BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL BGE - SUPPLIER PARTICIPATION IN GAS CHOICE PROGRAMS BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL I. Introduction ............................................................................................................................................... 4 II. Account Request Process ........................................................................................................................ 4 A. B. Timeline ............................................................................................................................................ 4 A. 1 12 Calendar Days Prior to First of the Month .......................................................................... 4 A. 2 17th Workday ........................................................................................................................... 4 Instructions for uploading the ACCOUNT_RQST_TO_LDC.xml file on the ACCOUNT REQUEST Screen .............................................................................................................................................. 5 C. ACCOUNT_RQST_TO_LDC and ACCOUNT_RESP Data Definitions ........................................... 6 D. Account Request Transaction Responses and Reports .................................................................. 6 E. Error Code Definitions ...................................................................................................................... 6 III. Daily Requirement ................................................................................................................................... 6 A. Calculation ....................................................................................................................................... 7 A. 1 Winter Season (Nov – Mar) ..................................................................................................... 7 A. 2 Summer Season (Apr – Oct) ................................................................................................... 8 B. Penalties .......................................................................................................................................... 8 C. Annual True-Up ................................................................................................................................ 9 IV. Parking and Balancing Service ............................................................................................................. 10 A. Parking Service .............................................................................................................................. 10 B. Balancing Service .......................................................................................................................... 10 C. Pool Capacity Allocation ................................................................................................................ 10 D. Inventory Allocation ........................................................................................................................ 11 E. Injections and Withdrawals ............................................................................................................ 11 E.1 Winter Season ....................................................................................................................... 11 a. b. c. Inventory Withdrawal Ratchets and Injection Rights ........................................................... 11 Inventory Envelopes ............................................................................................................ 12 Maximum Withdrawal and Injection Volumes (by month, by day) ...................................... 12 E. 2 Summer Season .................................................................................................................... 12 a. b. Inventory Injection and Withdrawal Rights .......................................................................... 12 Inventory Envelopes ............................................................................................................ 13 Page 2 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL c. Maximum Withdrawal and Injection Volumes (by month, by day) ...................................... 14 F. Penalties ........................................................................................................................................ 14 G. POOL Screen ................................................................................................................................. 15 G. 1 Instructions for Entering Pool Injections and Withdrawals .................................................... 15 G. 2 Fields on the POOL Screen .................................................................................................. 