Centrifugal Utility Fans Model SFD, SFB, SWD and SWB Direct and Belt Drive New Model SWD with ® January 2014 Models SFD, SFB, SWD and SWB Utility Fans Contents Standard Construction Features .................... 4-5 Engineering Data ............................................... 16 Vari-Green Options ........................................ 6-7 Fan Identification/Model Selection.................... 18 Severe Duty Options ...................................... 8-9 SFD Dimensions and Performance ............ 17-18 Temperature Options ......................................... 10 SWD Dimensions and Performance........... 17-19 Options and Accessories .............................10-12 SFB Dimensions and Performance ............ 20-29 Typical Installations ........................................... 13 SWB Dimensions and Performance........... 30-65 Discharge Position/Dimensional Data ..........14-15 Typical Specifications ................................. 66-68 Greenheck Fan Corporation certifies that the model SFD, SFB, SWD and SWB, fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. The certified ratings for Model SFD, SFB and SWB are shown on pages 15-61. Greenheck Fan Corporation certifies that the model SWB Series 300 AF, fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The certified ratings for Model SWB Series 300 AF are shown on pages 49-61. SFD, SFB, SWD and SWB Series 100, 200 and 300 models are listed for electrical (UL/cUL 705) File no. E40001 SWB Series 200 and 300 models are listed for grease removal (UL/cUL 762) File no. MH11745 SWB Series 200 and 300 models are listed for Emergency Smoke Control Systems File No. MH17511 High Wind Certification Seismic Certification Miami-DADE Notice of Acceptance (NOA) 09-0303.31 for high wind and hurricane zones OSHPD - Office of Statewide Health Planning and Development - OSP-0113-10 Florida Product Approval Number - FL12680 IBC 2006 and 2009 - International Building Code Enjoy Greenheck’s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. • Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15- or 25 day production cycles, depending upon their complexity. • Greenheck’s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. • Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. • Our 3D service allows you to download at no charge lightweight, easy-to-use AutoDesk™ Revit™ 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com 2 Models SFD, SFB, SWD and SWB Utility Fans Model Comparison Models SFD and SFB Greenheck models SFD and SFB forward-curved utility fans have been designed for supply, exhaust and return air applications requiring low to medium air volumes and pressures. You will receive the following benefits with these fans: • SFD fans are available in four sizes (6, 7.5, 9 and 10) with different rpm motors. Capacities range from 150 to 2,600 cfm (255 to 4,600 m³/hr) with static pressures to 2.5 in. wg (623 Pa). Model SWD and SWB Greenheck’s backward-inclined utility fans have many advantages; higher operating efficiencies, nonoverloading horsepower curves and higher pressure capabilities. You will also receive the following benefits with these fans: • SWD fans are available in seven sizes (7 through 18) with capacities from 100 to 5,500 cfm (170 to 9,352 m³/hr) and static pressures to 2.5 in. wg (623 Pa). Model SWD is offered exclusively with Vari-Green electronically commutated motors for energy efficiency and ease of control. • SWB Series 100 in ten sizes (106 through 124) with capacities from Maximum Volume (cfm) Maximum Static Pressure (in. wg) Relative Cost Mixed Flow Centrifugal Direct Belt Propeller/Axial High Temp (above 200°F ) High Wind (150 mph) Smoke Control (UL) 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Grease (UL 762) 9 9 9 9 Spark Resistant 9 9 9 9 Recirculate 9 9 9 9 Reversible Wall Hanging Base/Floor Roof Curb 9 9 9 9 Impeller Type Performance Contaminated Air SWB 9 9 9 9 Drive Type Application General/Clean Air SWD 9 9 9 9 Supply SFB Indoor SFD Outdoor Model Airflow Exhaust Mounting Ceiling Mounted Location 2,600 2.5 $ 25,200 3.5 $$ 5,500 2.5 $$ 54,000 5 $$ • SFB fans are available in ten sizes (9 through 30) with capacities ranging from 360 to 25,250 cfm (610 to 42,900 m³/hr) and static pressures to 3.5 in. wg (872 Pa). • Greenheck utility fans are designed, engineered and tested prior to shipment to provide years of smooth, vibration-free operation with minimal maintenance. • The fan may be mounted indoors or outdoors. • All fan sizes are tested in our AMCA accredited laboratory to ensure complete and accurate performance ratings. All models are licensed to bear the AMCA Air Performance seal. Performance as cataloged is assured. 