is capable of holding either fusion or mechanical splices. Simple
closing of the lid and base creates a sealed closure system. No separate
grommets, mixing of chemicals or tools are required. Tone wires can also be terminated outside of the closure using the
included hardware.
FEATURES AND BENEFITS
• Compatible with most flat drop cable type
• Accommodates up to 12 single fibers, 12 ribbonized fibers, or one 12 fiber ribbon
• Gel sealing
• Toning wire hardware included
• Small size: 7.5" x 5.8" x 1.2" thick
• Two mounting tabs are integrated into the closure base to allow easy mounting
• Re-enterable but not re-usable
Descripton
Gator 12F splice Closure
Package
Part Number
10/pk
MR3919-000
Item Description
Package
Part Number
Item Description
100/pk
88823Y-00
FDSC-GATOR-TEL-SPLICE
FDSC-GATOR-12-T
Product Dimensions
7.5" x 5.8" x 1.2"
ACCESSORIES
Descripton
Tone Wire Connector
Fiber Type
Splice Proctection Sleeves
62 mm length
100/pk
693979-000
SMOUV-1120-01-US
45 mm lenght
100/pk
143339-000
SMOUV-1120-02-US
Single
47 mm lenght
50/pk
888498-000
SMOUV-1120-R2/12-US
Ribbon
4-8
Single
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
FIBER CABLE PRODUCTS
Fiber Patch Cords......................................................................................................... 5-1
Multi-Fiber Patch Cords...........................................................................................5-3
IFC Cables w/ MPOptimate....................................................................................5-5
12-Fiber Plug-and-Play Array Cables................................................................5-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Patch Cords
SINGLEMODE PATCH CORDS (SIMPLEX AND DUPLEX)
All patch cords undergo stringent testing for both insertion loss and return
loss at the factory before shipment to ensure that only quality product is
delivered to the customer.
SC ultra polish
SC angled polish
FC ultra polish
TE offers ultra physical contact (UPC) polish on the SC, FC, and
LC connector styles.
LC angled polish
Angled polish is available on the LC connector and the SC connector styles.
Angled polish should be used in applications that require better control of
return loss. TE has tight tolerances regarding the rotation of the ferrule to
maintain low insertion loss values.
LC ultra polish
Connector Types
Part Number
__ __ - __ - __ - __ M
Cable Option
FPC
FPT
Connector on both ends
(patch cord)
Connector on one end
(pigtail)
Cable Type
Standard singlemode
Assembly Length
1-20
1-20 meters in 1 meter increments
25-65
25-65 meters in 5 meter increments
70-150
70-150 meters in 10 meter increments
Fiber Type
S
Standard singlemode
P
Reduced bend radius singlemode (blue)*
M
2.0 mm single
F
1.7 mm single
9
900 µm
2
2.0 mm dual zip
SPSC
SC ultra polish simplex
T
1.7 mm dual zip
APSC
SC angled polish simplex
SDSC
SC ultra polish duplex2
Reduced bend radius
2.0 mm standard singlemode
LEAVE
BLANK
Singlemode Connector Type1
MW
2.0 mm single
SPFC
FC ultra polish simplex
FW
1.7 mm single
SPLC
LC ultra polish simplex
9W
900 µm
SDLC
LC ultra polish duplex2
2W
2.0 mm dual zip
APLC
LC angled polish simplex
TW
1.7 mm dual zip
ORDERING EXAMPLES
FPC2-SPSC-10M: Singlemode 2.0 mm dual zip patch cord with SC ultra polish connectors on both ends,
10 meters in length with standard breakout length of 0.31 m (12") on both ends.
For hybrid patch cords, enter both connector types in this field and separate them with a slash
mark; remove 's' from the ultra polish option.
1
FPCF-SPSC/PLC-S-10M: Singlemode 1.7 mm simplex patch cord with SC ultra polish connector on one end and LC ultra polish connector on the other end, 10 meters in length.
2
One connector per end; requires dual zip cable
* Not a substitute for well-engineered cable management.
Other connector styles are available upon request. Please contact TE Technical Assistance Center.
5-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Patch Cords
MULTIMODE PATCH CORDS (SIMPLEX AND DUPLEX)
Multimode patch cords are available with the LC small-form-factor connector and
the SC connector.
These patch cords are assembled using the same advanced manufacturing processes
as the singlemode, ensuring the highest quality standards.
LC-SC Multimode Patch Cord
Part Number
__ __ - __ - __ - __ M
Cable Option
FPC
FPT
Connector on both ends
(patch cord)
Connector on one end
(pigtail)
Cable Type
Standard multimode
M
2.0 mm single
F
1.7 mm single
9
900 µm
2
2.0 mm dual zip
T
1.7 mm dual zip
Multimode 50/125 µm 10G
Assembly Length
1-20
1-20 meters in 1 meter increments
25-65
25-65 meters in 5 meter increments
70-150
70-150 meters in 10 meter increments
Fiber Type
A
50/125 µm multimode
B
62.5/125 µm multimode
Multimode Connector Type1
MSC
SC simplex
MDSC
SC duplex2
MLC
LC simplex
MDLC
LC duplex2
laser optimized to 300 m (aqua)
MA
2.0 mm single
FA
1.7 mm single
2A
2.0 mm dual zip
TA
1.7 mm dual zip
Ordering Examples
FPCM-MSC-B-7M: Multimode simplex 2.0 mm patch cord with SC connectors on both ends, 62.5/125 µm fiber type, 7 meters in length.
1
For hybrid patch cords, enter both connector types in this field and separate them with a slash mark.
FPCM-MSC/MLC-A-3M: Multimode simplex 2.0 mm patch cord with SC connector on one end and LC connector on the other end, 50/125 µm fiber type, 3 meters in length.
2
One connector per end; requires dual zip cable
Other connector styles are available upon request. Please contact TE Technical Assistance Center.
5-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Multi-Fiber Patch Cords
Cable Jacket,
PVC 0.89 mm thick
SINGLEMODE MULTIFIBER PATCH CORDS (4- TO 24-FIBERS)
Central
Strength
Member
Aramid Yarn
Singlemode multifiber patch cords are available with 4, 6, 12 or 24 tight buffered
1.7 mm fibers enclosed in a standard wall outer jacket. Each 1.7 mm fiber is coded
for easy identification of individual fibers. Central strength member, and aramid
yarn; PVC jacket thickness 0.89 mm.
1.7 mm
Fiber
subunit
Ripcord
Ripcord
Patch cords are also available with 6, 8 or 12 tight buffered 900 µm fibers with a
thin softwall outer jacket. No central strength member or aramid yarn; PVC jacket
thickness 0.64 mm.
Standard Wall
(4-Fiber Shown)
PVC Jacket
0.64 mm thick
Soft Wall
(12-Fiber Shown)
Part Number
FPM-0 __ / __ - __ __ __ __ M- __ __ / __ __
Connector Type
(1st and 2nd end)
0
Stub (only on 2nd end)
7
SC ultra polish
E
SC angled polish
2
FC ultra polish
K
LC ultra polish
M
LC angled polish
Breakout Length
X
LEAVE
BLANK
Length in inches
Both ends 0.31 m (12")
Assembly Length
001-020
1-20 meters in 1 meter increments
025-065
25-65 meters in 5 meter increments
070-150
70-150 meters in 10 meter increments
Cable Type
D
4-fiber standard wall with 1.7 mm subunits
R
4-fiber reduced bend radius with 1.7 mm subunits (blue)
E
6-fiber standard wall with 1.7 mm subunits
P
6-fiber soft wall with 900 µm buffered fiber
AH
L
8-fiber standard wall with 1.7 mm subunits
8-fiber soft wall with 900 µm buffered fiber
N
8-fiber reduced bend radius with 1.7 mm subunits (blue)
F
12-fiber standard wall with 1.7 mm subunits
M
12-fiber soft wall with 900 µm buffered fiber
FP
12-fiber reduced bend radius with 1.7 mm subunits (blue)
AD
24-fiber standard wall with 1.7 mm subunits
GP
24-fiber reduced bend radius with 1.7 mm subunits (blue)
ORDERING EXAMPLE
FPM-07/0-P005M: Singlemode multifiber patch cord with SC ultra polish connectors on one end, no connectors on the other end (pigtail),
6-fiber soft wall, 5 meters long with standard breakout.
Other connector styles and breakout lengths are available upon request. Please contact TE Technical Assistance Center.
5-3
Buffered Fiber
900 µm
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Multi-Fiber Patch Cords
PVC Jacket
0.64 mm thick
MULTIMODE MULTIFIBER PATCH CORDS (6- AND 12-FIBERS)
Buffered Fiber
900 µm
Multimode multifiber patch cords are available with 6 and 12 tight buffered 900
µm fibers with a soft wall outer jacket. No central strength member or aramid yarn;
PVC jacket thickness 0.64 mm.
Soft Wall
(12-Fiber Shown)
Part Number
MFPM- __ / __ - __ __ __ __ M- __ __ / __ __
Connector Type
(1st and 2nd end)
0
Stub (only on 2nd end)
9
SC
P
LC
Breakout Length
X
Length in inches
LEAVE
BLANK
Both ends 0.31 m (12")
Assembly Length
001-020
1-20 meters in 1 meter increments
6-fiber soft wall, 62.5/125 µm
025-065
25-65 meters in 5 meter increments
NB
12-fiber soft wall, 62.5/125 µm
070-150
70-150 meters in 10 meter increments
WC
6-fiber soft wall, 50/125 µm
NA
12-fiber soft wall, 50/125 µm
NH
6-fiber soft wall, 50/125 µm laser
optimized to 300 m (aqua)
NG
12-fiber soft wall, 50/125 µm laser
optimized to 300 m (aqua)
Cable Type
PB
ORDERING EXAMPLE
MFPM-9/P-PB008M: Multimode multifiber patch cord with SC connectors on one end and LC ultra polish connectors on the other end, 6-fiber
soft wall cable, 8 meters in length with standard breakout.
Other connector styles and breakout lengths are available upon request. Please contact TE Technical Assistance Center.
5-4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Intrafacility Fiber Cable (IFC) Assemblies
STRANDED IFC ASSEMBLIES
Intrafacility fiber cable (IFC) is a multifiber cable designed for use within a building.
Generally, it will be constructed without metallic strength members and is designed
to meet the fire resistant characteristics required in the central office. The number
of fibers range from 12 to 144. Standard IFC assemblies are riser rated and meet
UL-1666 OFNR. Two types of IFC are available: stranded
and ribbon.
With stranded cable, individual 900 µm fibers make up the construction of the
cable. The fibers are bundled into subunits of 6- or 12-fibers each. Each subunit is
identified and the individual fibers within the subunits are color-coded. Stranded
IFC diameters increase in proportion with the fiber counts.
IFC Assembly
Detail A
Ripcord (2)
PVC Jacket
PVC Cable
Jacket
6-Fiber Subunit
(See Detail A)
Buffered
Fiber
Mylar Tape
Central Strength
Members
See
Detail C
Aramid Yarn
24-Fibers with 6-Fiber Subunits
12-Fiber Subunit
(See Detail B)
Mylar
Tape
Detail B
PVC Jacket
Aramid
Yarn
PVC Cable
Jacket
See
Detail C
Ripcord (2)
Central
Strength
Members
Buffered
Fiber
72-Fibers with 12-Fiber Subunits
PVC Jacket
Detail C
Buffered Fiber
Buffer
Coating
Buffered Fiber
900 µm
Cladding
Aramid Yarn
Core
12-Fibers Shown
5-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Intrafacility Fiber Cable (IFC) Assemblies
SINGLEMODE IFC ASSEMBLIES
Part Number
IFC - __ /__ __ __ __ __ - __
Connector Type
(1st and 2nd end)
Breakout/Panel Type1
0
Stub (only on 2nd end)
7
SC ultra polish
2
FC ultra polish
E
SC angled polish
LEAVE
BLANK
8" FCM
2A
FL2, 12 exit up or down
2B
FL2, 24 exit up or down
2C
FL2, 48 exit up or down
2D
FL2, 72 exit up
2E
FL2, 96 exit up
2F
FL2, 72 exit down
2G
FL2, 96 exit down
Cable Type
NG
NGF, 96- and 144-position
A
LA
LSX, 72- and 96-position
K
LC ultra polish
M
LC angled polish
12-fiber stranded
B
24-fiber stranded
2
48-fiber stranded
V
72-fiber stranded
L
96-fiber stranded
EH
144-fiber stranded
016
NA
12-fiber ribbon
023
23 m (75')
HA
24-fiber ribbon
031
31 m (100')
JA
48-fiber ribbon
046
46 m (150')
DS
72-fiber ribbon
061
61 m (200')
LA
96-fiber ribbon
077
77 m (250')
LH
144-fiber ribbon
092
92 m (300')
122
122 m (400')
153
153 m (500')
1
or competitors’ panel products, TE recommends using the FCM
F
breakout length (1.8 m = 6').
2
Standard lengths for connectors on both ends up to 150 meters.
Assembly Length for
Connector to Stub
Assembly Length for
Connectors on Both Ends2
For information on TE's FL2000 (FL2) FCM or LSX panel products
and Next Generation Frame (NGF) Fiber Termination Blocks, call TE
Technical Assistance Center.
XXX
Additional fiber counts, lengths and connector styles are available
upon request. Please contact TE Technical Assistance Center.
Length in meters
Example: 010 = 10 meters
Clamp Position
Breakout Length
16 m (50')
Assembly Length
125 = 125 meters
Clamp Position
Breakout Length
Fanout Length
Connector
5-6
Fanout Length
IFC Cable
Cable Clamp
Multifiber Subunits
Subunit DesignationLabel
Labels
Cable Clamp
Multifiber Subunits
Subunit Designation Label
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connector
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
Intrafacility Fiber Cable (IFC) Assemblies
MULTIMODE IFC ASSEMBLIES
Part Number
MIFC - __ / __ __ __ __ __ __ - __
Connector #1 Type
9
P
Breakout/Panel Type1
SC
LEAVE
BLANK
LC
Connector #2 Type
0
Stub
9
SC
P
LC
8 FCM
2A
FL2, 12 exit up or down
2B
FL2, 24 exit up or down
2C
FL2, 48 exit up or down
2D
FL2, 72 exit up
2E
FL2, 96 exit up
2F
FL2, 72 exit down
2G
FL2, 96 exit down
NG
NGF, 96- and 144-position
Cable Type
AB
12-fiber stranded 62.5 µm
BB
24-fiber stranded 62.5 µm
VB
72-fiber stranded 62.5 µm
016
LB
96-fiber stranded 62.5 µm
023
23 m (75')
FT
144-fiber stranded 62.5 µm
031
31 m (100')
AC
12-fiber stranded 50/125 µm
046
46 m (150')
AD
24-fiber stranded 50/125 µm
061
61 m (200')
VA
72-fiber stranded 50/125 µm
077
77 m (250')
VZ
144-fiber stranded 50/125 µm
092
92 m (300')
VE
72-fiber stranded plenum laser optimized
to 300 m, 50/125 µm (aqua)
122
122 m (400')
153
153 m (500')
FZ
144-fiber stranded plenum laser
optimized to 300 m, 50/125 µm (aqua)
Assembly Length for
Connector to Stub
16 m (50')
Assembly Length for
Connectors on Both Ends2
1
or competitors’ panel products, TE recommends using the FCM breakout
F
length (1.8 m = 6').
2
Standard lengths for connectors on both ends up to 150 meters.
XXX
Length in meters
Example: 010 = 10 meters
For information on TE's FL2000 (FL2) panel products and Next Generation
Frame (NGF) Fiber Termination Blocks, call TE Technical Assistance Center.
125 = 125 meters
Additional fiber counts, lengths and connector styles are available upon
request. Please contact TE Technical Assistance Center.
Clamp Position
Breakout Length
Assembly Length
Clamp Position
Breakout Length
Fanout Length
Connector
5-7
Fanout Length
IFC Cable
Cable Clamp
Multifiber Subunits
Subunit DesignationLabel
Labels
Cable Clamp
Multifiber Subunits
Subunit Designation Label
Connector
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
12-Fiber Plug-and-Play Array Cables
12-Fiber Plug-and-Play Array Cables provide a convenient and efficient method
to connect active equipment into the network. These 12-fiber round 3 mm cables
contain a pre-terminated high density MPO pinned connector on one end and
either LC or SC connectors on the other. The 12-Fiber Plug-and-Play Array Cable
assemblies can simply be plugged into any fiber enclosure or cable that requires an
MPO breakout.