16 G. 3 Pool Activity Report ............................................................................................................... 20 Page 3 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL I. Introduction This Manual fully describes procedures for participating in the Baltimore Gas and Electric Company (BGE) Daily Requirements Service (DRS) program. The DRS program allows suppliers to serve residential and small commercial customers that choose to participate in the Gas Choice program. The procedures and processes outlined in this Manual are based upon the North American Energy Standards Board (NAESB) ratified Model Business Practices and adhere to COMAR 20.59 [RM35] regulations to govern competitive gas supply. The procedures detail the Account Request Process, Daily Requirement and Parking and Balancing Service. II. Account Request Process The Enrollment process for DRS customers is handled via the ACCOUNT REQUEST screen in DSWeb. The ACCOUNT REQUEST screen allows suppliers to “E” – Enroll, “D” – Drop, “C” – Change and “X” - Cancel Commercial and Residential DRS customers from the Gas Choice program. Suppliers must upload their Account Request Transactions using the ACCOUNT_RQST_TO_LDC.xml file. All Account Request Transactions must be submitted 12 calendar days prior to the start of the month to be effective the 1st of each respective month. When customers enroll in the DRS program or switch from one supplier to another supplier, BGE sends a confirmation enrollment letter to the customer. When a customer drops from the Delivery Service program and returns to the utility, BGE sends a confirmation termination letter to the customer. Please note that you as the supplier are still required to provide notice to your customers when your relationship with them is ending. A. Timeline The following is a description of the Account Request timeline. A. 1 12 Calendar Days Prior to First of the Month Suppliers can use the ACCOUNT REQUEST screen to submit “E” – Enroll, “D” – Drop, “C” – Change and “X” - Cancel transactions daily using the ACCOUNT_RQST_TO_LDC.xml file, until 5:00 PM EST. BGE will process the Enrollment Transactions daily and return an ACCOUNT_RESP.xml file by start of business the next morning detailing the Accept or Reject status of each transaction. The following are definitions of the Account Request Transactions. “Enrollment” means the addition of a customer to a supplier’s service. “Drop” means the removal of a customer from a supplier’s service. “Change” means the change of a Supplier Group Number “Cancel” means the reversal of a previous transaction Please refer to the DRS Enrollment Windows.doc document in the Key Dates and Lists Category of the Main Library in DSWeb for specific dates associated with the enrollment windows for the 1st of each month. A. 2 17th Workday Page 4 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL The supplier’s final Account Request confirmation will be communicated via the ADCQ Detail Report (ADCQDTLmmddyy.prn). The ADCQ Detail Report is available on the 17th workday of the month prior to the month gas is scheduled to flow. The report will display the actual Daily Contract Quantity (DCQ) in dekatherms (up to three decimal places) for all active customers for the next month. All new customers for the first of the month will be identified with an asterisk (*). An estimate of all new customer’s monthly DCQ for a projected 12-month period will be provided through the Monthly Annual DCQ Report (DCQSmmdd.rpt). A summary of DCQ’s for the next month by Residential and Commercial Supplier Groups will be provided through the ADCQ Summary Report (ADCQSUMmmddyy.rpt). B. Instructions for uploading the ACCOUNT_RQST_TO_LDC.xml file on the ACCOUNT REQUEST Screen The following are the steps to be followed to successfully upload an ACCOUNT_RQST_TO_LDC.xml file to the DSWeb using the ACCOUNT REQUEST tab. Click on the ACCOUNT REQUEST Tab in DSWeb. Click the Open button at the bottom of the page. Click the Browse button on the Open Enrollments from File Dialog Box Locate your ACCOUNT_RQST_TO_LDC.xml file in the Choose File to Upload Dialog Box and click the Open button Click the Upload button in the Open Enrollments from File Dialog Box Page 5 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL C. ACCOUNT_RQST_TO_LDC and ACCOUNT_RESP Data Definitions The Data Definitions for the ACCOUNT_RQST_TO_LDC and ACCOUNT_RESP transactions can be found in the XML Data Definitions document found in the Fixed File Layouts Category of the Main Library in DSWeb. D. Account Request Transaction Responses and ADCQ Reports The following listing details the Account Request Transaction Responses and the ADCQ reports. The Account Request Transactions Responses are generated each day, while the ADCQ reports