Isover Solution Guide Specifying External Timber Frame Walls July

Isover Solutions Guide
Specifying External Timber Frame Walls
About Saint-Gobain Isover
As a world leader in designing, manufacturing and
distributing building materials, Saint-Gobain is committed
to providing innovative solutions to the most fundamental
challenges facing the world today; reducing energy
consumption, limiting our impact on the environment
and creating a new generation of buildings which are safe,
comfortable and energy efficient.
At Saint-Gobain Isover we develop sustainable insulation
solutions to protect both your built environment and
the natural environment. To maintain our focus we have
placed environmental responsibility at the heart of our
business strategy.
Saint-Gobain: one of the top
100 Industrial groups in the
world and the global leaders
in the construction market.
Our vision to lead the UK mineral wool market in energy
efficiency and acoustic insulation solutions will be
achieved with products that meet the highest thermal,
acoustic and fire safety performance levels. We will
meet changing regulations first and surpass current
regulations for those that wish to excel. Our products
will provide best value solutions for the residential,
commercial, RMI and technical building environments,
be safe to use and help to protect the environment.
Between 15 and 18% of all new homes in the UK are
now timber frame. Popularity of this construction
method has grown over recent years due to speed of
construction and better quality control on-site. For
that reason, ensuring these constructions are energy
efficient is vital if we are to achieve the commitment of
the Climate Change Act to eliminate carbon emissions
from our built environment by 2050.
Between 15 and 18 percent of
all new homes in the UK are
now timber frame.
At Saint-Gobain Isover we are committed to working
jointly with today’s designers and contractors to meet
these challenges, in making buildings of the future as
energy efficient as possible.
2
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Benefits of using Isover insulation
a
rm
l insula
t
ion
The
Solutions providing insulation for three key aspects of the built
environment. The inherent properties of Isover products provide thermal,
acoustic and fire safe insulation for external timber frame walls.
Thermal
Quick and easy on-site
installation
Isover offer energy efficient thermal
solutions to meet and exceed even the most
demanding requirements.
• Push fits between 600mm timber stud
centres with no need for additional fixings
• Isover insulation is manufactured from
high quality glass mineral wool which
makes it lightweight and easy to handle,
cut and install
Acoustic
Isover’s solutions provide a comfortable living
environment, protecting inhabitants from
exterior noise such as road traffic, trains and
aeroplanes.
Environmental leadership
Isover timber frame insulation has excellent
environmental credentials and helps
towards valuable credits for the Code for
Sustainable Homes.
Fire & Safety
Isover insulation is totally non-combustible
and fire safe to protect your most precious
resource and provide a safer building
environment.
• Recycled content of up to 86%
• Zero Ozone Depletion Potential (ODP)
• Global Warming Potential (GWP) of less
than 5
Water resistant
Isover timber frame cavity wall insulation
is resilient to moisture damage in storage,
during transportation and on site during
installation.
Isover timber frame insulation achieves the following BRE Global Green Guide online generic summary ratings
Product name
BRE Global Green
Guide Specification
Element
Reference
Applicable Building Type(s)
Rating
Isover Timber Frame Batt 32
Glass wool insulation
– density 48kg/m³
815320004
Domestic, Health, Industrial,
Commercial, Retail, Education
A+
Isover Timber Frame Batt /
Roll 35
Glass wool insulation
– density 24kg/m³
815320002
Domestic, Health, Industrial,
Commercial, Retail, Education
A+
Isover Timber Frame Batt /
Roll 40
Glass wool insulation
– density 12kg/m³
815320001
Domestic, Health, Industrial,
Commercial, Retail, Education
A+
Isover Timber Frame Batt /
Roll 43
Glass wool insulation
– density 10kg/m³
815320005
Domestic, Health, Industrial,
Commercial, Retail, Education
A+
Isover Frame Façade Slab
Glass wool insulation
– density 80kg/m³
915320059
Domestic, Health, Industrial,
Commercial, Retail, Education
A
Isover Cavity Barriers
Glass wool insulation
– density 12kg/m³
815320001
Domestic, Health, Industrial,
Commercial, Retail, Education
A+
Isover Technical Advice: [email protected] www.isover.co.uk
3
Building regulations & standards
Approved Document L (1A and 2A) 2013
Approved Document L (1A and 2A) 2013 retains the design element of fabric elemental backstops, however it is not
recommended that these are used as the starting point for building design. Achieving the Target for Fabric Energy
Efficiency (TFEE) standard could be significantly dependent on the high performance of one specific feature of fabric
design. If this feature was to perform less well than expected, it would significantly impact on performance. These
are designated as limited design values to discourage inappropriate trade-offs (e.g. poor elemental U-values being
offset by renewables etc.)
