Knight Line August 2011 To view this email as a web page, go here. The Knight Line is a monthly newsletter published to share Silent Knight technical and marketing information with our customers. What's New? E-Newsletter Content What's New? FAQ Product Application Silent Knight Training Schedule NEW 5635 Remote Annunciator and SK Devices Now Compatible with the Updated 5600 Hybrid Conventional-Addressable FACP version 2.00 Now Shipping! Silent Knight is pleased to announce the introduction of the 5635R (red) and 5635W (white) costeffective Remote Annunciators, compatible with the updated 5600 Version 2.00 hybrid conventiionaladdressable fire alarm control panels. 5635 The 5635 is a compact, backlit, LCD remote annunciator, available in either red or white. It provides system status for AC Power, Alarm, Trouble, Supervisory and Alarm Silenced conditions. Up to two 5635's can be connected to the 5600 via the SBUS 5635R 5600 Version 2.00 NEW features: - Communicates with the new remote annunciator 5635R and 5635W - Now compatible with the SK Devices or cost-effective HFS Devices (see chart below for specific device compatiblity) The 5600 is a 25 point single loop addressable fire alarm control panel with a conventional user interface. Aimed at the two to five zone conventional fire control projects, the 5600 provides addressable technology at a conventional application price. Powerful features such as drift compensation and on-board sensitivity testing are delivered in the FACP from Silent Knight. The 5600 also includes a built-in digital dual-line communicator/dialer and easy to use interface, creating a revolutionary value. 5635W 5600 Version 2.00 compatible SLC devices SK Device HFS Device Description SK-PHOTO HFS-P Addressable photoelectric smoke detector SK-PHOTO-T HFS-PT Addressable photoelectric smoke detector with thermal SK-DUCT HFS-D Addressable photoelectric duct smoke detector SK-HEAT HFS-T Addressable fixed temperature thermal detector SK-MINIMON HFS-MM Addressable mini monitor module SK-RELAY Addressable relay module HFS-MR SK-PULL-DA Addressable dual action pull station SK-PULL-SA Addressable single action pull station No custom programming tools required With code wheel addressable detectors/modules and JumpStartâ„¢ feature, the panel can be Life Safety operational without a single programming tool. Custom programming, such as dialer options, are programmed through the panel's innovative built-in browser. No custom downloading software or updates are required. http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM] Knight Line August 2011 Addressable technology at a conventional price Using standard wire, no shielded or twisted pair required, the addressable detectors give you the powerful features and benefits of addressable technology in a conventionally priced package. Drift compensation greatly reduces nuisance alarms, maintenance alert reduces repeat service calls, and point status meets calibrated smoke test requirements for NFPA 72 Silent Knight Simplicity Addressable panel complexity has been taken out of this innovative addressable control and replaced with Silent Knight simplicity. Simple installation, simple programming, and simple user interface all combine for a quick installation and reliable fire protection for which Silent Knight is known. 5600 Version 2.00 Frequently Asked Question Question: When connecting to the 5600 via the Ethernet port I receive an error "Cannot find page", "Unable to open page", etc. What is the problem and how can I establish this connection? Answer: The 5600 fire alarm control panel is configured to search for a DHCP server once it is connected to the computer through an standard Ethernet cable. Your computer must be selected to DHCP Your Ethernet cable should be straight through connection The 5600 browser application is compatible with Firefox, IE 7, and IE 8. When direct connected, it will normally take about 40 seconds to display the IP address on the 5600 seven segment displays. The panel displays "IP" while the IP address is being determined during this 40 second search period.. A computer with a Windows operating system may take up to an additional 1 minute to fallback to the APIPA (Automatic Private IP Addressing) which enables the computer to communicate to the panel. When the 5600 seven segment displays begin flashing its IP address you will be able to enter the IP address in your computers browser and begin custom programming. If the connection fails, check the IP configuration of the computer. The first two values of the computer IP address should match the first two values of the 5600 panel IP address. If the computer is selected for DHCP and these values do not match, either you computer does not support the APIPA function the 5600 needs or there is a problem with the cable or computer port. You can select the computer for a static address and match the first two values of the 5600 IP address. If you still are unable to establish a connection try replacing the Ethernet cable. http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM] Knight Line August 2011 Product Application Take Advantage of Addressable Benefits at a Conventional Price Are you currently using 2-5 zone conventional fire alarm control panels? Consider using the 5600 fire alarm control panel on you next convenience store, strip mall, small office building or sprinkler supervisory installation. Take full advantage of the addressable benefits the 5600 has to offer. Drift compensation significantly reduces nuisance alarms, point status eliminates manual sensitivity calibration testing, and maintenance alert reduces repeat service calls. Don't forget the 5600 includes the value of a built-in dialer that the majority of conventional panels you need to purchase separately. Contact our application engineering team for more information: [email protected] 800-446-6444 ext. 4140 [email protected] 800-446-6444 ext. 4141 Silent Knight Training Schedule Visit www.silentknight.com/htmfiles/training.html for entire Silent Knight training schedule, class type descriptions, training tutorials, Just in Time Learning video clips, and online courses. Date Location Class Type Cost October 4, 2011 McAllen, TX Fire Drill FREE October 5-6, 2011 McAllen, TX Tech Ed $200.00 October 4, 2011 Raleigh, NC Fire Drill FREE October 5-6, 2011 Raleigh, NC Tech Ed $200.00 October 11, 2011 Miami, FL Fire Drill FREE October 12-13, 2011 Miami, FL Tech Ed $200.00 October 25, 2011 Elmsford, NY Fire Drill FREE http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM] Knight Line August 2011 October 26-27, 2011 Elmsford, NY Tech Ed $200.00 November 1, 2011 Kansas City, KS Fire Drill FREE November 2-3, 2011 Kansas City, KS Tech Ed $200.00 November 1, 2011 Baltimore, MD Fire Drill FREE November 2-3, 2011 Baltimore, MD Tech Ed $200.00 November 29, 2011 Orlando, FL Fire Drill FREE November 30 - December 1, 2011 Orlando, FL Tech Ed $200.00 November 29, 2011 Pittsburgh, PA Fire Drill FREE November 30 - December 1, 2011 Pittsburgh, PA Tech Ed $200.00 December 13, 2011 Houston, TX Fire Drill FREE December 14-15, 2011 Houston, TX Tech Ed $200.00 December 13, 2011 Salt Lake City, UT Fire Drill FREE December 14-15, 2011 Salt Lake City, UT Tech Ed $200.00 Simple. Smart. Reliable. www.silentknight.com This email was sent to: [email protected] This email was sent by: Silent Knight 12 Clintonville Road Northford, CT 06472 We respect your right to privacy - view our policy Manage Subscriptions | Update Profile | One-Click Unsubscribe http://view.exacttarget.com/...7462&l=fe6415767667047c7d11&s=fe23117374620d74761577&jb=ffcf14&ju=fe34177275670d78751772[10/3/2011 4:59:31 PM]
© Copyright 2026 Paperzz