are generated on the 17th workday. ADCQ represents the Average Daily Contract Quantity. The ADCQ is calculated as an average of the last two year’s usage for the respective month. For example, the ADCQ for June 2012 would be the average of the usage that was metered in June 2010 and June 2011. ACCOUNT_RESP Each day BGE will return an ACCOUNT_RESP.xml and ACCOUNT_RESP.rpt file for any Account Request Transactions that were uploaded the previous day. These files will detail whether each Account Request Transaction was Accepted or Rejected. ADCQ Detail Report ADCQ Detail Report – This report will display the actual DCQ in dekatherms (up to three decimal places) for all active customers for the next month. All new customers will be identified with an asterisk (*). This report is only available in a .prn format. report name = ADCQDTLmmddyy.prn (mm = month, dd = day, yy = year) ADCQ Summary Report This report will provide suppliers with a summary DCQ in dekatherms by Supplier Group. The report also shows the total number of new customers and the grand total number of accounts for the next month. This report is available in both .prn and .rpt formats. report name = ADCQSUMmmdd.rpt and ADCQSUMmmdd.prn (mm = month, dd = day) E. Error Code Definitions There are a number of reasons that an Enrollment Transaction may be rejected. If an Enrollment Transaction is rejected, BGE will return an Error Code and Description. Please refer to the XML Error Definitions document found in the Fixed File Layouts Category of the DSWeb Main Library for a complete list of Error Codes and Descriptions associated with the ACCOUNT_RQST_TO_LDC transaction. III. Daily Requirement Page 6 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL At 12:00 PM each day, BGE will calculate the daily requirement and maximum pool injection and withdrawal volumes for the next five days. The first of these five days is the gas day that begins at 10:00 AM. The daily requirement for the gas day beginning at 10:00 AM will not change unless there is a significant difference in the forecasted temperature between 12:00 PM and 7:00 AM forecasted temperatures. It is important to note that the daily requirement for the next four days will most likely change as BGE receives estimated temperature updates. At 9:00 AM, BGE will finalize the daily requirement for the gas day beginning at 10:00 AM. DRS suppliers will have three options available to fulfill their daily requirement. These three options are listed below. Flowing pipeline BGE allocated pool withdrawal BGE allocated pool injection Each DRS supplier has until 2:00 PM to finalize their BGE allocated pool nominations for the current gas day. At 2:00 PM all storage adjustments will be finalized and the next day’s beginning inventory will be calculated. All pipeline nominations are subject to the current Gas Industry Standards Board (GISB) standards. After the daily requirement is calculated at 12:00 PM and after the storage day has ended at 2:00 PM, the suppliers should refresh their browsers to obtain updated information. The DRS supplier will be considered to be in balance when they nominate and deliver to BGE the total daily requirement and nominated injections. If the supplier does not deliver the total daily requirement and nominated injections, or the supplier with only DRS customers overdelivers to BGE, they will incur penalties. A. Calculation The following describes the calculation of the Daily Requirement. The calculation of the Daily Requirement differs based whether the gas day is in a Winter (Oct – May) or Summer (Jun – Sep) season. A. 1 Winter Season (Oct – May) The daily requirement for an individual supplier during the Winter season is based upon a set of linear regression equations which are generated daily based on the most recent seven day’s temperature and sample meter consumption per customer data. A linear regression equation is generated for each of the following customer classes. D – Residential DH – Residential with Heat C – Commercial CH – Commercial with Heat CLX – Commercial > 1,500 Two “stabilizer points”, are added to each linear regression equation to eliminate large swings in the line that is generated. The independent variable “X” is the average daily temperature and the dependent variable “Y” is average daily consumption per customer based on sample meter readings. Page 7 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL The forecasted daily load is generated using the following equation for the Winter season (Oct – May): Daily Load = [(slope * forecast temp) + intercept] * # of customers * (1/(1-unaccounted for factor)) * (suppliers average class ADCQmonth / system average class ADCQmonth) The Daily Requirement is the smaller of: the Daily Load for the respective customer class as calculated above or, the Daily Max for the