TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions Description The TOUCH 1500 is a panel mounted touch screen display used in conjunction with Raychem NGC-40 and NGC-20 (Europe only) control and monitoring devices. The TOUCH 1500 is rated IP 65 (NEMA 4) and is approved for nonhazardous indoor locations. The TOUCH 1500 kit includes all hardware required for mounting in a suitable electrical panel. These instructions describe how to mount the TOUCH 1500 in an electrical panel and are intended only for personnel experienced in panel construction. Tools Required TOUCH 1500 installed in a panel • Masking tape • #16 (3/16) drill bit • Metal file • Phillips screwdriver • Jig saw (recommend using carbon steel blade with 24TPI) Additional Materials (to be ordered separately) Qty Description 2 9 pin D-Sub to 10 pin terminal block PCB 2 Serial Communication cable Kit Contents QtyDescription 1 TOUCH 1500 display 10 Mounting clips 1 ADAM 4069-CID2 relay module 1 5-ft 9-pin RS-232 (null modem) cable Approvals/Certifications Nonhazardous Locations E180881 I.T.F. (Russia, Kazakhstan, Belarus) For other countries contact your local Pentair representative. General Area of use Supply voltage Network Connection Nonhazardous, Indoors (IP65, NEMA 4) 10 – 30 Vdc Local/ Remote Port Amperage rating Steady state 1.8 A Surge current 16 A Operating 0°C to 50°C (32°F to 122°F) w/o space heater, –30°C to 50°C temperature (–22°F to 122°F) using space heater and screen cover Storage –20°C to 60°C (–4°F to 140°F) temperature Dimensions 449.9 mm W X 315.6 mm H X 141.7 mm D (17.74 in. W X 12.44 in. H X 5.58 in. D) Alarm Outputs Relay output LCD Display Display Touch Screen 11 1 4 6 1 6 2 2 1 1 1 Manufacturer Manufacturer PN Phoenix 2315162 Contacts L-COM "CSMN9MF-xx xx=Length in Ft." Terminal Blocks Weidmuller 163205 Type ZS1 Fuse Block Weidmuller 161649 PE Terminal (Earth Ground) Weidmuller 1632080000 End plates / Partition Weidmuller 1632090000 End plate / Partition Weidmuller 1896330000 End Plate Stops Weidmuller 38356 Jumpers, 2 Position Weidmuller 1608950000 Jumpers, 3 Position Weidmuller 1608960000 Fuse, 1 amp, 250 V Square D MLD-1 Power Supply, 24 Vdc, 2.5 Amp Mean Well DR-120-24 Push to test alarm light; Idec 24 Vdc Idec ALW29911-D-R-24 One Form C relay rated at 3 A @ 250 Vac. Relay is used as a common alarm. LCD is a 15-in XGA, color TFT transflective device with integral CCFL backlight 4-wire resistive touch screen interface for user entry WARNING: FIRE Hazard: The Touch 1500 must not be used in hazardous locations. Electrical components within the unit could ignite flammable gases. Do not install the unit where it may be exposed to flammable gases. INDUSTRIAL HEAT TRACING SOLUTIONS Local RS-232 * RS-232/RS-485 ports may be used to communicate with host computers DTS (Raychem Supervisor Software) or DCS A non-isolated, 9 pin D sub male Remote RS-485 2-wire isolated, 9 pin D sub male Data rate Maximum cable length Field Port 9600 to 57600 baud Signals For RS-485 not to exceed 1200 m (4000 ft). Cable to be shielded twisted pair. RS-485, 2-wire isolated. Used to communicate with external devices, such as NGC-40-BRIDGE. Maximum cable length not to exceed 1200 m (4000 ft). Cable to be shielded twisted pair. 2-wire isolated, 9 pin D sub male Data rate To 9600 baud LAN USB Ports 10/100 Base-T Ethernet port with Link and Activity Status LEDs (X2) USB 2.0 Host port Type A receptacle (X4) IMPORTANT: The TOUCH 1500 is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components. • Handle with care to avoid mechanical damage. • Keep electronics dry. • Avoid exposure to static electricity. • Avoid contamination with metal filings, liquids, or other foreign matter. • Use agency-approved conduit bushings, adapters, and cable glands to keep the enclosure protected from dust and fluids. GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 1/8 Provide Suitable Panel Enclosure, and Determine Locations for TOUCH 1500 Assembly in Panel X 1.Provide suitable panel enclosure To protect its electronic components, the TOUCH 1500 must be mounted in a non-hazardous location panel with a minimum IP32 (NEMA 1) enclosure. An IP52 (NEMA 12) or better enclosure is recommended. The TOUCH 1500 assembly comes with a sealing gasket and hardware to mount the enclosure. 