As absolute backstop values, the fabric elemental values that remain unchanged from Approved Document L:2010
can be seen in the table below:
External Walls
Limiting fabric parameter (W/m2K)
New Build – Residential
0.30
New Build – Non-Residential
0.35
Section 6 – Scotland 2010
The standards and guidance given in Section 6 2010 are intended to reduce emissions of carbon dioxide by
approximately 30% compared to the 2007 standards. The key changes over the 2007 version are:
• 30% improvement in CO2 emissions for new buildings
• Expanded role for the use of low carbon equipment
• Improved backstops for fabric U-values and service efficiencies for new buildings
Section 6 includes a range of measures which can be used in setting the target emission rate for a notional dwelling.
Included are guideline “notional” U-values, as follows:
External Walls
Limiting fabric parameter (W/m2K)
Notional U-value
(W/m2K)
New Build – Residential
0.25
0.19
New Build – Non-Residential
0.30
0.27
The Code for Sustainable Homes
Passivhaus Trust
Isover products can be specified to achieve reduced
CO2 target emission rates by means of insulation for
improved U-values. Specialist products such as the
Isover Vario Membrane System and expert design
guidance can also help to achieve improved airtightness
performance. For more information or to request a CPD,
call 0115 969 8010.
Isover is a founding member of the Passivhaus Trust.
The Passivhaus Trust is an independent non-profit
organisation that will provide leadership in the UK for the
adoption of the Passivhaus standard and methodology.
Its aim is to promote the principles of Passivhaus as a
highly effective way of reducing energy use and carbon
emissions from buildings in the UK.
For more information visit www.passivhaustrust.org.uk
UK Timber Frame Association
Isover is a member of the UKTFA, working with the
association and its members to highlight the benefits
of timber frame construction and promote best practice
within the industry.
4
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solutions overview
Constructions are designed to meet or exceed 2010 Approved Document L Building Regulations up to Passivhaus
standard. The table below provides a snapshot of the U-values that can be achieved with each solution.
1
90mm stud
with insulation
between
2
140mm stud
with insulation
between
3
90mm stud
with insulation
between and
service void
4
140mm stud
with insulation
between and
service void
5
90mm stud
with insulation
between and
thermal laminate
6
140mm stud
with insulation
between and
thermal laminate
7
90mm stud
with insulation
between and FFS
outside
8
140mm stud
with insulation
between and FFS
outside
9
184mm stud
with insulation
between
10
Twin frame
with insulation
between
Isover Technical Advice: [email protected] 0.10
0.11
0.12
0.13
0.15
0.14
Low carbon Passivhaus
0.17
0.16
0.18
0.20
0.19
0.22
0.21
CfSH
- Level 4
0.23
0.24
0.25
0.26
0.27
0.28
Approved
Document
L1A 2010
0.30
0.29
0.32
0.31
0.33
External Wall Solutions (W/m2K)
Approved
Document
L2A 2010
0.35
0.34
Construction to meet =
www.isover.co.uk
5
Solution overview
1 Timber frame wall – 90mm stud
with insulation between
1
2
3
4
5
6
7
3
103mm brick
50mm clear cavity
Breather membrane or reflective breather membrane
9mm OSB sheathing board
90mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
4
7
5
6
1
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (90mm)
Wall thickness (mm)
British Gypsum plasterboard
