- Ontario.ca

ONTARIO REGULATION 13/12
made under the
GREEN ENERGY ACT, 2009
Made: February 14, 2012
Filed: February 17, 2012
Published on e-Laws: February 21, 2012
Printed in The Ontario Gazette: March 03, 2012
Amending O. Reg. 82/95
(GENERAL)
1. Section 2 of Ontario Regulation 82/95 is amended by adding the following subsection:
(3) In items 62 to 65 of the Schedule, “general service lamp” and “modified spectrum lamp” have the same meaning as in
SOR/94-651 (Energy Efficiency Regulations) made under the Energy Efficiency Act (Canada) as they read on January 1,
2012.
2. Section 3 of the Regulation is amended by striking out “For the purpose of clause 3 (3) (a) of the Act” at the
beginning and substituting “For the purpose of clause 15 (3) (a) of the Act”.
3. (1) Subsection 5 (1) of the Regulation is amended by striking out “For the purpose of clause 3 (1) (b) of the Act”
at the beginning and substituting “For the purpose of clause 15 (1) (b) of the Act”.
(2) Subsection 5 (3) of the Regulation is amended by striking out “is exempt from clause 3 (1) (b) of the Act” in the
portion before clause (a) and substituting “is exempt from clause 15 (1) (b) of the Act”.
(3) Subsection 5 (4) of the Regulation is amended by striking out “is exempt from clause 3 (1) (b) of the Act” in the
portion before clause (a) and substituting “is exempt from clause 15 (1) (b) of the Act”.
4. The Schedule to the Regulation is amended by adding the following items:
Column 1
62. General service lamps — excluding
modified spectrum lamps — with a
lumen output of at least 1,050 lumens
but not more than 2,600 lumens.
Column 2
For lamp lumen output and
wattage: IES LM-45-00
(IESNA Approved Method
for Electrical and
Photometric Measurements
of General Service
Incandescent Filament
Lamps), except that it must
be tested at 120 volts
regardless of its nominal
voltage
Column 3
Column 4
Lamp efficacy in lumens per January 1, 2014
watt: ≥ 4.0357 x ln (lumen)
– 7.1345
For life: IES LM-49-01
(IESNA Approved Method
for Life Testing of General
Lighting Incandescent
Filament Lamps), except
that it must be tested at 120
volts regardless of its
nominal voltage
Life: ≥ 1,000 hours
For colour rendering index
(CRI): CIE 13.3-95
(Method of Measuring and
Specifying Colour
Rendering Properties of
Light Sources)
Colour rendering index: ≥
80
2
63. General service lamps that are modified
spectrum lamps with a lumen output of
at least 1,050 lumens but not more than
2,600 lumens.
64. General service lamps — excluding
modified spectrum lamps — with a
lumen output of at least 250 lumens but
less than 1,050 lumens.
65. General service lamps that are modified
spectrum lamps with a lumen output of
at least 250 lumens but less than 1,050
lumens.
For lamp lumen output and
wattage: IES LM-45-00
(IESNA Approved Method
for Electrical and
Photometric Measurements
of General Service
Incandescent Filament
Lamps), except that it must
be tested at 120 volts
regardless of its nominal
voltage
Lamp efficacy in lumens per January 1, 2014
watt: ≥ 75 per cent of the
efficacy of the standard
spectrum lamp
For life: IES LM-49-01
(IESNA Approved Method
for Life Testing of General
Lighting Incandescent
Filament Lamps), except
that it must be tested at 120
volts regardless of its
nominal voltage
Life: ≥ 1,000 hours
For colour rendering index
(CRI): CIE 13.3-95
(Method of Measuring and
Specifying Colour
Rendering Properties of
Light Sources)
Colour rendering index: ≥
80
For lamp lumen output and
wattage: IES LM-45-00
(IESNA Approved Method
for Electrical and
Photometric Measurements
of General Service
Incandescent Filament
Lamps), except that it must
be tested at 120 volts
regardless of its nominal
voltage
Lamp efficacy in lumens per December 31, 2014
watt: ≥ 4.0357 x ln (lumen)
– 7.1345
For life: IES LM-49-01
(IESNA Approved Method
for Life Testing of General
Lighting Incandescent
Filament Lamps), except
that it must be tested at 120
volts regardless of its
nominal voltage
Life: ≥ 1,000 hours
For colour rendering index
(CRI): CIE 13.3-95
(Method of Measuring and
Specifying Colour
Rendering Properties of
Light Sources)
Colour rendering index: ≥
80
For lamp lumen output and
wattage: IES LM-45-00
(IESNA Approved Method
for Electrical and
Photometric Measurements
of General Service
Incandescent Filament
Lamps), except that it must
be tested at 120 volts
regardless of its nominal
voltage
Lamp efficacy in lumens per December 31, 2014
watt: ≥ 75 per cent of the
efficacy of the standard
spectrum lamp
3
For life: IES LM-49-01
(IESNA Approved Method
for Life Testing of General
Lighting Incandescent
Filament Lamps), except
that it must be tested at 120
volts regardless of its
nominal voltage
Life: ≥ 1,000 hours
For colour rendering index
(CRI): CIE 13.3-95
(Method of Measuring and
Specifying Colour
Rendering Properties of
Light Sources)
Colour rendering index: ≥
80
Commencement
5. This Regulation comes into force on the later of the following days:
1. July 1, 2012.
2. The day this Regulation is filed.
Back to top