respective customer class as calculated below. Daily Max = [max delivered gas per customer] * # of customers * (suppliers average class ADCQJan / system average class DCQJan) Daily Requirement = MIN(Daily Load, Daily Max) At the beginning of the heating season BGE determines a maximum delivered gas per customer by customer class. If the Daily Load as calculated by the algorithm exceeds the Daily Max, then the suppliers is required to deliver only the Daily Max value. The remainder will be made up by BGE peak shaving assets, and billed to the supplier as peak shaving supply. The peak shaving volume is the difference between the supplier’s daily requirement and daily load. A. 2 Summer Season (Jun – Sep) The daily requirement for an individual supplier during the Summer season is based on the system average class ADCQ for the month, plus the Daily Requirement Adjustment to reconcile for the annual true-up. See Annual True-Up section for a detailed explanation of the Daily Requirement Adjustment. The forecasted Daily Requirement is generated using the following equation for the Summer season (Jun - Sep): Daily Requirement = system average class ADCQ month * # of customers * (1/(1-unaccounted for factor)) * (suppliers average class ADCQmonth / system average class ADCQ month) + Daily Requirement Adjustment B. Penalties Suppliers are subject to performance-related penalties. A supplier is subject to penalty if the over-deliver the Daily Requirement, under-deliver the Daily Requirement or under-deliver their nominated injection volume. Each of these penalties are detailed below. Over-delivery of the Daily Requirement Suppliers must deliver the Daily Requirement. A penalty of $5.00 per Dth will be imposed on every Dth of over-delivered volume. The over-delivered volume subject to penalty will be Page 8 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL equal to the negative of the Daily Requirement minus the sum of actual pipeline deliveries and pool withdrawal nominations. Failure to Deliver Daily Requirement Suppliers must deliver the Daily Requirement. A $25.00 per Dth penalty will be imposed on every Dth of under-delivery. In addition, the under-delivered volume must be purchased from BGE by the supplier. The transaction price shall be 110% of the highest Transco Zone 6 (non-New York) price for the month. The under-delivered volume subject to penalty will be equal to the Daily Requirement minus the sum of actual pipeline deliveries and pool withdrawal nominations. Failure to Deliver Injection Suppliers must deliver all nominated injection volumes. A $25.00 per Dth penalty will be imposed on every Dth of under-delivery. In addition, the under-delivered volume must be purchased from BGE by the supplier. The transaction price shall be 110% of the highest Transco Zone 6 (non-New York) price for the month. The under-delivered volume subject to penalty will be equal to the nominated injection volume minus the sum of actual pipeline deliveries and pool withdrawal nominations. C. Annual True-Up On the 3rd work day of each month, BGE reconciles DRS supplier’s daily requirement deliveries and actual customer usage for each customer class through a process called the trueup. The supplier’s daily requirement deliveries are determined by summing the daily requirement and peakshaving volumes by class, for the respective month. The supplier’s actual customer usage is determined by class, after it is converted from a billing month basis to a calendar month basis. The customer class true-up is the sum of the supplier’s actual customer usage (adjusted by city gate volume by dividing by 1 minus the unaccounted for factor) subtracted from the sum of the supplier’s daily requirement deliveries plus any allocated peakshaving. The customer class true-ups will be summed and the total will be supplier’s true-up for the month. The supplier’s true-up will reflect their daily requirement deliveries and actual customer usage from the calendar month 2 months prior. This is due to the time required to get actual metered readings. For example: if a customer’s meter is read on June 15 th the reading will have actual usage from May and June, then on July 15th actual usage will be for June and July. Therefore we must wait until the August true-up to process total actual usage for the calendar month of June. Each supplier’s monthly true-ups will be summed for a 12-month period to determine their annual true-up. The 12-month period will include the June true-up for April deliveries and usage through the May true-up for March deliveries and usage. BGE will adjust each supplier’s Daily Requirement for 122 days (the number of days in June, July, August and September) during the summer months (Jun – Sep) to reconcile the annual true-up volume. The Daily Requirement adjustment is calculated by dividing the