With standard breather membrane
0.44
Isover Timber Frame Batt 43
265
12.5mm Gyproc WallBoard
0.42
Isover Timber Frame Batt / Roll 40
265
12.5mm Gyproc WallBoard
0.40
Isover Timber Frame Batt / Roll 35
265
12.5mm Gyproc WallBoard
0.38
Isover Timber Frame Batt 32
265
12.5mm Gyproc WallBoard
With reflective breather membrane
0.35
Isover Timber Frame Batt 43
265
12.5mm Gyproc WallBoard
0.34
Isover Timber Frame Batt / Roll 40
265
12.5mm Gyproc WallBoard
0.32
Isover Timber Frame Batt / Roll 35
265
12.5mm Gyproc WallBoard
0.30
Isover Timber Frame Batt 32
265
12.5mm Gyproc WallBoard
Isover
insulation
Isover Timber Frame Batt Isover Timber Frame Roll
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
6
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solution overview
2 Timber frame Wall –140mm stud
with insulation between
1
2
3
4
5
6
7
3
103mm brick
50mm clear cavity
Breather membrane or reflective breather membrane
9mm OSB sheathing board
140mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
4
7
5
6
1
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (140mm)
Wall thickness (mm)
British Gypsum plasterboard
With standard breather membrane
0.31
Isover Timber Frame Batt 43
315
12.5mm Gyproc WallBoard
0.30
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.28
Isover Timber Frame Batt / Roll 35
315
12.5mm Gyproc WallBoard
0.26
Isover Timber Frame Batt 32
315
12.5mm Gyproc WallBoard
With reflective breather membrane
0.26
Isover Timber Frame Batt 43
315
12.5mm Gyproc WallBoard
0.25
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.24
Isover Timber Frame Batt / Roll 35
315
12.5mm Gyproc WallBoard
0.23
Isover Timber Frame Batt 32
315
12.5mm Gyproc WallBoard
Isover
insulation
Isover Timber Frame Batt Isover Timber Frame Roll
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
Isover Technical Advice: [email protected] www.isover.co.uk
7
Solution overview
Green
Guide
A+
For the full BRE Green
Guide online generic
construction rating
specification, please
visit: www.bre.co.uk/
greenguide
3 Timber frame wall – 90mm stud with
insulation between and service void
1
2
3
4
5
6
7
8
3
6
103mm brick
50mm Clear Cavity
Breather membrane
9mm OSB sheathing board
90mm timber stud and Isover insulation between (see table below)
50mm service void with or without Isover Acoustic Partition Roll (APR 1200)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
4
8
7
5
1
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (90mm)
Wall thickness (mm)
British Gypsum plasterboard
With clear service void
0.40
Isover Timber Frame Batt 43
315
12.5mm Gyproc WallBoard
0.38
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.36
Isover Timber Frame Batt / Roll 35
315
12.5mm Gyproc WallBoard
0.34
Isover Timber Frame Batt 32
315
12.5mm Gyproc WallBoard
With Isover Acoustic Partition Roll (APR1200) in service void
0.31
Isover Timber Frame Batt 43
315
12.5mm Gyproc WallBoard
0.30
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.29
Isover Timber Frame Batt / Roll 35
315
12.5mm Gyproc WallBoard
0.28
Isover Timber Frame Batt 32
315
12.5mm Gyproc WallBoard
Isover insulation
Isover Acoustic
Partition Roll
Isover Timber Frame Batt
Isover Timber Frame Roll Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
8
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solution overview
4 Timber frame wall – 140mm stud with
insulation between and service void
1
2
3
4
5
6
7
8
3
6
103mm brick
50mm Clear Cavity
Breather membrane
9mm OSB sheathing board
