BoxRayz® 400 Constant Current LED Power Supply

BoxRayz® 400
Constant Current LED Power Supply
PS0700-150W-100-277V-2O
Features and Benefits
• Class 2 dual output channels for powering two strings of LED modules
• On Primary side, ½" NPT thread connector for easy AC electrical wiring
• On Secondary side, cable and connectors for directly plugging into LED modules
• Wide AC voltage input range 100-277V 50/60Hz
• 0-10V dimming control
• Active Power Factor Correction (0.99 Typical)
• Operating temperature -40°C to +60°C (-40°F to +140°F)
• Surge, over-voltage, over-current, over-temperature and short-circuit protections
• IP67 Rating - UL certified for use in damp and dry locations
• Compliant with FCC Title 47 CFR Part 15, ANSI C63.4: 2009 Class B
• 5-year limited warranty
Ordering Information (subject to change without notice)
Ordering Code
Input
Voltage
(VAC)
Output
Voltage
(VDC)
# of Output
Current
Channels
Output Current
1
per Channel
(ADC)
Max.
Output
Power (W)
1.4
150
24-54
100-277
2
PS0700-150W-100-277V-2O
Notes:
(1) Measured with full load at rated AC input voltage.
(2) For case temperature ≤68°C;
Case temperature shall not exceed 90°C in application.
0700
Output Current
Typical
Power Factor
120VAC 220VAC
0.99
0.95
Average
2
Rated
Life
50,000 hours
Net
Weight
(lb)/(kg)
2.95/1.34
LED Module to Power Supply
Wire Size
Ordering Guide
PS
Power Supply
Typical
1
Efficiency
120VAC 220VAC
88%
91%
-150W
-100-277V
-2O
Max. Output Wattage Input Voltage Range 2 Outputs Channels
Wire Size
Metric
Gauge
2
(mm )
(AWG)
26
0.13
24
0.21
22
0.33
20
0.52
18
0.82
16
1.31
14
2.08
12
3.31
10
5.26
Maximum Distance*
Feet
Meters
3
4
7
11
18
29
45
71
120
0.9
1.2
2.1
3.4
5.5
8.8
13.7
21.6
36.6
*Di s ta nce from power s uppl y to l oa d a t ful l ca pa ci ty
Safety Category
Country
Standard
CUL
USA & Canada
UL8750 Compliance to UL1310 Class2, UL1012
CSA-C22.2 No. 107.1, CSA-C22.2 No. 223-M91 Class2
Europe
EN61347- 1, EN61347- 2-13:2006
CE
EMI Standards
Notes
EN 55015
Conducted emission Test & Radiated emission Test with 6 dB margin
EN 61000-3-2
Harmonic current emissions: Class C
EN 61000-3-3
Voltage fluctuations & flicker
EN 61000-4-2
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4
Electrical Fast Transient / Burst-EFT
EN 61000-4-5
Surge Immunity Test: AC Power Line: line to line 2 kV, line to earth 4 kV
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8
Power Frequency Magnetic Field Test
EN 61000-4-11
Voltage Dips
EN 61547
Electromagnetic Immunity Requirements Applies to Lighting Equipment
Shipping Information
Ordering Code
PS0700-150W-100-277V-2O
General LED, Inc. +1.866.482.0203
SKU
Case
Quantity
SKU Weight
(lb/kg)
Case Weight
(lb/kg)
SKU Dimensions
(W x D x H)
Case Dimensions
(W x D x H)
1 unit/SKU
12 SKUs/Box
2.95
1.34
41.0
18.6
8.35”x3.39”x1.50”
212x86x38mm
19.7”x14.6”x13.2”
500x370x335mm
www.AgiLight.com
www.GenLEDLighting.com
© 2014 General LED, Inc. 2014 All rights reserved.
Product Specifications subject to change without notice. 8-2014
BoxRayz® 400
Constant Current LED Power Supply
PS0700-150W-100-277V-2O
Mechanical Outline
17.0 in
431.8 mm
0.91 in
23 mm
DC OUTPUT(2*Constant Current Channels)
BLACK (ACL)
WHITE (ACN)
GREEN (GND)
1.97 in
50 mm 2.56 in
3.15 in 65 mm
80 mm
1.50 in
38 mm
25.59 in
650 mm
8.35 in
212 mm
7.87 in
200 mm
1.42 in
36 mm
0.59 in
15 mm
GRAY
PURPLE
BLACK & WHITE
3.46 in
88 mm
7.24 in
184 mm
AC INPUT(3*AWG #18)
3.39 in
86 mm
7.40 in
188 mm
Note: UL 48 Standard requires spacings between transformers, ballasts, neon power supplies and LED power
supplies shall be at least 1 inch (25.4 mm) from end to end and 4 inches (101.6 mm) from side to side.
N
G
Vac
CC Channel 1
LED Load
CC Channel 2
LED Load
Vaux(BLK/WHT)
Dim+(PUR)
Dim-(GRY)
250kΩ
Potentiometer
0-10VDC
Dimmer
Output Current vs. Dimming Voltage
100%
Normalized Output Current
L
PS0700-150W-100-277V-2O
LED Power Supply
Dimming Controls
WARNING
Connecting to AC line voltage
BEFORE connecting the LED
modules to the power supply
will DAMAGE the system and
VOID the WARRANTY.
80%
60%
40%
20%
0%
0
1
2 3 4 5 6
Dimming Voltage (V)
7
8
Notes:
1. For the power supply to operate properly, the load voltage must be maintained above
the rated minimum voltage.
Power Supply
2. If the output voltage is maintained above rated minimum voltage, the dimming control
may be operated over the entire 0-10V range with output current varying from 10% to
PS0700-150W-100-277-2O
100% of the Rated Current.
3. The dimmer may be operated using either a potentiometer or an input signal of 0-10 Vdc.
9
10
Power Supply Load Chart
General LED, Inc.
1074 Arion Circle, Ste 116
San Antonio, TX 78216
United States of America
+1.866.482.0203
General LED Fze
822, Building 4EA
Dubai Airport Free Zone
Dubai, United Arab Emirates
+971 4 7017901822
www.AgiLight.com
www.GenLEDLighting.com
www.GeneralLED.com
General LED, Inc. +1.866.482.0203
www.AgiLight.com
www.GenLEDLighting.com
# of Modules/ Power Supply
Output Single Channel
Usage
Voltage
24-54V
9 to 16
Double Channel Usage
(8 to 16)/Channel
(16 to 32) Total
CAUTIONS
1. The maximum case temperature shall not exceed
90ºC when used in end product.
2. These products are intended to be connected to a
max. 20 A branch circuit.
3. These products are intended for use in dry, damp
and wet locations.
© 2014 General LED, Inc. 2014 All rights reserved.
Product Specifications subject to change without notice. 8-2014