FEATURES:
• Round design with outer diameter of 3 mm eliminates preferential bend
issues which results in increased density and greater manageability
• Each LC or SC leg clearly labeled and identified
• Standard breakout length 18-inches, which is
optimum to connect to active equipment
SPECIFICATIONS
Module Loss
(measured through MPO mated pair to LC adapter)
850 nm
Insertion Loss
Maximum:
0.70 dB
Typical:
0.25 dB
Return Loss
Maximum:
Trunk Insertion Loss (per meter)
850 nm
Maximum:
.0035 dB
Channel/Link Insertion Loss
with 31 meter (100') trunk
(as shown in figure above)
850 nm
Maximum:
1.1085 dB
Typical:
0.6085 dB
ENVIRONMENTAL
Storage Temperature:
Operating Temperature:
Installation Temperature:
5-8
1310 nm
1.0 dB
0.4 dB
-65 dB
1310 nm
.001 dB
1310 nm
2.031 dB
0.831 dB
-40° to 70° C (-40 to 158° F)
0° to 70° C (32 to 158° F)
0° to 70° C (32 to 158° F)
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiber Cable Products
ORDERING INFORMATION
Description
Length
Part Number
50/125 LOMMF to 300 m Cable Assemblies – OFNP rated; MPO pinned, 18" breakout
LC
SC
3m
MPA-PCLCJ30003M-NC
4m
MPA-PCLCJ30004M-NC
5m
MPA-PCLCJ30005M-NC
3m
MPA-PCSCJ30003M-NC
4m
MPA-PCSCJ30004M-NC
5m
MPA-PCSCJ30005M-NC
Singlemode Elite Cable Assemblies – OFNP rated; MPO pinned, 18" breakout
LC/UPC
SC/UPC
5-9
3m
MPA-PCLCJ50003M-NC
4m
MPA-PCLCJ50004M-NC
5m
MPA-PCLCJ50005M-NC
3m
MPA-PCSCJ50003M-NC
4m
MPA-PCSCJ50004M-NC
5m
MPA-PCSCJ50005M-NC
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/13 315802AE
FIBERGUIDE FIBER MANAGEMENT PRODUCTS
2x2 Horizontal FiberGuide.......................................................................................6-1
Vertical Solid and Slotted Duct Kits with Hinged Covers.....................6-3
Rack Installation for Small Fiber Deployments.......................................... 6-4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 313948AE
Connectivity Solutions for Distributed Antenna Systems
Fiberguide
FiberGuide Fiber Management Products
The FiberGuide fiber management systems offer the greatest breadth of optical raceway products in the industry. In response
to customer requirements, TE continues to innovate and improve FiberGuide systems, adding greater flexibility and driving
down installation time to ensure a smooth deployment.
FiberGuide is a raceway system designed to protect and route fiber optic patch cords, multi-fiber cable assemblies and
intrafacility fiber cable (IFC) to and from fiber splice enclosures, fiber distribution frames and fiber optic terminal devices.
FiberGuide ensures a two-inch minimum bend radius is maintained throughout the system. Tool-less, Snap-Fit™ junctions and
cover options significantly reduce the amount of time required for installation.
2x2 Inch System Fittings and Support Kits
ORDERING INFORMATION
Product Description
Part Number
2x2 Inch System Fittings
2x2 Horizontal Straight Section
6' long, cover included
FGS-MSHA-C
2x2 Junction
FGS-MJWR-C
2x2 Standard Downspout
Cover included
FGS-MSDS-C
2x2 Extended Downspout Kit with 2" Flex Tube
Cover included. with 2" flex tube, 2' long
FGS-KDH2-C
2x2 Horizontal T
Cover included
FGS-MHTA-C
2x2 End Cap
Includes 2x2 junction
FGS-HMEC-C
FGS-MSHA-C
FGS-MSDS-C
2x2 Inch System Support Kits
Aluminum Track Support Kit
6' long, includes track connecting bar kit; aluminum
track is self-supporting for spans up to 6'
FGS-HASK-C
Modified New Threaded Rod Bracket Kit 5/8"
FGS-HNTR-5/8-A
2x2 Existing Threaded Rod Bracket Kit
For up to two 2x2 FiberGuide systems
FGS-HTR2-2-5/8
Ladder Rack Bracket Kit 5/8"
6-1
FGS-HLDR-5/8
FGS-MJWR-C
FGS-KDH2-C
(shown attached to 2x2 FiberGuide system)
FGS-HASK-C
FGS-HNTR-5/8-A
(shown alone and attached to threaded rod)
FGS-MHTA-C
FGS-HMEC-C
FGS-HTR2-2-5/8
FGS-HLDR-5/8
(shown alone and attached to ladder rack)
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiberguide
2x2 Inch Attachments and Clamp Kit
ORDERING INFORMATION
Description
Part Number
Number of
Junctions
Yellow System
Black System
2x2 attachments
2x2 inch flex tube attachment – 2" flex tube and a 2x2 inch junction included
5' length
–
FGS-MEX1-C-5F
FGSB-MEX1-C-5F
10' length
–
FGS-MEX1-C-10F
FGSB-MEX1-C-10F
15' length
–
FGS-MEX1-C-15F
FGSB-MEX1-C-15F
Dual 7/8" flex tube attachment – two lengths of 7/8" flex tube and a 2x2 inch junction included
(2) 5' length
–
FGS-KT03-C
FGSB-KT03-C
(2) 10' length
–
FGS-KT03-C-10F
FGSB-KT03-C-10F
(2) 15' length
–
FGS-KT03-C-15F
FGSB-KT03-C-15F
–
FGS-HSHC-10
FGS-HSHC-10
Flex tube clamp kit of 10;
attaches 7/8" flex tube to rack
Other nonstandard colors available by request.
Dual 7/8" Flex Tube Attachment
(FGS-KT03-C)
Dual 7/8" Flex Tube Attachment
(FGS-KT03-C shown attached
to downspout)
6-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Fiberguide
Vertical Solid and Slotted Duct Kits with Hinged Covers
FEATURES
• Flexible and versatile system that
safely and securely routes fiber
• Provides 1.5-inch bend radius protection
• Provides superior cable management
on active equipment racks
• Available in 4-inch x 4-inch, 4-inch x
2-inch x 2-inch x 4-inch x 2-inch x 2-inch
• Hinged cover offer physical protection of
fiber and easy access to installed fibers
• Available in solid and slotted versions
• Made of robust and durable material
• Quickly installed onto existing rack
ORDERING INFORMATION
Product Description
Part Number
2X2 System (2" Wide x 2" Deep)
2X2, 6' Vertical Duct Kit, slotted (1.5" slot spacing) hinged cover
FGS-KTW1-JA
2X2, 6' Vertical Duct Kit, solid, hinged cover
FGS-KTW1-JN
2X4 System (2" Wide x 4" Deep)
2X4, 6' Vertical Duct Kit, slotted (2" slot spacing) hinged cover
2X4, 6' Vertical Duct Kit, solid, hinged cover
2x2 Solid Vertical Duct Kit
(FGS-KTW1-JN)
(cover closed)
FGS-KTW2-R
FGS-KTW2-RN
4X4 System (4" Wide x 4" Deep)
4X4, 6' Vertical Duct Kit, slotted (2" slot spacing) hinged cover
FGS-KTW2-K
4X4, 6' Vertical Duct Kit, slotted (4" slot spacing) hinged cover
FGS-KTW2-J
4X4, 6' Vertical Duct Kit, solid, hinged cover
FGS-KTW2-JN
4X2 System (4" Wide x 2" Deep)
4x2, 6' Vertical Duct Kit, slotted (1.5" slot spacing) hinged cover
4x2, 6' Vertical Duct Kit, solid, hinged cover
FGS-KTW2-T
FGS-KTW2-TN
Trumpets and Elbows
4" deep vertical to 2x2 Trumpet Fitting, yellow
FGS-TRMP42
4" Exit Trumpet for vertical channel, 1" bend radius, black
FGS-VQE44
2" Exit Trumpet for vertical channel, 1" bend radius, black
4x4 Entrance Trumpet Flare Kit
2x4 Solid Vertical Duct Kit
(FGS-KTW2-RN)
(cover open)
FGS-VQE22
FGS-MTRM-D
4" deep 90º Inside Elbow
FGS-V9E44
4x4 Slotted Vertical Duct Kit
(FGS-KTW2-J)
4-Inch Vertical to
2x2 Trumpet Fitting
(FGS-TRMP42)
6-3
2-Inch Exit Trumpet
(FGS-VQE22)
4-Inch Exit Trumpet
(FGS-VQE44)
4x4 Modified
Trumpet Flare Kit
(FGS-MTRM-D)
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
90° Inside Elbow
(FGS-V9E44)
Connectivity Solutions for Distributed Antenna Systems
Fiberguide
Sample 1 Rack Installation for Small Fiber Deployments
To/From Fiber
Termination Location
Existing Ladder Racking
4x4 End Cap
Express Exit
2" Flexible Tubing
New Threaded Rod Bracket Kit
(FGS-HNTR-XX shown alone and
attached to threaded rod)
2" Flex Tube Kit
4x4 Solid
Straight Section
2x2 Slotted Duct
Mounting kit determined
by existing infrastructure
Center Support Bracket Kit
(FGS-HTUB-XX)
7' x 19"
Bay
Ladder Rack Bracket Kit
(FGS-HLDR shown alone and
attached to ladder rack)
Sample FiberGuide Parts List
Quantity
Required
Part Number
Product Description
1
FGS-MSHS-A
4x4 horizontal straight section, 6' long, cover included
1
FGS-HMEC-A
4x4 end cap
1
FGS-KT03-A1
4x4 end cap with 2" flex tube attachment
1
FGS-KTW1-CA
2x2 vertical slotted duct kit, 1.5" slot spacing
1
FGS-MEX1-C-10F
2" flex tube attachment with 10' of flex tube
1
FGS-MEXP-A/B/F
3
FGS-HNTR-XX
New threaded rod bracket kit
3
FGS-HTUB-XX
Center support bracket kit
3
FGS-HLDR-5/8
Ladder rack bracket kit
6-4
2x2 Express Exit
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
WDM CHASSIS AND MODULES
Prism WDM Modules and Accessories............................................................. 7-1
Prism CWDM Chassis & Modules........................................................................7-4
VAM Chassis & Modules........................................................................................... 7-7
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 313948AE
Connectivity Solutions for Distributed Antenna Systems
WDM Chassis & Modules
FlexWave Prism Fiber Multiplexing Options - WDM
When it is desirable or necessary to combine transmit and receive path optical signals from one Prism system onto
a single optical fiber, use the Wavelength Division Multiplexer (WDM) system, which is an accessory product. Each
WDM system consists of a Host and a Prism Remote Unit (PRU). At the Host and PRU, a WDM chassis contains the
WDM modules. Both the Host WDM Module and the PRU WDM Module consist of a bi-directional wavelength division
multiplexer, as shown below.
1550nm
1310nm
1550nm
Host SFP
1310nm
Host WDM Module
1550nm Test port
(optional)
1310nm
1310nm
PRU SFP
1550nm
To/From
PRU
PRU WDM Module
1550nm
OSP
To/From
Host
To create a FlexWave Prism Wavelength Division Multiplexer (WDM) system, the following components are required:
•
•
•
•
7-1
Standard 26 dB Optics (Small Form Pluggable laser) 1550 nm at Host; 1310 nm at Remote
Host WDM Chassis to house eight (8) WDM modules
Host WDM module(s)
Remote OADM fiber cable assembly
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
WDM Chassis & Modules
Host WDM
The Host WDM module is mounted within a sheet metal enclosure. A straight LC-type optical connector port is
provided for connecting the transmit/receive path optical fiber to the WDM module. A pair of fiber patch cord leads
with LC-type connectors connects the WDM module to the TX/RX Optical ports on the Prism Host SeRF II card.
Below shows the WDM Host Module Mounting Shelf and Host Module.
Each WDM module supports a single Small Form-Factor Pluggable (SFP) port on the Host, but a WDM chassis can
support up to eight WDM modules, which allows the sharing of the WDM chassis among multiple Hosts, dependent on
the SFP port counts and system configuration. That is, the eight WDM modules allow a fully loaded Host with eight SFP
modules or multiple partially loaded Hosts (for a maximum of eight total SFPs). The WDM Host module-mounting shelf
installs in the equipment rack with the Host .
1
2
Ports
3
4
Port 1: 1550nm IN (TX)
Port 2: 1310nm OUT (RX)
Port 3: -23dB 1550nm Test port
Port 4: 1310/1550nm
7-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
NOTE:
Port 3 is a Trap port. When
taking a reading at this
port, the signal power is
23 dB less than the input
power going into Port 1.
The wavelength of light
measured is 1550 nm.
Connectivity Solutions for Distributed Antenna Systems
WDM Chassis & Modules
Remote WDM
The Remote WDM cable assembly is a fiber optic patch cord
with a WDM splitter built into it, the demultiplexed (separate
TX and RX paths) end of the WDM cable assembly is plugged
into the SFP in the Remote SeRF which are the LC UPC
connectors and multiplex side of the cable assembly plugged
into a Port in the ProAx fiber adapter, BX.5 style connector,
housed within the Prism Remote.
UPC LC
UPC Bx.5
Plugs into the
SPF in the SeRF
“15” = REV
“13” = FWD
WDM
WDM Ordering Information
ORDERING INFORMATION
Description
TE
Part Number
Standard 26dB Transceivers
Prism, Host Unit, 26dB optics, 1550nm, Standard
FWU-SMHU1550XVR
Prism, Remote Unit, 26dB optics, 1310nm, Standard
FWU-SMRU1310XVR
Host WDM
Prism, Host WDM Module
Prism, Host WDM Chassis; No active modules (8 slots)
Host Bay, WDM Module for WDB-UR002 Bay
Remote WDM Fiber Cable Assembly
Pass-through; required when using FWP-FFTKIT-02
7-3
FWU-27A7AAG1ABK00
FWU-CHASSIS-8
FMT-MW2KUKUBG1A00
FWU-REMOTEWDM
FWP-WDMKIT-FT
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Plugs into port 1
of Fiber 1 ProAx
Note: WDM
comes
preinstalled in the
Remote.
Connectivity Solutions for Distributed Antenna Systems
CWDM Chassis & Modules
FlexWave Prism Fiber Multiplexing Options - CWDM
When it is desirable or necessary to combine multiple transmit and receive path optical signals from one Prism system
to a single pair of optical fibers, use the Coarse Wavelength Division Multiplexer (CWDM) system, which is an accessory
product. Each CWDM system consists of a Host and a Prism Remote Unit (PRU). At the Host and PRU, a CWDM chassis
contains the CWDM 8 channel Muxtiplexer/Demultiplexer (Mux/DeMux) modules and at the Remote you will need an
Optical Add Drop Multiplexer (OADM) Splice Box and OADM cable assembly.
Host Unit
Host CWDM 8 Channel
Mux/DeMux
OSP
Remote Unit 8
Remote Unit 3
Remote Unit 2
Remote Unit 1
OADM Splice
Box with OADM
OADM Splice
Box with OADM
OADM Splice
Box with OADM
.…
OADM Splice
Box with OADM
To create a FlexWave Prism Coarse Wavelength Division Multiplexer (CWDM) system, the following components are required:
•
•
•
•
•
7-4
Host & Remote wavelength specific CWDM Optics/SFP (Small Form Pluggable laser)
Host CWDM Chassis to house the 8 Channel CWDM module
Host CWDM 8 channel module
Remote OADM splice box
Remote OADM assembly
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
CWDM Chassis & Modules
Host CWDM Multiplexer/DeMultiplexer Unit
The CWDM Multiplexer/DeMultiplexer (Mux/DeMux) connects to the Prism Host and performs the following functions:
–– In the Transmit (Tx) path, the Mux/
DeMux Unit provides eight (8) Tx channels
from the Host unit and multiplexes up to
eight (8) channels into a single fiber
–– In the Reverse (Rx) path, the Mux/DeMux
Unit separates up to eight wavelengths
The CWDM Mux/DeMux unit uses industry standard LC optical connections.
