SCALE-BANTM A Sustainable solution for achieving ZLD & Scale free operation. A Fit & Forget System… Continuously improving the possibilities to Innovate the conservation of natural resources…. A Non Chemical Water Treatment… Our Vision: Our Vision is to provide a Self Sustainable, Efficient and Cost Effective Zero Liquid Discharge (ZLD) solution in HVAC. A Fit & Forget System Revolution in Water Treatment… Optimizing Production OUR MOTTO Maximizing Water Conservation Minimizing Water Pollution A Fit & Forget System Revolution in Water Treatment… SCALE-BANTM equipment has been developed by years of researches & trials. It is in commercial production since 1999. Now the technology has been proven and well tested. We have references of its working in various type of industries and applications where this equipment is successfully running. “SCALE-BANTM Equipment is an online non chemical water treatment equipment which gives excellent water savings beside total prevention of hard water scale in heat exchangers in cooling water services.” A Fit & Forget System Revolution in Water Treatment… Problems & concerns: Zero Liquid Discharge (ZLD) Conventional systems like Effluent RO & MEE are very costly to install & operate SCALING IN HEAT EXCHANGERS Impacts of scaling: Loss of production, Increased power consumption and Increased steam consumption. Increased water consumption and water pollution A Fit & Forget System Revolution in Water Treatment… Facts & figures: “A scale of even 0.5 mm causes an energy loss of 7%” Efficiency Loss in % 4 11 27 48 90 0.3 0.71 4.7 9.5 A Fit & Forget System Revolution in Water Treatment… Available methods for ZLD & Scale Prevention. Conventional Softener Plant Anti Scaling Chemical Treatment SCALE-BAN NonChemical Water Treatment Equipment Effluent RO & MEE A Fit & Forget System Revolution in Water Treatment… Limitations of Conventional treatment Methods: ETP treated water can be consumed only after treatment through RO Plant. For Utilization of RO Reject Secondary RO / MEE is required. Restricted level of hardness and TDS in cooling water (Heavy Blow down). Water consumption, wastage and pollution is increased. Recurring Expenses on softener operation, Effluent RO/MEE operations and anti-scalant chemical dosing in cooling towers. No guarantee for zero scale (Production losses). Cleaning of the tubes is required. ‘SCALEBAN’ SCENARIO: Direct use of ETP treated & RO rejected water in cooling tower with ZERO OPERATIONAL EXPENDITURE. Cooling tower will be operated at very high hardness up to 20,000 PPM and at very high TDS up to 2,00,000 PPM. Unbelievable COC level of 15-20 in cooling tower. Reduction in cooling tower blow down by 90%. Elimination of Softener & anti-scaling chemical from cooling tower. Zero scale is guaranteed for 20 years. No requirement of cleaning of the heat exchangers. Working Principle of TM SCALE-BAN : Innovation evolved from the problem HOW DOES SCALEBAN PREVENT SCALING IN YOUR EQUIPMENT? SCALEBAN is an online pipe shaped mechanical device which houses very specially designed core that is Sintered with number of electronegative elements in their order of increasing electro negativity in the direction of water/fluid flow. As feed water/fluid passes through SCALEBAN, it acts as an electrolyte while it comes in contact with the core placed inside SCALEBAN. SCALEBAN makes use of Galvanic principle by locally enhancing the pH value of feed water/fluid. Due to the Galvanic action, the core gets negatively charged and attracts the lightest ions present in the fluid i.e. Hydrogen ion towards itself. The relationship between pH of water/fluid and H+ ion is expressed by the formula pH α 1/H+. Thus, with the concentration of H+ ion becoming comparatively less in the water/fluid inside the equipment, pH value increases, there by precipitating Calcium and Magnesium salts before it comes in contact with hot tubes. Consequently, once the precipitation of these hardness causing salts has taken place, further precipitation due to temperature variation is not possible. SCALEBAN precipitates out Calcium and Magnesium bicarbonates in the colloidal form of Aragonite crystals much before the water/fluid attains the critical temperature of super saturation due to its coming in contact with hot tubes. These precipitated salts are in the colloidal form (small particles dispersed in another substance) and are suspended in water/fluid, and because of their very small size and lighter weight, the water/fluid flowing through SCALEBAN carries away these precipitated salts. THE NET RESULT IS TOTAL PREVENTION OF HARD SCALE IN THESE SYSTEMS. S1 Ca++ Mg++ H.E. S2 T1 T2 Temperature Relationship of Temperature & Solubility of Ca2+ and Mg2+ in Liquid SCALEBAN SOLUBILITY SOLUBILITY SOLUBILITY CHARACTERISTICS OF LIQUID S1 Ca++ SCALEBAN Mg++ S2 P1 P2 pH Value Relationship of pH & Solubility