2. Determine locations for the TOUCH 1500 assembly in the electrical panel The TOUCH 1500 should be located on the front of the panel near eye level (for convenient viewing). The TOUCH 1500 assembly is an electronic unit and must not be located where it will be exposed to strong magnetic fields or excessive vibration. Note: The Raychem TOUCH 1500 is designed for operation in ambient temperatures from 0°C to 50°C (32°F to 122°F). If the ambient temperature is outside this range, a space heater with screen window kit and/or cooling fan will be required in the panel. Panel door Touch 1500 assembly location Panel C1 C2 C3 C4 C5 C6 C7 1 7 9 11 13 Alarm light INDUSTRIAL HEAT TRACING SOLUTIONS C9 C10 2 4 3 5 C8 CB1 CB3 CB5 CB7 CB9 CB11 CB13 CB15 CB17 CB19 CB21 CB23 CB25 CB27 CB29 CB31 CB33 CB35 CB37 CB39 15 CB2 CB4 CB6 CB8 CB10 CB12 CB14 CB16 CB18 CB20 CB22 CB24 CB26 CB28 CB30 CB32 CB34 CB36 CB38 CB40 CB42 6 8 10 12 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 2/8 Cut Opening and Mount TOUCH 1500 on Front of Panel 1.Locate the TOUCH 1500 on front of panel Locate the TOUCH 1500 assembly on the front of the panel at a level convenient for viewing. Make sure the cover on the back of the assembly will not interfere with existing panel hardware. 4. Mount the user interface assembly onto the panel door • Place the TOUCH 1500 assembly in position. Secure the screen to the enclosure with the 10 mounting clips. TOUCH 1500 display Panel Door +– G 292 mm 11.5 in. 422 mm 16.6 in. Inside of panel door Cutting Area Panel door Note: Cutting the opening for the display is a craft sensitive procedure; if it is not done correctly, the panel door can be damaged. The procedure for laying out and cutting the opening for the display must be undertaken with care, and by personnel qualified and experienced in panel construction. +– G TOUCH 1500 display with sealing gasket 2.Prepare and mark the position of the display opening and mounting holes • Use the cut-out directions to lay out the opening for the TOUCH 1500 display. • Apply two layers of masking tape around the outer perimeter of the intended opening to prevent scratching the panel surface with the jigsaw. • Place the supplied mounting clips in each slot along the sides of the TOUCH 1500. Fasten only hand tight. TOUCH 1500 display 3.Cut the display opening Cut the opening for the TOUCH 1500 with a jigsaw using a 24 TPI blade. Take care not to damage the panel door. Remove all rough edges and burrs with a metal file before proceeding. +– G Mounting clips Note: The following steps are most easily accomplished if the panel door is on a horizontal surface. • Look at the front of the panel, and align the TOUCH 1500 assembly so it is level (loosen clips if necessary to reposition the assembly). • After the display is properly positioned, tighten the mounting clips. Do not overtighten and risk damage to hardware. INDUSTRIAL HEAT TRACING SOLUTIONS GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 3/8 TOUCH 1500 Cut Out Dimensions Panel Cut Out 422 mm (16.6 in) 292 mm (11.5 in) Panel Cut Out Top of Display Panel Cut Out Area Drawing NOT TO SCALE INDUSTRIAL HEAT TRACING SOLUTIONS GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 4/8 TOUCH 1500 Connection Diagram Incoming power Ethernet Remote Port Reset Switch Ethernet Field Port RS-485 Com 4 Remote Port RS-485 Com 3 Field Port + – G Mouse Keyboard RS-232 Com 1 USB port (X4) Compact