The PERFORMANCE PLUS™ atmospheric gas water heaters are engineered for more hot water at a low operating cost Efficiency Longer Life .62 EF Premium grade anode rod provides long-lasting tank protection Performance FHR: 71 - 84 gallons High Altitude Compliant R ecovery rate is up to 40.4 gallons at a 90 degree rise, depending on model Diagnostic Valve S elf powered d iagnostic gas control valve for improved monitoring and service All models certified up to 6,000 ft. above sea level Some models certified up to 10,200 ft. above sea level, check factory for listings Plus… Easy to light – no matches required Low Emissions Temperature and pressure relief valve included M eets 40 ng/J NOx requirements Warranty E co-friendly burner, low NOx design Self-Cleaning F ights sediment and mineral build-up R educes fuel costs ag Di nostic valv e 9-Year limited warranty for tank and parts, 2-year full in-home labor warranty* *See written warranty for complete details Maintenance Free Burner System E xclusive air/fuel shut-off device M aintenance free – no filter to clean Combustion Shut-off System Low lead compliant Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. PERFORMANCE PLUS Atmospheric 40 and 50-Gallon Capacities Up to 40,000 Btu/h Flame Arrestor Plate Maintenance Free LEED Point = 1 See dimensions chart on back. 04/14 FORM NO. THD-P+HE Atmospheric Gas Specifications Gallon Model Fuel Type Description Capacity Number Gas Input Recovery in First Hour in Thous. G.P.H. Delivery Btu/h 90° Rise G.P.H. Ht. to Vent A Tank Height Diam. B C Ht. to Gas Conn. D Vent Water Conn. Ht. to Side Water Conn. Ship Size Center T&P Valve Size Weight E F G H (LBS) Energy Factor Natural Gas Tall 50 XG50T09HE40UO 40 40.4 84 62-3/4 59-1/4 21-1/2 14 3 or 4 8 52-1/2 3/4 165 0.62 Natural Gas Tall 40 XG40T09HE40UO 40 40.4 71 63-3/4 60-1/4 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.62 Natural Gas Short40 XG40S09HE38UO 3838.471 53-3/4 50-1/4 21-1/21438 44 3/4125 0.62 Liquid Propane Tall 50 XP50T09HE36UO 36 36.4 84 62-3/4 59-1/4 21-1/2 14 3 or 4 8 52-1/2 3/4 165 0.62 Liquid Propane Tall 40 XP40T09HE36UO 36 36.4 71 63-3/4 60-1/4 19-1/2 14 3 or 4 8 53-1/2 3/4 135 0.62 Liquid Propane Short40 XP40S09HE36UO 3636.471 53-3/4 50-1/4 21-1/21438 44 3/4125 0.62 Energy Factor based on D.O.E. (Department of Energy) test procedures. FLUE ANODE ROD H LEED Point = 1 H HOT WATER CONNECTION F E COLD WATER CONNECTION 3/4" N.P.T. RELIEF VALVE OPENING C A B 1/2" G D In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com 04/14 FORM NO. THD-P+HE
© Copyright 2026 Paperzz