annual true-up volume by 122. Over the next 122-days, beginning on June 1, this adjustment would be added to (for an accumulated under-delivery) or subtracted from (for an accumulated over-delivery) the Daily Requirement calculated for the respective supplier. The following are examples of the calculation of the Daily Requirement Adjustment. Note: Annual true-up volumes are calculated on the 3rd workday of May and includes deliveries from April of the previous year to March of the current year. Page 9 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Overdelivery (Daily Requirement = 1,000 Dth) Supplier overdelivered by 10,500 Dth over the prior 12-month period. Daily Requirement Adjustment = 10,500 Dth / 122 days = 86 Dth Adjusted Daily Requirement = 1,000 Dth - 86 Dth = 914 Dth Underdelivery (Daily Requirement = 1,000 Dth) Supplier underdelivered by 8,500 Dth over the prior 12-month period. Daily Requirement Adjustment = -8,500 Dth / 122 days = -70 Dth Adjusted Daily Requirement = 1,000 Dth + 70 Dth = 1,070 Dth IV. Parking and Balancing Service BGE operates a “paper pool” behind its City Gate to provide a Parking and Balancing Service for Suppliers serving Daily Requirements customers. A. Parking Service Parking is a service which provides for the receipt by BGE of gas quantities delivered by the Supplier to the Company’s City Gate. This includes the holding of the parked gas by BGE and the return of the parked gas upon nomination by the Supplier, provided that BGE is not obligated to return the parked gas on the same day the gas is parked. B. Balancing Service The Supplier’s deliveries to the Company’s City Gate are balanced with the actual unaccounted-for gas adjusted use of gas by the Daily Requirements customers served by the Supplier. Any accumulated net difference between the Supplier’s deliveries and customers’ actual use for the 12 months ended March of each year will be divided by 122 days to yield the adjustment applied to the Supplier’s Daily Requirement for the upcoming four month period June through September. Any remaining amount due to rounding will be either added to or subtracted from the Suppliers’ accumulated true-up for the next 12-month period ending March. If a Supplier ceases participation in the Daily Requirements Service, any accumulated net difference between the Supplier’s deliveries and customers’ actual use as of the last day of participation is an adjustment to the amount of gas parked by the Supplier. In the event a Supplier’s accumulated net difference between the Supplier’s deliveries and customers’ actual use becomes large enough during the course of the 12 month period that, in BGE’s judgment, it could adversely impact the Supplier’s summer Daily Requirement, BGE will contact the Supplier to mutually arrange for an adjustment to the amount of gas parked by the Supplier. C. Pool Capacity Allocation At the beginning of each month, BGE will allocate line pack pool capacity to DRS suppliers based on their customer population. Average pool capacity allocations for each Customer Class are shown below. Avg Pool Allocation (Dth) Customer Class Page 10 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Residential non-heating (D) Residential heating (DH) Commercial non-heating (C) Commercial heating (CH) Commercial annual usage > 15,000 therms (CLX) D. 10.6 21.3 33.1 72.4 388.9 Inventory Allocation Once the Pool Capacity Allocation is complete, inventory will be allocated to suppliers based on their customer population. The inventory allocated for converting customers is based on the current inventory held for those customers. BGE will maintain operational control of the nonotice aspect for balancing purposes. The DRS supplier has an implied no-notice service in that the requirement will not change after 9:00 AM regardless of the actual system load. E. Injections and Withdrawals All DRS Suppliers must actively nominate gas into and out of the pool. Pool nominations can only be made prior to 2:00 PM (EST) for the current day. These nominations will consist of a blend of 82% East Pool and 18% West Pool during the winter months, and individual pools during the summer months. DRS Suppliers will be subject to the same restrictions as BGE. These restrictions for both the winter and summer seasons are listed below. E.1 Winter Season The Winter Season is defined as November through March. a. Inventory Withdrawal Ratchets and Injection Rights Winter Withdrawal Rights (Capacity) Inventory (I) Level Daily Withdrawal I > 35% 1.37% 35% > I > 20% 1.10% 20% > I > 10% 0.89% I < 10% 0.68% Winter Injection Rights (Capacity) Month Month Max Daily Max Nov 6.6% 0.22% Dec 10.7% 0.36% Jan 10.7% 0.41% Feb 10.7% 0.41% Mar 10.7% 0.41% Note that the withdrawal ratchets are based on the level of inventory. Pool withdrawal capability decreases late in the