NetDX 2 Doors Controller Installation Guide

NetDX 2 Doors Controller
Installation Guide
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
TABLE OF CONTENTS
Mounting ......................................................................................................................... 3
Wiring .............................................................................................................................. 3
The NetDX Terminal Connectors Description ................................................................. 4
Network Connections ..................................................................................................... 6
Relay /Door Connections ................................................................................................ 7
Reader Types and Connections....................................................................................... 7
RTE and Door Switch Inputs ............................................................................................ 8
Addressing ....................................................................................................................... 9
Complementary Devices ............................................................................................... 11
Technical Specifications ................................................................................................ 12
Physical Characteristics .................................................................................................13
License and Limited Warranty Agreement ................................................................... 14
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Mounting
The NetDX is an intelligent two-door access Controller. The NetDx provides card holder and event memory,
communication channels, real time clock, protects inputs, power source and dry contact outputs. Up to 64 NetDx
controllers can be connected on one line wire via RS485 bus. It has a built in memory for 5,000 cards and has
access to 100,000 cards by communicating over the RS485. It is programmed from the PC Gatekeeper software via
the USB port using a RS485 adaptor.
Picture 1: The NetDX Controller
Wiring
All terminal blocks are detachable. You may find it easier to attach wires to the detached terminal blocks while is
not connected to the controller. Use an appropriate screwdriver to open the desired terminal and then insert the
wire into the hole. Once the wire is in all the way, turn the screwdriver clockwise to lock the wire into place. The
wire should have about 10mm of stripped off section to be held by the terminal. You may quite easily insert more
than one wire into a single terminal. The Connectors are shown below:
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
AC/DC
Power IN
Bat.
Backup
Address& Functions
Dip Switch
I/O Exp
Door 2
Door 1
RS232
Power
Out
Aux.
Inputs
RS485
Picture 2: The NetDX Connections Layout
The NetDX Terminal Connectors Description
Terminal list:
Connector
Bat Backup
Terminal
Description
+
Connects the Battery Positive led to Controller
-
Connects the Battery Negative led to Controller
Power In
You can connect 15-17V ,AC or DC (no polarity consideration is mandatory).
You can connect 15-17V ,AC or DC (no polarity consideration is mandatory).
I/O Expansion
Door 2
Com
Expiation Relay Module Common terminal
Gnd
Expiation Relay Module Ground terminal
Vout
Expiation Relay Module Power terminal
Vrdr
Power output to reader (+12Vdc or +5Vdc depending on jumper)
Gnd
Common ground to reader
LED
Reader LED control output
D0
Wiegand D0 or ABA Clock input
D1
Wiegand D1 or ABA Data input
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Req. to Exit
(Door2)
Door Relay
(Door2)
Aux relay
(Door2)
RTE
Request to exit button input. Tie other wire to ground terminal.
GND
Input common ground.
DPOS
Door position reed relay input. Tie other wire to ground terminal.
D2NO
Lock normally open relay terminal
GND
Lock common relay terminal
D2NC
Lock normally closed relay terminal
X2NO
Auxiliary relay normally open terminal
X2C
X2NC
Aux Inputs
Aux Power Out
NA
Gnd
NA
In2
NA
In3
NA
Gnd
NA
In4
NA
5V
5VDC output
Vout
NA
Gnd
Common Ground
Gnd
+12 VDC
RS485 A terminal. Connect between all controllers and NetIOX (I/O Expender).
RX
Terminal
X2NO
X2C
Door Relay
(Door1)
Common ground. Must be connected between all units.
Receiving Port
Ground
Transmitting Port
Description
Auxiliary relay normally open terminal
Auxiliary relay common terminal
X2NC
Auxiliary relay normally closed terminal
D1NO
Lock normally open relay terminal
D1C
D1NC
Req. to Exit
+12VDC output
A
TX
Aux relay
(Door1)
Common Ground
RS485 B terminal. Connect between all controllers and NetIOX(I/O Expender).
GND
Connector
+12VDC output
B
Gnd
RS232
Auxiliary relay normally closed terminal
In 1
+12 VDC
RS485
Auxiliary relay common terminal
RTE
Lock common relay terminal
Lock normally closed relay terminal
Request to exit button input. Tie other wire to ground terminal.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
(Door1)
Door 1
GND
Input common ground.
DPOS
Door position reed relay input. Tie other wire to ground terminal.
