LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 A. Masi Contents 1. 2. Minor upgrades and interventions performed Possible actions for TS2 A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed Main software changes: • MDC (Motor Drive Control) : bug of 5 um error on the profiles execution during change of direction successfully fixed publication of the system uptime (to easily detect UPS power cuts) added • PRS (Position Readout & Survey) : publication of the system uptime (to easily detect UPS power cuts) added • FESA Class: publication of the PRS and MDC uptime added •Temperatures UNICOS Software: TDI temperatures put away from interlock logic MP tests relaunched in all the tunnel A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed Actions performed : • TCTPH.4R2.B2 Resolver Left Upstream saturation issue: resolver acquisition custom Europa card, NI cable and motor exchanged bad connection on the pin 12 of the tunnel resolver cable found and fixed • TCLA.A7R7.B1 LVDT Gap Upstream issue (sigma around 40 um): NI cable and DAQ card replaced • TCLIA_4L8_RU temperature probe Rigth Upstream problem: False contact on the collimator cable found and fixed A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed Actions performed : • SLAC COLLIMATOR successfully installed in BA5: Outer switches hardware connected to the BIC FESA device instantiated (still FESA 2.0) Axes need to be calibrated remotely A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed LHC Collimators temperatures tests: Movement cycles of all the collimators in order to detect perturbation on the temperature readings One direct correlation found: TCDIV 29012 Left Upstream- Potential local cable false contact. Sensor need to be bypassed A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed LHC Collimators temperatures tests: 120 sensors affected by strange short spikes to 52 °C in the time window of repeated motion cycles. The short spike is anyway filtered in the current PLC reading logic. Problem under investigation A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed LHC Collimators temperatures tests: Strange short spikes to 52 °C experienced in the time window of repeated motion cycles A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed LHC Collimators temperatures tests: Strange short spikes to 52 °C experienced in the time window of repeated motion cycles A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 1–Minor upgrades and interventions performed LHC Collimators temperatures tests: Strange short spikes to 52 °C experienced in the time window of repeated motion cycles A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1 2–Possible actions for TS2 Possible actions for TS2: • Possible change of the temperatures interlock logic generate an interlock only if both sensors of the same jaw overcome the threshold gradient in time: ignore the sensor if dT/dt > XX deg/s difference jaw sides: ignore if |Delta(upstreamdownstream)|>Delta_T max max temperature un-physical: ignore if T > Tmax • Update of the PXI 10 MHz synchronization distribution A Masi, LHC Collimators Low Level Control: Report on EN/STI interventions in TS1
© Copyright 2026 Paperzz