flash Connect Power Connect 10 – 30 Vdc to the male power connection fitting located on the bottom side of the TOUCH 1500. Note the polarity of the wires. G – 10 – 30 Vdc + Incoming power +– G Communication The TOUCH 1500 has two isolated RS-485 ports located at the bottom. Field Side Port (RS-485) The RS-485 port labeled “Com 3” is the field side port that is used to communicate with ModBus devices (ie. NGC-40BRIDGE and NGC-20). INDUSTRIAL HEAT TRACING SOLUTIONS *Remote Port (RS-485) – Optional The RS-485 port labeled “Com 4” is the Remote side port that is used to communicate with to a host computer DTS (using Raychem Supervisory Software) or to a DCS. *Local Host Port (RS-232) – Optional The RS-232 port can be used as local Host port that is used to communicate with to a host computer (using Raychem Supervisory Software). GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 5/8 Field Port Communication RS-485 Common Alarm Light and Alarm Relay Mount the supplied ADAM 4069-CID2 module, 9-pin D sub to 10 pin terminal block and 4 terminal block (with 2 position jumpers) on a DIN rail inside the panel enclosure. Mount the alarm light on the panel's door below the touch screen. Data + Field port (to Bridge, NGC-20) Data – Wire per the schematic below. Jumpers RL0NC RL0NO RL0COM RL1NC RL2NC RL1NO RL1COM RL2NC RL3NO RL2COM RL4NO RL3COM RL4COM Shield 5 4 3 2 1 5 4 3 2 1 T 9 8 7 6 T 9 8 7 6 ADAM-4069-CID2 Field Port Com 3 Jumpers Remote Port Com 4 (B) GND 10 (R) +Vs (G) DATA – (Y) DATA + INT+ NC RL7NC RL7COM RL7NC RL6COM RL6NO RL5COM RL5NO (See wiring below) Alarm Lamp Ground Serial communication cable to Field Port/Com 3 (RS-485) + – TOUCH 1500 120/230 Vac 2 1 3 4 24 V Lamp Idec Switch/Lamp +– RS-485 G RS-485 Alarm Lamp To Remote Port/Com 4 (RS-485) Door mounted Data + To host computer Data – Shield Remote Port Connection 5 * Mount the supplied 9-pin D sub to 10-pin terminal block on a DIN rail inside the panel enclosure. Wire per schematic to the right. INDUSTRIAL HEAT TRACING SOLUTIONS 4 3 2 1 T 9 8 7 6 Remote Port Com 4 GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 6/8 Overview of Wiring Data + Data – Field Port Data + Data – Remote Port 5 G Ø Ø or N Jumpers Shield Jumpers RL0NC RL0NO RL0COM RL1NC RL1NO RL2NC RL1COM RL2NC RL3NO RL2COM RL4NO RL3COM RL4COM Common alarm relay 4 3 2 1 5 4 3 2 1 T 9 8 7 6 T 9 8 7 6 ADAM-4069-CID2 Remote Port Com 4 (B) GND 10 (R) +Vs (G) DATA – (Y) DATA + INT+ NC RL7NC RL7COM RL7NC RL6COM RL6NO RL5COM RL5NO Field Port Com 3 Alarm Lamp 2 3 1 4 24 V Lamp Idec Switch/Lamp Ground Incoming Power Terminal Block + – +– TOUCH 1500 G Alarm Lamp Door mounted INDUSTRIAL HEAT TRACING SOLUTIONS GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 7/8 Servicing The TOUCH 1500 contains no user-serviceable parts. Contact your Pentair representative for service and an authorization number if required. Cleaning The touch screen area of the TOUCH 1500 may be cleaned with a damp or dry cloth. Typical window cleaning agents may be applied to aid in the removal of dirt, dust and grease. Do not use abrasive cleaners. Reset Switch Reset Switch The Reset switch can be found on the bottom of the TOUCH 1500. +– G WWW.PENTAIRthermal.COM NORTH AMERICA Europe, Middle East, Africa Asia Pacific Latin America Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel:+1.650.216.1526 Fax: +1.650.474.7711 [email protected] Tel: +32.16.213.511 Fax: +32.16.213.603 [email protected] Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 [email protected] Tel: +1.713.868.4800 Fax: +1.713.868.2333 [email protected] All Pentair trademarks and logos are owned by Pentair or its global affiliates. Pentair reserves the right to change specifications without prior notice. © 2010-2014 Pentair. INDUSTRIAL HEAT TRACING SOLUTIONS GB-RaychemTouch1500-IM-H58559 INSTALL-170 Rev1 8/8
© Copyright 2026 Paperzz