Vrdr
Power output to reader (+12Vdc or +5Vdc depending on jumper)
Gnd
Common ground to reader
LED
Reader LED control output
D0
Wiegand D0 or ABA Clock input
D1
Wiegand D1 or ABA Data input
Table 1: Connectors Wiring
Network Connections
Connecting two or more NetDX units requires three wires between the units, as follows:
1.
2.
3.
Use a twisted pair between terminal A of all units and B of all units.
Connect a common ground wire between all terminals.
Connect the RS485 wires to the USB adaptor and connect to the PC USB port.
1V
2
B
+
RS485
Gnd
B
Up to 64
Controllers
A
USB/RS485
Converter
Picture 3: Controller/s communications connections
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Relay /Door Connections
Locks are either normally powered (magnetic lock) or supplied power only for opening (electric strike). Connect the
lock with its power supply through relay common (DC) + DNO (strike) or relay common + DNC (magnetic lock), as
shown below:
DNO
DC
DC
DNC
Lock power
supply
Lock power
supply
Mag
lock
Picture4: Lock power connections
Reader Types and Connections
The NetDX can accommodate two types of readers:


Magnetic card readers (ABA clock/data)
Wiegand output readers (D0, D1)
Wiegand reader connections:
Magnetic card reader connections:
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Function
Terminal
Function
Terminal
Ground
Gnd
Ground
Gnd
Power
Vrdr
Power
Vrdr
Green LED
LED
Green LED
LED
Data 0
D0
Clock
D0
Data 1
D1
Data
D1
Note: Make sure to set the Reader Power selector/jumper named Vrdr Jumper as following:
1.
2.
12VDC (jumper on 1 and 2 Pins) for Wiegand Readers
5 VDC (jumper on 2 and 3 Pins) for ABA Magnetic readers
12V
Ground
LED control
Data 0
Data 1
Picture 5: Wiegand reader wiring
RTE and Door Switch Inputs
A door installation may require a Request to Exit (RTE) button and/or door position switch.
Connect the inputs as shown below:
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Door open
button
Door
position
Picture 6: Door switches
Addressing
The NetDX occupies TWO door addresses, of which the first is defined by the DIP switches on the DX. The first door
may be on an even or odd address. Make sure you do not cause an overlap between controllers.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
1
2
3
4
5
6
7
8
33
34
35
36
37
38
39
40
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
9
10
11
12
13
14
15
16
41
42
43
44
45
46
47
48
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
17
18
19
20
21
22
23
24
49
50
51
52
53
54
55
56
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
25
26
27
28
29
30
31
32
57
58
59
60
61
62
63
64
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Complementary Devices
IPTS is providing additional devices to complement the basic offering making the selection of IPTS
solution an easy choice:
NetIOX – Addressable Expander board with 8 Relays and 8 Analog inputs (up to 4 expanders are
supported on one network). Supports up to 32 expanders, per one network.
DXETH – Ethernet module that can be plugged on the board for LAN connectivity.
Readers - Supports All IPTS Readers ….and Proximity with Pin/Bio/Wiegand /ABA etc. readers. Supports
up to 100 meters, between the reader/s and the controller.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Technical Specifications
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Physical Characteristics
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
License and Limited Warranty Agreement
The opening of the packaging of the Software and/or the installation of the Software and/or the use of
the Product shall be deemed that you have read and accepted the terms of this License and Limited
Warranty Agreement. If you do not agree to the terms of this agreement, do not use the product.
Promptly return the entire package to the place where you obtained it.
General Terms
You have purchased the right to use the software embedded in some integrated circuits of this Product
and on the enclosed disks and/or CD_ROM or DiskOnKey device (the ‘Software’) and you have
purchased the hardware that is the other part of the Product (the ‘Hardware’), together (the ‘Product’)
produced by IPTS(‘IPTS’).If the Hardware or the Software does not function properly, please return the
Product, together with the copy of your paid receipt, to the place where you obtained it.
License
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
IPTS grants you a license to use the Software subject to terms and conditions of the License agreement
hereto.
You do not own the Software. IPTS and/or third parties remain the sole owner of the Software. The
Software and accompanying documentation are proprietary products of IPTS and/or third parties, and
all title, trade secrets, trade names, trademark patents, copyrights and any other intellectual and
proprietary rights, in the Product whether registered or not, remain the sole property of IPTS and/or
third parties. The property rights of IPTS and/or third parties in the Product are protected by law.
