TITANIUM / PTEF / HAP Spring Total CODE TITANIUM / PTEF / HAP

TITANIUM / PTEF / HAP Spring Total
CODE
CODE TAP 07.71
TI: Titanium ASTM F67 Gr. 2 HAP; Porous Hydroxylapatite; PTFE
HAP FLANGE – HAP flange can be placed directly in touch with tympanic
membrane.
TYMPANUM FIXATION – The porosity of the prosthesis allows fixation
to the tympanum thanks to two characteristics: A physical link is created
when fibroblasty enters the pores and a chemical link is created thanks to
hydroxilapatite bioactivity.
ARMONIC TITANIUM SPRING – the soft movement of the spring allows
the compensation of the tympanic membrane movement.
The table shows the maximum range between the extended and compressed version.
After mesuring using the microsurgical measuring device, cod. 02.14,
it is advised to use the prosthesis with the same length. The prosthesis
oscillatory movements allows an easy insertion of the prosthesis under the
malleus handle.
A small groove is in place for the malleus handle. If the malleus handle is
not available, the flange of the prosthesis can be put directly in touch with
the tympanic membrane. The smooth edges of the groove do not create
decubitus.
Il gambo in PTFE della protesi totale TAP 07.71 può essere accorciato con
lama di bisturi previa misurazione.
Wire ø: 0.20 mm
PTFE ø: 0.6 mm
Packaging
Dispenser box containing 6 sterile,
individually packaged implants.
CODE
TAP 07.71
L (mm)
Ext.
Comp.
trimmable from
trimmable from
8.00 to 4.00
7.30 to 3.30
commpression range 0.7 mm
TITANIUM / PTEF / HAP Spring Partial
CODE
CODE PAP 07.60
TI: Titanium ASTM F67 Gr. 2 HAP: Porous Hydroxylapatite
HAP FLANGE – HAP flange can be placed directly in touch with tympanic
membrane.
TYMPANUM FIXATION – The porosity of the prosthesis allows fixation
to the tympanum thanks to two characteristics: A physical link is created
when fibroblasty enters the pores and a chemical link is created thanks to
hydroxilapatite bioactivity.
ARMONIC TITANIUM SPRING – the soft movement of the spring allows
the compensation of the tympanic membrane movement.
The table shows the maximum range between the extended and compressed version.
After mesuring using the microsurgical measuring device, cod. 02.14,
it is advised to use the prosthesis with the same length. The prosthesis
oscillatory movements allows an easy insertion of the prosthesis under the
malleus handle.
A small groove is in place for the malleus handle. If the malleus handle is
not available, the flange of the prosthesis can be put directly in touch with
the tympanic membrane. The smooth edges of the groove do not create
decubitus.
Wire ø: 0.20 mm
Ti Bell inside ø: 1,10 mm
Ti Bell outside ø: 1,20 mm
Packaging
Dispenser box containing 6 sterile,
individually packaged implants.
CODE
PAP 07.60.250
PAP 07.60.300
PAP 07.60.350
PAP 07.60.400
PAP 07.60.450
PAP 07.60.500
Ext.
2.50
3.00
3.50
4.00
4.50
5.00
commpression range 0.7 mm
L (mm)
Comp.
1.80
2.30
2.80
3.30
3.80
4.30