of Ca2+ and Mg2+in Liquid GALVANIC PRINCIPLE Working process of SCALE-BANTM A Fit & Forget System Revolution in Water Treatment… Cooling Tower PUMP Precipitated Scaling salts are colloidal particles of non sticky nature thus do not deposit on the Heat Exchanger’s surface H+ H+ H+ H+ H+ H+ H+ H+ -Ve Heat Exchanger Charge H+ H+ H+ A Fit & Forget System H+ H+ H+ H+ H+ Revolution in Water Treatment… HOW TO DESIGN A SELF SUSTAINABLE, EFFICIENT AND COST EFFECTIVE ZERO LIQUID DISCHARGE MODEL!! A Fit & Forget System Revolution in Water Treatment… CONVENTIONAL COOLING WATER TREATMENT SYSTEM FOR ZERO LIQUID DISCHARGE (ZLD) (WITHOUT SCALEBAN) SOFT WATER Make up water SALTY WATER COOLING TOWER -------------------------------3-4 COC ------------------------------------------------------------ EFFLUENT TREATMENT PLANT ETP TREATED WATER CT Blow Down water RO PLANT 1 RO PERMEATE PROCESS APPLICATIONS RO PLANT 2 CONDENSER/ COOLERS CONDENSER/ COOLERS NON-CONVENTIONAL COOLING WATER TREATMENT SYSTEM FOR ZERO LIQUID DISCHARGE (ZLD) (WITH SCALEBAN) SOFT WATER Make up water SALTY WATER COOLING TOWER -------------------------------15-20 COC ------------------------------------------------------------ EFFLUENT TREATMENT PLANT ETP TREATED WATER Negligible Blow Down due to high COC. Hence can be directly taken for ash cooling / gardening RO PLANT 1 RO PERMEATE PROCESS APPLICATIONS RO PLANT 2 CONDENSER/ COOLERS CONDENSER/ COOLERS FINAL SCHEME WITH SCALEBAN FOR ACHIEVING ZERO LIQUID DISCHARGE (ZLD) CLARIFIED / RO REJECT / ETP TREATED WATER Make up water COOLING TOWER ------------------------------------------------------------------------------------------- SCALEBAN SCALEBAN Negligible Blow Down due to high COC. Hence can be directly taken for ash cooling / Dust seperation CONDENSER / COOLERS CONDENSER / COOLERS Working Parameters of SCALE-BANTM: • Neutral pH value of water should be maintained between 7.5 - 8.3 • The Scaleban should be installed as close to Heat Exchangers. A Fit & Forget System Revolution in Water Treatment… M/s NTPC DADRI LTD., DADRI (UP) 490MW X 2Nos. SCALEBAN INSTALLATION IN 490MW POWER PLANT CONDENSER (NTPC DADRI) A Fit & Forget System Revolution in Water Treatment… 2X490MW NTPC, DADRI TPP One pass of Unit 5 condenser opened on July 22, 2015 and found Scale free after 15 months. A Fit & Forget System Unit 5 condenser tube condition before installation of Scaleban Revolution in Water Treatment… SCALEBAN PERFORMANCE RESULTS 30th Dec. 2015 1. With Installation of Scaleban no scale has been observed during the complete test. 2. Calculated water saving of 31.44%, anti-scaling chemical saving of 100% and considerable reduction in sulfuric acid consumption and pumping power. 3. NTPC Dadri had maintained 8.5 COC and may further increase to 10 depending upon water requirement for other uses in the plant. A Fit & Forget System Revolution in Water Treatment… BHUSHAN POWER & STEEL LTD., Sambalpur (Orissa) Power Plant : P.O.Date : 01 May 2011 1. 130MW X 3 Nos. 2. 60MW X 1 No. 3. 40MW X 1 No. 4. 8MW X 2Nos. A Fit & Forget System CSP Plant : P.O.Date : 01 May 2011 Oxygen Plant : P.O. Date : 01 May 2011 Revolution in Water Treatment… Bengal Energy Ltd., Kharagpur (WB) 40MW CPP (Installation in March 2014) Condenser tubes at 15 COC A Fit & Forget System Revolution in Water Treatment… Nagarjuna Agri Chem Cooling tower water analysis report A Fit & Forget System Revolution in Water Treatment… M/S AGRIBIOTECH INDUSTRIES LIMITED, Ajitgarh, Sikar, Rajasthan Capacity: 65 KLPD pH: 7.8 Total Hardness: 30000 PPM TDS: 75000 PPM CHLORIDES : 22000 PPM COD: 1000 PPM A Fit & Forget System Revolution in Water Treatment… M/s PEARL DISTILLERY LTD., Ongole (A.P.) Capacity: 65 KLPD Total Hardness: 3000 PPM TDS: 15000 PPM COD: 400 BOD: 250 A Fit & Forget System Revolution in Water Treatment… M/S CHAMBAL FERTILIZER, KOTA (RAJ.) 1. SCALE-BAN EQUIPMENT AT 11E-37 INSTALLED ATR-2008 2. SCALE-BAN EQUIPMENT AT 21 E-07 INSTALLED ATR-2008 A Fit & Forget System Revolution in Water Treatment… Sanghvi Organics, Ankleshwar A Fit & Forget System Revolution in Water Treatment… M/s NEERAJ POWER, TILDA, RAIPUR (C.G.) A Fit & Forget System Revolution in Water Treatment… M/s DEEPAK NITRITE LTD., VADODARA (GUJARAT) A Fit & Forget System Revolution in Water Treatment… M/s WAVE INDUSTRIES LTD., ALIGARH (UP) 90KLPD A Fit & Forget System Revolution in Water Treatment… M/s ENRICA ENTERPRISES PVT. LTD. (GRAIN BASED DISTILLERY), CHENNAI (80KLPD) A Fit & Forget System Revolution in Water Treatment… References in Industries A Fit & Forget System Revolution in Water Treatment… Scaleban Applications…. POWER PLANT SOLVENT EXTRACTION PLANT A Fit & Forget System CHEMICAL PLANT PHARMA PLANT DISTILLERY PLANT TEXTILE INDUSTRIES Revolution in Water Treatment… Thank You! For Your Attention… A Fit & Forget System Revolution in Water Treatment…
© Copyright 2026 Paperzz