140mm timber stud and Isover insulation between (see table below)
50mm service void with or without Isover Acoustic Partition Roll (APR 1200)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
A+
4
Green
Guide
8
7
5
1
2
For the full BRE Green
Guide online generic
construction rating
specification, please
visit: www.bre.co.uk/
greenguide
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (140mm)
Wall thickness (mm)
British Gypsum plasterboard
With clear service void
0.29
Isover Timber Frame Batt 43
365
12.5mm Gyproc WallBoard
0.28
Isover Timber Frame Batt / Roll 40
365
12.5mm Gyproc WallBoard
0.26
Isover Timber Frame Batt / Roll 35
365
12.5mm Gyproc WallBoard
0.25
Isover Timber Frame Batt 32
365
12.5mm Gyproc WallBoard
With Isover Acoustic Partition Roll in service void
0.24
Isover Timber Frame Batt 43
365
12.5mm Gyproc WallBoard
0.24
Isover Timber Frame Batt / Roll 40
365
12.5mm Gyproc WallBoard
0.22
Isover Timber Frame Batt / Roll 35
365
12.5mm Gyproc WallBoard
0.21
Isover Timber Frame Batt 32
365
12.5mm Gyproc WallBoard
Isover insulation
Isover Acoustic
Partition Roll
Isover Timber Frame Batt
Isover Timber Frame Roll Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
Isover Technical Advice: [email protected] www.isover.co.uk
9
Solution overview
5 Timber frame wall – 90mm stud with
insulation between and thermal laminate
1
2
3
4
5
6
7
103mm brick
50mm clear cavity
Breather membrane
9mm OSB sheathing board
90mm timber stud and Isover insulation between (see table below)
12.5mm Gyproc WallBoard
Gyproc ThermaLine laminate (see table below)
3
4
5
7
1
6
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (90mm)
Gyproc ThermaLine plus
0.30
Isover Timber Frame Batt 43
0.30
Isover Timber Frame Batt / Roll 40
0.28
Isover Timber Frame Batt / Roll 35
0.27
Isover Timber Frame Batt 32
0.29
Isover Timber Frame Batt 43
0.28
Isover Timber Frame Batt / Roll 40
0.27
Isover Timber Frame Batt / Roll 35
0.26
Isover Timber Frame Batt 32
Gyproc ThermaLine super
0.24
Isover Timber Frame Batt 43
0.23
Isover Timber Frame Batt / Roll 40
0.22
Isover Timber Frame Batt / Roll 35
0.22
Isover Timber Frame Batt 32
0.19
Isover Timber Frame Batt 43
0.19
Isover Timber Frame Batt / Roll 40
0.18
Isover Timber Frame Batt / Roll 35
0.17
Isover Timber Frame Batt 32
Isover
insulation
Wall thickness (mm)
British Gypsum plasterboard
305
305
305
305
300
300
300
300
40mm Gyproc ThermaLine plus
315
315
315
315
335
335
335
335
50mm Gyproc ThermaLine super
Isover Timber Frame Batt Isover Timber Frame Roll
48mm Gyproc ThermaLine plus
70mm Gyproc ThermaLine super
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
10
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solution overview
6 Timber frame wall – 140mm stud with
insulation between and thermal laminate
1
2
3
4
5
6
7
103mm brick
50mm clear cavity
Breather membrane
9mm OSB sheathing board
140mm timber stud and Isover insulation between (see table below)
12.5mm Gyproc WallBoard
Gyproc ThermaLine laminate (see table below)
3
4
5
7
1
6
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (140mm)
Gyproc ThermaLine plus
0.27
Isover Timber Frame Batt 43
0.26
Isover Timber Frame Batt / Roll 40
0.24
Isover Timber Frame Batt / Roll 35
0.23
Isover Timber Frame Batt 32
0.23
Isover Timber Frame Batt 43
0.22
Isover Timber Frame Batt / Roll 40
0.21
Isover Timber Frame Batt / Roll 35
0.20
Isover Timber Frame Batt 32
Gyproc ThermaLine super
0.19
Isover Timber Frame Batt 43
0.19
Isover Timber Frame Batt / Roll 40
