NEW 5635 Remote Annunciator and SK Devices Now Compatible with the Updated
5600 Hybrid Conventional-Addressable FACP version 2.00
Now Shipping!
Silent Knight is pleased to announce the introduction of the 5635R (red) and 5635W (white) costeffective Remote Annunciators, compatible with the updated 5600 Version 2.00 hybrid conventiionaladdressable fire alarm control panels.
5635
The 5635 is a compact, backlit, LCD remote annunciator, available in either red or white. It provides
system status for AC Power, Alarm, Trouble, Supervisory and Alarm Silenced conditions. Up to two
5635's can be connected to the 5600 via the SBUS
5635R
5600 Version 2.00 NEW features:
- Communicates with the new remote annunciator 5635R and 5635W
- Now compatible with the SK Devices or cost-effective HFS Devices (see chart below for specific device
compatiblity)
The 5600 is a 25 point single loop addressable fire alarm control panel with a conventional user interface. Aimed at
the two to five zone conventional fire control projects, the 5600 provides addressable technology at a conventional
application price. Powerful features such as drift compensation and on-board sensitivity testing are delivered in the
FACP from Silent Knight. The 5600 also includes a built-in digital dual-line communicator/dialer and easy to use
interface, creating a revolutionary value.
5635W
5600 Version 2.00 compatible SLC devices
SK Device
HFS
Device
Description
SK-PHOTO
HFS-P
Addressable photoelectric smoke detector
SK-PHOTO-T HFS-PT
Addressable photoelectric smoke detector with thermal
SK-DUCT
HFS-D
Addressable photoelectric duct smoke detector
SK-HEAT
HFS-T
Addressable fixed temperature thermal detector
SK-MINIMON HFS-MM
Addressable mini monitor module
SK-RELAY
Addressable relay module
HFS-MR
SK-PULL-DA
Addressable dual action pull station
SK-PULL-SA
Addressable single action pull station
No custom programming tools required
With code wheel addressable detectors/modules and JumpStartâ„¢ feature, the panel can be Life
Safety operational without a single programming tool. Custom programming, such as dialer
options, are programmed through the panel's innovative built-in browser. No custom downloading
software or updates are required.
http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM]
Knight Line August 2011
Addressable technology at a conventional price
Using standard wire, no shielded or twisted pair required, the addressable detectors give you the
powerful features and benefits of addressable technology in a conventionally priced package. Drift
compensation greatly reduces nuisance alarms, maintenance alert reduces repeat service calls,
and point status meets calibrated smoke test requirements for NFPA 72
Silent Knight Simplicity
Addressable panel complexity has been taken out of this innovative addressable control and
replaced with Silent Knight simplicity. Simple installation, simple programming, and simple user
interface all combine for a quick installation and reliable fire protection for which Silent Knight is
known.
5600 Version 2.00
Frequently Asked Question
Question: When connecting to the 5600 via the Ethernet port I receive an error "Cannot find page", "Unable to open page", etc. What is the
problem and how can I establish this connection?
Answer: The 5600 fire alarm control panel is configured to search for a DHCP server once it is connected to the computer through an
standard Ethernet cable.
Your computer must be selected to DHCP
Your Ethernet cable should be straight through connection
The 5600 browser application is compatible with Firefox, IE 7, and IE 8.
When direct connected, it will normally take about 40 seconds to display the IP address on the 5600 seven segment displays. The panel displays
"IP" while the IP address is being determined during this 40 second search period.. A computer with a Windows operating system may take up
to an additional 1 minute to fallback to the APIPA (Automatic Private IP Addressing) which enables the computer to communicate to the panel.
When the 5600 seven segment displays begin flashing its IP address you will be able to enter the IP address in your computers browser and
begin custom programming.
If the connection fails, check the IP configuration of the computer. The first two values of the computer IP address should match the first two
values of the 5600 panel IP address. If the computer is selected for DHCP and these values do not match, either you computer does not
support the APIPA function the 5600 needs or there is a problem with the cable or computer port. You can select the computer for a static
address and match the first two values of the 5600 IP address. If you still are unable to establish a connection try replacing the Ethernet cable.
http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM]
Knight Line August 2011
Product Application
Take Advantage of Addressable Benefits at a Conventional Price
Are you currently using 2-5 zone conventional fire alarm control panels? Consider using the 5600 fire alarm control panel on you next convenience
store, strip mall, small office building or sprinkler supervisory installation. Take full advantage of the addressable benefits the 5600 has to offer. Drift
compensation significantly reduces nuisance alarms, point status eliminates manual sensitivity calibration testing, and maintenance alert reduces
repeat service calls. Don't forget the 5600 includes the value of a built-in dialer that the majority of conventional panels you need to purchase
separately.
Contact our application engineering team for more information: [email protected] 800-446-6444 ext. 4140 [email protected]
800-446-6444 ext. 4141
Silent Knight Training Schedule
Visit www.silentknight.com/htmfiles/training.html for entire Silent Knight training schedule, class type descriptions, training tutorials, Just in Time
Learning video clips, and online courses.
Date
Location
Class Type
Cost
October 4, 2011
McAllen, TX
Fire Drill
FREE
October 5-6, 2011
McAllen, TX
Tech Ed
$200.00
October 4, 2011
Raleigh, NC
Fire Drill
FREE
October 5-6, 2011
Raleigh, NC
Tech Ed
$200.00
October 11, 2011
Miami, FL
Fire Drill
FREE
October 12-13, 2011
Miami, FL
Tech Ed
$200.00
October 25, 2011
Elmsford, NY
Fire Drill
FREE
http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM]
Knight Line August 2011
October 26-27, 2011
Elmsford, NY
Tech Ed
$200.00
November 1, 2011
Kansas City, KS
Fire Drill
FREE
November 2-3, 2011
Kansas City, KS
Tech Ed
$200.00
November 1, 2011
Baltimore, MD
Fire Drill
FREE
November 2-3, 2011
Baltimore, MD
Tech Ed
$200.00
November 29, 2011
Orlando, FL
Fire Drill
FREE
November 30 - December 1, 2011
Orlando, FL
Tech Ed
$200.00
November 29, 2011
Pittsburgh, PA
Fire Drill
FREE
November 30 - December 1, 2011
Pittsburgh, PA
Tech Ed
$200.00
December 13, 2011
Houston, TX
Fire Drill
FREE
December 14-15, 2011
Houston, TX
Tech Ed
$200.00
December 13, 2011
Salt Lake City, UT
Fire Drill
FREE
December 14-15, 2011
Salt Lake City, UT
Tech Ed
$200.00
Simple. Smart. Reliable.
www.silentknight.com
This email was sent to: [email protected]
This email was sent by: Silent Knight
12 Clintonville Road Northford, CT 06472
We respect your right to privacy - view our policy
Manage Subscriptions | Update Profile | One-Click Unsubscribe
http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM]