www.spiraxsarco.com / uk The low-carbon steam plant room First for Steam Solutions E X P E R T I S E S O L U T I O N S S U S T A I N A B I L I T Y t h e l o w - c a r b o n s t e a m p l a n t r o o m The low-carbon steam plant room The Spirax Sarco low-carbon steam plant room has been developed to eliminate many of the issues experienced within traditional steam plant rooms. It has been designed to help you meet your CO2 and energy reduction targets, achieving typical savings of around 10%. It will also dramatically reduce your maintenance requirements and eliminates the need for bi-annual insurance inspections, thus improving health and safety. Combine this with our knowledgeable team of specialists and we will ensure we help you find the most effective way of improving your business performance. Our experts will help you every step of the way. www.spiraxsarco.com / uk The traditional steam plant room Typical steam system: • Flash steam loss • Cost of safety valve vents • Health and safety maintenance issues with tube bundle handling • Risk of Legionella in stored water • Costs of separate condensate pump and vent • Waterhammer damage in calorifiers • Mandatory insurance inspections with shell and tube calorifiers • Inefficient use of plant room space • Maintenance costs of PRV set DP17 DP17 100 0 100 0 0 100 100 0 0 100 100 0 0 100 100 0 0 100 100 0 0 100 100 0 0 100 0 100 100 0 0 100 Constant speed pumps • High energy costs of constant speed pumps t h e l o w - c a r b o n s t e a m p l a n t r o o m The low-carbon plant room Benefits of a low-carbon steam plant room • Energy, water and CO2 reduction - Flash steam is eliminated and condensate sub-cooled • Directly connected to a boiler pressure steam main - No pressure reducing stations required • Waterhammer is eliminated - Installation of an automatic pump trap • No separate condensate pump required • Legionella risks are reduced - Instantaneous operation, no storage cylinders required • Quick installation • Reduced operating costs • Reduced maintenance requirements • No manual handling - No strip down for insurance inspection • Compact design - Reduced plant room space required • Variable speed pumps supplied as a packaged solution www.spiraxsarco.com / uk The low-carbon plant room Boiler pressure steam AT ALM EV1 OP1 EV2 OP2 EV3 MAN EV4 RUN HLD x60 1 SX100 SET TO PRG MODE PROF RUN/HOLD Instantaneous DHW Spirax EasiHeatTM AT ALM EV1 OP1 EV2 OP2 EV3 MAN EV4 RUN HLD x60 1 SX100 SET TO LTHW Spirax EasiHeatTM PRG MODE PROF RUN/HOLD Constant temperature circuit Variable temperature circuit Shunt SPIRAX SARCO SPIRAX SARCO MADE IN UK MADE IN UK AT ALM EV1 OP1 EV2 OP2 EV3 MAN EV4 RUN HLD x60 1 SX100 SET TO PRG MODE PROF RUN/HOLD Instantaneous DHW Spirax EasiHeatTM AT ALM EV1 OP1 EV2 OP2 EV3 MAN EV4 RUN HLD x60 1 SX100 SET TO PRG MODE PROF RUN/HOLD Variable speed drive pump skid SPIRAX SARCO MADE IN UK SPIRAX SARCO MADE IN UK LTHW Spirax EasiHeatTM 100% sub-cooled direct condensate return t h e l o w - c a r b o n s t e a m p l a n t r o o m Spirax EasiHeatTM The Spirax EasiHeatTM is a compact and energy efficient heat transfer solution, that will deliver instantaneous hot water, on demand, for a full range of domestic and process applications. Supplied as a fully assembled and tested unit, the Spirax EasiHeatTM is delivered to site ready to be connected to your utilities. We will manage the entire process from assessing your requirements, through to installation, start-up and commissioning. Case study Spirax EasiHeatTM features: • Compact design • Low cost of ownership • Standardised design with flexible option packages • Highly efficient plate heat exchanger • Condensate drainage solutions to suit all plant and process conditions • Pre-assembled and tested • Precisely matched controls • Touch screen controls St George’s Hospital in Tooting is saving £45,000 per year by upgrading the heating and hot water systems in one of its plant rooms to Spirax EasiHeat™ plate heat exchanger packages. www.spiraxsarco.com / uk Low-carbon pump solution The low-carbon pump skid has been designed to complete the plant room. This solution enables the heated water from the Spirax EasiHeatTM to be accurately distributed to the various sub-circuits within the plant using low carbon footprint pumps. The low carbon pump skid is supplied with twin head variable speed pumps and all associated ancillary equipment installed on each circuit. The unit can be further enhanced, for optimum performance, by selecting the optional pressurisation unit and expansion vessel to remove the requirement for a feed and expansion system. Low-carbon pump skid features: • Shunt circuit • Constant temperature circuits (up to 3 circuits) • Variable temperature circuits (up to 3 circuits) • Low loss header design • Twin head variable speed Lowara pumps • Expansion vessels • Pressurisation unit and expansion vessel Optional extras • Binder test points • Pre-wired to isolators For more information please contact one of our specialists: Tel: 01242 535361 Email: [email protected] Spirax-Sarco Limited, Charlton House, Cheltenham, Gloucestershire, GL53 8ER, UK T +44 (0)1242 521361 F +44 (0)1242 573342 E [email protected] UK – LCSP 01 © Copyright 2012 Spirax Sarco is a registered trademark of Spirax-Sarco Limited
© Copyright 2026 Paperzz