Sincerely,

Date Published: March 2015
Version Control: EC-PS-ID v2
Product Specification Document
Date Published: March 2015
Version Control: EC-PS-ID v2
1.0
CONSOLE OVERVIEW
Limited only by your imagination, Identity™ is our premium console solution. Extremely
customizable, this console is Evans’ most flexible design and sets the industry standard for
performance and appearance. It is parametric in virtually all directions allowing it to be easily
configured to almost any layout. The Identity console displays a virtually unlimited series of
design options from fully enclosed to fully open, flat panel depth to full CRT depth, a complete
array of finishes and worksurface materials, adjustable worksurfaces to static surfaces and all
options in between. The open design of the Identity console allows for front and rear access for
servicing and for layout options that can span up to six feet without structural supports between
displays, allowing for displays to be set directly beside each other providing a continuous
information flow.
2.0
CONSOLE DESCRIPTION
A. The console shall have the following features and capabilities:
1. Modular configuration:
a. Cross sectional dimensions of the console can be parametrically extended or
compressed to accommodate a variety of display options.
b. Modular structural system supports full range of layouts and control room
configurations.
c. Open nature of the structural system, including the ruggedness and rigidity of
the structural components, contribute to the console’s ability to offer the most
spatially efficient footprint for a given suite of equipment.
2. Open nature of the structural system facilitates placement of displays in close
proximity to the operator, creating a ‘cockpit’ around the operator where the view
distances and reach distances are optimized to support a variety of tasks being
performed at the workstation.
3. Unlimited flexibility and options for customization, whether it is through unique
configurations, extensions, peninsulas, credenzas, or wall units.
4. Equipment accessibility:
a. Panel mounted devices shall be accessible via gas-piston lift assisted onepiece back and top panel in fully enclosed applications.
b. Alternate open or desktop design shall provide optimum access for servicing
operator interface devices while maximizing viewing and communication
openings.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
1
Date Published: March 2015
Version Control: EC-PS-ID v2
c.
d.
Hinged and/or removable lower panels shall provide superior access to
internally mounted equipment for installation and service.
Optional front or rear slide out access or door mounted processor
compartments offer maximum accessibility while minimizing console depth.
5. The highest level of equipment placement flexibility.
6. Manufacturer shall offer unlimited design options between fully enclosed or open
above worksurface level, which will allow for maximum functionality and
aesthetic design flexibility. Use of contemporary premium exterior finish
materials will ensure the ability to achieve a distinguished appearance that sets the
industry standard.
7. The console shall have the ability to have flat screen monitors and various desk
accessories mounted on a rear slatwall on desktop configurations. Standard
slatwall heights include 6” (153 mm), 12” (305 mm), and 18” (458 mm) and can
be combination slatwall and partition structure. The slatwall design can be
configured to accommodate equipment mounting on both sides.
8. All layouts (even custom) shall have the ability to be retrofitted. This can be done
at any point after installation with minimal part changes, allowing for the support
of future expansion and technology upgrades.
9. The option to be custom configured to accommodate a sit-to-stand option that
configures to recognized ergonomic standards or operating requirements.
10. Custom options will include manually operated hand cranks that offer a smooth
transition through +/- 2.5 in (63mm) from the standard 28.5 in (724mm) work
surface height. Other options will include an electric motor driven adjustable
work surface and a full console ‘sit–to–stand’ height adjustment feature.
11. The standard console shall be designed to comply with accepted Human Factors
of Design and applicable ergonomic standards including ANSI/BIMFA, CSA, and
ISO 11064.
12. All wood products milled or otherwise altered by manufacturers are to be certified
to be in compliance with the standards endorsed by the Forest Stewardship
Council (FSC) and controlled according to the requirements outlined in FSCSTD-40-005 FSC standard for company evaluation of controlled wood. The
company supplying the FSC-certified material shall be in possession of a valid
FSC chain of custody certificate issued by an FSC-accredited certification body
and shall submit a current copy of the certification with the proposal. Postdelivery, company must demonstrate that products are FSC certified by providing
vendor invoices. Invoices will contain the vendor’s Chain-of-Custody (COC)
number and identify each FSC certified product on a line-item basis.
13. The standard console shall be designed with a large ventilation grill placed in
such a way that generated heat can easily leave the console enclosure. Optional
ventilation fans can also be added if required to assist the natural convection air
currents in order to maintain optimum operating temperatures within the console
enclosure.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
2
Date Published: March 2015
Version Control: EC-PS-ID v2
14. The tasklighting system shall be a high color rendition index system with
adjustable intensity, and will be specifically designed for the console environment
to provide required light level at the work surface with no glare on the monitor
display area.
