Improving Energy Efficiency through Burner Retrofit Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Unternehmen Weishaupt Overview Typical Boiler Plant Cost Factors Biggest Efficiency Losses in a boiler system Radiation Losses Incomplete Combustion Blowdown Stack Losses Boiler Design Excess Air W i h Weishaupt t burner b as a solution l ti tto E Excess Ai Air Conclusion Burner installation/retrofit examples Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 2 Unternehmen Weishaupt Typical Boiler Plant Cost Factors 3% 2% 1% 1% 10% 9% Labor Fuel 74% Source: GE Infrastructure Water& Process Technologies Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 3 Unternehmen Weishaupt Biggest Efficiency Losses in a boiler system 1% 76% 20% 100% 3% Example of Losses in a Boiler System Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 4 Unternehmen Weishaupt Efficiency Losses in a boiler system Radiation Losses Insulate where possible Incomplete Combustion Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 5 Unternehmen Weishaupt Complete Combustion with Weishaupt Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 6 Unternehmen Weishaupt Efficiency Losses in a boiler system Blowdown Even with the best pretreatment programs feedwater contains impurities. Water must periodically be “blown down” to take care of these impurities Improper blowdown causes increased fuel consumption, the need for more chemicals and heat loss Blowdown heat can be recovered and reused in the boiler operations. Stack Losses Biggest Factor in the equation (up to 20%) 35-40 °F of stack temperature equals approx. 1% in energy loss Stack temperature is dependent on the steam pressure (i.e. 100 PSI = 338 °F) Older Boilers before 1970 were not built with stack temp. In mind. Here an economizer can help help. NOW – let‘s look at Excess Air! Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 7 Unternehmen Weishaupt Combustion with Excess Air Some burners use more than 100% excess air Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 8 Unternehmen Weishaupt Excess Air vs vs. Oxygen Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 9 Unternehmen Weishaupt Quality Engineered Burner Heads mean REPEATABILITY Low NOx Ultra Low NOx Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 10 Unternehmen Weishaupt Moving Diffuser for Increased Turndown and Low Excess Air Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 11 Unternehmen Weishaupt Linkage Less Control Components Servo drives WFM Main Module 100 & 200 AZL Programming Module Flame Detector Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 12 Unternehmen Weishaupt Conclusion Usually the Conclusion would be to service the burner as well as possible and reduce excess air to the minimum of what the burner can use and still combust environmentally friendly. With Weishaupt a new option is available: Burner Retrofit Let‘s look at some examples in the Chicago area: Hinsdale Hospital AON Center Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 13 Unternehmen Weishaupt Adventist Hinsdale Hospital Hospital, Hinsdale Hinsdale,IL IL The 436-bed hospital is recognized as a leader in a wide range of medical fields, where university-level care and medical breakthroughs are achieved each day. Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 14 Hinsdale Hospital Savings 13% 63000 USD Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Healthcare Facilities Energy conservation contributes directly to operating income. Research of the Environmental Protection Agency (EPA) shows that facilities that implement energy conservation measures outperform their competitors co pet to s be as much uc as 10% 0% in net et ope operating at g income. co e The EPA estimates that for Hospitals: , in energy gy savings g is Æ$100,000 ÆEqual to the margin earned from $2,000,000 in new revenues. Regardless g the age, g high g performing g hospitals use as little as one-fourth of the energy used by like facilities which are at the bottom of the performance scale. EPA Study, Boosting Your Bottom Line through Improved Energy Use, June 2005 Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Unternehmen Weishaupt AON Center Savings 16% 85000 USD Copyright © by Max Weishaupt GmbH, D-88475 Schwendi Seite 17
© Copyright 2026 Paperzz