Honeywell SFL48 / SFU48

Connected Airport
Honeywell SFL48 / SFU48
LED-Approach Flash System
Main Characteristics
• Controller applicable for ALS1000 (CCR Cabinet)
• Controller compatible to SFU32 / SFL40 connector
• SFL48-IF LED-Inset Flash Light
• Avg. Light Beam >22kcd
• SFL48-EF LED-Elevated Flash Light
• Avg. Light Beam >22kcd
• No additional Cabling required
• No additional electronic in field
• Very high Life Cycle (>10 Years)
• Low Maintenance
Variants
• E900 Approach
• 600 Approach
• Option RETIL
• Only RETIL
• Elevated/Inset Lights
Standards and Regulations
• ICAO, Annex 14 (Date 2009)
• EASA, CS-ADR-DSN (Date 27.02.2014)
Fig. 1 SFL48 LED-Flash Light
Structure Approach Flash System
AGL Substation
Low-VoltageCabinet
ASL1000
CMS-System
Controller SFU48
(Available on site)
(Available on site)
Flash
No.31
Flash
No.1
Flash
No.2
Flash
No.3
Flash
No.4
Flash
No.5
Flash
No.6
Flash
No.26
Flash
No.27
Flash
No.28
Flash
No.29
Flash
No.30
Flash
No.32
Fig. 2 Connection Drawing
Fig. 3 Overview Connection Cable
1000M CABLE LENGTH
NYCWY 4x10RE/10
2000M CABLE LENGTH
NYCWY 4x16RE/16
3000M CABLE LENGTH
NYCWY 4x25RE/16
System Configuration (Examples)
31
900m Approach with SFL
1
5
10
15
20
25
30
32
600m Approach with SFL
1
5
10
15
31
20
32
Runway Edge Identification Lights only
31
32
Honeywell Airports Business
Brödermansweg 1
22453 Hamburg
Tel.: +49 (0) 40 61144-67
F
ax.: +49 SFL48
(0) 40 6Flash
1144-0Lights
6
Fig. 5 Dimensions
www.honeywellairports.com
Dok. Nr. 65 880 540-TD
Dimensions Flash-Lights
126mm
326mm
411mm
326mm
Fig. 5 Dimensions SFL48 Flash Lights
Technical Data – Light Measurement
ISOCANDELA MEASUREMENT LED-SFL (ELEVATED)
MINIMUM AVERAGE:
22.780,17 cd (Min. acc. To ICAO 20.000 cd)
MINIMUM MAIN BEAM:
12.282,33 cd (Min. acc. To ICAO 10.000 cd)
MINIMUM MIDDLE BEAM:
5197,15 cd (Min. acc. To ICAO 2.000 cd)
MINIMUM OUTER BEAM:
4410,57cd (Min. acc. To ICAO 1.000 cd)
Isocandela Diagram
Fig. 6 Isocandela Diagram ICAO Annex 14, Add. 2-1, Approach Lights
Technical Data – Light Measurement
ISOCANDELA MEASUREMENT LED-SFL (INSET)
MINIMUM AVERAGE
6.253,65 cd (Min. acc. to ICAO 5.000 cd)
MINIMUM MAIN BEAM
3.536,31 cd (Min. acc. to ICAO 2.500 cd)
MINIMUM MIDDLE BEAM
1.667,15 cd (Min. acc. to ICAO 500 cd)
MINIMUM OUTER BEAM
1.331,97 cd (Min. acc. to ICAO 250 cd)
Isocandela Diagram
Fig. 7 Isocandela Diagram ICAO Annex 14, Add. 2-6, Runway Centre Line Light
SFL48 / SFU48 Technical Specifications
TECHNICAL DATA – CONTROL UNIT SFU48
Supply Chain: 230 VAC
Frequency:50 Hz
Power input with maximum configuration:
Power used for flash lights: 905W
Power used for heating: 1600W
Fuses:
Phase 1: 20 A T
Phase 2: 10 A T
Control Voltages: 24 VDC
Output voltage: 230 VAC
Ambient temperature: -5°C - +55°C
Humidity: 95% (no condensation)
Cable diameter input: 5 x 10mm²
Cable diameter output:
Up to 1000m complete cable length: NYCWY
4x10RE/10
Up to 2000m complete cable length: NYCWY
4x16RE/16
Up to 3000m complete cable length: NYCWY
4x25RM/16
Sizes of Joint Connections:
Power Supply: M40, 15 – 23mm
Communication Line: M25, 6 – 13mm
Main Cable: M50, 22 – 29mm
Rating of back indication contacts:
Voltage/Currency/Power
220VDC/0,24A/60W
125VDC/0,24A/30W
30VDC/2A/60W
250VAC/0,25A/62,5VA
125VAC/0,5A/62,5VA
Protection class: IP 21
Dimensions: 19“, 3HE
Weight approximately: Ca. 5 kg
Colour: RAL 7035
TECHNICAL DATA – FLASH SFL48 (ELEVATED)
Supply voltage:
Flash: 230 V / 50 Hz
Heating: 230 V / 50 Hz
Ambient temperature: -40°C - +55°C
Humidity: 100% at 35°C
Protection class: IP 65
Dimensions (WxHxD): 326 x 411 x 126 mm
Weight approximately: 15 kg
Light Intensity (Avg.): >20.000 Cd
Vertical setting range :0° – 15°
Colour :RAL 1006
TECHNICAL DATA – FLASH SFL48 (INSET)
Supply voltage:
Flash: 230 V / 50 Hz
Ambient temperature: -40°C - +55°C
Humidity: 100% at 35°C
Protection class: IP 67
Dimensions (WxHxD): 326 x 411 x 126 mm
Weight approximately: 6,7 kg
Light Intensity (Avg.): >5.000 Cd
Vertical setting range :3,5°
Colour :Aluminium
For more information on these and other Honeywell Airport Systems products, visit
http://www.honeywellairports.com
Honeywell Airport Business
Americas
Europe & North Africa
Middle East, Indian Subcontinent & Central Africa
1985 Douglas Drive
North Golden Valley,
MN 55422-3992
Tel: 1.800.345.6770 ext.612
Broedermannsweg 1,
22453, Hamburg,
Germany
Phone: +49 40 61144-0
Fax: +49 40 611 44-06
Emaar Business Park Building 2, Level 2,
Office 201 P.O. Box 232362,
Sheikh Zayed Road
Dubai, UAE
Tel: +971 4 4540 685
Subject to alterations.
www.honeywell.com
Doc. Nr. 65 880 540-TD 01 | 08/16