the low-carbon steam plant room brochure.indd

www.spiraxsarco.com / uk
The low-carbon steam plant room
First for Steam Solutions
E X P E R T I S E
S O L U T I O N S
S U S T A I N A B I L I T Y
t h e
l o w - c a r b o n
s t e a m
p l a n t
r o o m
The low-carbon steam plant room
The Spirax Sarco low-carbon steam plant room has been developed to eliminate many of
the issues experienced within traditional steam plant rooms.
It has been designed to help you meet your CO2 and energy reduction targets, achieving typical savings of around 10%. It will also dramatically reduce
your maintenance requirements and eliminates the need for bi-annual insurance inspections, thus improving health and safety. Combine this with our
knowledgeable team of specialists and we will ensure we help you find the most effective way of improving your business performance. Our experts
will help you every step of the way.
www.spiraxsarco.com / uk
The traditional steam plant room
Typical steam system:
• Flash steam loss
• Cost of safety valve vents
• Health and safety maintenance issues
with tube bundle handling
• Risk of Legionella in stored water
• Costs of separate condensate pump and vent
• Waterhammer damage in calorifiers
• Mandatory insurance inspections with
shell and tube calorifiers
• Inefficient use of plant room space
• Maintenance costs of PRV set
DP17
DP17
100
0
100
0
0
100
100
0
0
100
100
0
0
100
100
0
0
100
100
0
0
100
100
0
0
100
0
100
100
0
0
100
Constant speed pumps
• High energy costs of constant speed pumps
t h e
l o w - c a r b o n
s t e a m
p l a n t
r o o m
The low-carbon plant room
Benefits of a low-carbon steam plant room
• Energy, water and CO2 reduction - Flash steam is eliminated and condensate sub-cooled
• Directly connected to a boiler pressure steam main - No pressure reducing stations required
• Waterhammer is eliminated - Installation of an automatic pump trap
• No separate condensate pump required
• Legionella risks are reduced - Instantaneous operation, no storage cylinders required
• Quick installation
• Reduced operating costs
• Reduced maintenance requirements
• No manual handling - No strip down for insurance inspection
• Compact design - Reduced plant room space required
• Variable speed pumps supplied as a packaged solution
www.spiraxsarco.com / uk
The low-carbon plant room
Boiler pressure steam
AT
ALM
EV1
OP1
EV2
OP2
EV3
MAN
EV4
RUN
HLD
x60
1
SX100
SET TO
PRG
MODE
PROF
RUN/HOLD
Instantaneous
DHW
Spirax
EasiHeatTM
AT
ALM
EV1
OP1
EV2
OP2
EV3
MAN
EV4
RUN
HLD
x60
1
SX100
SET TO
LTHW
Spirax EasiHeatTM
PRG
MODE
PROF
RUN/HOLD
Constant
temperature
circuit
Variable
temperature
circuit
Shunt
SPIRAX SARCO
SPIRAX SARCO
MADE IN UK
MADE IN UK
AT
ALM
EV1
OP1
EV2
OP2
EV3
MAN
EV4
RUN
HLD
x60
1
SX100
SET TO
PRG
MODE
PROF
RUN/HOLD
Instantaneous
DHW
Spirax
EasiHeatTM
AT
ALM
EV1
OP1
EV2
OP2
EV3
MAN
EV4
RUN
HLD
x60
1
SX100
SET TO
PRG
MODE
PROF
RUN/HOLD
Variable speed drive pump skid
SPIRAX SARCO
MADE IN UK
SPIRAX SARCO
MADE IN UK
LTHW
Spirax EasiHeatTM
100% sub-cooled direct condensate return
t h e
l o w - c a r b o n
s t e a m
p l a n t
r o o m
Spirax EasiHeatTM
The Spirax EasiHeatTM is a compact and energy efficient heat transfer solution, that will deliver instantaneous
hot water, on demand, for a full range of domestic and process applications.
Supplied as a fully assembled and tested unit, the Spirax EasiHeatTM is delivered to site ready to be connected to your utilities. We will manage the entire process from
assessing your requirements, through to installation, start-up and commissioning.
Case study
Spirax EasiHeatTM features:
• Compact design
• Low cost of ownership
• Standardised design with flexible option packages
• Highly efficient plate heat exchanger
• Condensate drainage solutions to suit all plant
and process conditions
• Pre-assembled and tested
• Precisely matched controls
• Touch screen controls
St George’s Hospital in Tooting is saving £45,000 per year by upgrading the heating and hot water
systems in one of its plant rooms to Spirax EasiHeat™ plate heat exchanger packages.
www.spiraxsarco.com / uk
Low-carbon pump solution
The low-carbon pump skid has been designed to complete the plant room. This solution enables the
heated water from the Spirax EasiHeatTM to be accurately distributed to the various sub-circuits within the
plant using low carbon footprint pumps.
The low carbon pump skid is supplied with twin head variable speed pumps and all associated ancillary equipment installed on each circuit. The unit can be further
enhanced, for optimum performance, by selecting the optional pressurisation unit and expansion vessel to remove the requirement for a feed and expansion system.
Low-carbon pump skid features:
• Shunt circuit
• Constant temperature circuits (up to 3 circuits)
• Variable temperature circuits (up to 3 circuits)
• Low loss header design
• Twin head variable speed Lowara pumps
• Expansion vessels
• Pressurisation unit and expansion vessel Optional extras
• Binder test points
• Pre-wired to isolators
For more information please contact one of our specialists:
Tel: 01242 535361
Email: [email protected]
Spirax-Sarco Limited, Charlton House, Cheltenham,
Gloucestershire, GL53 8ER, UK
T +44 (0)1242 521361
F +44 (0)1242 573342
E [email protected]
UK – LCSP 01