CWDM Optical Add Drop Multiplexer (OADM) Module
The CWDM OADM Assembly is used when it is desirable or necessary to combine the forward path or reverse path
optical signals onto a single optical fiber. The CWDM OADM Assembly is installed into the OADM Splice Box, is
wavelength dependent, and consists of Add and Drop modules of specific wavelengths. The CWDM OADM has fiber
optic pigtails for splicing into OSP fiber and ProAx or pigtail from the Prism Remote.
See figure below of OADM Assembly:
OUT FROM OADM 2, REV PRIM
OUT FROM OADM 1, REV SEC
FWD (DROP FROM OADM 1 & 2)
REV (ADD FROM OADM 1 & 2)
IN FROM OADM 2, FWD SEC
IN FROM OADM 1, FWD PRIM
22958-A
Part Number WSC-CH0-CW
7-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
CWDM Chassis & Modules
The maximum length of the optical links is dependent on the loss specifications of the optical fiber and the losses
imposed by the various connectors and splices. The system provides an optical budget of 26 dB (typical) when used
with 9/125 single-mode fiber. There must be at least 10 dB of optical loss to prevent over-driving and possible damage
to the optical receiver.
The optical wavelengths used in the Prism CWDM system are 1471nm, 1491nm, 1511nm, 1531nm, 1551nm, 1571nm, 1591nm
and 1611nm. The OADM assembly is installed in the OADM Splice Box which typically resides above or below the Prism
unit on a pole or wall; while the Host is connected to a Mux/DeMux that multiplexes the different wavelengths from the
transceivers onto a single fiber in the Forward path and de-multiplexes the wavelengths from the Remotes into their
respective wavelengths. At the Host there is a CWDM chassis that contains the CWDM Mux/DeMux Units, and at the
Remote the CWDM is spliced to the OSP fiber and HMFOC/MPO 8 Fiber cable or Pigtail from the Remote.
Below shows how the CWDM Mux/DeMux unit and the CWDM OADM Assembly multiplex and demultiplex wavelengths
in a non-redundant configuration:
FWD IN
HOST
URH
CWDM
SFP
1491
1471
1471
1471
OADM
1511
1531
1551
1571
1471
D
1491
A
8:1
MUX
D
FWD OUT
OADM
A
1591
1611
HOST
URH
CWDM
SFP
1511
FWD IN
1511
1491
D
OADM
A
1511
D
FWD OUT
OADM
A
1471
HOST
URH
CWDM
SFP
1551
1471
1551
1551
1571
1491
A
1:8
DMUX
D
FWD OUT
OADM
1591
REMOTE 3
URH
CWDM
SFP
1511
1511
D
OADM
1511
1531
1551
FWD IN
1491
REMOTE 1
URH
CWDM
SFP
1491
A
1511
REMOTE 5
URH
CWDM
SFP
1551
1611
FWD IN
HOST
URH
CWDM
SFP
1591
1611
OADM
1591
D
A
D
OADM
1591
A
1611
REMOTE 8
URH
CWDM
SFP
1591
Reverse path
Forward path
Below shows how the CWDM Mux/DeMux unit and the CWDM OADM Assembly multiplex and demultiplex wavelengths
in a redundant configuration:
7-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
VAM Chassis & Modules
Powering
The CWDM Fiber Cable Assembly and the Mux/DeMux are passive and do not require powering.
VAM Chassis
Coarse wavelength division multiplexer (CWDM) modules allow for the addition of eight additional signals to be
transmitted over a single fiber. This is done by dividing the 1550 nm window into eight 20 nm spaced channels. CWDM
electronics require the use of more precise and expensive lasers, but this cost can often be justified by the avoidance of
costs associated with installing new fiber cables.
TE’s WideVAM® family of products allows for an efficient integration of optical components into the optical distribution
frame. WideVAM chassis are available for industry standard 19- or 23-inch optical distribution frames. The WideVAM
chassis provides the utmost protection, modularity and flexibility for all optical component needs.
The Prism CWDM system works with TE’s 7- and 3.5-inch industry-standard WideVAM chassis to ensure consistent,
superior cable management within the frame.
3.5-INCH WIDEVAM CHASSIS - 2 WIDEVAM MODULE CAPACITY
The 3.5-inch WideVam VAM chassis fits into any 19-inch rack mounting environment. It accommodates a maximum of
4 plug-in modules, 4 bulkhead plates, 4 blank panels or any combination thereof. Adjustable mounting brackets are
provided for 23-inch rack mounting environments.
7-INCH WIDEVAM CHASSIS - 6 WIDEVAM MODULE CAPACITY
The 7-inch WideVam VAM chassis fits into any open chassis location within an existing TE 7-inch panel system or in an
LGX® compatible frame. It accommodates a maximum of six components, in any combination of the following: single
plug-in modules, bulkhead plates and blank panels.
The 7-inch chassis mounts in EI A or WECO racks. Adjustable mounting brackets are provided for 19- or 23-inch rack
mounting environments.
7-7
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
WDM Chassis & Modules
CWDM Specifications
Fiber Type
9/125, single-mode
Optical Connectors
Industry standard LC
2-Channel Module Insertion Loss
Pass-Through Ports
2 dB
Drop Port
5 dB
CWDM System Optical Budget
26 dB
CWDM Ordering Information
Description
TE
Part Number
CWDM Host Unit Mux/Demux & Chassis
WideVAM 8-Channel MUX/DEM Module (host) with LC
Chassis 7" WideVAM (supports 6 CWVMW-277AA0DN2000)
Chassis, WideVAM 2 Empty (supports 2 CWVMW-277AA0DN2000)
CWVMW-2KKAA0DN2000
FVM-19X700W
FVM-19X350W-M6
CWDM 26dB Transceivers (XCVR-SFP CWDM EXTTEMP)
1470NM
FWU-SMCW1470XVR
1490NM
FWU-SMCW1490XVR
1510NM
FWU-SMCW1510XVR
1530NM
FWU-SMCW1530XVR
1550NM
FWU-SMCW1550XVR
1570NM
FWU-SMCW1570XVR
1590NM
FWU-SMCW1590XVR
1610NM
FWU-SMCW1610XVR
CWDM Non-Redundant OADM Modules (external splice box needed)
1471 NM
FWP-OADM1471MOD-00
1491 NM
FWP-OADM1491MOD-00
1511 NM
FWP-OADM1511MOD-00
1531 NM
FWP-OADM1531MOD-00
1551 NM
FWP-OADM1551MOD-00
1571 NM
FWP-OADM1571MOD-00
1591 NM
FWP-OADM1591MOD-00
1611 NM
FWP-OADM1611MOD-00
CWDM Splice Box
Fiber Splice Box with CWDM Adapter Plate
7-8
WSC-CH0-CW
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
POWERWORX FUSE PANEL PRODUCTS
Traditional GMT..............................................................................................................8-1
Select Series....................................................................................................................8-1
Accessories......................................................................................................................8-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 313948AE
Connectivity Solutions for Distributed Antenna Systems
Powerworx
PowerWorx panels are independently tested to comply with the industry’s highest standards, including CE, IEC, UL,
NEBS Level 3, Telecordia (BellCore), CSA, and NEC 2002. Flexible PowerWorx configurations suit almost every network
application and the platform sets a new standard – delivering the power and the protection that service providers need.
FEATURES
• Flexible platform for use in MSCs,
DAS headends, or at cell sites
• Up to a 15-year warranty
• Compliant with all major standards, including UL, NEBS
Level 3, Telcordia (BellCore), NEC 2002, CSA, IEC, and CE
–– Collocate cabinet
–– BTS cabinet
• Backed by TE Connectivity quality, manufacturing
excellence and exceptional customer service
–– Hut
Traditional GMT Series
FEATURES
With input power up to 65 Amps per bus, the
Traditional GMT Series eliminates the need to stock
varying amperage fuse panels. Fuse management
is simplified by accommodating up to 15 Amps of
output power per fuse position – without the need
to space fuses. A self-configuring voltage and
polarity feature allows a single panel to support most
applications, providing ±24Vdc or ±48Vdc power.
• Standard front and rear access 1.75”H x 17.12”W x 8”D (4.44 x 43.48 x 20.32 cm)
• GMT fuse type
• LED configuration: Power on and
fuse alarm LEDs (per bus)
• EIA/WECO mounting options
• Powering Input - Two-hole compression lug (stud type)
• Powering Output- Screw-down barrier terminal strip
ORDERING INFORMATION
Panel
Access
Fuse
Configuration
Alarm Contact
Connection
Panel
Color
Part Number
Front
Dual front power
feed, 10/10-position
Screw-down barrier
terminal strip
Putty
PWX-001FGCSD10PSDP
Front and
Rear
Dual rear power
feed, 10/10-position
Screw-down barrier
terminal strip
Putty
PWX-001RGCSD10PSDP
FEATURES
Select Series™
As data and telephony converge, network elements with varying
amperage requirements are often mixed within the same bay. The
Select Series™ fuse platform enables service providers to fuse this
equipment from one platform, in a single rack unit, making the most of
valuable space. Its compact footprint and versatility are well-suited for
collocation applications where high-amperage equipment is installed
with lower-amperage equipment. Its patent pending modular design
enables service providers to combine TPA, KTK/KLM, TPM or GMT
fuses within a single rack unit. Input power up to 100 Amps per bus
with up to 50 Amps output power per fuse position is available.
• Dimensions - 1.75”H x 17.12”W x 10”D
(4.44 x 43.48 x 25.4 cm)
• Front and rear access
• GMT, TPA and KLM fuse type
• Powering Input - Two-hole
compression lug (stud type)
• Powering Output- Screwdown barrier terminal strip
• Dual bus configuration
• EIA/WECO mounting options
ORDERING INFORMATION
• Putty white panel color
Fuse
Configuration
LED
Configuration
Alarm Contact
Connection
Part Number
4 KLM, 4 GMT
Power on and fuse
alarm LEDs
Wire-Wrap
PWX-041RCK4G4YSPWP
4 TPA, 4 GMT
Power on and fuse
alarm LEDs
Wire-Wrap
PWX-041RCA4G4YSPWP
8-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Powerworx
Accessories
Cable Management Bars For Standard
(Front and Rear Access) Fuse Panels
ORDERING INFORMATION
Cable management bar
Part Number
Putty white - 19"
CMB-P-19
Putty white - 23"
CMB-P-23
Compression Lugs For Two-Hole Stud-type Input Power Connections
Compression lugs provide a robust and reliable
electro-mechanical connection.
ORDERING INFORMATION
Compression lug; ships two per pack
Part Number
2 AWG
CL-02M
4 AWG
CL-04M
6 AWG
CL-06M
14 AWG
CL-14M
Designation Card Holder and Cards
Designation cards held in pressure-sensitive card holder enable
easy identification and location of fused equipment.
ORDERING INFORMATION
Designation card holder kit Includes:
8-2
1 plastic designation card holder,
2 designation cards and window
Part Number
DCK-02
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Powerworx
Accessories
GMT Fuses/Fuse Designation Pins – Alarm Indicator
ORDERING INFORMATION
GMT fuses/fuse designation pins - alarm indicator
Fuse Size
Color of Indicator/
Designation Pin
Fuse Part
Number
Black-Red
Violet
White-Green
Red
Brown
Gray
White
White-Yellow
Orange
Orange-White
Blue
White-Blue
White-Brown
Green
Black-White
Red-White
Yellow-Green
Red-Blue
F-2/10
F-1/4
F-3/8
F-1/2
F-3/4
F-1
F-1 1/3
F-1 1/2
F-2
F-2 1/2
F-3
F-3 1/2
F-4
F-5
F-7 1/2
F-10
F-12
F-15
GMT Dummy
F-20
2/10 Amps
1/4 Amps
3/8 Amps
1/2 Amps
3/4 Amps
1 Amps
1-1/3 Amps
1-1/2 Amps
2 Amps
2-1/2 Amps
3 Amps
3-1/2 Amps
4 Amps
5 Amps
7-1/2 Amps
10 Amps
12 Amps
15 Amps
Dummy GMT
20 Amps
Pin Part
Number
P-2/10
P-1/4
P-3/8
P-1/2
P-3/4
P-1
P-1 1/3
P-1 1/2
P-2
P-2 1/2
P-3
P-3 1/2
P-4
P-5
P-7 1/2
P-10
P-12
P-15
KLM Fuses – Non-Indicator1
The compact puller grips firmly to remove GMT fuses.
KLM fuses - non-indicator
Part Number
5 Amps
KLM-05
10Amps
KLM-10
15Amps
KLM-15
20Amps
KLM-20
25Amps
KLM-25
30Amps
KLM Dummy
KLM-30
KLM Dummy
All KLM fuse modules house a fuse alarm indicating red LED.
1
KLM Fuse Panel Cap
KLM fuse panel cap
Cap for KLM fuse panel
8-3
Part Number
KLM-CAP
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Powerworx
Accessories
Ring Lug Kit
Ring lug kit
Part Number
100 Piece, 16-22 AWG
RLK-001
20 Piece, 8 AWG
RLK-002
20 Piece, 10 AWG
RLK-003
Compression Lugs
For Two-Hole Stud-type Input Power Connections
Compression lugs provide a robust and reliable electro-mechanical connection.