0.18
Isover Timber Frame Batt / Roll 35
0.17
Isover Timber Frame Batt 32
0.16
Isover Timber Frame Batt 43
0.16
Isover Timber Frame Batt / Roll 40
0.15
Isover Timber Frame Batt / Roll 35
0.14
Isover Timber Frame Batt 32
Isover
insulation
Wall thickness (mm)
British Gypsum plasterboard
342
342
342
342
350
350
350
350
27mm Gyproc ThermaLine plus
365
365
365
365
385
385
385
385
50mm Gyproc ThermaLine super
Isover Timber Frame Batt Isover Timber Frame Roll
48mm Gyproc ThermaLine plus
70mm Gyproc ThermaLine super
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
Isover Technical Advice: [email protected] www.isover.co.uk
11
Solution overview
7 Timber frame wall – 90mm stud with insulation
between and Isover Frame Façade Slab outside
1
3
2
4
5
6
103mm brick
Cavity partially filled with 50mm Isover Frame Façade Slab
(integral breather membrane)
9mm OSB sheathing board
90mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
3
4
1
6
5
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (90mm)
Wall thickness (mm)
British Gypsum plasterboard
0.25
Isover Timber Frame Batt 43
315
12.5mm Gyproc WallBoard
0.25
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.24
Isover Timber Frame Batt / Roll 40
315
12.5mm Gyproc WallBoard
0.23
Isover Timber Frame Batt 32
315
12.5mm Gyproc WallBoard
Isover insulation
Isover
Timber Frame Batt
Isover
Timber Frame Roll
Isover
Vario Membrane System
Isover
Cavity Barriers
Isover
Frame Façade Slab
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
12
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solution overview
8 Timber frame wall – 140mm stud with insulation
between and Isover Frame Façade Slab outside
1
3
2
4
5
6
103mm brick
avity partially filled with 50mm Isover Frame Façade Slab
C
(integral breather membrane)
9mm OSB sheathing board
140mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
3
4
1
6
5
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (140mm)
Wall thickness (mm)
British Gypsum plasterboard
0.21
Isover Timber Frame Batt 43
365
12.5mm Gyproc WallBoard
0.20
Isover Timber Frame Batt / Roll 40
365
12.5mm Gyproc WallBoard
0.19
Isover Timber Frame Batt / Roll 40
365
12.5mm Gyproc WallBoard
0.18
Isover Timber Frame Batt 32
365
12.5mm Gyproc WallBoard
Isover insulation
Isover
Timber Frame Batt
Isover
Timber Frame Roll
Isover
Vario Membrane System
Isover
Cavity Barriers
Isover
Frame Façade Slab
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
Isover Technical Advice: [email protected] www.isover.co.uk
13
Solution overview
9 Timber frame Wall – 184mm stud with
insulation between
1
2
3
4
5
6
7
3
103mm brick
50mm clear cavity
Breather membrane or reflective breather membrane
9mm OSB sheathing board
184mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
12.5mm Gyproc WallBoard
4
5
7
1
6
2
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (2 x 90mm)
Wall thickness (mm)
British Gypsum plasterboard
With standard breather membrane
0.26
Isover Timber Frame Batt 43
360
12.5mm Gyproc WallBoard
0.25
Isover Timber Frame Batt / Roll 40
360
12.5mm Gyproc WallBoard
0.23
Isover Timber Frame Batt / Roll 35
360
12.5mm Gyproc WallBoard
0.22
Isover Timber Frame Batt 32
360
12.5mm Gyproc WallBoard
With reflective breather membrane
0.22
Isover Timber Frame Batt 43
360
12.5mm Gyproc WallBoard
0.21
Isover Timber Frame Batt / Roll 40
360
12.5mm Gyproc WallBoard
0.20
Isover Timber Frame Batt / Roll 35
360
12.5mm Gyproc WallBoard
0.19
Isover Timber Frame Batt 32
360
