Straw Detector Status Michal Koval Straw Working Group 12 October 2015 Online Monitor screenshot from 11 Oct 2015 (run 3754) 2015-10-12 Straw Detector Status 2 Outline 1. Timeline summary since Prague meeting (Sep 2015) 2. Readout stability and current status 3. Future plans 2015-10-12 Straw Detector Status 3 Timeline Summary (1) • Prague meeting – starting point – All SRBs sending data with trigger matching firmware (few holes) – Firmware problem: data corruption • padding + repeated words + non-smooth channel activity profile • 4 Sep: first notice of HV module problem – No HV on view Y station 4 – “Module is bad” report in ISEG software – “Clear events” solves the problem, HV restored until next failure • 7 Sep: power-cut → SRB stopped sending data in-time • 8 Sep: SRB id 23 replaced, HV connector problem fixed • 9 Sep: New trigger manager firmware (TRGMv6) – Delay configuration fixed – SRB data sending to PC farm recovered – For the first time: no holes in the readout 2015-10-12 Straw Detector Status 4 Timeline Summary (2) • 15 Sep: frontend interface firmware test (FEv9) – Attempt to solve data synchronization – Not successful, reverted back to FEv7 • 16 Sep (MD): HV module replacement (station 4, view Y) – Stable, but with a problem on channel 13 (always “ramping”) • 16 Sep (MD): noise scan + new threshold settings • 18 Sep: connection between covers and SRBs lost – Reason unknown (power glitch?) – SRB stopped to send data in-time – Power cycle on VME crates (+ setup) solved the problem • 21 Sep: connection to one cover lost and recovered 2015-10-12 Straw Detector Status 5 Timeline Summary (3) • 23 Sep (MD): noise scan + new threshold setting • 23 Sep: event manager (trig. match.) firmware test (EMv5) – Packets not OK → PC farm crash; firmware reverted • 24 Sep: 50% beam intensity, Straw readout OK (no crashes) • 24 Sep: event manager (trig. match.) firmware test (EMv5) – Firmware got stuck; firmware reverted to v4 • 29 Sep: Beam problem, QUAD 043.169 failure – Cover connectivity lost (all stations) • 30 Sep (MD): VME crate power cycle (+ setup) → everything recovered 2015-10-12 Straw Detector Status 6 Timeline Summary (4) • 1 Oct: event manager (trig. match.) firmware test (EMv5.1) – Padding and repeated words in ethernet part fixed • 1 Oct: Power cut →configuration lost • 2 Oct: EMv5.1 firmware installed on 31/32 SRBs – SRB id 1 did not work with new firmware – Padding fixed, repeated words at the end of packet fixed – Data quality improved, still major data corruption (non-smooth profile) • 6 Oct: new trigger manager firmware (TRGMv7) installed – Important fix of trigger FIFO reset → stability improved • 9 Oct: event manager (trig. match.) firmware (EMv6) – Most of the data corruption problem solved – Works very well at 40% intensity 2015-10-12 Straw Detector Status 7 Online Monitor screenshot from 11 Oct 2015 (run 3754) 2015-10-12 Straw Detector Status 8 Readout Stability • When the system is set up and no external factor (beam, powercut problem) intervenes, it is stable • However, it is quite difficult to set up the system properly – Usually the procedure involves power cycle on LV of covers and/or SRB VME crates – After SRB power cycle: • Links not aligned automatically, sometimes data from some front-end chips are not coming, triggers not sent correctly from TRGM • Latency scan is needed cycle due to random shifts of trigger-data offset: not understood at the moment – We are going to work on proper reset procedure • Cover T0 shifting at “start run” – Can be recovered offline by measuring Cover T0 for each run – Not possible to use in trigger algorithms (L1, L2) → must be fixed 2015-10-12 Straw Detector Status 9 Current Status and Future Plans • Straw readout system is now in quite good shape and should work at higher beam intensities – Missing feature (Peter is working on it): MEP factor > 1, important for PC farm stability at high L0 rates • Foreseen stability improvements: – FE interface firmware (v9), new Cover firmware • Thresholds are set according to the equal 100Hz noise rate on all channels – Full noise scan information is saved for analysis and future threshold setting procedure development – Threshold tests as discussed in Prague can be now performed 2015-10-12 Straw Detector Status 10
© Copyright 2026 Paperzz