Compression lugs; ships two per pack
Part Number
2 AWG
CL-02M
1 AWG
CL-01M
1/0 AWG
CL-01M0
2/0 AWG
CL-02M0
3/0 AWG
CL-03M0
4/0 AWG
CL-04M0
250 KCMil
CL-250M
300 KCMil
CL-300M
350 KCMi
CL-350M
8-4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
DATA CONNECTIVITY
Category 6 Slim Line Patch Cable Assemblies............................................9-1
Category 6 Ethernet Crossover Cable Assemblies....................................9-1
Category 6 SL Series Patch Panels....................................................................9-2
Twisted Pair Cable Information............................................................................9-3
Twisted Pair Cable Temperature..........................................................................9-3
4-Pair Conductor Color Code...............................................................................9-3
610 Series, Category 6 UTP Cable......................................................................9-3
620 Series, Category 6 UTP Cable................................................................... 9-4
630 Series, Category 6E UTP Cable................................................................ 9-4
Category 6, 8-Position Modular Plug................................................................9-5
Modular Plug Boots for Category 6 Modular Plugs.................................9-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 313948AE
Connectivity Solutions for Distributed Antenna Systems
Data Connectivity
Category 6 Slim Line Patch Cable Assemblies
FEATURES
• Slim plug and boot design provide additional space between adjacent plugs
• Meets or exceeds Category 6 performance standards
• 4-Pair stranded Unshielded 24 AWG conductors
• Non-plenum (CM rated)
• Universal wiring (T568A/T568B)
• Lead-Free (no heavy metals)
• Colors in table are approximate
Length
2 ft [0.61 m]
Black
Gray
Blue
Green
1933116-2
1933117-2
1933118-2
1933119-2
Red
1933120-2
White
Yellow
Orange
1933121-2
1933122-2
1933123-2
Violet
1933124-2
3 ft [0.91 m]
1933116-3
1933117-3
1933118-3
1933119-3
1933120-3
1933121-3
1933122-3
1933123-3
1933124-3
4 ft [1.22 m]
1933116-4
1933117-4
1933118-4
1933119-4
1933120-4
1933121-4
1933122-4
1933123-4
1933124-4
5 ft [1.52 m]
1933116-5
1933117-5
1933118-5
1933119-5
1933120-5
1933121-5
1933122-5
1933123-5
1933124-5
6 ft [1.83 m]
1933116-6
1933117-6
1933118-6
1933119-6
1933120-6
1933121-6
1933122-6
1933123-6
1933124-6
7 ft [2.13 m]
1933116-7
1933117-7
1933118-7
1933119-7
1933120-7
1933121-7
1933122-7
1933123-7
1933124-7
8 ft [2.44 m]
1933116-8
1933117-8
1933118-8
1933119-8
1933120-8
1933121-8
1933122-8
1933123-8
1933124-8
9 ft [2.74 m]
1933116-9
1933117-9
1933118-9
1933119-9
1933120-9
1933121-9
1933122-9
1933123-9
1933124-9
10 ft [3.05 m]
1-1933116-0
1-1933117-0
1-1933118-0
1-1933119-0
1-1933120-0
1-1933121-0
1-1933122-0
1-1933123-0
1-1933124-0
12 ft [3.66 m]
1-1933116-2
1-1933117-2
1-1933118-2
1-1933119-2
1-1933120-2
1-1933121-2
1-1933122-2
1-1933123-2
1-1933124-2
14 ft [4.27 m]
1-1933116-4
1-1933117-4
1-1933118-4
1-1933119-4
1-1933120-4
1-1933121-4
1-1933122-4
1-1933123-4
1-1933124-4
15 ft [4.57 m]
1-1933116-5
1-1933117-5
1-1933118-5
1-1933119-5
1-1933120-5
1-1933121-5
1-1933122-5
1-1933123-5
1-1933124-5
16 ft [4.88 m]
1-1933116-6
1-1933117-6
1-1933118-6
1-1933119-6
1-1933120-6
1-1933121-6
1-1933122-6
1-1933123-6
1-1933124-6
20 ft [6.10 m]
2-1933116-0
2-1933117-0
2-1933118-0
2-1933119-0
2-1933120-0
2-1933121-0
2-1933122-0
2-1933123-0
2-1933124-0
25 ft [7.62 m]
2-1933116-5
2-1933117-5
2-1933118-5
2-1933119-5
2-1933120-5
2-1933121-5
2-1933122-5
2-1933123-5
2-1933124-5
30 ft [9.14 m]
3-1933116-0
3-1933117-0
3-1933118-0
3-1933119-0
3-1933120-0
3-1933121-0
3-1933122-0
3-1933123-0
3-1933124-0
40 ft [12.19 m]
4-1933116-0
4-1933117-0
4-1933118-0
4-1933119-0
4-1933120-0
4-1933121-0
4-1933122-0
4-1933123-0
4-1933124-0
50 ft [15.24 m] 5-1933116-0
5-1933117-0
5-1933118-0
5-1933119-0
5-1933120-0
5-1933121-0
5-1933122-0
5-1933123-0
5-1933124-0
Category 6 Ethernet Crossover Cable Assemblies
FEATURES
• Category 6 crossover cables are compatible with 10/100BASE-T, as well as IEEE 802.3 1000BASE-T
• For other lengths and wiring diagrams, see Customer Drawing
• Lead-Free (no heavy metals)
• Features black plug boots and red cable
Description
Category 6 Ethernet
Crossover Cable
Assemblies
9-1
Cable/Boot Color
Red/Black
Length
Part Number
3 ft [0.91 m]
1499150-3
5 ft [1.52 m]
1499150-5
7 ft [2.13 m]
1499150-7
10 ft [3.05 m]
1-1499150-0
12 ft [3.66 m]
1-1499150-2
15 ft [4.57 m]
1-1499150-5
25 ft [7.62 m]
2-1499150-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Data Connectivity
Category 6 SL Series Patch Panels
• Meets or exceeds TIA and ISO Category 6
component performance requirements
Back of Interface
housing
• Angled panels allow elimination of horizontal cable management
for higher rack densities and ease of cable dress
• Ports may be individually replaced
• A
ll panels are packaged unloaded with jacks bagged separately
for termination with SL Series Jack Termination Tool
A
Front of Interface
housing
• Universal wiring – may be terminated to T568A or T568B
• Replacement labels and clear label covers
• 12-Port Mini Patch Panels mount vertically on 89D bracket (included)
• 48-port, 1U patch panels:
• Accommodate adhesive labels or icons for port identification
B Angled
• Are supplied with 48 specially designed SL Series jacks (these jacks can not
be purchased separately – they are supplied with panel assembly only)
• For multimedia (no included connectivity) patch panels
C Standard
• Accommodates icons
Port
Count
Rack
Mount
Units
12
24
C Angled
Height
Width
Figure
Standard
Angled
–
10.00 in [25.40 cm]
2.3 in [5.84 cm]
A
1375013-2
–
1
1.75 in [4.44 cm]
19.0 in [48.26 cm]
B
1375014-2
1499600-2
1
1.75 in [ cm]
19.0 in [48.26 cm]
C
1933458-1*
1933658-1*
2
3.50 in [8.89 cm]
19.0 in [48.26 cm]
D
1375015-2
1499601-2
4
7.00 in [17.78 cm]
19.0 in [48.26 cm]
1375016-2
–
D Standard
48
96
*NOTE: 1U 48-port panel does not accept standard SL Series jacks
9-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
D Angled
Connectivity Solutions for Distributed Antenna Systems
Data Connectivity
Twisted Pair Cable Information
Unless otherwise specified, all lengths are 1000 feet (305 meters). Other lengths
and colors available, call for details. Package types are listed in each chart.
WR = Wooden Reels
Twisted Pair Cable Temperature
Category
Condition
Riser/Plenum
Cat 6, 6E
Storage
-4 — 140°F (-20 — 60°C)
Operating
-4 — 140°F (-20 — 60°C)
Installation
40 — 140°F (4 — 60°C)
RB = Reel-in-a-Box
4-Pair Conductor Color Code
Tip Conductor
Pair
PB = Pull Box
Ring Conductor
Jacket Color
1
2
Tip
White
Ring
Blue
Tip
White
Ring
Orange
3
Tip
White
Ring
Green
4
Tip
White
Ring
Brown
TWISTED PAIR
610 Series, Category 6 UTP Cable
• Performance characterized to 250 MHz
• Meets ANSI/TIA-568-C.2 Category 6 and ISO Class E 11801: 2002 specifications
• Intertek ETL SEMKO Listed (CMR/CMP)
Jacket
• Exceeds all requirements for Gigabit Ethernet
Conductor
• Lead-free (no heavy metals)
Insulation
• 23 AWG, solid conductors
UL/NEC
Ratings
CMP
9-3
Part Numbers
Pair
Count
Package
White
Gray
Blue
Yellow
Weight
lbs/kft
Vp
(%nom)
4
RB
1933047-2
1933047-4
1933047-6
1933047-8
24
74
WR
1933047-1
1933047-3
1933047-5
1933047-7
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Cat6 min
Dimensions (in)
Dielectric
Outside
0.040
0.206
Connectivity Solutions for Distributed Antenna Systems
Data Connectivity
620 Series, Category 6 UTP Cable
• Performance characterized to 600 MHz
• 3 dB NEXT performance above Category 6
• Meets or exceeds ANSI/TIA-568-C.2 Category 6 and
ISO Class E 11801: 2002 specifications
• Intertek ETL SEMKO Listed (CMR/CMP)
• Independently verified by Intertek ETL SEMKO testing services
Jacket
• Exceeds all requirements for Gigabit Ethernet
Core Filler
• Lead-free (no heavy metals)
Conductor
Insulation
• 23 AWG, solid conductors
UL/NEC
Ratings
Pair
Count
Package
CMR
4
CMP
4
Part Numbers
White
Gray
Blue
Yellow
RB
219560-2
219560-4
219560-6
219560-8
WR
219560-1
219560-3
219560-5
219560-7
RB
219567-2
219567-4
219567-6
219567-8
WR
219567-1
219567-3
219567-5
219567-7
Cat6
Weight
lbs/kft
Vp
(%nom)
Dimensions (in)
Dielectric
Outside
26
70
0.042
0.230
24
74
0.040
0.206
Jacket
Core Filler
Conductor
Insulation
Jacket
630 Series, Category 6E UTP Cable
Core Filler
Cat6e
Conductor
Insulation
• Performance characterized to 600 MHz
• 12 dB NEXT performance above Category 6
Cat6
• Meets
or exceeds ANSI/TIA-568-C.2 Category 6 and
ISO 11801: 2002 Class E specifications
• Intertek ETL SEMKO Listed (CMR/CMP)
• Independently verified by Intertek ETL SEMKO testing services
Jacket
• Exceeds all requirements for Gigabit Ethernet
Core Filler
• Lead-free (no heavy metals)
Conductor
Insulation
• 23 AWG, solid conductors
UL/NEC
Ratings
Pair
Count
Package
CMR
4
CMP
4
9-4
Part Numbers
White
Gray
Blue
Yellow
RB
1499038-2
1499038-4
1499038-6
1499038-8
WR
1499038-1
1499038-3
1499038-5
1499038-7
RB
1499033-2
1499033-4
1499033-6
1499033-8
WR
1499033-1
1499033-3
1499033-5
1499033-7
Weight
lbs/kft
Vp
(%nom)
Dimensions (in)
Dielectric
Outside
34
70
0.042
0.260
35
74
0.040
0.245
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Cat6e
Connectivity Solutions for Distributed Antenna Systems
Data Connectivity
Category 6, 8-Position Modular Plug
• Each kit includes:
1 - Modular plug assembly
1 - Wire holder
1 - Strain relief
• RoHS compliant
• Molded with UL94V-0 plastic
• UL Listed: E81956
• Category 6 modular plug tooling in Chapter 22
• Modular plug to die set cross reference on page 2 of this chapter
Description
Unshielded
or
Shielded
Conductor
Insulation O.D.
in (mm)
Cable Jacket O.D.
in (mm)
Solid
24 – 23 AWG
0.035 (0.89) - 0.043 (1.09)
0.20 (5.0) — 0.24 (6.0)
5-1375204-4
5-1375204-3
5-1375204-4
0.035 (0.89) - 0.043 (1.09)
0.24 (6.0) — 0.28 (7.0)
5-1479185-4
5-1479185-3
5-1479185-4
Stranded
26 – 24 AWG
0.035 (0.89) - 0.043 (1.09)
0.20 (5.0) — 0.24 (6.0)
5-1375202-4
5-1375202-3
5-1375202-4
0.035 (0.89) - 0.043 (1.09)
0.24 (6.0) — 0.28 (7.0)
5-1479184-4
5-1479184-3
5-1479184-4
500 per Box
Modular Plug Boots for Category 6 Modular Plugs
• For use with Category 6, 8-Position modular plugs
• Accept cables with diameters as listed
• Colors in table are approximate
Maximum Cable O.D.
6 mm [0.24 in]
Maximum Cable O.D.
6.5 mm [0.26 in]
Color
2400 Per Box
100 Per Box
2400 Per Box
100 Per Box
White
2-737893-1
9-737893-1
2-336513-1
9-336513-1
Gray
2-737893-2
9-737893-2
2-336513-2
9-336513-2
Red
2-737893-3
9-737893-3
2-336513-3
9-336513-3
Blue
2-737893-4
9-737893-4
2-336513-4
9-336513-4
Green
2-737893-5
9-737893-5
2-336513-5
9-336513-5
Yellow
2-737893-6
9-737893-6
2-336513-6
9-336513-6
Black
2-737893-7
9-737893-7
2-336513-7
9-336513-7
Orange
–
–
2-336513-8
9-336513-8
Violet
–
–
2-336513-9
9-336513-9
9-5
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
100 per Box
25 per Box
RACK HARDWARE & ACCESSORIES
Equipment Racks........................................................................................................ 10-1
Hinged Wall Brackets for 19-Inch Panels .....................................................10-2
Double-Sided High-Density Vertical Cable Managers...........................10-3
Horizontal High-Density Cable Management.............................................10-3
High-Density Cable Management Accessories.........................................10-4
Horizontal Finger Duct Panels and Accessories.......................................10-5
Vertical Finger Duct Panels..................................................................................10-5
Hinged Patch Panel Accessories.......................................................................10-6
Horizontal Ringed Cable Management Panels..........................................10-6
Rack Mount Cable Trough.................................................................................... 10-7
Cable Support Bars.................................................................................................. 10-7
MRJ21 Cable Support Bars...................................................................................10-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Equipment Racks
TE Connectivity offers a variety of rack options with two and four post racks to
support todays moden telecommunications infrastructure. All racks are designed
of high quality materials and construction to meet TIA, EIA and IEEE requirements.
Each rack features mounting hole patterns per EIA-310-E standards.