12.5mm Gyproc WallBoard
Isover
insulation
Isover Timber Frame Batt Isover Timber Frame Roll
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
14
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Solution overview
10 Timber frame Wall – Twin frame
1
2
3
4
5
6
7
8
9
10
3
103mm brick
50mm clear cavity
Breather membrane or reflective breather membrane
9mm OSB sheathing board
90mm timber stud and Isover insulation between (see table below)
90mm cavity between frames and Isover insulation (see table below)
90mm timber stud and Isover insulation between (see table below)
Vapour control and airtightness membrane (Isover Vario Membrane System)
Timber counter battens
12.5mm Gyproc WallBoard
5
6
A+
4
7
1
8
10
9
2
Green
Guide
For the full BRE Green
Guide online generic
construction rating
specification, please
visit: www.bre.co.uk/
greenguide
(Isover Cavity Barriers should be installed within the wall cavity as required by Building Regulations)
U-value W/m²K
Isover insulation (3 x 90mm)
Wall thickness (mm)
British Gypsum plasterboard
With standard breather membrane
0.16
Isover Timber Frame Batt 43
445
12.5mm Gyproc WallBoard
0.15
Isover Timber Frame Batt / Roll 40
445
12.5mm Gyproc WallBoard
0.14
Isover Timber Frame Batt / Roll 35
445
12.5mm Gyproc WallBoard
0.13
Isover Timber Frame Batt 32
445
12.5mm Gyproc WallBoard
With reflective breather membrane
0.15
Isover Timber Frame Batt 43
445
12.5mm Gyproc WallBoard
0.14
Isover Timber Frame Batt / Roll 40
445
12.5mm Gyproc WallBoard
0.13
Isover Timber Frame Batt / Roll 35
445
12.5mm Gyproc WallBoard
0.12
Isover Timber Frame Batt 32
445
12.5mm Gyproc WallBoard
Isover
insulation
Isover Timber Frame Batt Isover Timber Frame Roll
Isover Vario Membrane System
Isover Cavity Barriers
British Gypsum plasterboards
Gyproc WallBoard
Gyproc ThermaLine basic
Gyproc ThermaLine plus
Gyproc ThermaLine super
NB: Alternative plasterboards from other manufacturers may be used. It is the responsibility of the specifier to ensure equivalent performance.
Isover Technical Advice: [email protected] www.isover.co.uk
15
Product overview
Isover Timber Frame Batt
A glass mineral wool batt providing thermal and
acoustic insulation for timber walls and roofs to help
meet Approved Document L (England and Wales) and
Section 6 (Scotland).
3Excellent thermal performance with a thermal
conductivity of 0.032 to 0.043W/mK within the
range. Helps to meet the requirements of Approved
Document L 2010 (England & Wales) and Section 6
(Scotland)
3Push fits between 600mm timber stud centres with
no need for additional fixings
3Two batts end-to-end typically fit standard storey
height
Easy to install
Isover Timber Frame Batts are manufactured
from high quality glass mineral wool which
makes it lightweight and easy to handle, cut
and install.
Protected planet
Excellent environmental credentials and
helps towards valuable credits for the Code
for Sustainable Homes.
• Isover Timber Frame Batt corresponds to
the BRE Global Green Guide online generic
specification ‘Glass wool insulation’ –
density 48kg/m³ ref 815320004 which
achieves a summary rating of A+ within
Domestic, Health, Industrial, Commercial,
Retail, Education.
• Recycled content of up to 86%.
• Zero Ozone Depletion Potential (ODP).
• Global Warming Potential (GWP) of less
than 5.
Water resistant
Resilient to moisture damage in storage,
during transportation and on-site during
installation.
Euroclass A1 fire rating
Totally non-combustible and fire safe.
