DIAGNOSTIC INSIGHTS Sponsored by an educational grant from IDEXX Laboratories Choosing an in-house hematology analyzer Fred Metzger, DVM, DABVP Metzger Animal Hospital State College, Pa. Impedance counters are based on the beam, the pattern of light scattered by the A complete blood count (CBC) is essential to Coulter principle. The Coulter method of sizindividual cells records the cell size, nuclear the assessment of the general health status ing and counting particles is based on the characteristics, and cytoplasmic contents, of a patient and the evaluation of potential change in resistance as the particles pass providing a true optical 5-part leukocyte underlying diseases. A CBC is an integral part through a small aperture between two elecdifferential. Some analyzers provide an of the diagnostic workup of every sick patient, trodes. Because cells are classified on size absolute reticulocyte count for the dog and every preanesthetic examination, every senior alone, not all WBCs can be differentiated cat, which is the gold standard in classifying or wellness profile, and every reevaluation of from one another. Nucleated red blood anemias. This technology may be slightly patients with previous erythrocyte, leukocyte, cells and clumped platelets are the same more expensive than the other available or platelet abnormalities. relative size as leukocytes and may be mismethodologies and was previously limited The advantage of getting immediate results classified as WBCs and large platelets, or only to reference laboratories. and providing better patient care is motivatsmall clumps of platelets may be counted The features of in-house hematology ing more practices to invest in automated as erythrocytes. analyzers vary greatly. Practitioners should hematology analyzers. Since the advent of the Another significant issue with impedanceweigh the pros and cons of each instrument Coulter counter 50 years ago, hematology before deciding which one is most approprianalyzers have improved substantially, provid- based systems is that they require the use of reagent fluids for normal instrument cycling ate for the practice (Table 1). Regardless of ing more accurate cell counts with automated and involve a considerable amount of mainte- instrumentation, veterinarians should inter2-, 3-, or 5-part differential counts and requirnance and cleaning, which may increase the ing considerably less technician time. pret all analyzer results with a peripheral price per test. Impedance analyzers are moder- blood film evaluation, which provides In-house hematology analyzers can be ately priced and provide fast results, but they grouped according to technology into quantiinvaluable information about the cellular cannot provide a true 5-part leukocyte differtative buffy coat (QBC) analysis, impedance morphologic changes that automated instruential or reticulocyte count. counters, and laser flow cytometers. Because ments cannot provide. Because hematologic Laser flow cytometry is the most recent hematology instrumentation can represent a samples are particularly vulnerable to and accurate automated cell analyzer technolsignificant investment for a veterinary pracchanges over time, in-house analyzers offer ogy and the method used in most reference tice, a strong knowledge of the underlying the benefits of immediate and reliable inforlaboratories to determine the leukocyte differtechnology and capabilities of the various mation for screening, diagnosing, and moniential count. As cells pass through a laser analyzers is necessary to make the most toring your patients’ health. informed choice. The QBC method classifies Table 1: Comparing three types of in-house hematology analyzers cells based on density and staining of cellular compoLaser Flow Cytometer Impedance or Focused-Flow Impedance Quantitative Buffy Coat Profile nents. Under high-speed cen5-part differential 3-part differential WBC Differential 2-part differential trifugation, blood separates Neutrophils Granulocytes Lymphocytes/Monocytes (combined) into plasma, the buffy coat Lymphocytes Lymphocytes Granulocytes Monocytes Monocytes (3-part differential for canine and bovine (which contains white blood Eosinophils (Some systems estimate samples with a significant number cells [WBCs] and platelets), Basophils eosinophils and basophils.) of eosinophils) and the red blood cells. The Yes No Absolute Reticulocyte Count No, but reticulocyte % is reported. QBC analyzers are easy-to-use 10 minutes 1 to 3 minutes Sample Run Time 7 minutes and very economical, require little to no maintenance, and are efficient at screening normal hematology samples. The major disadvantages are the inability to provide a full 5part differential because lymphocytes are grouped with monocytes, and, in felines and equines, the inability to differentiate eosinophils, which are reported in the granulocyte count. Nucleated RBC Interference with WBC Count No Yes No Large Platelet Interference with Cell Counts No Yes No Moderate Minimal Minimal Run calibration rod daily. Daily background counts Weekly and/or monthly cleanings (Some systems require 3-month, 6-month, and yearly maintenance.) Clean air filter weekly. Yes (Review cell morphology, provide 5-part differential, validate data) Yes (Review cell morphology, provide 5-part differential, validate data) Yes (Review cell morphology, validate data) Technician Time for System Run Required Maintenance Need for Peripheral Blood Film Evaluation © 2006 IDEXX Laboratories
© Copyright 2025 Paperzz