FEATURES
• Available in two and four post designs
• Made of 6061-T6 aluminum alloy
• Flat black powder coat finish
• Features pre-tapped #12-24 mounting holes
• Shipped unassembled with all components and instructions required to
assemble a fully functional rack
• Feature double sided, EIA universal rails with 0.625" (16 mm),
0.625" (16 mm), 0.5" (13 mm) mounting spaces
• Three inch deep, two post rack features include:
–– Universal junction hole pattern
–– Conformance to EIA-310-E
• Two post, high capacity network equipment racks offer increased cable
capacity over standard racks. Features include:
–– Large vertical cable duct for increased cable capacity and D-rings for
out-of-the-box cable management
–– Large side cable pass-thru holes for rack-to-rack cabling
Figure A
–– Adjustable waterfalls on top cable management trays
Figure B
–– Top angles with pre-drilled mounting holes for runway attachment
–– Can be assembled for either 19" or 23" equipment
• Four post network equipment racks offer stability, accessibility and open
cooling with industry standard features. Features include:
–– Nearly 360° of access – completely open to allow excess heat from
equipment to quickly dissipate
–– Stamped, RMU (rack mount unit) markings conform to EIA-310-E
Figure C
ORDERING INFORMATION
Description
Channel Depth
Width (inches)
Height RMU (inches)
Figure
2 Post Rack
3"
19
45 (84)
A
1933559-1
2 Post Rack with Vertical
Cable Management
6"
19 or 23
45 (84)
B
1933560-1
4 Post Rack
3"
19
45 (84)
C
1933570-1
10-1
Part Number
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Hinged Wall Brackets for 19-Inch Panels
FEATURES
• Can be installed with hinges on either side for easier access
• Provided with cable tie laces to aid in dressing cables, have multiple threaded
holes allowing more than one panel to be mounted on a bracket, and rear
entry cable holes
Figure A
ORDERING INFORMATION
Panel Height
Depth
Figure
Part Number
1RU (1.75")
6"
2RU (3.5")
6"
558266-1
3RU (5.25")
6"
558268-1
4RU (7.00")
6"
558269-1
6RU (10.50")
6"
2111279-1
A
558267-1
Figure A 1U
Blank Panels
FEATURES
• 19" wide panels are designed for use in filling equipment rack voids
Figure B 1U
ORDERING INFORMATION
Description
Figure
1U [1.75"]
2U [3.50"]
3U [5.25"]
4U [7.00"]
5U [8.75"]
Standard
A
556965-1
556965-2
556965-3
556965-4
556965-5
Angled
B
1479992-1
1479992-2
–
–
–
10-2
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Figure B 2U
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Double-Sided High-Density Vertical Cable Managers
FEATURES
• Standard fingers are spaced 1RU vertically and are 8.5" deep
• Gates have 9RU vertical spacing and are 8.5" deep
• Two-piece doors with snap on hinges allow for quick opening from either side
or complete removal
• Six snap-on gates retain cables when doors are opened or removed
• Easy installation, can be done in minutes using standard hand tools
• Works with EIA-310-E compliant two and four post equipment racks using
industry standard mounting holes
• 1/4" accessory mounting holes run the full height on both sides of cable
manager to accommodate the attachment of cable management accessories
• S
eparator panel with pass through openings, vertical slots for attaching straps
and keyhole slots for attaching spools, included with each manager
• Front and rear vertical sections can be spaced apart when mounting on racks
deeper than 3" (76 mm)
Figure A
Figure B
• Flat black powder coat aluminum with UL 94V-0 black plastic components
• Vertical cable managers include:
–– Front and Rear vertical cabling section, (4) doors, (6) gates, (50) push-in
fasteners, (12) cable strap mounts, Separator panel and mounting hardware
–– On 10" and 12" wide cable managers only: (2) spool kits are included
ORDERING INFORMATION
Part Number
Description
Figure
Front/Rear Duct Type
6"Width
10" Width
12" Width
High-Density Vertical Cable Manager, 84", Double-sided
A
Standard Fingers/ Standard Fingers
1933534-1
1933535-1
1933536-1
High-Density Combination Vertical Cable
manager, 84", Double-sided
B
Standard Fingers/Gates
1933540-1
1933541-1
1933542-1
Horizontal High-Density Cable Management
FEATURES
• Snap-on removable hinged door remains open past 180°
• #12-24 mounting hardware is included
• Flat black powder coat aluminum with UL 94V-0 black plastic components
Single Sided
• Standard fingers are 5.5" deep
ORDERING INFORMATION
Part Number
Rack Mount Units (Height)
Single Sided
Double Sided
19"
Standard Fingers
1933530-1
1933531-1
2RU
19"
Standard Fingers
Extended Fingers
1933532-1
1933566-1
1933533-1
1933567-1
3RU
19"
Standard Fingers
1933561-1
1933562-1
1RU
10-3
Width
Finger Type
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Double Sided
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
High-Density Cable Management Accessories
FEATURES
• Replacement door kits:
–– Include an upper and lower door section
–– Are for use with high-density double-sided and double-sided combination
vertical cable managers
• Finger brackets (Figure A):
Figure A
–– High-density finger bracket mounts directly to a relay rack and provides
cable support at each rack mounting unit
–– Fingers align with rack mounting units
–– Includes (1) finger bracket and mounting hardware
–– Flat black powder coat aluminum bracket with UL 94V-0 black plastic
finger section
• Cable spools (Figure B):
–– Provide 1.1" (28 mm) bend radius
–– Cable spools attach quickly to keyhole slots provided in mounting channels
and optional back covers
Figure B
–– Facilitates storage and routing of cable
–– Unique spool kit design provides for vertical and horizontal adjustability to
suit any need
–– Spool kits includes (2) spools, mounting channels and hardware
–– Flat black powder coat steel with UL 94V-0 black plastic
• Fasteners (Figure C):
–– Used to quickly attach accessories to 1/4" (6 mm) mounting holes in
cable manager
–– Can be easily removed for relocation
–– Standard pack: 100 pieces
Figure C
–– Black plastic UL 94V-2
• Cable strap mounts (Figure D):
–– Provides attachment for cable straps up to 3/4" (19 mm) wide
–– Attach with push-in fastener 1933554-1 to 1/4" (6 mm) accessory mounting
holes in cable manager
–– Standard pack: 100 pieces
–– Black plastic UL 94V-0
Figure D
ORDERING INFORMATION
Description
Part Number
Figure
Replacement Door Kits
6" Width
10" Width
12" Width
1933556-1
1933557-1
1933558-1
Part Number
Finger Bracket
A
1933552-1
Cable Spools
B
1933553-1
Fasteners
C
1933554-1
Cable Strap Mounts
D
1933555-1
10-4
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Horizontal Finger Duct Panels and Accessories
FEATURES
• Cable management accessories for EIA standard 19-inch equipment racks
Figure A - Standard Cover
• Suitable
for high-performance twisted pair and optical fiber distribution
cables and patch cords
• Horizontal finger duct panels available in single and double-sided versions
• Extended covers bridge the gap between finger duct and vertical
cable management
Figure B - Standard Cover
ORDERING INFORMATION
Part Number
Description
Panel Height Front (HxD)
Single Sided
1RU (1.75")
2RU (3.50")
Cable Management Panel
Double Sided
1RU (1.75")
Rear Replacement Covers
Rear (HxD)
Extended Covers
–
1375161-1
1375161-2
1.5" x 3"
–
1375162-1
1375162-2
3.0" x 3"
–
1.5" x 2"
1" x 4"
Figure
A
1375163-1
1375163-2
1375160-1
1375160-2
1375159-1
1375159-2
1375158-1
1375158-2
1.5" x 3"
1" x 4"
3.0" x 3"
2" x 4"
1RU (1.75")
–
–
1479225-1
1479225-2
2RU (3.50")
–
–
1479222-1
1479222-2
1RU (1.75")
–
–
1479224-1
–
2RU (3.50")
–
–
1479223-1
–
2RU (3.50")
Front Replacement Covers
Standard Covers
1."5 x 2"
B
Vertical Finger Duct Panels
FEATURES
• Cable management accessories for EIA standard 19-inch equipment racks
• Suitable for high-performance twisted pair and optical fiber distribution cables and
patch cords
• Vertical finger duct panels available in single and double-sided versions
• Center mount vertical finger duct panels mount between racks for added stability
ORDERING INFORMATION
Description
Figure A
Mounting Position
Side Mount
Single-Sided
Center Mount
Side Mount
Double-Sided
Center Mount
10-5
Panel Height
Front (W x D)
35"
4" x 5"
78"
4" x 5"
35"
4" x 5"
Rear (W x D)
Figure B
Figure
Part Number
A
1375165-1
B
1375167-1
A
1375164-1
1375258-1
78"
4" x 5"
35"
4" x 5"
4" x 5"
1375260-1
78"
4" x 5"
4" x 5"
35"
4" x 5"
4" x 5"
78"
4" x 5"
4" x 5"
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
1375257-1
B
1375166-1
1375259-1
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Hinged Patch Panel Accessories
FEATURES
• For use with standard patch panels for hinged application where access
behind patch panel is limited
• Hinged
feature allows patch panel to be folded down for easy access to the
back of the panel, while snapping securely into place for normal use
Figure A
• Cable management panels have special ring spacing for hinged applications
• Hinged
panels may not be stacked adjacent to one another in a rack without
a cable management panel with a 1/2" of empty space between them
Figure B
ORDERING INFORMATION
Description
Rack Mount Units
Figure
1RU (1.75”)
Patch Panel Hinge Kit
1479582-1
2RU (3.50”)
A
1RU (1.75”)
Cable Management Panel
for Hinged Patch Panels
Part Number
1479402-1
1479732-1
2RU (3.50”)
B
1479733-1
Open
Closed
(Installed)
Horizontal Ringed Cable Management Panels
FEATURES
• Panels mount to the front of 19-inch racks and provide for the orderly dressing
and routing of cable assemblies
• Threaded studs on the back of the panels allow the installation of an optional
Cable Support Bar (see this chapter)
Figure A
• 2U (3.50") 569049-1 comes with cable clips
ORDERING INFORMATION
Figure B
Description
Height
Figure
1RU Panel
1.75"
A
558329-1
2RU Panel
3.50"
B
558331-1
10-6
Part Number
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
Rack Mount Cable Trough
FEATURES
• Light weight durable 11 AWG aluminum
Figure A
• Fit standard 19-inch racks
• Top trough features:
–– Down-radiused cable exit to vertical cable management
–– Dimensions (overall): 4.20" H x 19.00" W x 3.75" D
–– Mounts in 1RU (1.75") of rack space
Figure B
• Bottom/middle trough features:
–– Dimensions (overall): 5.22" H x 19.00" W x 3.75" D
–– Mounts in 3RU (5.25") of rack space
• Mounts to standard EIA hole pattern
• Provide cable management within the rack bay or multiple rack line-ups
ORDERING INFORMATION
Description
Figure
Top Trough
A
Part Numbers
559370-1
Bottom/Middle Trough
B
559369-1
Figure A
Cable Support Bars
Figure B
FEATURES
• Designed to provide additional cable support and routing control
in the rear of 19-inch racks and panels
Figure C
• C
able support bars that mount directly to rack provide the best
support. Other bars are available for specialty application
ORDERING INFORMATION
Mounting
Figure
Compatible with Panel
Part Number
Mounts to Back of Rack, 5" deep
A
557548-1
Mounts to Back of Rack, 2" deep
B
406042-1
Mounts to Back of Cable Management Panels
558329, 558331
Mounts to Back of 110Connect and SL Series Patch Panels
Mounts to Back of 1RU XG and SL Series Multimedia Patch Panels
10-7
558301-1
1479860-1
C
1933425-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Rack Hardware & Equipment
MRJ21 Cable Support Bars
FEATURES
• Mounts to the back of 19-inch racks
• Designed to provide additional cable support and routing control behind
19-inch racks and panels
Figure A
Figure B
• MRJ21 slotted manager bar for easy tie down
• Horizontal and vertical mounting option for MRJ21 tie down bar
ORDERING INFORMATION
Description
MRJ21 Cable Manager Bar
10-8
Depth
Figure
Part Number
6"
A
1933352-1
9"
B
1933352-2
12"
C
1933352-3
16"
D
1933352-4
Figure C
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Figure D
MISCELLANEOUS
DAS integration panel................................................................................................11-1
Empty Multifunction Chassis.................................................................................11-2
DS1, DS3 and Category 5e Modules..................................................................11-2
Fiber Connector/Adapter Cleaning Kit............................................................11-3
Private Network MPO Connector Cleaning Kit...........................................11-3
Fiber Inspection Kit................................................................................................... 11-4
NEOCLEAN Stick Cleaner...................................................................................... 11-5
LC and SC Connector Cleaner (In Bulkhead Cleaner)........................... 11-5
Protective Tubing Cutting Tool........................................................................... 11-6
Grounding Kit................................................................................................................ 11-6
Grounding/Moisture Blocking Kits.................................................................... 11-6
Velcro Cable Ties ........................................................................................................11-7
AMP-TY Nylon Cable Ties.......................................................................................11-7
Grounding Lug Kit.......................................................................................................11-7
Vertical Cable guide kit........................................................................................... 11-8
Adapters.......................................................................................................................... 11-8
Attenuators...................................................................................................................11-10
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 10/13 315802AE
Connectivity Solutions for Distributed Antenna Systems
DAS Integration Panel
The DAS Integration Panel provides a structured component interface between
the RF source and DAS host units. A single DAS Integration Panel can combine
up to three BTS with up to four DAS Main Hubs/Host Units. The DAS Integration
Panel contains all required RF components, thus reducing installation complexity
and labor costs. The DAS Integration Panel is compatible with InterReach Unison,
Fusion, and Spectrum, and FlexWave Prism products.
Front
PRODUCT HIGHLIGHTS
• Single panel integrates up to three BTS for connection
to Distributed Antenna System (DAS)
• Configurable for duplex or simplex operation on each BTS
• Low PIM (Passive Intermodulation) design
• Separate DL power level adjustments, 0 to 50 dB in 1 dB steps
• Common UL power level adjustment, 0 to 50 dB in 1 dB steps
• 85 dB isolation between DL and UL
• Configurable for one to four Main Hubs/Host Units
• No electrical power required
• Each chassis is band specific
• 19 inch rack mountable, 3U high chassis
• DIN 7/16 connectors at duplex ports for low PIM performance
• N Female connectors at all other ports
• Compatible with InterReach Unison, Fusion, Spectrum, and Flexwave Prism DAS
ORDERING INFORMATION
Description
Part Number
850 MHz DAS Integration Panel
INP-850-1
1900 MHz DAS Integration Panel
INP-1900-1
850 and 1900 MHz DAS Integration Panel
INP-8519-1
700 MHz (Lower ABC) DAS Integration Panel
INP-700ABC-1
700 MHz (Upper C) DAS Integration Panel
INP-700UC-1
AWS DAS Integration Panel
INP-AWS-1
11-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Back
Connectivity Solutions for Distributed Antenna Systems
DAS Integration Panel
DAS INTEGRATION PANEL CONNECTION DIAGRAM FOR INP-850-1 AND INP-1900-1
RF Source #2
RF Source #1
Duplex #1
or
Simplex DL #1
10 dB 100 W
Attenuation
DL output
0-50 dB
Variable
Attenuation
Simplex UL #1
DL output
DL output
DL output
Duplex #2
or
Simplex DL #2
Simplex UL #2
10 dB 100 W
Attenuation
Duplexer/Splitter
Array
UL input
RF Source #3
Duplex #3
or
Simplex DL #3
10 dB 100 W
Attenuation
0-50 dB
Variable
Attenuation
UL input
UL input
UL input
Simplex UL #3
SPECIFICATIONS
Downlink Uplink
RF FREQUENCY OPTIONS
850 MHz Band:
Bandwidth:
869-894 MHz
25 MHz
824-849 MHz
25 MHz
1900 MHz Band:
Bandwidth:
1930-1990 MHz
60 MHz
1850-1910 MHz
60 MHz
Power input (max):
PIM (@2x43 dBm):
Insertion loss Port A (min):
Insertion loss Port B and C (min):
Isolation (DL-UL):
Adjustment Range:
Adjustment Step:
Return Loss (min):
Connectors – Duplex:
Connectors (all others):
48 dBm/port
-160 dBc typical
28 dB
31 dB
85 dB
50 dB
1 dB
14 dB
DIN 7/16 female
N female
24 dB
27 dB
50 dB
1 dB
14 dB
N female
DIMENSIONS
Height x Width x Depth:5.25"x 17.25" x 21" (133.4 mm x 438 mm x 533.4 mm)
(3U) (excluding angle brackets for 19" rack mounting of chassis)
Weight:
45 lb (20 kg)
ENVIRONMENTAL
Operating Temperature:
Non-Operating Temperature:
Operating Humidity:
11-2
0 to +45° C
-20 to +85° C
5 to 95%
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
DAS Integration Panel
DAS INTEGRATION PANEL CONNECTION DIAGRAM FOR INP-8519-1
Cell
RF Source #1
Duplex #1
or
Simplex DL #1
10 dB 100 W
Attenuation
DL1 output
DL1 output
0-50 dB
Variable
Attenuation
Simplex UL #1
UL1 input
UL1 input
Duplexer/Splitter
Array
DL2 output
DL2 output
PCS
RF Source #2
Duplex #2
or
Simplex DL #2
0-50 dB
Variable
Attenuation
10 dB 100 W
Attenuation
UL2 input
UL2 input
Simplex UL #2
SPECIFICATIONS
Downlink Uplink
RF FREQUENCY OPTIONS
850 MHz Band:
Bandwidth:
869-894 MHz
25 MHz
824-849 MHz
25 MHz
1900 MHz Band:
Bandwidth:
1930-1990 MHz
60 MHz
1850-1910 MHz
60 MHz
Power input (max):
PIM (@2x43 dBm):
Insertion loss (min):
Isolation (DL-UL):
Adjustment Range:
Adjustment Step:
Return Loss (min):
Connectors – Duplex:
Connectors (all others):
48 dBm/port
-160 dBc typical
21 dB
85 dB
50 dB
1 dB
14 dB
DIN 7/16 female
N female
15 dB
50 dB
1 dB
14 dB
N female
DIMENSIONS
Height x Width x Depth:5.25"x 17.25" x 21" (133.4 mm x 438 mm x 533.4 mm)
(3U) (excluding angle brackets for 19" rack mounting of chassis)
Weight:
45 lb (20 kg)
ENVIRONMENTAL
Operating Temperature:
Non-Operating Temperature:
Operating Humidity:
11-3
0 to +45° C
-20 to +85° C
5 to 95%
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
DAS Integration Panel
DAS INTEGRATION PANEL CONNECTION DIAGRAM FOR INP-700ABC-1, INP-700UC-1, AND INP-AWS-1
MIMO 1
RF Source #1
Duplex #1
or
Simplex DL #1
10 dB 100 W
Attenuation
DL1 output
DL1 output
0-50 dB
Variable
Attenuation
Simplex UL #1
UL1 input
UL1 input
Duplexer/Splitter
Array
DL2 output
DL2 output
MIMO 2
RF Source #2
Duplex #2
or
Simplex DL #2
0-50 dB
Variable
Attenuation
10 dB 100 W
Attenuation
UL2 input
UL2 input
Simplex UL #2
SPECIFICATIONS
Downlink Uplink
RF FREQUENCY OPTIONS
700 MHz (Lower ABC) Band:
Bandwidth:
728-746 MHz
18 MHz
698-716 MHz
18 MHz
700 MHz (Upper C) Band:
Bandwidth:
746-757 MHz
11 MHz
776-787 MHz
11 MHz
AWS Band:
Bandwidth:
2110-2155 MHz
45 MHz
1710-1755 MHz
45 MHz
Power input (max):
PIM (@2x43 dBm):
Insertion loss (min):
Isolation (DL-UL):
Adjustment Range:
Adjustment Step:
Return Loss (min):
Connectors – Duplex:
Connectors (all others):
48 dBm/port
-160 dBc typical
21 dB
85 dB
50 dB
1 dB
14 dB
DIN 7/16 female
N female
15 dB
50 dB
1 dB
14 dB
N female
DIMENSIONS
Height x Width x Depth:5.25"x 17.25" x 21" (133.4 mm x 438 mm x 533.4 mm)
(3U) (excluding angle brackets for 19" rack mounting of chassis)
Weight:
45 lb (20 kg)
ENVIRONMENTAL
Operating Temperature:
Non-Operating Temperature:
Operating Humidity:
11-4
0 to +45° C
-20 to +85° C
5 to 95%
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
FlexWave Active Integration Panel (AIP)
The Active DAS Integration Panel provides a structured component interface between the RF source and DAS host units. A
single Active DAS Integration Panel supports up to 8 base station TX/RX inputs. The Active DAS Integration Panel contains
all required RF components, thus reducing installation complexity and labor costs. The Active DAS Integration Panel is
compatible with Fusion, Spectrum and Flexwave Prism products.