15. The console structure shall be continually tested at loading beyond normal
operating environments, which assures that the console structure and its
components are suitable for almost any application. Exterior finish materials are
selected for suitability for 24/7 environments.
16. Standard module sizes of 26 inches (660.4 mm), 48 inches (1,219.2 mm), 60
inches (1,524 mm), 72 inches (1,828.8 mm), and 24 inches (609.6mm) for radial
frames only.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
3
Date Published: March 2015
Version Control: EC-PS-ID v2
DESKTOP WITH SLATWALL
3.0
CONSOLE MANUFACTURER SPECIFICATIONS
A. Quality Assurance & Manufacturing Capability
1. Vendor shall demonstrate ISO 9001 certification as a measure of consistent
quality and performance.
2. Vendor shall have a Professional Engineer employed
3. Vendor shall have a Designated Architect employed
4. The manufacturer shall fully stage (assemble) all products prior to shipping to
ensure quality of fit and finish. In addition, the manufacturer will have an option
for a factory product sign off prior to product shipment. Photographs of
assembled consoles may be required in lieu of factory acceptance by the
purchaser.
5. The vendor shall have a minimum of fifteen (15) years experience specializing in
console design and fabrication.
6. The vendor for the control room furniture shall be a full manufacturer of product
including all design services, metalwork, woodwork and millwork to ensure
product consistency and lead times.
7. Vendor’s manufacturing facility shall be available for viewing prior to award of
contract, in order to demonstrate in-house capabilities to perform all aspects of
the scope of work specified.
8. Vendor shall provide references for similar projects and be prepared to arrange
site visits.
9. All work surfaces for casework and equipment consoles shall be constructed to
within tolerances of 1/64”. All equipment consoles shall be constructed to within
tolerances of 0.020” for metal components and 1/32” for casework components
of equipment consoles.
B. Submittals
Vendor shall supply the following to obtain project level approval:
1. Copy of ISO 9001 Certification.
2. Copy of Green Guard Certification.
3. Detailed CAD drawings of console and equipment layouts for coordination of
site measurements, architectural, mechanical, and electrical project elements for
each console type.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
4
Date Published: March 2015
Version Control: EC-PS-ID v2
4.
5.
6.
7.
Detailed CAD drawings of each console type with its specific equipment per
application.
Animated rendering of consoles and room upon request.
Pre-production review, to include a drawing submittal and component listing
complete with samples of selected finish materials.
Samples of the following material components, which demonstrate
workmanship:
a.
Worksurface sample with ergonomic nosing.
b.
Cross section sample of the main structural steel frame member.
C. Approved Suppliers
The console shall be manufactured by Evans Consoles, or pre-approved equal.
Evans Consoles Corporation
1616-27th Ave NE
Calgary, Alberta T2E 8W4
4.0
CONSOLE MATERIAL SPECIFICATIONS
A. General
1. The consoles shall be of modular design, facilitating future equipment retrofits
and full reconfigurations without requiring any major modification to the
structure or exterior elements.
2. The console structure, sub structure and frame shall form a freestanding unit
independent of the exterior cladding.
3. The consoles shall be manufactured to industry recognized ISO 9001 quality
standards.
B. Ergonomics and Operator Safety
1. Consoles shall be designed in accordance with the ergonomic standards of ISO,
ANSI, BIFMA and CSA.
2. The work surface platform shall have smooth edges and transitions, thus
avoiding sharp corners or potential “rib catchers” for operator safety.
3. Sharp edges at the console base and in CPU cavities are not acceptable and
represent potential “knee-banger” operator safety issues. All transitions and
curves shall have a minimum 5-inch radius.
4. All human-machine interface-related equipment (display, keyboard, mouse, etc.)
shall travel with the upper console section. Any variety or combination of
input/output devices shall be accommodated by the system. Reach and viewing
distances/relationships shall not be compromised when console is in standing
position.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
5
Date Published: March 2015
Version Control: EC-PS-ID v2
C. Console Frame Structure
1. Extrusions (Aluminum Alloy)
a. The patented portal style frame and rear stringer extrusions shall be
constructed of thick wall, custom extruded aluminum as outlined in the table
below. This adds to the rigidity and ruggedness of the design and allows for
unparalleled flexibility in the ability to customize or reconfigure consoles.
