List of notes – Engine Order form Order form The order form is intended for use when ordering parameter adjustments from a Scania workshop equipped with SDP3. Ordered by/contact person Remarks/other Date Company Name Telephone Vehicle Type designation (e.g. R580 LB6x2) Registration number Chassis serial number 11:70-02/01 Issue 4 en-GB 1 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes List of notes Note: This is a comprehensive list. The parameters and settings that are available on the vehicle depend on the vehicle specification. The parameters are described in more detail in the document Adjustable parameters - Engine Remote engine start control Parameter Remote engine start Verification period during remote engine start Selection of signal input for remote engine start Possible value With flashing Without flashing Without 0–5 s Active high External CAN Desired value Possible value Desired value Comments ECU BWS BWS BWS Monitored remote engine shutdown Parameter Monitored remote engine shutdown Selection of signal input for monitored remote engine shutdown Vehicle speed conditions for monitored remote engine shutdown None Checks Without Active low External CAN 1-20 km/h in increments of 1 km/h 11:70-02/01 Issue 4 en-GB Comments ECU BWS BWS EMS 2 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Torque limiter Parameter Selection of signal input for torque limiter 1, 2 or 3 Own torque curve – Torque limiter 3 Possible value Desired value Comments Active low External CAN 0– (engine-dependent value) Nm in increments of 20 Nm ECU BWS EMS Remote hand throttle Parameter Possible value Selection of signal input for hand throttle control (mode 0, mode 1, Active low mode 2 and mode 4) External CAN 11:70-02/01 Issue 4 en-GB Desired value Comments ECU BWS 3 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Limited hand throttle (mode 1) and for pre-defined engine speed (mode 3) (locked) Parameter Possible value Selection of signal input for limited hand throttle (mode 1) and for Active low pre-defined engine speed (mode 3) (locked) External CAN Engine speed with limited hand throttle (mode 1) S6 – 500–2,000 rpm in increments of 50 rpm S7 – 500–2,000 rpm in increments of 10 rpm S8 – 500–2,000 rpm in increments of 10 rpm Use of accelerator pedal with limited hand throttle (mode 1) Active Inactive Maximum engine speed with limited hand throttle (mode1) S6 – 700–2,000 rpm in increments of 50 rpm S7 – 500–2,000 rpm in increments of 10 rpm S8 – 500–2,000 rpm in increments of 10 rpm Maximum torque with limited hand throttle (mode 1) S6 – 300–(engine-dependent value) Nm in increments of 20 Nm S7 – 300–(engine-dependent value) Nm in increments of 10 Nm S8 – 300–(engine-dependent value) Nm in increments of 10 Nm 11:70-02/01 Issue 4 en-GB Desired value Comments ECU COO EMS EMS EMS EMS 4 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Raised idling speed (mode 2) and for pre-defined engine speed (mode 3) (locked) Parameter Selection of signal input for raised idling speed (mode 2) and for pre-defined engine speed (mode 3) (locked) Engine speed at raised idling speed (mode 2) Possible value Desired value Comments Active low External CAN S6 – 500–2,000 rpm in increments of 50 rpm S7 – 500–2,000 rpm in increments of 10 rpm S8 – 500–2,000 rpm in increments of 10 rpm ECU BWS EMS Pre-defined engine speed (mode 3) (locked) Parameter Engine speed at pre-defined engine speed (mode 3) (locked) Possible value S6 – 600–2,000 rpm in increments of 50 rpm S7 – 500–800 rpm in increments of 10 rpm S8 – 500–800 rpm in increments of 10 rpm Maximum torque with pre-defined engine speed (mode 3) (locked) S6 – 300-(engine-dependent value) Nm in increments of 20 Nm S7 – 300-(engine-dependent value) Nm in increments of 10 Nm S8 – 300-(engine-dependent value) Nm in increments of 10 Nm 11:70-02/01 Issue 4 en-GB Desired value Comments ECU EMS EMS 5 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Remote engine speed control (mode 4) Parameter Possible value Selection of signal input for engine speed control 1 and 2 (mode 4) Active high External CAN Selection of governor characteristics for engine speed control 1 and Soft 2 (mode 4) Hard Type of control during engine speed control 1 (mode 4) Fixed Hand throttle control Size of increment during engine speed control 1 (mode 4) 10–250 rpm in increments of 10 rpm Switching off increase in engine speed during engine speed control With 1 and 2 (mode 4) Without Increase in engine speed during engine speed control 1 and 2 (mode 100–1,000 rpm/second in increments of 4) 100 rpm/(second) Type of control during engine speed control 2 (mode 4) Without Fixed Analogue External CAN Lower voltage limit for the potentiometer during engine speed con- 0.5–1.0 in increments of 0.1 V trol 2 Upper voltage limit for the potentiometer during engine speed con- 2.0–4.5 V in increments of 0.5 V trol 2 Fixed engine speed during engine speed control 1 (mode 4) 600–2,000 rpm in increments of 50 rpm Fixed engine speed during engine speed control 2 (mode 4) 600–2,000 rpm in increments of 50 rpm 600–2,000 rpm in increments of 50 rpm Gear change engine speed for automatic gearbox during engine speed control 1 and 2 (mode 4) Lower engine speed limit during engine speed control 1 and 2 600–2,000 rpm in increments of 50 rpm (mode 4) 11:70-02/01 Issue 4 en-GB Desired value Comments ECU BWS BWS BWS BWS BWS BWS BWS BWS BWS BWS BWS BWS BWS 6 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Parameter Upper engine speed limit during engine speed control 1 and 2 (mode 4) Vehicle speed conditions during engine speed control 1 and 2 (mode 4) Possible value 600–2,000 rpm in increments of 50 rpm Desired value Comments None Stationary 5-50 km/h in increments of 5 km/h Maximum torque during engine speed control 1 and 2 (mode 4) S6 – 300–(engine-dependent value) Nm in increments of 20 Nm S7 – 300–(engine-dependent value) Nm in increments of 10 Nm S8 – 300–(engine-dependent value) Nm in increments of 10 Nm Maximum engine speed while braking during engine speed control S6 – 600–1,500 rpm in increments of 50 1 and 2 (mode 4) rpm S7 – 500–2,000 rpm in increments of 10 rpm S8 – 500–2,000 rpm in increments of 10 rpm Maximum speed for engine speed control 1 and 2 (mode 4) 0-150 km/h in increments of 1 km/h ECU BWS BWS EMS EMS EMS Constant engine speed limitation Parameter Engine speed at constant engine speed limitation Selection of signal input for remote engine speed limiter Possible value 500-3,000 rpm Without Active low External CAN 11:70-02/01 Issue 4 en-GB Desired value Comments ECU EMS BWS 7 (8) © Scania CV AB 2013, Sweden List of notes – Engine List of notes Other engine speed parameters Parameter Rotational speed control with gear engaged (modes 0–4) Possible value Desired value Comments ECU EMS Possible value 500–700 rpm Desired value Comments ECU EMS Possible value RQV - Manual RQ - Automatic Without With Desired value Comments ECU EMS Yes No Idling speed Parameter Idling speed adjustment Other parameters Parameter Control of accelerator pedal characteristics Engine speed limitation 11:70-02/01 Issue 4 en-GB EMS 8 (8) © Scania CV AB 2013, Sweden
© Copyright 2026 Paperzz