PRODUCT HIGHLIGHTS
• Supports up to 8 base station TX/RX Inputs
• Input Range 0.25W to 100W
• Remote control and monitoring via web
• Monitors UL & DL power levels
• Supports ALC in DL path with user configured
alarm threshold and automatic attenuation
• Combiner/Splitter tray can be field re-configured
• Diagnostic tone for commissioning,
self-mapping & troubleshooting
• CW tone tunable across the passband
• Supports IPv4 and IPv6
• Ability to address up to 32 chassis with one IP address
• Meets NEBS carrier grade level 1 Requirements
RF PERFORMANCE SPECIFICATIONS
The RF modules are band specific, plug-in and hot-swappable
Frequency and bands supported:
E-UTRA Band/Other
Band 5 (850 Cell)
Uplink (RX) Frequency (MHz)
869-894
824-849
Band 25 (1900 PCS)
1930-1995
1850-1915
Band 4 (2100 AWS)
2110-2155
1710-1755
Band 12 (700 ABC)
728-746
698-716
Band 13 (700 UC)
746-757
776-787
iDEN800
851-869
806-824
iDEN900
935-941
896-902
Passband Ripple (TX and RX): PIM performance: Input power range: Overpower protection: Downlink Gain range: Power balancing:
Uplink Gain Range: Input Return loss: Output Return loss: 11-5
Downlink (TX) Frequency (MHz)
<2dB over temperature range
-160dBc @ 2X43dBm (-117dBm @ 2X43dBm)
0.25 to 100Watts RMS composite power
DAS interrupts RF path for input power >100Watts over 5 seconds
-75 to -5dB
Supports user settable downlink ALC thresholds for power balancing
neutral host arrangements
-30 to 0dB
18dB
14dB
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Active DAS Integration Panel (AIP)
SOFTWARE SPECIFICATIONS
• Controls and monitors up to 32 cascaded AIPs
• Cascading allows for the use of one IP address with a single connection to the NOC
• AIP software is not integrated with the DAS software for integrated system management
• Supports IPv4 and IPv6
• Supports remote software updates
• Provides remote downlink and uplink gain control
• Monitors uplink and downlink power levels
• Provides user settable thresholds for under and over power alarms
COMBINER SPLITTER UNIT’S (CSUs) COMBINE AND SIMULCAST SPLIT CONFIGURATIONS
• Houses passive power dividers for combining up to four band specific
RF modules and splitting up to four different zones
• Four standard configurations offered
• Plug-in design supports reconfiguration of the CSU in the field.
• RF power detectors located at the CSU’s output and diagnostic tones in the
RF modules aid in trouble shooting, and commissioning
ORDERING INFORMATION
Description
Part Number
Chassis
AIP-HU-1
Control module
AIP-CU-1
Split/Comb Tray Config1
AIP-CSU-1
Split/Comb Tray Config2
AIP-CSU-2
Split/Comb Tray Config3
AIP-CSU-3
Split/Comb Tray Config4
AIP-CSU-4
700ABC RF Module
AIP-BIU700ABC-1
700UC RF Module
AIP-BIU700UC-1
800 MHz RF Module
AIP-BIU800-1
850MHz RF Module
AIP-BIU850-1
1900MHz RF Module
AIP-BIU1900-1
2100MHz RF Module
AIP-BIUAWS-1
11-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
The MiniDSX Multifunction panel is used in environments where multiple transmission rates and media need to be
connected. This includes: voice circuits, alarm connections, DSX1, DSX3, Cat 5e, Cat 6, and Cat 6a. The flexibility to
connect various types of media in one panel simplifies equipment connections and provides a convenient test access
point as well as a convenient location for rearranging and restoring circuits.
Empty Multifunction Chassis
ORDERING INFORMATION
Product Description
Part Number
Empty Multifunction Chassis
Holds 3 modules, HxW: 1.75" x 19"/23"
MDP-CH
MDP-CH
DS1, DS3 and Category 5e Modules
ORDERING INFORMATION
Product Description
Part Number
DS1 Module
Front 3-port bantam jacks; rear cross-connect wire-wrap
DS-1 MDP-H
DS-1 MDP-H
DS3 Modules
Front 3-port midsize jacks; rear cross-connect BNC
DS-3 MDP-RAHM
All front access 3-port midsize jacks; cross-connect BNC
DS-3 MDP-FAM
Category 5e RJ Modules
16-Port; front RJ45, rear RJ45
C5-MDP-RJRJ-16
16-Port; front RJ45, rear LSA-PLUS IDC
C5-MDP-RJIL-16
DS-3 MDP-RAHM
DS-3 MDP-FAM
C5-MDP-RJRJ-16 or
C5-MDP-RJIL-16
11-7
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Fiber Connector/Adapter Cleaning Kit
The fiber connector/adapter cleaning kit contains all the items required to
adequately clean fiber connectors and adapters. The performance of an optical
fiber system is largely dependent on the fiber connector cleaning procedures
followed prior to installation. It is suggested that all the connectors and adapters
be cleaned before making any connections. The kit cleans approximately 500
connectors or adapters.
ORDERING INFORMATION
Description
Part Number
Fiber Connector/Adapter Cleaning Kit (wet cleaning method)
Includes:
• Instruction sheet
• Lint-free wipes
• Isopropyl alcohol
• Cotton swabs
• Lint-free pipe cleaners
• Oil-free compressed air
FPC-CLNKIT
Includes FPC-CLNKIT plus the dry wipe cleaning cassette and refill
Dry Wipe Cleaning Cassette and Refill
FPC-CLNKIT1
FPC-CLNKIT2
This kit contains flammable alcohol and compressed air. For this reason, it can be shipped by
surface method only
11-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Fiber Inspection Kit
ORDERING INFORMATION
Product Description
Image
Quantity
Part Number
Optical Fiber Inspection and Cleaning Kit for Standard Connector Styles (LC, SC, ST, FC), MT-RJ,
and MPO.
Kit includes everything needed to perform routine fiber maintenance and troubleshooting including cleaning tools, an inspection microscope, a visual fault locator, and a CD-ROM with
detailed inspection, cleaning instructions and a rugged carrying case. Kit components:
A
1
2064651-1
Visual Fault Locator (VFL)) with 1.25 MM Adapter
B
1
1828352-2
200x Microscope with 2.5 mm Adapter
C
1
1754767-1
1.25 mm (LC) Microscope Adapter
D
1
1754765-1
MT-RJ Microscope Adapter
E
1
1754768-1
MPOA Microscope Adapter
F
1
1828837-1
MPO Microscope Adapter
G
1
1828836-1
Termination Training, CD-ROM
H
1
2064710-1
2.5 mm Stick Cleaners (10/package)
I
5
1918807-1
1.25 mm Stick Cleaners (10/package)
J
5
1918808-1
One Slot Reel Cleaner
K
1
1918803-1
MT-RJ w/pins Reel Cleaner
L
1
1918804-1
SC in Bulkhead Cleaner (IBC)
M
1
2064499-1
LC IBC
N
1
2064500-1
MPO IBC
O
1
1918809-1
Premium Hard Case
P
1
TBD
11-9
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
NEOCLEAN Stick Cleaner
FEATURES
• Dry cloth stick cleaners utilize a densely woven micro-fiber cloth to clean fiber
optic connector tips while reducing static charge
• Perforated handle for customizing length and angle
• Overall stick length: 151 mm (5.94")
• 250 Sticks per package
ORDERING INFORMATION
Description
Part Number
Stick Cleaner - 2.5 mm Tip Diameter
1918807-1
Stick Cleaner - 1.25 mm Tip Diameter
1918808-1
LC and SC Connector Cleaner (In Bulkhead Cleaner)
Figure A
FEATURES
• Dry cloth cleaners specially designed to clean single fiber
connectors in adapters, bulkheads, and faceplates
• Dust cap of the cleaner acts as an adapter for cleaning unmated connectors
• Extended tip reaches recessed connectors
• Removes dust and oil contamination
• Disposable cleaner with 525+ cleanings per unit
ORDERING INFORMATION
Description
Figure
Part Number
LC Connector Cleaner (In Bulkhead Cleaner)
A
2064500-1
SC Connector Cleaner (In Bulkhead Cleaner)
B
2064499-1
11-10
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Figure B
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Protective Tubing Cutting Tool
The protective tubing cutting tool is used to score the protective tubing so the
tubing can be cut to the appropriate lengths for the final installation.
ORDERING INFORMATION
Product Description
Part Number
Protective tubing cutting tool
BLK-BK0TUB
Grounding Kit
Set Screws
Cable Assembly Lug
Kit used to ground armored fiber cable.
10-24 Screw
ORDERING INFORMATION
Product Description
Grounding kit for;
Armored OSP cable
Includes:
One cable assembly lug type ground kit
One #6 ground cable 229 mm (9") long
ny armored loose tube or buffer tubed fiber
A
OSP cable
Includes:
One bullet ground connector
One #6 ground cable 127 mm (5") long
F
rame mount configuration
Any armored loose tube or buffer tubed OSP cable
Includes:
One bullet ground connector
One #6 ground cable 305 mm (12") long
Grounding Kit
(GAK-FEC001 Shown)
Part Number
GAK-FEC001
2 Securing Nuts
Top
GND-STPKIT
Base
Bullet Ground
Connector
FEC-ACCGND02
#6 Ground Cable
Grounding Kit
(GND-STPKIT Shown)
Grounding/Moisture Blocking Kits
Kit used to properly block gel filled stranded and ribbon cables.
ORDERING INFORMATION
Product Description
Part Number
Grounding/Moisture blocking kit;
Includes components for grounding and blocking gel filled fiber
cables: blocking gel, heat shrink and grounding accessories
FBK-0SP002
Moisture blocking kit;
Includes components for blocking gel filled
fiber cables: syringe, blocking gel
11-11
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Velcro Cable Ties
FEATURES
Figure A
For 8-inch and 12-inch ties, an order quantity of one equals one roll of ten ties.
ORDERING INFORMATION
Figure B
Part Number
Description
Figure
1" x 8"
A
Black
Blue
1375253-2
–
1" x 12"
B
1375254-2
–
5/8" x 5 yards
C
1375255-2
1375255-6
1375256-2
–
1" x 12" Flame Retardant*
* NOTE: Complies with NEC 300-22(c) and (d) for use in environmental air handling spaces.
Available in black only.
Figure C
AMP-TY Nylon Cable Ties
ORDERING INFORMATION
Dimensions (Approximate)
Length
Width
Thickness
Minimum Tensile
Strength
Maximum Bundle
Diameter
Package
Quantity
Part Number
Natural
Black
2-604771-9
2-604771-0
4" (103.0 mm)
0.096"
(2.44 mm)
0.037"
(0.94 mm)
18 lbs
(80.1 N)
0.75"
(19.10 mm)
1000
100
1-604771-9
1-604771-0
6" (155.0 mm)
0.140"
(3.56 mm)
0.045"
(1.14 mm)
30 lbs
(133.5 N)
1.25"
(31.75 mm)
1000
2-603227-9
2-603227-0
100
1-603227-9
1-603227-0
8" (204.0 mm)
0.184"
(4.67 mm)
0.047"
(1.19 mm)
50 lbs (222.5 N)
1.75"
(44.45 mm)
1000
2-604772-9
2-604772-0
100
1-604772-9
1-604772-0
12" (300.0 mm)
0.183"
(4.65 mm)
0.051"
(1.30 mm)
50 lbs (222.5 N)
3.00"
(76.20 mm)
1000
2-604751-9
2-604751-0
100
1-604751-9
1-604751-0
Grounding Lug Kit
FEATURES
• Use for grounding panels to locations other than rack
• Accommodates a maximum wire size of 6 AWG
ORDERING INFORMATION
Description
Part Number
Grounding Lug Kit
556438-1
11-12
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Vertical Cable guide kit
The Vertical Cable Guide is a simple
method to use to manage either fiber,
or coaxial cables entering and exiting
from the front of equipment housed
in a vertical rack. The kit contains
2-3” vertical cable guides and 4 edge
protectors.
ORDERING INFORMATION
Description
Vertical Cable Guide Kit
Part Number
VCG-31CS
Adapters
SIMPLEX AND DUPLEX ADAPTERS
Bulkhead adapters are available for all standard connector types in both
singlemode and multimode. The adapters are color coded allowing easy
identification of the adapter type.
The adapter sleeve aligns the ferrules and holds them in place. All singlemode and
multimode adapters include zirconia alignment sleeves. Zirconia sleeves provide
tight tolerances, generally required for angled physical contact (APC) connectors,
but also excellent for ultra physical contact (UPC) and multimode connectors.
LC small-form-factor adapters are available as duplex, enabling two connectors to
be used in the same footprint as the SC connector.
Adapters
Description
Part Number*
Simplex adapters
Singlemode SC
FBA-SC
Singlemode SC - no flange
FBA-SCNF
Singlemode FC - round adapter
FBA-FR
Multimode SC
FBA-MSC
Multimode SC- no flange
FBA-MSCNF
Singlemode LC
FBA-LC-Z-NF
Singlemode LC - angled polish, no flange
FBA-ALCZNF
Singlemode SC - angled polish
FBA-ASCZ
Duplex adapters
Singlemode SC
FBA-DSCNF
Multimode SC
FBA-DMSCNF
Singlemode LC – no flange
FBA-DLC-Z-NF
Multimode LC
FBA-DMLCNF
Singlemode SC - angled polish
FBA-DASCZNF
Singlemode LC - angled polish
FBA-ALCZ
11-13
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
Connectivity Solutions for Distributed Antenna Systems
Miscellaneous
Attenuators
IN-LINE ATTENUATORS
A fiber optic attenuator is an optical device that induces a calibrated
fixed loss between two connectors, which dampens, or attenuates the
fiber optic signal. Attenuation is required if an optical signal has too
much power, exceeding the operating range of the equipment, which
causes saturation at the receiver and induces system errors or failures.
In-Line FC Attenuator
Adapter
ORDERING INFORMATION
Description
Part Number*
In-Line
Attenuator
Attenuation
05 dB
FOA-INLC05
10 dB
FOA-INLC010
15 dB
FOA-INLC015
20 dB
FOA-INLC020
05 dB
FOA-INSC05
10 dB
FOA-INSC10
15 dB
FOA-INSC15
20 dB
FOA-INSC20
±0.75 dB
>5 dB
±10%
SC angled polish
05 dB
FOA-INASC05
10 dB
FOA-INASC10
15 dB
FOA-INASC15
20 dB
FOA-INASC20
*O
ther attenuation values and connector styles are available upon request. Please contact TE
Technical Assistance Center.