Component
Alloy
Temper
Upper Beam
6005A-T5
Lower Beam, Frame and 6063-T54
Door Columns
& Yield
Strength
Ultimate
Strength
31 KSI / 100 38 KSI
PSi
30 KSI
30 KSI
2. Col
umns, Inserts and Corner Modules (Sheet Metal)
a. All sheet metal used for structural components shall be cold rolled steel
(CRS). These components ensure square, rigid connection of the front
portal to the rear frame assembly, module-to-module connections at corner
positions, and attachment of front, rear and end panels.
b. Sheet metal parts to be produced on CNC machines to ensure precision:
1. Side inserts and Rear Frame columns – 12 gauge C.R.S.
2. Rear Door Columns – 14 gauge C.R.S.
3. Corner Modules – 14 and 16 gauge C.R.S.
3. Seismic (with optional seismic kiti)
a. The base console shall have passed the Bellcore Zone IV test (7.0 – 8.3
Richter scale). For Bellcore certification, specific console loaded with
comparable end-user equipment must be tested.
D. Internal Components
1. Monitor shelf shall be:
a. Single high shelf - 300 lbs. (135 Kg) load, 16 gauge C.R.S. – 100-lb (45-Kg)
capacity. Powder coated black.
b. Double High shelf – 100 lbs. (45 Kg) load, 16 gauge C.R.S. – 100-lb (45-Kg)
capacity. Powder coated black.
2. Processor shelf shall be:
a. Fixed Shelf – 200 lbs. (90 Kg) load, 14 gauge CRS, Powder coated black.
b. Door mounted shelf – 40 lbs. (18 Kg) load, 14 gauge CRS, Powder coated
black.
c. Slide out shelf – 100 lbs. (45 Kg) load, 14 gauge CRS, Powder coated black.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
6
Date Published: March 2015
Version Control: EC-PS-ID v2
3. Maximum equipment shall be:
a. Door Mounted shelf – 17” (432 mm) x 8 ½” (216 mm) x 18” (457 mm).
b. Fixed and slide out shelves – FD – 18” (457mm) x 14” (356mm0 x 21 ½”
(546mm).
c. Fixed and slide out shelves RD – 7 ¾” (197mm) x 17 ½” (445mm) x 17”
(432mm).
E. Worksurfaces
1. The rigid console worksurface shall be designed to provide a smooth, level work
area, while complying with accepted human factor criteria. All ergonomic
standards shall been taken into consideration, including view/reach distances,
keyboard height, and knee well space. The adjustable worksurface option
provides further flexibility allowing for customized height positioning
(continuously variably within a 5” range). Worksurfaces shall have the following
properties:
a. Materials
1. 1 in (25.5mm) Particle Board.
b. Finish
1. High-pressure plastic laminate surface veneer.
c. Static Load
1. 50 lb./ linear ft.
2. Maximum 250 lb. / 115 kg per surface on Adjustable Worksurfaces.
d. Surface to Floor Distance
1. Fixed: 28 ½ in (27 ½ in clearance).
2. Adjustable: 26-31 in (Customizable).
e. Adjustable Worksurface Drive
1. Manual: Hideaway Hand-crank.
2. Power: Electricalmotor and worm drive.
3. Maximum load on adjustable worksurface is 1130N (250lbs or 113.4kg).
4. Height ranges from 26” to 31” (660.4mm to 787.4mm).
f. Sit-Stand worksurfaces shall use Linek DL2 (electro-mechanical) columns.
1. Full console sit to stand height adjustment must be available. Console
must use two columns for greater reliability and stability unless required
by loading. The top section of the console raises both the upper viewable
equipment and the worksurface together using an electric actuator. Owing
to the use of an electric drive system, no physical demands shall be placed
on the end-user when using the Sit/Stand function.
2. The lift system shall operate virtually silent and compensate for
differential loads from side to side, preventing racking or damage to the
structure.
3. The console work surface shall use electro-mechanical columns with a
minimum 2500N (562lb or 255kg) load.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
7
Date Published: March 2015
Version Control: EC-PS-ID v2
4. The maximum load on the worksurface is 5000N (1124lbs or 510 kg) with
two or more columns.
5. The maximum load on the worksurface is 2400 N ( 540 lbs or 246 kg)
with two columns .