16
Product
Thickness
(mm)
Thermal
conductivity
(W/mK)
Thermal
resistance
(m²K/W)
Width
(mm)
Length
(mm)
Batts per
pack
Pack area
(m²)
Isover Timber Frame Batt 32
90
0.032
2.81
570
1175
5
3.35
Isover Timber Frame Batt 32
140
0.032
4.38
570
1175
5
3.35
Isover Timber Frame Batt 35
90
0.035
2.57
570
1175
10
6.70
Isover Timber Frame Batt 35
140
0.035
4.00
570
1175
6
4.02
Isover Timber Frame Batt 40
90
0.040
2.25
570
1175
14
9.38
Isover Timber Frame Batt 40
140
0.040
3.50
570
1175
8
5.36
Isover Timber Frame Batt 43
90
0.043
2.09
570
1175
12
8.04
Isover Timber Frame Batt 43
140
0.043
3.26
570
1175
8
5.36
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Product overview
Isover Timber Frame Roll
A glass mineral wool roll providing thermal and acoustic
insulation for timber walls to help meet Approved
Document L (England and Wales) and Section 6
(Scotland).
3Excellent thermal performance with a thermal
conductivity of 0.035 to 0.040W/mK within the
range. Helps to meet the requirements of Approved
Document L 2010 (England & Wales) and Section 6
(Scotland)
3Push fits between 600mm timber stud centres with
no need for additional fixings
Easy to install
Isover Timber Frame Rolls are manufactured
from high quality glass mineral wool which
makes it lightweight and easy to handle, cut
and install.
Protected planet
Excellent environmental credentials and
helps towards valuable credits for the Code
for Sustainable Homes.
• Isover Timber Frame Roll corresponds to
the BRE Global Green Guide online generic
specification ‘Glass wool insulation’ –
density 24kg/m³ ref 815320002 which
achieves a summary rating of A+ within
Domestic, Health, Industrial, Commercial,
Retail, Education.
• Recycled content of up to 86%.
• Zero Ozone Depletion Potential (ODP).
• Global Warming Potential (GWP) of less
than 5.
Water resistant
Resilient to moisture damage in storage,
during transportation and on-site during
installation.
Euroclass A1 fire rating
Totally non-combustible and fire safe.
Product
Thickness
(mm)
Thermal
conductivity
(W/mK)
Thermal
resistance
(m²K/W)
Width
(mm)
Length
(mm)
Pack area
(m²)
Isover Timber Frame Roll 35
90
0.035
2.57
570
1175
6.04
Isover Timber Frame Roll 35
140
0.035
4.00
570
1175
4.56
Isover Timber Frame Roll 40
90
0.040
2.25
570
1175
11.35
Isover Timber Frame Roll 40
140
0.040
3.50
570
1175
7.41
Isover Technical Advice: [email protected] www.isover.co.uk
17
Product overview
Isover Frame Façade Slab
A low lambda rigid glass mineral wool slab providing
a continuous layer of insulation around timber frame
constructions.
a
rm
l insula
t
ion
The
3Continuous layer of insulation reduces cold bridging
through the frame enabling U-values down to low
carbon levels
3Weatherproof breathable facing protects the
construction and negates the need for an additional
breather membrane
3Tongue and groove vertical joints to minimise
thermal bridging
3Full range of accessories available including
wall-ties, spacers and sealing tape
Thermal Insulation
Excellent thermal performance with a
thermal conductivity of 0.031W/mK. Provides
a continuous layer of insulation around the
frame, reducing cold bridging and allowing
very low U-values to be achieved.
Protected planet
Excellent environmental credentials and
helps towards valuable credits for the Code
for Sustainable Homes.
• Isover Frame Façade Slab corresponds to
the BRE Global Green Guide online generic
specification ‘Glass wool insulation’ –
density 80kg/m³ ref 915320059 which
achieves a summary rating of A within
Domestic, Health, Industrial, Commercial,
Retail, Education.
• Recycled content of up to 86%.
• Zero Ozone Depletion Potential (ODP).
• Global Warming Potential (GWP) of less
than 5.
Easy to install
Supplied in 1200 x 1800mm slabs to provide
quick coverage of large areas.
Water resistant
Resilient to moisture damage in storage, during
transportation and on-site during installation.
Euroclass A1 fire rating
Totally non-combustible and fire safe.