70 to 11,000 cfm (120 to 18,700 m³/hr) and static pressures to 3.0 in. wg (747 Pa). • SWB Series 200 in twelve sizes (206 through 224) with capacities from 70 to 13,700 cfm (120 to 23,300 m³/hr) and static pressures to 5.0 in. wg (1,250 Pa). • SWB Series 300 in seven sizes (327 through 349) with capacities from 4,600 to 54,000 cfm (7,700 to 91,700 m³/hr) and static pressures to 5.0 in. wg (1,250 Pa). • Greenheck utility fans are designed, engineered and tested prior to shipment to provide years of smooth, vibration-free operation with minimal maintenance. • Fans may be mounted indoors or outdoors. • Fans are tested in our AMCA accredited laboratory to ensure complete and accurate performance ratings. All models are licensed to bear the AMCA Air Performance seal. SWB 300 Series AF fans are licensed to bear the AMCA Sound and Air Performance seal. Performance as cataloged is assured. 3 Standard Construction Features Standard Construction Features All structural steel parts are phosphate treated and coated with Greenheck’s Permatector™ for a long lasting finish. Galvanized construction remains unpainted. Backward Inclined or Airfoil Finish Backward Inclined 2 Backward Inclined SWB Series 100 and 200 through size 210 and all sizes of SWD have backward-inclined non-overloading centrifugal wheels constructed of aluminum. Series 200, sizes 212 and larger and Series 300 wheels are constructed of steel or aluminum. Backward-inclined wheels are made of a heavy-gauge material with single-thickness blades securely riveted or welded to a heavy-gauge backplate and wheel cone. SWB Series 300 fans are available with aluminum airfoil wheels. Each wheel is statically and dynamically balanced to precise tolerances. Backward Inclined SFD and SFB fans have forward-curved centrifugal wheels constructed of die formed steel with blades securely riveted to a steel backplate and rim. Each wheel is statically and dynamically balanced to precise tolerances. Forward Curved Wheel SWB 100 200 300 Forward Curved 1 SFD SFB SWD — — — — — — Painted Steel Painted Steel or Aluminum Housings are available in clockwise or counterclockwise rotation and are field rotatable to the eight standard discharge positions. Side panels are bonded to the fan housing with an airtight lock seam. Fully welded housings are also available on SFB, SWD, and SWB Series 200 and 300 models. Galvanized SFD and SWB Series 100 housings are constructed of galvanized steel. SFB and SWB Series 200 and 300 housings are constructed of steel and coated with Permatector™ as standard. SWB Series 200 may also be constructed with aluminum housings and housing supports. SWD housings can be galvanized, painted steel, or aluminum. Galvanized, Painted Steel, or Aluminum Housing Painted Steel 3 Galvanized • See housing and drive frame information for specific material and coating. Base rails have prepunched mounting holes which allow for easy installation. 9 9 9 9 9 9 6 Drive Frame SFB and SWB Series 100 and 200 drive frames are constructed of rugged, welded and coated steel members (Series 300 drive frames are constructed of reinforced heavy-gauge galvanized steel) supporting the shaft and bearings to provide rigid reinforcement for the housing. SFB and SWB drive frames are arrangement 10. SFD drive frames are constructed of galvanized steel, bolted and available in arrangement 4. SWD drive frames are constructed of galvanized or painted steel, bolted and available in arrangement 4. 7 Fasteners Corrosion-resistant fasteners are used to secure unit base and blower scroll assembly. 8 Motor Heavy-duty ball bearing motors are carefully matched to the fan load. Open drip proof, totally enclosed, and explosion resistant enclosures are available for SFD, SFB, and SWB fans. Vari-Green motors are included with all SWD fans, and are optional for model SFD. Galvanized Mounting Holes Painted Steel 5 Painted Steel 9 9 9 9 9 9 Galvanized or Painted Steel Housing supports are constructed of heavy-gauge steel with formed flanges for extra strength. Painted Steel Housing Supports Galvanized 4 9 9 9 9 9 9 9 9 9 9 9 9 Vari-Green motor enclosures may be open drip proof or totally enclosed. 