1307-05 2.1 Reflected Ceiling Plan

REFLECTED CEILING ARCHITECTURAL
SCOPE OF WORK
NOTE: NOT ALL NOTES USED ON EACH SHEET
SCOPE SHOWN ON REFLECTED CEILING PLANS ONLY
DIVISION 5
5.01PAINTED STEEL LINTEL
5.02CONTROL JOINT
DIVISION 7
7.01EXPOSED CONSTRUCTION - PAINT DECK SEE FINISH PLANS- NO
PAINT (SPRAY-APPLIED FIREPROOFING BEAMS WHERE
REQUIRED)
DIVISION 7
8.01ACCESS PANEL - SEE SPECIFICATIONS
DIVISION 9
9.012'X2' OR 1'X4' SUSPENDED ACOUSTICAL CEILING TYPE 'B' ON
15/16" GRID, SEE PLAN.
9.02GYPSUM BOARD CEILING/SOFFIT PAINTED
9.032'x2' SUSPENDED USDA APPROVED TILE TYPE 'C' ON
NON-CORROSIVE 15/16" GRID
9.04PAINTED EXPOSED STRUCTURE, DECK, DUCTWORK, PIPING,
CONDUIT, ETC.
9.05PAINTED EXPOSED STAIR STRUCTURE, INCLUDE CHANNELS,
PAN, BEAMS, PLATES, CONNECTIONS, GUARDRAILS, &
ASSOCIATED ELEMENTS
9.06GYPSUM BOARD CEILING CONTROL JOINT WITH CONTINUOUS
1/2" PREFINISHED ALUMINUM REVEAL TO MATCH PAINT COLOR
9.07SUSPENDED CEILING THERMAL EXPANSION JOINT - SEE DETAILS
9.08WATER RESISTANT GYPSUM BOARD CEILING PAINTED
9.09EXTERIOR DUROCK WITH EXTERIOR PLASTER FINISH CEILING
DIVISION 10
10.01DISPLAY CASE WITH INTERIOR LIGHT
10.02PROVIDE AND INSTALL NEW 12'x9' PROJECTION SCREEN
DIVISION 11
11.01CEILING MOUNTED PROJECTOR
11.02EXHAUST HOOD
DIVISION 12
12.01HEAD MOUNTED MANUAL ROLLER SHADE
DIVISION 15
15.01DUCT PENETRATION, SEE MECHANICAL DRAWINGS
15.02NEW MECHANICAL DIFFUSER/GRILLE - SEE MECHANICAL
DRAWINGS
15.03NEW SPRINKLER HEADS - SEE FIRE PROTECTION DRAWINGS
SEE DIAGRAM ON THIS SHEET FOR LOCATION IN CEILING TILE
DIVISION 16
16.01NEW LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
16.02NEW ELECTRICAL AND DATA DEVICE - SEE ELECTRICAL
DRAWINGS COORDINATE LOCATION WITH ELECTRICAL AND
MANUFACTURERS RECOMMENDATION FOR INSTALLED
EQUIPMENT
16.03NEW SPEAKER -SEE ELECTRICAL DRAWINGS
16.04EXIT SIGN - SEE ELECTRICAL DRAWINGS
GENERAL NOTES:
1)
2)
3)
4)
5)
6)
7)
8)
ALL CEILING GRIDS SHALL BE CENTERED IN ROOMS UNLESS
NOTED OTHERWISE.
ALL LIGHT FIXTURES AND DIFFUSERS SHALL BE CENTERED ON THE
TILE UNLESS NOTED OR INDICATED OTHERWISE.
ALL SPRINKLER HEADS SHALL BE CENTERED ON 2'X2' TILE
ALL CEILING HEIGHTS ARE SET ABOVE 0'-0".
ALL GYPSUM BOARD SOFFITS SHALL HAVE 5/8" REVEAL EDGE AT
ADJACENT PARTITIONS EXCEPT WHERE REQUIRED TO BE FIRE
TREATED.