18
Product
Thickness
(mm)
Thermal
conductivity
(W/mK)
Thermal
resistance
(m²K/W)
Width
(mm)
Length
(mm)
Batts per
pack
Pack area
(m²)
Isover Frame Façade Slab
50
0.031
1.61
1200
1800
4
8.64
Product
Units
Measure
Thermal Break Wall Tie
1 box
250 ties
Spacer
1 box
250 spacers
Sealing Tape
1 box (12 rolls)
50m per roll
www.isover.co.uk Isover Technical Advice – Tel: 0115 945 1143
Achieving high levels of energy efficiency
in timber frame constructions
Product overview
Isover Vario Membrane System Isover Cavity Barriers
A high performance membrane unique in providing
excellent levels of airtightness with unparalleled
protection against moisture.
A non-combustible glass wool cavity barrier used to
restrict the spread of smoke and flames and to minimise
flanking noise transmission in concealed cavities.
3Improves the energy efficiency of the building by
reducing heat loss
3Improves thermal comfort by protecting against
leaky cracks and joints which invariably cause
uncomfortable drafts
3Ideal for use in low energy and Passivhaus
constructions and buildings with mechanical
ventilation and heat recovery systems
3Intelligent moisture management properties help
to protect the building fabric from moisture damage
3Provides up to 100 minutes fire protection
in concealed cavities which helps to meet
requirements of Approved Document B (England &
Wales) and Section 2 (Scotland)
3Helps minimise flanking sound transmission along
the wall cavity
3Helps towards a zero U-value separating
wall by providing effective edge sealing¹
Product
Units
Measure
Isover Vario
KM Duplex
Membrane
1 roll (60m²)
40m x 1.5m
Isover Vario
Multitape
1 box (10 rolls)
25m
Isover Vario KB1
1 box (5 rolls)
40m
Isover Vario DS
Sealant
1 box
(12 cartridges)
310ml
cartridges
¹ A cavity barrier on its own may not be effective in
restricting air flow
3Isover Cavity Barriers correspond to the BRE
Global Green Guide online generic specification
‘Glass wool insulation’ – density 10kg/m³
(ref. 815320005) which achieves a summary rating
of ‘A+’ within all building types.
Product
Isover Cavity
Barrier (65)
Isover Cavity
Barrier (80)
Isover Cavity
Barrier (100)
Isover Cavity
Barrier (65)
Isover Cavity
Barrier (80)
Isover Cavity
Barrier (100)
Isover Cavity
Barrier (65)
Isover Cavity
Barrier (80)
Isover Cavity
Barrier (100)
Isover Technical Advice: [email protected] Cavity
Length Width
Size (mm) (mm)
(mm)
50-65
1200
100
Sleeve
colour
Yellow
66-80
1200
100
Blue
81-100
1200
100
White
50-65
1200
300
Yellow
66-80
1200
300
Blue
81-100
1200
300
White
50-65
2400
300
Yellow
66-80
2400
300
Blue
81-100
2400
300
White
www.isover.co.uk
19
www.3pointplan.co.uk
Isover Order Placement or Order Enquiries:
Tel: 0800 032 2555
Fax: 0800 917 9188
www.isover.co.uk
Published Date: July 2014
Isover Document Reference: I-ETFW-SG-1401
Buildings Insulation – Technical Enquiries
Tel: 0115 945 1143
Email: [email protected]
Saint-Gobain Isover
Gotham Road
East Leake
Loughborough
Leicestershire
LE12 6HX
Tel: 0115 969 8010
Email: [email protected]
Isover reserves the right to revise product specifications without notice. The information in this
document was correct to the best of our knowledge at the time of publication. It is the users
responsibility to ensure that it remains current prior to use. The information in this document
is for guidance only and should not be read in isolation. Users should read and familiarise
themselves with all the information contained in this document and ensure that they are fully
conversant with the products and systems being used, before subsequent specification or
installation. For a comprehensive and up to date library of information visit the Isover website.