Attic venting shall provide 1 square foot (SF) opening for each 150 SF of area. Or, 1 SF per 300 SF of area if 40-50% are within 3' of roof ridge with remainder as eave/soffit vents R806.2 U .30 min. Grade to drain away from the foundation. 6" of fall within first 10 feet. R401.3 1 of 7 B15-1594 08/20/2015 By EVA CHRISTEL at 8:54 am, Aug 27, 2015 2 of 7 B15-1594 08/20/2015 3 of 7 B15-1594 08/20/2015 24" deep 4 of 7 B15-1594 08/20/2015 5 of 7 B15-1594 08/20/2015 CO Carbon monoxide alarms must be installed outside each sleeping (or with closet) area. One per dwelling level. 100 cfm fan SD SD/CO 24" PFH 32" min ABW 6 of 7 B15-1594 08/20/2015 2-story dwelling footers will be 15" wide, min. concrete and located below frost level of 24" R403.1 2" rigid foam R-10 insulation 24" high located on heated sides of slab foundations. 7 of 7 B15-1594 08/20/2015 Attic venting shall provide 1 square foot (SF) opening for each 150 SF of area. Or, 1 SF per 300 SF of area if 40-50% are within 3' of roof ridge with remainder at soffits Weather resistive barrier Vapor barrier Ice shield is not required H1, H2.5 or equal @ each truss, each end