COORDINATE SPRAY FIREPROOFING REQUIREMENTS WITH
EXITING PLANS AND PROJECT SPECIFICATIONS.
CONTRACTOR TO COORDINATE LOCATION OF PLUMBING AND
MECHANICAL VALVES. TRANSFORMERS AND ASSOCIATIONS
ABOVE-CEILING COMPONENTS WITH LOCATIONS OF CEILING
ACCESS PANELS IN GYPSUM BOARD AREAS.
ALIGN ALL SOFFITS WITH ADJACENT WALL SURFACE AS INDICATED
ON THE DRAWINGS
CEILING SYMBOLS KEY
4X4 LIGHT FIXTURE (SEE ELECTRICAL DRAWINGS)
2'x4' LAY-IN FLUORESCENT FIXTURE (SEE ELECTRICAL
DRAWINGS)
1'x4' FLUORESCENT FIXTURE (SEE ELECTRICAL
DRAWINGS)
1'x4' FLUORESCENT FIXTURE (SEE ELECTRICAL
DRAWINGS)
1'x4' WALL MOUNTED FLUORESCENT FIXTURE (SEE
ELECTRICAL DRAWINGS)
1'x1' FIXTURE (SEE ELECTRICAL DRAWINGS)
2'x2' LAY-IN FLUORESCENT FIXTURE (SEE
ELECTRICAL DRAWINGS)
WALL MOUNTED EXIT SIGN (SEE ELECTRICAL
DRAWINGS)
CEILING MOUNTED EXIT SIGN (SEE ELECTRICAL
DRAWINGS)
CEILING RECESSED FIXTURE WITH ROUND TRIM (SEE
ELECTRICAL DRAWINGS)
DISPLAY CASE LIGHT (SEE ELECTRICAL DRAWINGS)
PROJECTOR
EMERGENCY LIGHTING UNIT (SEE ELECTRICAL
DRAWINGS)
RETURN AIR DIFFUSER (SEE MECHANICAL DRAWINGS)
SUPPLY AIR DIFFUSER (SEE MECHANICAL DRAWINGS)
SUPPLY SLOT DIFFUSER (SEE MECHANICAL DRAWINGS)
ACCESS PANEL (CEILING) ARE NOT INDICATED
COORDINATE WITH MECHANICAL DRAWINGS. FINAL
LOCATION COORDINATE WITH ARCHITECT
SPRINKLER HEAD (SEE FIRE PROTECTION DRAWINGS)
CEILING MOUNTED SPEAKER (SEE ELECTRICAL
DRAWINGS)
WALL MOUNTED SPEAKER (SEE ELECTRICAL
DRAWINGS)
SMOKE DETECTOR (SEE ELECTRICAL DRAWINGS)
CARBON MONOXIDE DETECTOR (SEE ELECTRICAL
DRAWINGS)
HEAT DETECTOR (SEE ELECTRICAL DRAWINGS)
GYPSUM BOARD CEILING (PAINTED)
WINDOW MOUNTED SHADES AND PREFINISHED
HOUSING
RECESSED RADIANT CEILING PANEL
COORDINATE WITH MECHANICAL
DRAWINGS
RP
RECESSED CONVECTION UNIT
HEATER COORDINATE WITH
MECHANICAL DRAWINGS
CUH
OCCUPANCY SENSOR
PHOTO SENSOR
PHOTO CELL
PC
V
VISUAL ALARM (SEE ELECTRICAL DRAWINGS)
V
WALL MOUNTED VISUAL ALARM (SEE ELECTRICAL
DRAWINGS)
AUDIO VISUAL ALARM (SEE ELECTRICAL DRAWINGS)
AV
SPRINKLER HEAD LOCATION DIAGRAM
OF TILE, UNO
OF TILE, UNO
TYPICAL 2x2 LAY IN
CEILING TILE