AXS-100 - Visonic

AXS-100
Application Note
Parking
1. General Information
Thank you for choosing the Visonic Networks AXS-100 proximity access control system. We are confident that this
product will serve your needs for years to come. The Visonic Networks AXS-100 is an electronic access control
system for controlling two doors. Eight controllers can be networked together to control a total of 16 doors.
The AXS-100 access control system can be used to control the entry and exit of parking lots that includes entry &
exit barriers. In addition, the system can counts the number of cars that are inside the parking area in real time, and
to prevent the entry of additional cars when the number of the cars in the parking lot exceeds a predefined limit.
This application note will guide you, step by step, in the simple programming sequence of the AXS-100 controller.
For general installation information, please see the AXS-100 Installation Instruction document.
Prox.
Reader
Traffic
light
Entrance barrier
Road sensor
PARKING LOT
Prox.
Reader
Exit barrier
F
2
AC fuse 3.15A
Battery fuse 3.15A
LD3 (green LED)
ext. batt. charged
F
3
LD2 (red LED)
Power ON
BAT-
AC
BAT+
Red PWR
Black GND
Green TX
White RX
READER 1
battery
+
holder
PWR
GND
Entry Side
RTE
AC
AXS-100
READER 2
TX
RX
Exit Side
GND
RTE
GND
DPOS
DPOS
RELAY 2
RELAY 1
GND
GND
LD4 (red LED) alarm
relay activated
PWR
NO
COM
NC
PWR
NO
COM
NC
LD5 (green
LED) output
relay activated
LD1 (green LED)
output relay
activated
DOOR 2
DOOR 1
IN1
GND
DIP Switches
EPROM
IN1
GND
IN2
IN2
Figure 1 – Parking Lot Application
Red
Black
Green
White
2. Operation Modes
The AXS-100 can work in one of three relevant modes for the parking lot application.
Mode-1: Two barriers and two readers with hard Anti Pass-Back. (Figure 1)
Hard anti pass-back means that if a tag is presented to the entrance reader, this tag cannot be represented to the
entrance reader again until this tag is presented to the exit reader, and vice versa.
Mode-3: Two barriers and two readers with soft Anti Pass-Back. (Figure 1)
Soft anti-pass-back means that if a tag is presented to the entrance reader, this tag cannot be represented to the
entrance reader again until this tag is presented to the exit reader. The quantity of tag presentation to the exit reader
is not limited.
Mode-4: One barrier and two readers with soft Anti Pass-Back.
This mode is useful for small parking lots, where the same barrier serves both entry and exit. In this mode the soft
anti-pass-back is active.
Other modes of operation may be used for different configurations. See the AXS-100 User Guide for more details.
3. Basic Programming
In order to program the Operation Mode, please follow the following steps:
Enter
ENTER PASSWORD
XXXX
Enter
Enter
The display will be:
SETUP
EDIT KEYS
Enter controller No. (e.g. 1)
EDIT REGISTERS
LOCAL SETUP
Enter
CONTROLLER
1
4 times
Select operation mode (e.g. 7)
Enter
MODE
7
Enter
Esc
Esc
Note: Mode list is attached
to the AXS-100 door.
Figure 2 – Setting Address and Operation Mode
To check the controller’s operation mode and address, press the "9" button while the controller is in idle mode (while
the controller LCD screen shows only the date and time, as shown below).
2 7
/ 0 1
0 8 : 3 1 : 1 7
4. Counting and Limiting
Cars Number
The AXS-100 enables to count and limit the number of cars in the parking. Each entry and exit is counted, and when
the number of cars reaches a predefined number, “threshold”, the controller will prevent additional entry. An entry
will be possible only after a car is exit.
4.1 Counters
Two registers (counters) should be set:
Register "0": Counts the number of cars in the parking. Each entry increases the counter by one and each exit
decreases the counter by one.
Register "1": Capacity threshold. Maximum number of cars allowed in the parking.
To set these registers, perform the following steps on the controller keypad:
Enter
ENTER PASSWORD
XXXX
2975
>EDIT REGISTERS
LOCAL SETUP
Type the desired value
Enter
Enter
Type the register #
Enter
Enter
>SETUP
EDIT KEYS
ESC
27/02
ESC
Enter
17:49:21
4.2 Traffic Lights
A traffic light can be added to this application for letting the drivers know when parking is full. To activate this traffic
light utility, two flags must be set:
1. Flag-7 in flags setup-1 (must be "off")
2. Flag-6 in flags setup-4 (must be "on")
The traffic-lights control should be connected in the Auxiliary output (Figure1).
To set these flags, perform the following actions:
Flag-7 in flags setup-1:
Enter
ENTER PASSWORD
XXXX
2975
>DATE TYPE
DATE/TIME
SETUP FLAGS
------78
Press on “0” to disable the flag
or “1” to enable it
Enter
EDIT REGISTERS
>LOCAL SETUP
1
Enter
>SETUP
EDIT KEYS
Enter
Press on the right arrow
till the number seven will
blink
Press ENTER repeatedly
till the display will show
“LOCAL SETUP”
Enter
APB RESET HOUR
99:00
SETUP FLAGS
------78
ESC
27/02
1
ESC
17:49:21
Flag-6 in flags setup-4:
Enter
ENTER PASSWORD
XXXX
2975
>DATE TYPE
DATE/TIME
Enter
>SETUP
EDIT KEYS
EDIT REGISTERS
>LOCAL SETUP
SETUP FLAGS
------78
1
Enter
Enter
Enter
Enter
APB RESET HOUR
99:00
SETUP FLAGS
------78
Enter
4
Press on the right arrow repeatedly till the
blinking cursor will be on the 6th flag
SETUP FLAGS
------78
Press ENTER repeatedly
till the display will show
“LOCAL SETUP”
4
Enter
ESC
ESC
27/02
Press on “0” to disable the flag or
“1” to enable it
17:49:21
4.3 Road Sensor
In some cases, there is a need to know if a car is actually entered the parking and not just a card was presented to
the reader. In this kind of application, "Road Sensor" can be used for counting the vehicles. The road sensor needs
to be installed after the barrier (see figure 1). In this case the vehicle will be counted and marked in the anti PassBack table only after it crossed the barrier.
To activate this function, flag-2 in flags setup-3 need to be "on". Setting this flag is performed as follows:
Enter
ENTER PASSWORD
XXXX
2975
>DATE TYPE
DATE/TIME
Enter
>SETUP
EDIT KEYS
EDIT REGISTERS
>LOCAL SETUP
SETUP FLAGS
------78
1
Enter
Enter
Enter
SETUP FLAGS
-----67-
Enter
APB RESET HOUR
99:00
3
Press on the right arrow repeatedly till the
blinking cursor will be on the 2nd flag
SETUP FLAGS
-----67-
3
Enter
Press ENTER repeatedly
till the display will show
“LOCAL SETUP”
Press on “0” to disable the flag or
“1” to enable it
ESC
ESC
27/02
TECHNICAL DEPT.:
Tech. Support email:
39 HAMELACHA ST. CARMIEL 20100 ISRAEL TEL: 972 4 9081115 FAX: 972 4 9081116
[email protected]
VISONIC INC. (U.S.A.):
10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. TEL: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISACCESS LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE, BIGGLESWADE, BEDS. SG18 8QS. TEL: (01767)600857 FAX: (01767)601098
INTERNET:
www.visonicnet.com
Visonic Networks Ltd. 2003
AXS-100 Application Note DE6280AN
(REV. 0, 02/2003)
17:49:21