11-14
Tolerance
≤5 dB
SC ultra polish
Connector/
Patch Cord
LC ultra polish
In-Line SC Attenuator
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
Part Number
1-603227-0.........................................................11-12
1-603227-9.........................................................11-12
1-604751-0..........................................................11-12
1-604751-9..........................................................11-12
1-604771-0..........................................................11-12
1-604771-9..........................................................11-12
1-604772-0.........................................................11-12
1-604772-9.........................................................11-12
1-1499150-0.......................................................... 9-1
1-1499150-2.......................................................... 9-1
1-1499150-5.......................................................... 9-1
1-1933116-0............................................................ 9-1
1-1933116-2............................................................ 9-1
1-1933116-4............................................................ 9-1
1-1933116-5............................................................ 9-1
1-1933116-6............................................................ 9-1
1-1933117-0............................................................ 9-1
1-1933117-2............................................................. 9-1
1-1933117-4............................................................ 9-1
1-1933117-5............................................................. 9-1
1-1933117-6............................................................ 9-1
1-1933118-0............................................................ 9-1
1-1933118-2............................................................ 9-1
1-1933118-4............................................................ 9-1
1-1933118-5............................................................ 9-1
1-1933118-6............................................................ 9-1
1-1933119-0............................................................ 9-1
1-1933119-2............................................................ 9-1
1-1933119-4............................................................ 9-1
1-1933119-5............................................................ 9-1
1-1933119-6............................................................ 9-1
1-1933120-0.......................................................... 9-1
1-1933120-2........................................................... 9-1
1-1933120-4........................................................... 9-1
1-1933120-5........................................................... 9-1
1-1933120-6........................................................... 9-1
1-1933121-0............................................................ 9-1
1-1933121-2............................................................. 9-1
1-1933121-4............................................................ 9-1
1-1933121-5............................................................ 9-1
1-1933121-6............................................................ 9-1
1-1933122-0........................................................... 9-1
1-1933122-2........................................................... 9-1
1-1933122-4........................................................... 9-1
1-1933122-5........................................................... 9-1
1-1933122-6........................................................... 9-1
1-1933123-0........................................................... 9-1
1-1933123-2........................................................... 9-1
1-1933123-4........................................................... 9-1
1-1933123-5........................................................... 9-1
1-1933123-6........................................................... 9-1
12-1
1-1933124-0........................................................... 9-1
1-1933124-2........................................................... 9-1
1-1933124-4........................................................... 9-1
1-1933124-5........................................................... 9-1
1-1933124-6........................................................... 9-1
1F6818-000.........................................................4-5
2-336513-1............................................................9-5
2-336513-2..........................................................9-5
2-336513-3..........................................................9-5
2-336513-4..........................................................9-5
2-336513-5..........................................................9-5
2-336513-6..........................................................9-5
2-336513-7...........................................................9-5
2-336513-8..........................................................9-5
2-336513-9..........................................................9-5
2-603227-0........................................................11-12
2-603227-9........................................................11-12
2-604751-0.........................................................11-12
2-604751-9.........................................................11-12
2-604771-0........................................................11-12
2-604771-9.........................................................11-12
2-604772-0.......................................................11-12
2-604772-9........................................................11-12
2-737893-1...........................................................9-5
2-737893-2..........................................................9-5
2-737893-3..........................................................9-5
2-737893-4.........................................................9-5
2-737893-5..........................................................9-5
2-737893-6.........................................................9-5
2-737893-7..........................................................9-5
2-1499150-5......................................................... 9-1
2-1933116-0........................................................... 9-1
2-1933116-5........................................................... 9-1
2-1933117-0........................................................... 9-1
2-1933117-5........................................................... 9-1
2-1933118-0........................................................... 9-1
2-1933118-5........................................................... 9-1
2-1933119-0........................................................... 9-1
2-1933119-5........................................................... 9-1
2-1933120-0......................................................... 9-1
2-1933120-5.......................................................... 9-1
2-1933121-0........................................................... 9-1
2-1933121-5........................................................... 9-1
2-1933122-0.......................................................... 9-1
2-1933122-5.......................................................... 9-1
2-1933123-0.......................................................... 9-1
2-1933123-5.......................................................... 9-1
2-1933124-0......................................................... 9-1
2-1933124-5.......................................................... 9-1
3-1933116-0........................................................... 9-1
3-1933117-0........................................................... 9-1
3-1933118-0........................................................... 9-1
3-1933119-0........................................................... 9-1
3-1933120-0......................................................... 9-1
3-1933121-0........................................................... 9-1
3-1933122-0.......................................................... 9-1
3-1933123-0.......................................................... 9-1
3-1933124-0......................................................... 9-1
4-1933116-0.......................................................... 9-1
4-1933117-0........................................................... 9-1
4-1933118-0.......................................................... 9-1
4-1933119-0.......................................................... 9-1
4-1933120-0......................................................... 9-1
4-1933121-0........................................................... 9-1
4-1933122-0......................................................... 9-1
4-1933123-0......................................................... 9-1
4-1933124-0......................................................... 9-1
5-1375202-3........................................................9-5
5-1375202-4........................................................9-5
5-1375204-3........................................................9-5
5-1375204-4.......................................................9-5
5-1479184-3.........................................................9-5
5-1479184-4........................................................9-5
5-1479185-3.........................................................9-5
5-1479185-4.........................................................9-5
5-1933116-0........................................................... 9-1
5-1933117-0........................................................... 9-1
5-1933118-0........................................................... 9-1
5-1933119-0........................................................... 9-1
5-1933120-0......................................................... 9-1
5-1933121-0........................................................... 9-1
5-1933122-0.......................................................... 9-1
5-1933123-0.......................................................... 9-1
5-1933124-0......................................................... 9-1
9-336513-1...........................................................9-5
9-336513-2..........................................................9-5
9-336513-3..........................................................9-5
9-336513-4..........................................................9-5
9-336513-5..........................................................9-5
9-336513-6..........................................................9-5
9-336513-7..........................................................9-5
9-336513-8..........................................................9-5
9-336513-9..........................................................9-5
9-737893-1...........................................................9-5
9-737893-2.........................................................9-5
9-737893-3.........................................................9-5
9-737893-4.........................................................9-5
9-737893-5.........................................................9-5
9-737893-6.........................................................9-5
9-737893-7..........................................................9-5
40606V-000.....................................................4-5
41606V-000.......................................................4-5
056395-000...................................................... 4-7
57581K-000........................................................4-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
Part Number (Continued)
88823Y-00..........................................................4-8
089279-000...................................................... 4-7
92733M-000...................................................... 4-7
118317-000...........................................................4-6
143339-000..............................................4-6, 4-8
219560-1................................................................9-4
219560-2..............................................................9-4
219560-3..............................................................9-4
219560-4..............................................................9-4
219560-5..............................................................9-4
219560-6..............................................................9-4
219560-7...............................................................9-4
219560-8..............................................................9-4
219567-1................................................................9-4
219567-2...............................................................9-4
219567-3...............................................................9-4
219567-4...............................................................9-4
219567-5...............................................................9-4
219567-6...............................................................9-4
219567-7...............................................................9-4
219567-8...............................................................9-4
226809-000......................................................4-6
234855-000.......................................................4-6
381107-000.........................................................4-5
406042-1............................................................ 10-7
429631-000........................................................4-5
449105-000....................................................... 4-7
457507-000....................................................... 4-7
460490-000.....................................................4-6
469031-000.......................................................4-6
526767-000.......................................................4-6
556438-1..............................................................11-12
556965-1............................................................. 10-2
556965-2........................................................... 10-2
556965-3........................................................... 10-2
556965-4........................................................... 10-2
556965-5........................................................... 10-2
557548-1............................................................. 10-7
558266-1............................................................. 10-2
558267-1............................................................. 10-2
558268-1............................................................. 10-2
558269-1............................................................. 10-2
558301-1.............................................................. 10-7
558329-1.............................................................10-6
558331-1..............................................................10-6
558850-000......................................................4-5
559369-1............................................................. 10-7
559370-1............................................................. 10-7
577809-000.......................................................4-6
646311-000.........................................................4-6
659136-000........................................................4-5
12-2
671575-000........................................................ 4-7
693979-000.............................................4-6, 4-8
829333-000.......................................................4-6
888498-000............................................4-6, 4-8
1375013-2.............................................................9-2
1375014-2.............................................................9-2
1375015-2.............................................................9-2
1375016-2.............................................................9-2
1375158-1............................................................. 10-5
1375158-2............................................................ 10-5
1375159-1............................................................. 10-5
1375159-2............................................................ 10-5
1375160-1............................................................. 10-5
1375160-2........................................................... 10-5
1375161-1.............................................................. 10-5
1375161-2............................................................. 10-5
1375162................................................................ 10-5
1375162-1............................................................. 10-5
1375162-2............................................................ 10-5
1375163-1............................................................. 10-5
1375163-2............................................................ 10-5
1375164-1............................................................. 10-5
1375165-1............................................................. 10-5
1375166-1............................................................. 10-5
1375167-1............................................................. 10-5
1375253-2............................................................11-12
1375254-2...........................................................11-12
1375255-2............................................................11-12
1375255-6............................................................11-12
1375256-2............................................................11-12
1375257-1............................................................ 10-5
1375258-1............................................................ 10-5
1375259-1............................................................ 10-5
1375260-1........................................................... 10-5
1479222-1............................................................ 10-5
1479222-2.......................................................... 10-5
1479223-1............................................................ 10-5
1479224-1............................................................ 10-5
1479225-1............................................................ 10-5
1479225-2.......................................................... 10-5
1479402-1...........................................................10-6
1479582-1............................................................10-6
1479732-1............................................................10-6
1479733-1............................................................10-6
1479860-1........................................................... 10-7
1479992-1........................................................... 10-2
1479992-2.......................................................... 10-2
1499033-1.............................................................9-4
1499033-2...........................................................9-4
1499033-3...........................................................9-4
1499033-4...........................................................9-4
1499033-5...........................................................9-4
1499033-6...........................................................9-4
1499033-7............................................................9-4
1499033-8...........................................................9-4
1499038-1.............................................................9-4
1499038-2...........................................................9-4
1499038-3...........................................................9-4
1499038-4...........................................................9-4
1499038-5...........................................................9-4
1499038-6...........................................................9-4
1499038-7...........................................................9-4
1499038-8...........................................................9-4
1499150-3............................................................. 9-1
1499150-5............................................................. 9-1
1499150-7.............................................................. 9-1
1499600-2...........................................................9-2
1499601-2............................................................9-2
1754765-1..............................................................11-9
1754767-1..............................................................11-9
1754768-1..............................................................11-9
1828352-2............................................................11-9
1828836-1.............................................................11-9
1828837-1..............................................................11-9
1918803-1..............................................................11-9
1918804-1..............................................................11-9
1918807-1.................................................. 11-9, 11-10
1918808-1.................................................. 11-9, 11-10
1918809-1..............................................................11-9
1933047-1.............................................................9-3
1933047-2............................................................9-3
1933047-3............................................................9-3
1933047-4...........................................................9-3
1933047-5............................................................9-3
1933047-6............................................................9-3
1933047-7............................................................9-3
1933047-8............................................................9-3
1933116-2............................................................... 9-1
1933116-3............................................................... 9-1
1933116-4............................................................... 9-1
1933116-5............................................................... 9-1
1933116-6............................................................... 9-1
1933116-7................................................................ 9-1
1933116-8............................................................... 9-1
1933116-9............................................................... 9-1
1933117-2................................................................ 9-1
1933117-3................................................................ 9-1
1933117-4................................................................ 9-1
1933117-5................................................................ 9-1
1933117-6................................................................ 9-1
1933117-7................................................................ 9-1
1933117-8................................................................ 9-1
1933117-9................................................................ 9-1
1933118-2................................................................ 9-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
1933118-3............................................................... 9-1
1933118-4............................................................... 9-1
1933118-5............................................................... 9-1
1933118-6............................................................... 9-1
1933118-7................................................................ 9-1
1933118-8............................................................... 9-1
1933118-9............................................................... 9-1
1933119-2............................................................... 9-1
1933119-3............................................................... 9-1
1933119-4............................................................... 9-1
1933119-5............................................................... 9-1
1933119-6............................................................... 9-1
1933119-7................................................................ 9-1
1933119-8............................................................... 9-1
1933119-9............................................................... 9-1
1933120-2.............................................................. 9-1
1933120-3.............................................................. 9-1
1933120-4.............................................................. 9-1
1933120-5.............................................................. 9-1
1933120-6.............................................................. 9-1
1933120-7.............................................................. 9-1
1933120-8.............................................................. 9-1
1933120-9.............................................................. 9-1
1933121-2................................................................ 9-1
1933121-3................................................................ 9-1
1933121-4............................................................... 9-1
1933121-5................................................................ 9-1
1933121-6............................................................... 9-1
1933121-7................................................................ 9-1
1933121-8................................................................ 9-1
1933121-9............................................................... 9-1
1933122-2............................................................... 9-1
1933122-3.............................................................. 9-1
1933122-4.............................................................. 9-1
1933122-5.............................................................. 9-1
1933122-6.............................................................. 9-1
1933122-7............................................................... 9-1
1933122-8.............................................................. 9-1
1933122-9.............................................................. 9-1
1933123-2.............................................................. 9-1
1933123-3.............................................................. 9-1
1933123-4.............................................................. 9-1
1933123-5.............................................................. 9-1
1933123-6.............................................................. 9-1
1933123-7............................................................... 9-1
1933123-8.............................................................. 9-1
1933123-9.............................................................. 9-1
1933124-2.............................................................. 9-1
1933124-3.............................................................. 9-1
1933124-4.............................................................. 9-1
1933124-5.............................................................. 9-1
1933124-6.............................................................. 9-1
12-3
1933124-7............................................................... 9-1
1933124-8.............................................................. 9-1
1933124-9.............................................................. 9-1
1933352...............................................................10-8
1933352-1............................................................10-8
