Fire Alarm Systems | FMC‑210‑SM Single Action Call Points FMC‑210‑SM Single Action Call Points ▶ Alarm triggering by breaking of the glass pane ▶ Variable labeling possible with foil sets ▶ Indicator LED for alarm or for inspection evaluation ▶ Call point query routines with evaluation and multiple transmission ▶ Individual call point identification The FMC‑210‑SM Single Action Call Points are used to trigger the alarm manually, and can be used in the Local SecurityNetwork LSN and LSN improved. The FMC‑210‑SM Single Action Call Points are designed for indoor deployment. Individual call point identification with display of the call point address on the fire panel ensures the quick location of the triggered call point. Certifications and Approvals Functions Region Certification Germany VdS G 207008 FMC-210-SM-G-R Installation/Configuration Notes • • With single action call points, the alarm is triggered when the glass plate (2) is broken and the button (3) springs up. This activates the microswitch for alarm triggering and the indicator LED (4) blinks. The call point (3) can be reset after inserting a new glass pane (2) and closing the door of the single action call point (1). The indicator LED (4) goes out. This does not reset the alarm on the fire panel. • • Manual call points must be mounted visibly along escape and rescue routes (e. g. exits, passageways, stairwells) and be easily accessible. An installation height of 1400 mm ±200 mm, measured from the middle of the manual call point to the floor, must be maintained. Manual call points must be adequately illuminated by sunlight or another light source (including emergency lighting if present). The maximum number of LSN elements that may be connected depends on their current consumption from the LSN data line. The limit values should be taken from the product information supplied with the fire panel used. www.boschsecurity.com 2 | FMC‑210‑SM Single Action Call Points • Further standards, guidelines and planning recommendations regarding the installation location etc., should also be taken into consideration (see Fire Detection manual). The regulations of the local fire services must be observed. Parts Included TypeNumber. Component FMC‑210‑SM‑G‑B Form G, Blue Single Action Call Point for indoor use, direct triggering (type A) Installation notes in accordance with VdS/VDE • The distance between manual call points should not be more than 100 m according to DIN 14675 or 80 m according to VdS. • In high risk areas, manual call points should be installed at a distance of max. 40 m (VDE 0833 Part 2, Point 7.2.6). FMC‑210‑SM‑G‑R Form G, Red Single Action Call Point for indoor use, direct triggering (type A Installation • The cable duct can be surface-mounted or flushmounted. Electrical • Note The key must be ordered separately. Technical Specifications Operating voltage 15 V DC . . . 33 V DC Current consumption 0.4 mA Mechanics Dimensions (H x W x D) 135 x 135 x 40 mm Housing material Plastic, ASA Colors • • FMC-210-SM-G-R Red, RAL 3001 FMC-210-SM-G-B Blue, RAL 5005 Weight • Installation in fire hose cabinets is possible in three ways: Approx. 235 g Environmental Considerations Protection class as per EN 60529 IP 52 Permissible operating temperature -10 °C. . . +55 ° Ordering Information FMC‑210‑SM‑G‑B Form G, Blue Single Action Call Point for indoor use, direct triggering (type A) FMC-210-SM-G-B FMC‑210‑SM‑G‑R Form G, Red Single Action Call Point for indoor use, direct triggering (type A) FMC-210-SM-G-R Accessories Pos. Description 1 Installation depth version 1: ca. 40 mm 2 Installation depth version 2: 14 mm 3 Installation depth version 3: min. 30 mm FMX‑FSO‑LSN Punched, Self-adhesive Foil Sets (Blank) For the labeling field of manual call points of the Series FMC‑210. 1 unit = 10 sheets FMX-FSO-LSN FMC‑FST‑DE Printed Labeling Foils for the Upper Label Field For yellow and blue manual call points of Series FMC‑120 and FMC‑210, 1 unit = 5 sheets FMC-FST-DE FMC‑SPGL‑DEIL Spare Glasses For manual call points of Series DM, DKM, SKM, FMC‑120 and FMC‑210. 1 unit = 5 spare glasses FMC-SPGL-DEIL Key for Fire Detectors Types G and H made of red plastic (ASA) FMM-KEY-Form G/H FMC‑210‑SM Single Action Call Points | 3 Ordering Information Sign with label "Nicht in Betrieb" Metal sign for fire detectors form G or H FMM-SIGN www.boschsecurity.com 4 | FMC‑210‑SM Single Action Call Points Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 [email protected] www.boschsecurity.com Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 [email protected] www.boschsecurity.us © Bosch Security Systems B.V. 2007 | Data subject to change without notice T3892227979 | Cur: en-US, V3, 13 Aug 2007 Asia-Pacific: Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone: +65 6319 3450 Fax: +65 6319 3499 [email protected] www.boschsecurity.com Represented by
© Copyright 2026 Paperzz