season. The first withdrawal ratchet engages when the inventory level drops to 35%. The minimum inventory level in January is 38% (see chart below). Therefore, withdrawal ratchets cannot engage until the month of February. The injection rights are based on the month of the year. There are daily limits and monthly limits. Typically the daily limit is the primary restriction. For Page 11 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL example, in the month of January a supplier could inject gas for 26 days at 0.41% of capacity (10.7/.41 = 26.097 days). As shown in the table above, the most restrictive injection month is November. The least restrictive months for injections are Jan, Feb, and Mar. b. Inventory Envelopes Winter Inventory Envelope (Capacity) Month Max Inv Min Inv Nov 1 95% 90% Nov 100% 49% Dec 100% 40% Jan 87% 38% Feb 55% 20% Mar 41% 0% Mar 31 30% 0% Expected Inventory Allocation for 1st of Month Month Inventory Nov 95% Dec 90% Jan 70% Feb 41% Mar 20% c. Maximum Withdrawal and Injection Volumes (by month, by day) Daily maximum withdrawal volumes are a function of inventory. As the inventory decreases, the daily maximum withdrawal volume will also decrease based on the daily withdrawal rights as depicted in the Winter Withdrawal Rights table. Daily and monthly maximum injection volumes are a function of the daily and monthly maximum injection rights, depicted in the Winter Injection Rights table. Monthly maximum injection volumes could further be limited by the amount of empty pool capacity. For example, if inventory were 95% in November, then the monthly maximum injection would only be 5% rather than 6.6%, since there cannot be more than 100% inventory. E. 2 Summer Season The summer season is defined as April through October. a. Inventory Injection and Withdrawal Rights Summer Injection Rights (Capacity) East Month Month Max Daily Max Apr 15% 0.60% May 20% 0.80% Jun 20% 0.80% Jul 20% 0.80% Page 12 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Aug Sep Oct 20% 13% 7% 0.80% 0.52% 0.28% Summer Withdrawal Rights (Capacity) East Month Daily Max Apr 0.68% May 0.68% Jun 0.68% Jul 0.68% Aug 0.68% Sep 0.68% Oct 1.37% Summer Injection Rights (Capacity) West Inventory Level Daily Injection GE 0% & LE 50% 0.56% GE 50% 0.47% Please note, there are no summer withdrawal rights available from the West pool. The East pool allows withdrawals at 50% of full withdrawal capability from April through September. In October full withdrawals are available from the East pool. The East pool has daily and monthly injection restrictions in the summer months also. Maximum injection capability occurs in May, June, July, and August. Injection capability decreases in September and October as the line pack pool is filled. The West pool has one injection ratchet. It engages when inventory reaches 50% of capacity, and decreases the amount of gas that may be injected each day. b. Inventory Envelopes Summer Inventory Envelope (Capacity) East Month Max Inv Min Inv Apr 1 30% 0% Apr 40% 0% May 60% 0% Jun 60% 15% Jul 80% 35% Aug 85% 55% Sep 98% 75% Oct 100% 86% Oct 31 95% 90% Summer Inventory Envelope (Capacity) West Month Max Inv Min Inv Page 13 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Apr 1 Apr May Jun Jul Aug Sep Oct Oct 31 30% 52% 66% 81% 95% 95% 95% 95% 95% 0% 0% 0% 20% 36% 53% 67% 80% 90% Expected Inventory Allocation for 1st of Month Month Inventory Apr 10% May 13% Jun 26% Jul 45% Aug 65% Sep 78% Oct 90% c. Maximum Withdrawal and Injection Volumes (by month, by day) Daily maximum withdrawal volumes from East pool vary from month to month. Typically the daily maximum withdrawal is 0.68% of capacity, except in October where the daily maximum withdrawal rises to 1.37% of capacity. This is depicted in the Summer Withdrawal Rights –East table. There are no withdrawal rights available from the West pool during the summer months. Daily and monthly maximum injection volumes into the East pool are a function of the daily and monthly maximum injection rights, depicted in the Summer Injection Rights – East table. Monthly maximum injection volumes into the East pool could further be limited by the amount of empty pool capacity. For example, if inventory were 95% in August, then the monthly maximum injection would only be 5% rather than 20%, since there cannot be more than 100% inventory. Daily maximum injection volumes into the West pool are a function of inventory level. As the inventory level increases, the daily maximum injection volume decreases as depicted in the Summer Injection Rights – West table. F. Penalties Suppliers are subject to performance-related penalties. A supplier is subject to penalty if they do not manage their pool account(s) properly and are above the maximum inventory levels or below the minimum inventory levels. Below Minimum Inventory Suppliers must