Your rights in the Software are limited to installation of the Software, in the machine-readable form in
accordance with the instructions IPTS provided you, executing the Software after installation, and
making an archive copy(s) in the form provided for backup purposes.The Software may be used only in
conjunction with the Hardware you bought, as an integral part of the Product. Any attempt to
determine the source code for the Software; to modify, reprogram, translate, dissemble, decompose, or
otherwise reverse engineer the Software; selling sublicense, transferring the Software to anyone else; or
allowing any one the access or execute the Software through time sharing services or as a service
bureau are forbidden. Any attempt to do any of these forbidden activities will automatically terminate
your tight to use the Software and our Limited Warranty without any notice from use.
Warranty
The Product, including the media on which the Software is delivered, is warranted to be free of defects
in material and workmanship and shall comply with IPTS specifications, for a period of 24 months of
normal use from the date of purchase (‘the Warranty Period’).The Warranty is void if IPTS’s instructions
of operation, checking and maintenance are ignored, if attempts to repair the Product have been done
before the Product is returned to the place where you obtained it. Responsibility for normal wear and
tear is excluded. The Product is provided ‘As Is’ and without Warranty, by IPTS and/or the distributor
and/or the importer, if the importer is not a distributor (each hereinafter the ‘Distributor’) of the
Product, in the country where the product was purchased, or our suppliers, express or implied, including
without limitation implied warranty of merchantability of fitness any particular purpose. During the
Warranty Period, IPTS’s and/or IPTS’s Distributor sole obligation, in tort, contract, or otherwise, shall be
to repair or replace the defective Product, at IPTS’s option. The repair or replacement of the defective
Product during the Warranty Period will not extend the Warranty Period. The Warranty does not cover
failures resulting from improper operation, connection, or installation.
For your convenience, IPTS’s obligations in connection to Warranty claims, repairs service and
instructions have been transferred to IPTS’s Distributor in your country. The Distributor is responsible
for providing you with all necessary services (If you need the details of the Distributor in your country,
please contact IPTS).However, if according to law, by law EC directive etc. prevailing in the country/state
in which the product was purchased you are entitled a longer warranty period and/or to better
minimum undertaking from IPTS and/or from the distributor than those granted to you herein, then this
document is changed to reflect the said minimum/s.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Disclaimer
IPTS and/or the Distributor make no Warranty, Representation or promise expressed or implied that the
Hardware and/or the Software or associated documentation will satisfy your requirements and/or that
the hardware or software and documentation are without defect or error or that the operation of the
hardware and software will uninterrupted or error free.
Limitation of Liability
Except as otherwise restricted by Law, IPTS’s and/or distributor’s aggregate liability arising from or
relating to your purchase and/or use of the Hardware and/or Software, the associated documentation
or any services provided by IPTS and/or the distributor, is limited to the total of all payments made by or
for you for the Hardware and Software and documentation.
Neither IPTS nor the Distributor or any of their licensors, directors, employees, or any body acting on
their behalf shall in any case be responsible or liable for any special, incidental, consequential, indirect
or punitive damages, even if advised of the possibility of those damages and/or for lost profits or
revenue, loss of contracts, loss of data, costs or re-creating lost data, and/or the cost of any substitute
Hardware and/or Software and/or equipment or programs.
Governing Law and Jurisdiction
Except as otherwise restricted by law, this Agreement shall be governed only by, and interpreted, in
accordance with the laws of the State of Israel and the exclusive jurisdiction shall be vested to the local
courts of Tel Aviv.
Entire Agreement
This Agreement sets forth the entire understanding and rights and duties between you and IPTS. This
Agreement may be amended only in writing signed by both parties. No person or entity is authorized to
modify this Agreement or to make any warranty, representation or promise which is different than, or in
addition to, the representation or promises of this agreement.
Waiver
No waiver of any right under this Agreement shall be effective unless in writing, signed by a duly
authorized representative of the party to be bound. No waiver of any past or present right arising from
any breach or failure to perform shall be deemed to be a waiver of any future right arising under this
Agreement.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929
Severability
If any provision in this Agreement is invalid or unenforceable, that provision shall be construed, limited,
modified or, if necessary, severed, to the extent necessary, to eliminate its invalidity or unenforceability,
and the other provisions of this Agreement shall remain unaffected.
IPTS LTD
Email: [email protected]| www.accessgk.cpm | www.ipts-group.com |Tel: +972 3969 9929