Connected Airport Honeywell SFL48 / SFU48 LED-Approach Flash System Main Characteristics • Controller applicable for ALS1000 (CCR Cabinet) • Controller compatible to SFU32 / SFL40 connector • SFL48-IF LED-Inset Flash Light • Avg. Light Beam >22kcd • SFL48-EF LED-Elevated Flash Light • Avg. Light Beam >22kcd • No additional Cabling required • No additional electronic in field • Very high Life Cycle (>10 Years) • Low Maintenance Variants • E900 Approach • 600 Approach • Option RETIL • Only RETIL • Elevated/Inset Lights Standards and Regulations • ICAO, Annex 14 (Date 2009) • EASA, CS-ADR-DSN (Date 27.02.2014) Fig. 1 SFL48 LED-Flash Light Structure Approach Flash System AGL Substation Low-VoltageCabinet ASL1000 CMS-System Controller SFU48 (Available on site) (Available on site) Flash No.31 Flash No.1 Flash No.2 Flash No.3 Flash No.4 Flash No.5 Flash No.6 Flash No.26 Flash No.27 Flash No.28 Flash No.29 Flash No.30 Flash No.32 Fig. 2 Connection Drawing Fig. 3 Overview Connection Cable 1000M CABLE LENGTH NYCWY 4x10RE/10 2000M CABLE LENGTH NYCWY 4x16RE/16 3000M CABLE LENGTH NYCWY 4x25RE/16 System Configuration (Examples) 31 900m Approach with SFL 1 5 10 15 20 25 30 32 600m Approach with SFL 1 5 10 15 31 20 32 Runway Edge Identification Lights only 31 32 Honeywell Airports Business Brödermansweg 1 22453 Hamburg Tel.: +49 (0) 40 61144-67 F ax.: +49 SFL48 (0) 40 6Flash 1144-0Lights 6 Fig. 5 Dimensions www.honeywellairports.com Dok. Nr. 65 880 540-TD Dimensions Flash-Lights 126mm 326mm 411mm 326mm Fig. 5 Dimensions SFL48 Flash Lights Technical Data – Light Measurement ISOCANDELA MEASUREMENT LED-SFL (ELEVATED) MINIMUM AVERAGE: 22.780,17 cd (Min. acc. To ICAO 20.000 cd) MINIMUM MAIN BEAM: 12.282,33 cd (Min. acc. To ICAO 10.000 cd) MINIMUM MIDDLE BEAM: 5197,15 cd (Min. acc. To ICAO 2.000 cd) MINIMUM OUTER BEAM: 4410,57cd (Min. acc. To ICAO 1.000 cd) Isocandela Diagram Fig. 6 Isocandela Diagram ICAO Annex 14, Add. 2-1, Approach Lights Technical Data – Light Measurement ISOCANDELA MEASUREMENT LED-SFL (INSET) MINIMUM AVERAGE 6.253,65 cd (Min. acc. to ICAO 5.000 cd) MINIMUM MAIN BEAM 3.536,31 cd (Min. acc. to ICAO 2.500 cd) MINIMUM MIDDLE BEAM 1.667,15 cd (Min. acc. to ICAO 500 cd) MINIMUM OUTER BEAM 1.331,97 cd (Min. acc. to ICAO 250 cd) Isocandela Diagram Fig. 7 Isocandela Diagram ICAO Annex 14, Add. 2-6, Runway Centre Line Light SFL48 / SFU48 Technical Specifications TECHNICAL DATA – CONTROL UNIT SFU48 Supply Chain: 230 VAC Frequency:50 Hz Power input with maximum configuration: Power used for flash lights: 905W Power used for heating: 1600W Fuses: Phase 1: 20 A T Phase 2: 10 A T Control Voltages: 24 VDC Output voltage: 230 VAC Ambient temperature: -5°C - +55°C Humidity: 95% (no condensation) Cable diameter input: 5 x 10mm² Cable diameter output: Up to 1000m complete cable length: NYCWY 4x10RE/10 Up to 2000m complete cable length: NYCWY 4x16RE/16 Up to 3000m complete cable length: NYCWY 4x25RM/16 Sizes of Joint Connections: Power Supply: M40, 15 – 23mm Communication Line: M25, 6 – 13mm Main Cable: M50, 22 – 29mm Rating of back indication contacts: Voltage/Currency/Power 220VDC/0,24A/60W 125VDC/0,24A/30W 30VDC/2A/60W 250VAC/0,25A/62,5VA 125VAC/0,5A/62,5VA Protection class: IP 21 Dimensions: 19“, 3HE Weight approximately: Ca. 5 kg Colour: RAL 7035 TECHNICAL DATA – FLASH SFL48 (ELEVATED) Supply voltage: Flash: 230 V / 50 Hz Heating: 230 V / 50 Hz Ambient temperature: -40°C - +55°C Humidity: 100% at 35°C Protection class: IP 65 Dimensions (WxHxD): 326 x 411 x 126 mm Weight approximately: 15 kg Light Intensity (Avg.): >20.000 Cd Vertical setting range :0° – 15° Colour :RAL 1006 TECHNICAL DATA – FLASH SFL48 (INSET) Supply voltage: Flash: 230 V / 50 Hz Ambient temperature: -40°C - +55°C Humidity: 100% at 35°C Protection class: IP 67 Dimensions (WxHxD): 326 x 411 x 126 mm Weight approximately: 6,7 kg Light Intensity (Avg.): >5.000 Cd Vertical setting range :3,5° Colour :Aluminium For more information on these and other Honeywell Airport Systems products, visit http://www.honeywellairports.com Honeywell Airport Business Americas Europe & North Africa Middle East, Indian Subcontinent & Central Africa 1985 Douglas Drive North Golden Valley, MN 55422-3992 Tel: 1.800.345.6770 ext.612 Broedermannsweg 1, 22453, Hamburg, Germany Phone: +49 40 61144-0 Fax: +49 40 611 44-06 Emaar Business Park Building 2, Level 2, Office 201 P.O. Box 232362, Sheikh Zayed Road Dubai, UAE Tel: +971 4 4540 685 Subject to alterations. www.honeywell.com Doc. Nr. 65 880 540-TD 01 | 08/16 © 2016 Honeywell International Inc.
© Copyright 2026 Paperzz