REFLECTED CEILING ARCHITECTURAL SCOPE OF WORK NOTE: NOT ALL NOTES USED ON EACH SHEET SCOPE SHOWN ON REFLECTED CEILING PLANS ONLY DIVISION 5 5.01PAINTED STEEL LINTEL 5.02CONTROL JOINT DIVISION 7 7.01EXPOSED CONSTRUCTION - PAINT DECK SEE FINISH PLANS- NO PAINT (SPRAY-APPLIED FIREPROOFING BEAMS WHERE REQUIRED) DIVISION 7 8.01ACCESS PANEL - SEE SPECIFICATIONS DIVISION 9 9.012'X2' OR 1'X4' SUSPENDED ACOUSTICAL CEILING TYPE 'B' ON 15/16" GRID, SEE PLAN. 9.02GYPSUM BOARD CEILING/SOFFIT PAINTED 9.032'x2' SUSPENDED USDA APPROVED TILE TYPE 'C' ON NON-CORROSIVE 15/16" GRID 9.04PAINTED EXPOSED STRUCTURE, DECK, DUCTWORK, PIPING, CONDUIT, ETC. 9.05PAINTED EXPOSED STAIR STRUCTURE, INCLUDE CHANNELS, PAN, BEAMS, PLATES, CONNECTIONS, GUARDRAILS, & ASSOCIATED ELEMENTS 9.06GYPSUM BOARD CEILING CONTROL JOINT WITH CONTINUOUS 1/2" PREFINISHED ALUMINUM REVEAL TO MATCH PAINT COLOR 9.07SUSPENDED CEILING THERMAL EXPANSION JOINT - SEE DETAILS 9.08WATER RESISTANT GYPSUM BOARD CEILING PAINTED 9.09EXTERIOR DUROCK WITH EXTERIOR PLASTER FINISH CEILING DIVISION 10 10.01DISPLAY CASE WITH INTERIOR LIGHT 10.02PROVIDE AND INSTALL NEW 12'x9' PROJECTION SCREEN DIVISION 11 11.01CEILING MOUNTED PROJECTOR 11.02EXHAUST HOOD DIVISION 12 12.01HEAD MOUNTED MANUAL ROLLER SHADE DIVISION 15 15.01DUCT PENETRATION, SEE MECHANICAL DRAWINGS 15.02NEW MECHANICAL DIFFUSER/GRILLE - SEE MECHANICAL DRAWINGS 15.03NEW SPRINKLER HEADS - SEE FIRE PROTECTION DRAWINGS SEE DIAGRAM ON THIS SHEET FOR LOCATION IN CEILING TILE DIVISION 16 16.01NEW LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS 16.02NEW ELECTRICAL AND DATA DEVICE - SEE ELECTRICAL DRAWINGS COORDINATE LOCATION WITH ELECTRICAL AND MANUFACTURERS RECOMMENDATION FOR INSTALLED EQUIPMENT 16.03NEW SPEAKER -SEE ELECTRICAL DRAWINGS 16.04EXIT SIGN - SEE ELECTRICAL DRAWINGS GENERAL NOTES: 1) 2) 3) 4) 5) 6) 7) 8) ALL CEILING GRIDS SHALL BE CENTERED IN ROOMS UNLESS NOTED OTHERWISE. ALL LIGHT FIXTURES AND DIFFUSERS SHALL BE CENTERED ON THE TILE UNLESS NOTED OR INDICATED OTHERWISE. ALL SPRINKLER HEADS SHALL BE CENTERED ON 2'X2' TILE ALL CEILING HEIGHTS ARE SET ABOVE 0'-0". ALL GYPSUM BOARD SOFFITS SHALL HAVE 5/8" REVEAL EDGE AT ADJACENT PARTITIONS EXCEPT WHERE REQUIRED TO BE FIRE TREATED. COORDINATE SPRAY FIREPROOFING REQUIREMENTS WITH EXITING PLANS AND PROJECT SPECIFICATIONS. CONTRACTOR TO COORDINATE LOCATION OF PLUMBING AND MECHANICAL VALVES. TRANSFORMERS AND ASSOCIATIONS ABOVE-CEILING COMPONENTS WITH LOCATIONS OF CEILING ACCESS PANELS IN GYPSUM BOARD AREAS. ALIGN ALL SOFFITS WITH ADJACENT WALL SURFACE AS INDICATED ON THE DRAWINGS CEILING SYMBOLS KEY 4X4 LIGHT FIXTURE (SEE ELECTRICAL DRAWINGS) 2'x4' LAY-IN FLUORESCENT FIXTURE (SEE ELECTRICAL DRAWINGS) 1'x4' FLUORESCENT FIXTURE (SEE ELECTRICAL DRAWINGS) 1'x4' FLUORESCENT FIXTURE (SEE ELECTRICAL DRAWINGS) 1'x4' WALL MOUNTED FLUORESCENT FIXTURE (SEE ELECTRICAL DRAWINGS) 1'x1' FIXTURE (SEE ELECTRICAL DRAWINGS) 2'x2' LAY-IN FLUORESCENT FIXTURE (SEE ELECTRICAL DRAWINGS) WALL MOUNTED EXIT SIGN (SEE ELECTRICAL DRAWINGS) CEILING MOUNTED EXIT SIGN (SEE ELECTRICAL DRAWINGS) CEILING RECESSED FIXTURE WITH ROUND TRIM (SEE ELECTRICAL DRAWINGS) DISPLAY CASE LIGHT (SEE ELECTRICAL DRAWINGS) PROJECTOR EMERGENCY LIGHTING UNIT (SEE ELECTRICAL DRAWINGS) RETURN AIR DIFFUSER (SEE MECHANICAL DRAWINGS) SUPPLY AIR DIFFUSER (SEE MECHANICAL DRAWINGS) SUPPLY SLOT DIFFUSER (SEE MECHANICAL DRAWINGS) ACCESS PANEL (CEILING) ARE NOT INDICATED COORDINATE WITH MECHANICAL DRAWINGS. FINAL LOCATION COORDINATE WITH ARCHITECT SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS) CEILING MOUNTED SPEAKER (SEE ELECTRICAL DRAWINGS) WALL MOUNTED SPEAKER (SEE ELECTRICAL DRAWINGS) SMOKE DETECTOR (SEE ELECTRICAL DRAWINGS) CARBON MONOXIDE DETECTOR (SEE ELECTRICAL DRAWINGS) HEAT DETECTOR (SEE ELECTRICAL DRAWINGS) GYPSUM BOARD CEILING (PAINTED) WINDOW MOUNTED SHADES AND PREFINISHED HOUSING RECESSED RADIANT CEILING PANEL COORDINATE WITH MECHANICAL DRAWINGS RP RECESSED CONVECTION UNIT HEATER COORDINATE WITH MECHANICAL DRAWINGS CUH OCCUPANCY SENSOR PHOTO SENSOR PHOTO CELL PC V VISUAL ALARM (SEE ELECTRICAL DRAWINGS) V WALL MOUNTED VISUAL ALARM (SEE ELECTRICAL DRAWINGS) AUDIO VISUAL ALARM (SEE ELECTRICAL DRAWINGS) AV SPRINKLER HEAD LOCATION DIAGRAM OF TILE, UNO OF TILE, UNO TYPICAL 2x2 LAY IN CEILING TILE
© Copyright 2026 Paperzz