This is a comprehensive list. The parameters and settings that are available on the vehicle depend on the vehicle specification.
The parameters are described in more detail in the document Adjustable parameters
- Engine
Remote engine start control
Parameter
Remote engine start
Verification period during remote engine start
Selection of signal input for remote engine start
Possible value
With flashing
Without flashing
Without
0–5 s
Active high
External CAN
Desired value
Possible value
Desired value
Comments
ECU
BWS
BWS
BWS
Monitored remote engine shutdown
Parameter
Monitored remote engine shutdown
Selection of signal input for monitored remote engine shutdown
Vehicle speed conditions for monitored remote engine shutdown
None
Checks
Without
Active low
External CAN
1-20 km/h in increments of 1 km/h
11:70-02/01 Issue 4 en-GB
Comments
ECU
BWS
BWS
EMS
2 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Torque limiter
Parameter
Selection of signal input for torque limiter 1, 2 or 3
Own torque curve – Torque limiter 3
Possible value
Desired value
Comments
Active low
External CAN
0– (engine-dependent value) Nm in increments of 20 Nm
ECU
BWS
EMS
Remote hand throttle
Parameter
Possible value
Selection of signal input for hand throttle control (mode 0, mode 1, Active low
mode 2 and mode 4)
External CAN
11:70-02/01 Issue 4 en-GB
Desired value
Comments
ECU
BWS
3 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Limited hand throttle (mode 1) and for pre-defined
engine speed (mode 3) (locked)
Parameter
Possible value
Selection of signal input for limited hand throttle (mode 1) and for Active low
pre-defined engine speed (mode 3) (locked)
External CAN
Engine speed with limited hand throttle (mode 1)
S6 – 500–2,000 rpm in increments of 50
rpm
S7 – 500–2,000 rpm in increments of 10
rpm
S8 – 500–2,000 rpm in increments of 10
rpm
Use of accelerator pedal with limited hand throttle (mode 1)
Active
Inactive
Maximum engine speed with limited hand throttle (mode1)
S6 – 700–2,000 rpm in increments of 50
rpm
S7 – 500–2,000 rpm in increments of 10
rpm
S8 – 500–2,000 rpm in increments of 10
rpm
Maximum torque with limited hand throttle (mode 1)
S6 – 300–(engine-dependent value) Nm
in increments of 20 Nm
S7 – 300–(engine-dependent value) Nm
in increments of 10 Nm
S8 – 300–(engine-dependent value) Nm
in increments of 10 Nm
11:70-02/01 Issue 4 en-GB
Desired value
Comments
ECU
COO
EMS
EMS
EMS
EMS
4 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Raised idling speed (mode 2) and for pre-defined
engine speed (mode 3) (locked)
Parameter
Selection of signal input for raised idling speed (mode 2) and for
pre-defined engine speed (mode 3) (locked)
Engine speed at raised idling speed (mode 2)
Possible value
Desired value
Comments
Active low
External CAN
S6 – 500–2,000 rpm in increments of 50
rpm
S7 – 500–2,000 rpm in increments of 10
rpm
S8 – 500–2,000 rpm in increments of 10
rpm
ECU
BWS
EMS
Pre-defined engine speed (mode 3) (locked)
Parameter
Engine speed at pre-defined engine speed (mode 3) (locked)
Possible value
S6 – 600–2,000 rpm in increments of 50
rpm
S7 – 500–800 rpm in increments of 10
rpm
S8 – 500–800 rpm in increments of 10
rpm
Maximum torque with pre-defined engine speed (mode 3) (locked) S6 – 300-(engine-dependent value) Nm
in increments of 20 Nm
S7 – 300-(engine-dependent value) Nm
in increments of 10 Nm
S8 – 300-(engine-dependent value) Nm
in increments of 10 Nm
11:70-02/01 Issue 4 en-GB
Desired value
Comments
ECU
EMS
EMS
5 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Remote engine speed control (mode 4)
Parameter
Possible value
Selection of signal input for engine speed control 1 and 2 (mode 4) Active high
External CAN
Selection of governor characteristics for engine speed control 1 and Soft
2 (mode 4)
Hard
Type of control during engine speed control 1 (mode 4)
Fixed
Hand throttle control
Size of increment during engine speed control 1 (mode 4)
10–250 rpm in increments of 10 rpm
Switching off increase in engine speed during engine speed control With
1 and 2 (mode 4)
Without
Increase in engine speed during engine speed control 1 and 2 (mode 100–1,000 rpm/second in increments of
4)
100 rpm/(second)
Type of control during engine speed control 2 (mode 4)
Without
Fixed
Analogue
External CAN
Lower voltage limit for the potentiometer during engine speed con- 0.5–1.0 in increments of 0.1 V
trol 2
Upper voltage limit for the potentiometer during engine speed con- 2.0–4.5 V in increments of 0.5 V
trol 2
Fixed engine speed during engine speed control 1 (mode 4)
600–2,000 rpm in increments of 50 rpm
Fixed engine speed during engine speed control 2 (mode 4)
600–2,000 rpm in increments of 50 rpm
600–2,000 rpm in increments of 50 rpm
Gear change engine speed for automatic gearbox during engine
speed control 1 and 2 (mode 4)
Lower engine speed limit during engine speed control 1 and 2
600–2,000 rpm in increments of 50 rpm
(mode 4)
11:70-02/01 Issue 4 en-GB
Desired value
Comments
ECU
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
BWS
6 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Parameter
Upper engine speed limit during engine speed control 1 and 2
(mode 4)
Vehicle speed conditions during engine speed control 1 and 2
(mode 4)
Possible value
600–2,000 rpm in increments of 50 rpm
Desired value
Comments
None
Stationary
5-50 km/h in increments of 5 km/h
Maximum torque during engine speed control 1 and 2 (mode 4)
S6 – 300–(engine-dependent value) Nm
in increments of 20 Nm
S7 – 300–(engine-dependent value) Nm
in increments of 10 Nm
S8 – 300–(engine-dependent value) Nm
in increments of 10 Nm
Maximum engine speed while braking during engine speed control S6 – 600–1,500 rpm in increments of 50
1 and 2 (mode 4)
rpm
S7 – 500–2,000 rpm in increments of 10
rpm
S8 – 500–2,000 rpm in increments of 10
rpm
Maximum speed for engine speed control 1 and 2 (mode 4)
0-150 km/h in increments of 1 km/h
ECU
BWS
BWS
EMS
EMS
EMS
Constant engine speed limitation
Parameter
Engine speed at constant engine speed limitation
Selection of signal input for remote engine speed limiter
Possible value
500-3,000 rpm
Without
Active low
External CAN
11:70-02/01 Issue 4 en-GB
Desired value
Comments
ECU
EMS
BWS
7 (8)
©
Scania CV AB 2013, Sweden
List of notes – Engine
List of notes
Other engine speed parameters
Parameter
Rotational speed control with gear engaged (modes 0–4)
Possible value
Desired value
Comments
ECU
EMS
Possible value
500–700 rpm
Desired value
Comments
ECU
EMS
Possible value
RQV - Manual
RQ - Automatic
Without
With
Desired value
Comments
ECU
EMS
Yes
No
Idling speed
Parameter
Idling speed adjustment
Other parameters
Parameter
Control of accelerator pedal characteristics
Engine speed limitation
11:70-02/01 Issue 4 en-GB