1933352-2..........................................................10-8
1933352-3..........................................................10-8
1933352-4..........................................................10-8
1933425-1........................................................... 10-7
1933458-1.............................................................9-2
1933530-1........................................................... 10-3
1933531-1............................................................. 10-3
1933532-1............................................................ 10-3
1933533-1........................................................... 10-3
1933534-1........................................................... 10-3
1933535-1............................................................ 10-3
1933536-1........................................................... 10-3
1933540.............................................................. 10-3
1933540-1........................................................... 10-3
1933541-1............................................................. 10-3
1933542-1........................................................... 10-3
1933552-1............................................................10-4
1933553-1...........................................................10-4
1933554-1...........................................................10-4
1933555-1...........................................................10-4
1933556-1...........................................................10-4
1933557-1............................................................10-4
1933558-1...........................................................10-4
1933559-1............................................................ 10-1
1933560-1............................................................ 10-1
1933561-1............................................................. 10-3
1933562-1........................................................... 10-3
1933566-1........................................................... 10-3
1933567-1............................................................ 10-3
1933570-1............................................................ 10-1
1933658-1.............................................................9-2
2064499-1............................................... 11-9, 11-10
2064500-1............................................... 11-9, 11-10
2064651-1.............................................................11-9
2064710-1.............................................................11-9
2111279-1.............................................................. 10-2
A
A05721-000.......................................................4-5
A11796-000........................................................ 4-7
A33560-000..................................................... 4-7
A38215-000.......................................................4-5
A51343-000.......................................................4-5
A91433-000....................................................... 4-7
AIP...........................................................................11-6
AIP-BIU700ABC-1...........................................11-6
AIP-BIU700UC-1..............................................11-6
AIP-BIU800-1.....................................................11-6
AIP-BIU850-1.....................................................11-6
AIP-BIU1900-1...................................................11-6
AIP-BIUAWS-1...................................................11-6
AIP-CSU-1............................................................11-6
AIP-CSU-2...........................................................11-6
AIP-CSU-3...........................................................11-6
AIP-CSU-4...........................................................11-6
AIP-CU-1...............................................................11-6
AIP-HU-1...............................................................11-6
B
Blank Panels..................................................... 10-2
BLK-BK0TUB.....................................................11-11
BLK-MSTRKIT....................................................11-11
C
C5-MDP-RJIL-16............................................... 11-7
C5-MDP-RJRJ-16............................................. 11-7
C61629-000.......................................................4-5
C67369-000......................................................4-5
CL-01M..................................................................8-4
CL-01M0...............................................................8-4
CL-02M....................................................... 8-2, 8-4
CL-02M0..............................................................8-4
CL-03M0..............................................................8-4
CL-04M.................................................................8-2
CL-04M0..............................................................8-4
CL-06M.................................................................8-2
CL-14M...................................................................8-2
CL-250M..............................................................8-4
CL-300M..............................................................8-4
CL-350M..............................................................8-4
CMB-P-19.............................................................8-2
CMB-P-23............................................................8-2
CWVMW-2KKAA0DN2000...................... 7-8
D
D20592-000......................................................4-5
D25359-000......................................................4-5
D46439-000..................................................... 4-7
DCK-02.................................................................8-2
DS-1 MDP-H........................................................ 11-7
DS-3 MDP-FAM................................................ 11-7
DS-3 MDP-RAHM............................................ 11-7
E
E14672-000........................................................ 4-7
E21473-000........................................................4-5
Equipment Racks........................................... 10-1
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
F
F-1............................................................................8-3
F-1 1/2.....................................................................8-3
F-1 1/3.....................................................................8-3
F-1/2........................................................................8-3
F-1/4........................................................................8-3
F-2...........................................................................8-3
F-2 1/2....................................................................8-3
F-2/10....................................................................8-3
F-3...........................................................................8-3
F-3 1/2....................................................................8-3
F-3/4......................................................................8-3
F-3/8......................................................................8-3
F-4...........................................................................8-3
F-5...........................................................................8-3
F-7 1/2....................................................................8-3
F-12..........................................................................8-3
F-15..........................................................................8-3
F-20........................................................................8-3
F2103R-000.......................................................4-6
F53958-000...................................................... 4-7
F67166-000........................................................4-5
FBA-ALCZ......................................................... 11-13
FBA-ALCZNF.................................................. 11-13
FBA-ASCZ......................................................... 11-13
FBA-DALC-Z.................................................... 11-13
FBA-DASCZNF............................................... 11-13
FBA-DLCNF..................................................... 11-13
FBA-DLC-Z-NF............................................... 11-13
FBA-DMLCNF................................................. 11-13
FBA-DMSCNF................................................. 11-13
FBA-DSCNF..................................................... 11-13
FBA-FR............................................................... 11-13
FBA-LCZ............................................................ 11-13
FBA-LC-Z-NF.................................................. 11-13
FBA-MSC........................................................... 11-13
FBA-MSCNF..................................................... 11-13
FBA-SC............................................................... 11-13
FBA-SCNF........................................................ 11-13
FBK-0SP002......................................................11-11
FEC-144............................................................. 3-24
FEC-288............................................................ 3-24
FEC-ACCGND0............................................. 3-25
FEC-ACCGND02..............................................11-11
FFB-BTM-PLT-KIT...........................................3-9
FFB-F0000S00S00000............................3-8
FFB-F012EMS7FSDDUx..............................3-6
FFB-F012EMS7SSDDUx..............................3-6
FFB-F012EMSKFSDDUx..............................3-6
FFB-F012EMSKSSDDUx..............................3-6
FFB-F012KCSK0SA00x...............................3-6
FFB-F012UMS7SSDDUx..............................3-6
12-4
FFB-F012UMSKSSDDUx.............................3-6
FFB-F024EMS7FSDDUx.............................3-6
FFB-F024EMS7SSDDUx.............................3-6
FFB-F024EMSKFSDDUx............................3-6
FFB-F024EMSKSSDDUx............................3-6
FFB-F024KCSK0SA00x.............................3-6
FFB-F024UMS7SSDDUx.............................3-6
FFB-F024UMSKSSDDUx............................3-6
FFB-F0127CS70SA00x................................3-6
FFB-F0247CS70SA00x..............................3-6
FFB-F01200H7SSDDUD.............................3-6
FFB-F01200HKSSDDUD.............................3-6
FFB-F01222S7SSDDUx................................3-6
FFB-F01222SKSSDDUx...............................3-6
FFB-F01222SOVS0000...............................3-6
FFB-F02400H7SSDDUD............................3-6
FFB-F02400HKSSDDUD...........................3-6
FFB-F02422S7SSDDUx...............................3-6
FFB-F02422SKSSDDUx..............................3-6
FFB-F02422SOVS0000.............................3-6
FFB-FD000000J000..................................3-8
FFB-FD000000K000.................................3-8
FFB-FD000000M000.................................3-8
FFB-FD000000U000.................................3-8
FFB-FD000000V000.................................3-8
FFB-FD000000W000................................3-8
FFB-FD012J0AC000.................................... 3-7
FFB-FD012JMDF000.................................... 3-7
FFB-FD012JMDS000.................................... 3-7
FFB-FD012TMF000....................................... 3-7
FFB-FD012TMFS000.................................... 3-7
FFB-FD024CMF000..................................... 3-7
FFB-FD024CMFS000.................................. 3-7
FFB-FD024K0AC000.................................. 3-7
FFB-FD024KMDF000................................. 3-7
FFB-FD024KMDS000.................................. 3-7
FFB-FD0000002000..................................3-8
FFB-R0000S00S00000............................3-8
FFB-R012ES22SDUXXX..............................3-4
FFB-R012ESJSSDUXXX..............................3-4
FFB-R024ES22SDUXXX.............................3-4
FFB-R024ESJSSDUXXX.............................3-4
FFB-R024ESKSSDUXXX............................3-4
FFB-R0120S22SDUXXX..............................3-4
FFB-R0240S22SDUXXX.............................3-4
FFB-RD012JMDSXXX................................... 3-7
FFB-RD012KMDSXXX................................... 3-7
FFB-RD024JMDSXXX.................................. 3-7
FFB-RD024KMDSXXX................................. 3-7
FFB-RD0120MD2XXX................................... 3-7
FFB-RD0240MD2XXX................................. 3-7
FGSB-KT03-C...................................................6-2
FGSB-KT03-C-10F..........................................6-2
FGSB-KT03-C-15F..........................................6-2
FGSB-MEX1-C-5F............................................6-2
FGSB-MEX1-C-10F..........................................6-2
FGSB-MEX1-C-15F...........................................6-2
FGS-HASK-C....................................................... 6-1
FGS-HLDR-5/8.................................................. 6-1
FGS-HMEC-C...................................................... 6-1
FGS-HNTR-5/8-A............................................. 6-1
FGS-HSHC-10....................................................6-2
FGS-HTR2-2-5/8.............................................. 6-1
FGS-KDH2-C....................................................... 6-1
FGS-KT03-C......................................................6-2
FGS-KT03-C-10F.............................................6-2
FGS-KT03-C-15F..............................................6-2
FGS-KTW1-JA...................................................6-3
FGS-KTW1-JN...................................................6-3
FGS-KTW2-J......................................................6-3
FGS-KTW2-JN..................................................6-3
FGS-KTW2-K.....................................................6-3
FGS-KTW2-R.....................................................6-3
FGS-KTW2-RN.................................................6-3
FGS-KTW2-T......................................................6-3
FGS-KTW2-TN..................................................6-3
FGS-MEX1-C-5F...............................................6-2
FGS-MEX1-C-10F..............................................6-2
FGS-MEX1-C-15F..............................................6-2
FGS-MHTA-C...................................................... 6-1
FGS-MJWR-C..................................................... 6-1
FGS-MSDS-C...................................................... 6-1
FGS-MSHA-C...................................................... 6-1
FGS-MTRM-D....................................................6-3
FGS-TRMP42.....................................................6-3
FGS-V9E44........................................................6-3
FGS-VQE22........................................................6-3
FGS-VQE44........................................................6-3
FMT-MW2KUKUBG1A00............................. 7-3
FOA-INASC05................................................. 11-14
FOA-INASC10.................................................. 11-14
FOA-INASC15.................................................. 11-14
FOA-INASC20................................................. 11-14
FOA-INLC05.................................................... 11-14
FOA-INLC10...................................................... 11-14
FOA-INLC15...................................................... 11-14
FOA-INLC20.................................................... 11-14
FOA-INSC05.................................................... 11-14
FOA-INSC10..................................................... 11-14
FOA-INSC15...................................................... 11-14
FOA-INSC20.................................................... 11-14
FPC-CLNKIT.......................................................11-8
FPC-CLNKIT1.....................................................11-8
FPC-CLNKIT2....................................................11-8
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
F (Continued)
H
FPX-1TR000-000............................................ 2-3
FPX-12APL0J..................................................... 2-3
FPX-12APL0JSP3............................................ 2-3
FPX-12APR0J..................................................... 2-3
FPX-12APR0JSP3............................................ 2-3
FPX-12MPLS0J.................................................. 2-3
FPX-12MPRS0J................................................. 2-3
FPX-24APL08................................................... 2-3
FPX-24APL08SP3........................................... 2-3
FPX-24APR08................................................... 2-3
FPX-24APR08SP3.......................................... 2-3
FPX-24MPLS08................................................ 2-3
FPX-24MPRS08............................................... 2-3
FPX-N0AP00.................................................... 2-3
FST-ACC001.................................................... 3-25
FST-ACC006................................................... 3-25
FST-F3DF-FT.....................................................2-6
FST-F3DF-HS....................................................2-6
FST-F3DF-MT-D...............................................2-6
FST-F3DF-NT....................................................2-6
FVM-19X350W-M6......................................... 7-8
FVM-19X700W................................................. 7-8
FWP-OADM1471MOD-00........................... 7-8
FWP-OADM1491MOD-00........................... 7-8
FWP-OADM1511MOD-00............................. 7-8
FWP-OADM1531MOD-00........................... 7-8
FWP-OADM1551MOD-00........................... 7-8
FWP-OADM1571MOD-00............................ 7-8
FWP-OADM1591MOD-00........................... 7-8
FWP-OADM1611MOD-00............................. 7-8
FWP-WDMKIT-FT........................................... 7-3
FWU-27A7AAG1ABK00.............................. 7-3
FWU-CHASSIS-8............................................. 7-3
FWU-REMOTEWDM..................................... 7-3
FWU-SMCW1470XVR................................... 7-8
FWU-SMCW1490XVR.................................. 7-8
FWU-SMCW1510XVR.................................... 7-8
FWU-SMCW1530XVR................................... 7-8
FWU-SMCW1550XVR................................... 7-8
FWU-SMCW1570XVR................................... 7-8
FWU-SMCW1590XVR.................................. 7-8
FWU-SMCW1610XVR.................................... 7-8
FWU-SMHU1550XVR.................................... 7-3
FWU-SMRU1310XVR..................................... 7-3
HG302N-000....................................................4-5
INP............................................................................ 11-1
INP-700ABC-1.................................................... 11-1
INP-700UC-1....................................................... 11-1
INP-850-1.............................................................. 11-1
INP-1900-1............................................................ 11-1
INP-8519-1............................................................. 11-1
INP-AWS-1............................................................ 11-1
G
GAK-FEC001..........................................3-25, 11-11
GMT Dummy.....................................................8-3
GND-STPKIT..........................................3-25, 11-11
Grounding Lug Kit.........................................11-12
12-5
K
KLM-05.................................................................8-3
KLM-10..................................................................8-3
KLM-15...................................................................8-3
KLM-20.................................................................8-3
KLM-25.................................................................8-3
KLM-30.................................................................8-3
KLM-CAP.............................................................8-3
KLM Dummy......................................................8-3
L
LSX-1L0000.......................................................2-4
LSX-1L1012-A-SPL............................................2-4
LSX-1L1022-A-SPL...........................................2-4
LSX-1L5013-A-SPL...........................................2-4
LSX-1L5023-A-SPL.........................................2-4
LSX-2L0000......................................................2-4
LSX-3L1042-A-SPL.........................................2-4
LSX-3L5043-A-SPL........................................2-4
LSX-6L0000......................................................2-4
LSX-6L1062-A-SPL.........................................2-4
LSX-6L5063-A-SPL........................................2-4
LSX-7L0000......................................................2-4
LSX-7L1092-A-SPL.........................................2-4
LSX-7L5093-A-SPL........................................2-4
LSX-ACCVCGKIT.............................................2-6
LSX-CBLCLMPKIT...........................................2-6
LSX-SPLCA06................................................... 2-5
LSX-TL0000......................................................2-4
LSX-TL1122-A-SPL...........................................2-4
LSX-TL5123-A-SPL..........................................2-4
M
MDP-CH................................................................ 11-7
MR3919-000......................................................4-8
MPA-PCLCJ30003M-NC.............................5-9
MPA-PCLCJ30004M-NC............................5-9
MPA-PCLCJ30005M-NC.............................5-9
MPA-PCSCJ30003M-NC............................5-9
MPA-PCSCJ30004M-NC............................5-9
MPA-PCSCJ30005M-NC............................5-9
MPA-PCLCJ50003M-NC.............................5-9
MPA-PCLCJ50004M-NC............................5-9
MPA-PCLCJ50005M-NC.............................5-9
MPA-PCSCJ50003M-NC............................5-9
MPA-PCSCJ50004M-NC............................5-9
MPA-PCSCJ50005M-NC............................5-9
P
P-1............................................................................8-3
P-1 1/2.....................................................................8-3
P-1 1/3.....................................................................8-3
P-1/2........................................................................8-3
P-1/4........................................................................8-3
P-2...........................................................................8-3
P-2 1/2...................................................................8-3
P-2/10....................................................................8-3
P-3...........................................................................8-3
P-3 1/2...................................................................8-3
P-3/4......................................................................8-3
P-3/8......................................................................8-3
P-4...........................................................................8-3
P-5...........................................................................8-3
P-7 1/2....................................................................8-3
P-10.........................................................................8-3
P-12..........................................................................8-3
P-15..........................................................................8-3
PWX-001RGCSD10PSDB............................. 8-1
PWX-041RCA4G4YSPWP........................... 8-1
PWX-041RCK4G4YSPWP........................... 8-1
R
RCP-1J1DUE03100.......................................... 2-2
RCP-1J1DUE06100.......................................... 2-2
RCP-1J1DUE09200......................................... 2-2
RCP-1J2DUE03100......................................... 2-2
RCP-1J2DUE06100......................................... 2-2
RCP-1J2DUE09200........................................ 2-2
RCP-1K1DUE03100.......................................... 2-2
RCP-1K1DUE06100......................................... 2-2
RCP-1K1DUE09200........................................ 2-2
RCP-1K2DUE03100........................................ 2-2
RCP-1K2DUE06100........................................ 2-2
RCP-1K2DUE09200....................................... 2-2
RH0073-000.....................................................4-6
RH0090-000....................................................4-6
RH0199-000...................................................... 4-7
RH0200-000.................................................... 4-7
RLK-001................................................................8-4
RLK-002...............................................................8-4
RLK-003...............................................................8-4
RMG-12MPOBC3........................................... 3-23
RMG-12MPOBQ3........................................... 3-23
RMG-12MPOCC3........................................... 3-23
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
TE Connectivity DAS Ordering Guide
Index
R (Continued)
RMG-12MPOCQ3........................................... 3-23
RMG-12MPODC4........................................... 3-23
RMG-12MPODQ4.......................................... 3-23
RMG-12MPOSC8........................................... 3-23
RMG-12MPOSQ8........................................... 3-23
RMG-24MPOBQ3......................................... 3-23
RMG-24MPOCQ3......................................... 3-23
RMG-24MPODQ4......................................... 3-23
RMG-24MPOSQ8......................................... 3-23
RMG-1000-000B.......................................... 3-23
RMG-2000-000B........................................ 3-23
RMG-4000-000B........................................ 3-23
S
SKSSDUXXX......................................................3-4
V
VCG-31CS.......................................................... 11-13
W
WMG-2000-00B.......................................... 3-22
WMG-4000-00B......................................... 3-22
WMG-8000-00B.......................................... 3-22
WSC-CH0-CW.................................................. 7-8
X
XJ261N-000.......................................................4-5
12-6
www.te.com/TelecomNetworks 1-800-366-3891 x73000 Fax: 1-952-917-3237 4/14 315802AE
CATALOG
Contact us:
P.O. Box 1101
Minneapolis, Minnesota
USA 55440-1101
Tel:1-800-366-3891 x73000
1-952-917-3000
Fax: 1-952-917-3237
www.te.com/TelecomNetworks
TE Connectivity, TE connectivity (logo), Tyco Electronics, and TE (logo) are trademarks of the TE Connectivity Ltd. family of companies
and its licensors.
While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does
not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at
any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including,
but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are
for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult
TE Connectivity for the latest dimensions and design specifications.
Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved.
315802AE 4/14 Original © 2013