remain above the Minimum Inventory levels each month. The Below Minimum Inventory volume subject to penalty will be equal to the minimum inventory volume minus the inventory volume. During the winter months (Nov – Mar), no penalties will be assessed. However, all withdrawal rights will be eliminated. During the summer months (Apr – Oct), supplier’s will be charged $5.00 per Dth on the deficit and also be required to purchase the deficit from other pool holders. Page 14 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Above Maximum Inventory (Failure to Meet Monthly Turns) Suppliers must remain below the Maximum Inventory levels each month. The Above Maximum Inventory volume subject to penalty will be equal to the inventory volume minus the maximum inventory volume. The gas volume subject to penalty will be cashed out and returned to BGE. The transaction price shall be the lower of 80% of Transco Zone 6 for nonNew York deliveries or 80% of the BGE Pool WACOG. November 1 Suppliers must meet the (beginning) November 1 inventory range of 90% to 95% of capacity in both the East and West Pools. The November 1 Inventory volume subject to penalty will be equal to the minimum inventory volume (90% of capacity) minus the inventory volume. Supplier’s will be charged $5.00 per Dth on the deficit and also be required to purchase the deficit from other pool holders. G. POOL Screen The purpose of the Pool Activity screen is to nominate pool injections and withdrawals. The Pool Activity screen is also used to calculate inventory rights. These rights include the daily maximum withdrawal and injection volumes, and the monthly maximum withdrawal and injection volumes (these volumes do not include the shrinkage factor). In addition, the Pool Activity screen displays the daily DRS requirement, with the date and time the requirement was last updated by the system. The daily requirement can change up to 9:00 AM for the gas day beginning at 10:00 AM. G. 1 Instructions for Entering Pool Injections and Withdrawals The following are the instructions to be followed when nominated Pool Injections and/or Pool Withdrawals on the Pool screen in DSWeb. Pool Injections Go to the POOL screen. Input the nominated pool injections for each of the five respective days displayed on the screen. Check that the pool injections do not exceed the smaller of the Daily Max or Monthly Limit for Injections for each respective day. Once all of the pool injections have been nominated, click the Save or Calc button to recalculate the future pool inventory and rights. Save the nominations when finished. The injections that have been nominated will appear as read-only on the Destinations Screen. Pool Withdrawals Go to the POOL screen. Input the nominated pool withdrawal for each of the five respective days displayed on the screen. Check that the pool withdrawals do not exceed the smaller of the Daily Max or Monthly Limit for each respective day. Page 15 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Once all of the pool withdrawals have been nominated, click the Save or Calc button to recalculate the future pool and inventory rights. Save the nominations when finished. The withdrawals that have been nominated will appear as read-only on the Sources Screen. G. 2 Fields on the POOL Screen Note: (All volumes are displayed in Dekatherms) The following are examples of how the POOL screen will appear in DSWeb. Both the Winter POOL Screen and the Summer POOL Screen are depicted. Page 16 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Winter POOL Screen Page 17 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Summer POOL Screen Date – The date for each of the five days, that are available for inventory pool injection and withdrawal nominations. Blend – Indicates a blend of capacity during the winter months. (82% East, 18% West) Beginning Inventory – The current inventory position for each of the five respective days displayed on the screen. Note: The first day displayed includes shrinkage, while the remaining four days do not include shrinkage. Injection – The amount of gas the DRS supplier has nominated for injection into the pool for each of the respective days. This amount may not exceed the smaller of the Daily Max or Monthly Limit for the respective day. Daily Max – The maximum daily pool injection rights for each of the respective days. Monthly Limit – The maximum net injection for the month. Note: This limit will change each day due to pool activity. Withdrawal – The amount of gas the DRS supplier has nominated for withdrawal from the pool for each of the respective days. This amount may not exceed the smaller of the Daily Max or Monthly Limit for the respective day. Page 18 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL Daily Max – The maximum daily pool withdrawal rights for each of