6. Monitor Surface Speed is 10 mm/s (0.6 in/s Previously 15 mm/s
7. Input platform columns Speed is 23 mm/s
8. Height ranges from 28” to 46.5” (736.6 mm to1181.1 mm).
F. Panels
1. End Panels
a. 1 in (25.5 mm) particleboard with finish surface.
2. Lower / Intermediate Panels
a. 11/16 in (17.5 mm) particleboard with finish surface.
3. Top-back Panels
a. 11/16 in (17.5 mm) particleboard with 11/16 in KerfKore radius with finish
surface.
G.
Surface Finish Options
1. P. LAM (High-Pressure Plastic Laminate)
a. Panels shall be finished with a quality high-pressure plastic laminate surface.
While industry standards imply that a lower grade of P.LAM may be used on
vertical (non-load bearing) surfaces, the console shall employ the highest
quality, Horizontal Grade laminate on all panels and worksurfaces.
2. Wood Veneer
a. Veneer panels shall be professionally finished and highly customized
according to specific requirements. Manufacturer shall manufacture veneer
panels in house to accommodate a variety of wood finishes.
3. Steel Cladding
a. Optional Steel panel kit can be added.
H. Task Light
1. Console lighting shall have the following properties:
a. Superior light quality: The Color Rendition Index (CRI) of 80 is higher than
that of the quartz halogen. The higher the CRI the more accurately it portrays
colors.
b. Mechanical dimmer (with shutter): a mechanical dimmer effectively controls
the amount of light without changing the color temperature or reducing bulb
life (electronic dimmers reduce bulb life up to 80%). The mechanical dimmer
will dim lighting form 20% to 60%.
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
8
Date Published: March 2015
Version Control: EC-PS-ID v2
c. Continuous linear light source: compared to point light sources, a continuous
linear light source allows for better light dispersion onto the work surface and
eliminates hot spots.
d. T5 fluorescent bulbs.
e. High electrical efficiency.
f. Slim and elegant profile, which matches, or is similar to, the console design.
g. UL & C-UL approved.
I. Worksurface Actuator
1. The electronic actuators used to drive the adjustable worksurfaces shall be state of
the art units, incorporating a current limiting system to prevent accidental
overloads.
2. Conform the following:
a. 24V DC or 12 V DC permanent magnet motor.
b. 8 Amps (24 V) / 5 Amps (12V) at full load.
c. Maximum thrust: 300 lbs. at a speed of 1.26 in / sec.
J. Power Bar
1. If power bars are requested, but not specified otherwise, powerbars must be
industrial grade power bars, (no suppression) for North America or International
powerbars for overseas with the following specifications:
a. 120 V and 220 V available, as well as customer specified custom
requirements.
b. 5 Outlets.
c. CE, VDE Certified.
K. Ventilation Fan (Optional)ii
1. Fans must be available for mounting on the doors or wire tray. The individual
situation may dictate a change in the ventilation requirements. A console with a
greater than normal amount of electronic equipment, or with equipment emitting a
greater than normal level of heat, may require extra fan units.
2. The fan shall meet the following specifications:
a. 3.62 in x 3.62 in x 1.0 in Brushless DC Fan.
b. The transformer with plug adapts to 12 Volts DC (Voltage range: 7 – 15V).
c. 1.3 Watts Brushless fan provides extremely quiet operation.
d. Manufactured with an incorporated finger guard.
e. UL, CSA, VDE Listed / Approved.
f. Output is 36 CFM @ 0.0in, 27 dBA.
L. Rounded Polyurethane Worksurface Nosing
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
9
Date Published: March 2015
Version Control: EC-PS-ID v2
1.
2.
3.
4.
5.
Polyurethane foam secured over an aluminum extrusion carrier.
Comfortable and ergonomically sound.
Allows for curved sections with a 14 in radius.
An edge slope and radius spreads the weight over a larger surface. Enhancing
end user comfort.
Polyurethane nosing will be mechanically replaceable in the event of damage or
wear (not glued in place)
M. Options Available
1. The following options shall be available to increase the functionality of the
console solution:
 Custom Millwork & Options
 Slatwall
 Johnson Environmental Controls
 Large screen monitor enclosure
 Seismic kit
 Turrets
 Casters
 Corrosive environment upgrades (including stainless steel hardware)
 Anchoring
 Corian worksurfaces
 Gaskets
 Positive pressure consoles for high dust environments
 Trouble lights
 Custom widths
 Radial frames
 Height of each (desktop, single high, double high etc) can be adjusted
 Articulating monitor arm
 Upper-level articulating monitor arm.