the respective days. Monthly Limit – The maximum net withdrawal for the month. Note: This limit will change each day due to pool activity. DRS Requirement – The amount of gas that must be delivered to the BGE city gate for each of the respective days. This gas can be delivered via a flowing pipeline, BGE allocated pool withdrawal, or allocated pool injection. BGE has until 9:00 AM to finalize this requirement for the gas day starting at 10:00 AM. Total Sources – The sum of all pipeline contracts and pool withdrawals for the respective day. Total Destinations – The sum of all customer nominations (including DRS) and pool injections for the respective day. Month/Year – Month and Year for respective inventory envelope information. During a monthly crossover, this information would appear for the current as well as the next month. Max DR – The maximum daily requirement for the respective month, based on the supplier’s current customer mix. This number will be populated for the next month, five days prior to the beginning of that month. Cap – The line pack pool capacity allocated for the respective month, based on the supplier’s current customer mix. Max Inv – The maximum pool inventory allowed for the respective month. This is determined by multiplying the maximum envelope percentage by the allocated pool capacity. (Max Envelope % * Cap) Min Inv – The minimum pool inventory allowed for the respective month. This is determined by multiplying the minimum envelope percentage by the allocated pool capacity. (Min Envelope % * Cap) Note: The next month’s Max DR, Cap, Max Inv and Min Inv are preliminary and displayed in red prior to the 17th workday of the month. During this time, these volumes may change if the number of customers change for the following month. This estimate is used to help the supplier plan their pool inventory, so they stay within the pool envelope. After the 17th workday all customer changes are finalized. Therefore, the next month's Cap, Max Inv and Min Inv will be actual, and appear in blue. Last DRS Update – The last time the Daily Requirement for the next five days has been updated. Calc – The calc button updates the Beginning Inventory and Monthly Limits without saving the data. Save – The save button saves the changes made to the pool. Note: The save button does not submit the pool nominations to BGE. Page 19 BALTIMORE GAS AND ELECTRIC COMPANY DAILY REQUIREMENTS SERVICE (DRS) PROCEDURES MANUAL G. 3 Pool Activity Report The purpose of the Pool Activity report is to display daily pool activity for each DRS Supplier for all pipelines. ======================= POOL ACTIVITY REPORT ======================= Report Period: 01-Mar-2000 - 31-Mar-2000 Report Date: 03/04/2000 19:03 Supplier: TEST SUPPLIER -------------------------------------------------------------------------------------------------------Daily Total All Pipelines for MAR-2000 -------------------------------------------------------------------------------------------------------Date In Field Net City City Gate Withdrawal City Gate Injection In Field Beginning Gate Nominated Shrinkage Nominated Shrinkage Pool Inventory Injection/ Withdrawal Injection Adjustments Withdrawal 01-MAR-2000 34620 -150 -150 -4 0 0 0 02-MAR-2000 34466 -200 -200 -4 0 0 0 03-MAR-2000 34262 -210 -210 -5 0 0 0 04-MAR-2000 34047 0 0 0 0 0 0 -------------------------------------------------------------------------------------------------------Total for MAR-2000 -560 -560 -13 0 0 0 --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Daily Total All Pipelines for FEB-2000 -------------------------------------------------------------------------------------------------------Date In Field Net City City Gate Withdrawal City Gate Injection In Field Beginning Gate Nominated Shrinkage Nominated Shrinkage Pool Inventory Injection/ Withdrawal Injection Adjustments Withdrawal 28-FEB-2000 36678 100 0 0 100 0 0 29-FEB-2000 36778 -175 -175 -5 0 0 0 -------------------------------------------------------------------------------------------------------Total for FEB-2000 -75 -175 -5 100 0 0 -------------------------------------------------------------------------------------------------------- Common Exception Errors You Cannot have an Injection and Withdrawal on the Same Day – A pool Injection and Withdrawal have been entered for the same day. The Injection Amount Cannot Exceed the Daily Maximum – The daily pool Injection has exceeded the Daily Max. The Injection Amount Cannot Exceed the Monthly Limit – The daily pool Injection has caused the Monthly Limit to be exceeded. The Withdrawal Amount Cannot Exceed the Daily Maximum – The daily pool Withdrawal has exceeded the Daily Max. The Withdrawal Amount Cannot Exceed the Monthly Limit – The daily pool Withdrawal has caused the Monthly Limit to be exceeded. Page 20
© Copyright 2026 Paperzz