 Letter tray (painted metal)
 Binder box (painted metal)
 Paper flow manager
 Pen / pencil cup
 Office tray for compartments for small office tools
 Split worksurfaces for adjustability
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
10
Date Published: March 2015
Version Control: EC-PS-ID v2

















5.0
Fabric walls
Privacy panels
Monitor arrays
Layout transitions
Overhead mobile pods
Monitor arms off end panels
Gus Keyboard Trays
Stretched depth with custom pistons
Plexi-glass inlays
Stretched height modules
Rear lower internal binder storage
Wire-mould raceway
Recessed Duplex End panels
Cable Grommets
Phone shelves
Articulating phone arms
2 and 4 point rackmount kits
SHIPPING AND INSTALLATION
A. Packing
1. The console supplier shall be responsible for packing the components in a manner
that will ensure undamaged and complete arrival at the destination. Conform to
the following:
a. All panel, worksurface, and accessory elements shall be detached from the
structural modules and packed in strapped corrugated containers with
protective material.
b. All components shall be blanket-wrapped and shipped in LTL or dedicated
air-ride transports.
c. All delivery instructions will be confirmed before the packaging of materials.
B. Shipping
1. The console supplier shall make the following modes of shipping available:
a. Consoles shall be stripped down and shipped with a minimal amount of
packaging.
b. Consoles shall not move with general freight carriers. The product shall be
shipped with professional furniture movers on air ride trailers. The product
shall be hand loaded into the trailers, and each piece shall be protected with
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
11
Date Published: May 2010
Version Control: EC-PS-ID–v1.10
padded blankets. Minimal amount of stacking shall be permitted, so the use
of logistic trailers is highly recommended.
2. The freight quotation shall cover the services of Multiple staged delivery activity
as mandated by the project management schedule. This activity covers the
movement of the delivery vehicle from the console supplier to the destination site
and the direct off-loading into the facility. Any additional services including, but
not restricted to, after-hours delivery, unionized labor requirements, load transfers
to shuttle equipment, excessive distance carry or specialized off-loading
equipment shall be invoiced accordingly.
C. Installation
1. The console supplier shall provide the following forms of installation support and
service:
a. Installation labor and site supervision
b. Site supervision of client-provided installation labor
c. Maintenance manuals.
2. Modules shall be able to be assembled using standard tools without any site
cutting or drilling. The console supplier shall provide a set of hand tools. Each
module shall be rigid and self-supporting to permit individual removal, relocation
or modification of adjacent modules.
D. Schedule
1. Upon award of a contract or issuance of a purchase order, the console supplier
shall prepare and submit a project schedule with specified dates, based upon the
following key milestones:
a. Detailed requirements analysis.
b. Final design submittal.
c. Pre-production approval submittal.
d. Fabrication period.
e. Factory acceptance/packing & shipping.
f. Delivery date.
g. Installation.
6.0
WARRANTY
Unless otherwise stated in the Quotation, Evans warrants that all consoles and technical
furniture manufactured by it will be free from defects in materials and workmanship from
the date of transfer of title as follows:
1 LIFETIME WARRANTY on all fixed structural frame components;
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
12
Date Published: May 2010
Version Control: EC-PS-ID–v1.10
2
3
4
5
LIFETIME WARRANTY (parts) on all static exterior panels and work surface
components parts; (5 years on labor);
LIFETIME WARRANTY (parts) on all adjustable, sliding or hinged
mechanisms or parts (5 years on labor);
OEM warranty on all buyouts, including (5) years on all E-Line Products (unless
specifically defined by product line); and,
Five years on electrical actuated lift columns
*For full warranty details reference the Evans Warranty Statement
7.0
TERMS AND CONDITIONS
A. Standard Terms shall be 50% Deposit with the Order, 40% Net 30 Upon Console
Shipment, 10% Net 30 Upon Installation
i
Only available with desktop and single-high configurations.
The individual situation may dictate a change in the ventillation requirements. A console with a greater than normal amount of electronic
equipment, or with equipment emitting a greater than normal levels of heat, may require extra fan units. Please contact Evans Solutions Team
for more information about your specific requirements.
ii
Evans Consoles Corporation 1616 27th Ave NE Calgary AB, Canada
Evans Consoles Incorporated, 1115, 381 Park Ave South New York, NY 10016
www.evansonline.com
13