9 Inlet Cone Streamlined inlet cone design provides for low turbulence air intake, reducing intake losses and sound levels. 4 9 9 9 9 9 9 Standard Construction Features Belt Drive Only Features SFB SWB 100 200 300 10 Motor Plate Pivoting motor plate with adjusting screws make belt tensioning a quick and easy operation. 9 9 9 9 11 Drive Assembly Machined, cast iron pulleys are factory set to the required RPM and are adjustable for final system balancing for applications with 10 hp or less motors. Sized for a minimum of 150% of driven horsepower. 9 9 9 9 12 Fan Shaft Precision turned, ground and polished solid steel shafts are sized so the first critical speed is at least 25% over the maximum operating speed. Stainless steel shafts are available on SWB Series 200 and 300 fans. 9 9 9 9 13 Bearings Heavy-duty, self-aligning pillow block ball bearings are selected for a minimum L10 life in excess of 100,000 hours (L50 average life of 500,000 hours) at maximum cataloged operating conditions. 9 9 9 9 3 SFB and SWB 200 2 1 7 3 13 SWD 7 8 12 13 6 4 3 1 7 8 11 5 4 8 10 6 6 SFD 5 5 3 3 7 SWB 100 2 7 SWB 300 2 13 13 11 12 12 11 6 8 4 4 8 10 6 10 5 5 5 Vari-Green® Options Vari-Green® Motor - SWD and SFD Greenheck’s electronically commutated (EC) Vari-Green (VG) motor combines motor technology, controllability and energy-efficiency into one single low maintenance unit and is the industry’s first fully controllable motor. When combined with Greenheck’s SWD/SFD fans, most of the CFM and static pressure ranges of a belt drive can be attained with the benefits of a direct drive. Motor Information HP 1/6 RPM 1725 Volts 115 115 1/4 1725 115/230 115 1/2 1725 115/230 115 3/4 1725 115/230 115 1 1725 115/230 1 1725 115/208-230 2 1725 208-230 Extended RPM Motors 1/2 2500 115 3/4 2200 115 HZ 50/60 Phase Single Enclosure TENV Single Single FLA 3.4 3.7 3.3/1.8 6.7 6.8/3.5 10.1 9.0/4.9 12.4 11.4/6.3 12.0/6.0 12.0 50/60 Single 50/60 Single 50/60 Single 50/60 Single 50/60 50/60 50/60 50/60 Single Single 6.5 11.3 ODP ODP ODP ODP ODP ODP Vari-Green Advantages • Initial cost is similar to a belt drive • Lower operating cost • No maintenance, no belts, pulleys or bearings • Easy RPM adjustment Features 1. Dial on Motor Control - A potentiometer (dial on motor control) is mounted on the motor for easy speed adjustment for system balance. Simply turn the dial; there are no belts and pulleys to adjust. 2. Control Wire Inputs - the motor accepts a 0-10 VDC signal from Building Automation Systems, Vari-Green Controls or other controls to adjust motor speed. 3. Consolidated Motor with Dial and 0-10 VDC signal - Refer to greenheck.com, Vari-Green Motor IOM for specific information. TEFC TEFC Vari-Green Motor Benefits Operates on AC power that’s converted to DC— providing a more efficient motor operation as compared to an AC operation. • The motor can attain up to 85% efficiency and reduce energy consumption. • Watt savings of 20-70% depending on RPM. Note: As motor speed is turned down, efficiency stays high ® Constant Volume Life Cycle Analysis Three Year Cost Comparison as compared to an AC motor that decreases dramatically. • Operates cooler than a standard AC motor at lower RPMs. A cooler motor has longer motor life and reduces energy consumption. • 80% usable RPM turndown vs. 30% on AC single phase direct drive. • SWD and SFD fans with Vari-Green motors can provide most of the CFM and static pressure ranges of a comparable belt drive. • Maintenance costs are reduced as there are no belts or bearings to replace and no pulleys to adjust. • Direct drive fans are often preferred where maintenance access is difficult. • Provides a solution for demand controlled ventilation applications. 6 Analysis is based on operating costs for a period of three years where the fans operate continuously at 1725 rpm, 24/7, with an energy rate of $0.10/ kWh. Maintenance on the SQ-120 is estimated at $65/yr. $2000 1800 1600 1400 1200 1000 800 600 400 200 $0 Belt Drive VariGreen® Initial Cost Maintenance cost over three years Operating cost over three years Note: Example is based on a relative cost. Use and installation variables may produce different results. Vari-Green® Options Demand Controlled Ventilation for Multistory Buildings install for applications that include: venting dryers, bathrooms, residential type kitchen space or industrial process exhaust. Applications requiring constant pressure or variable volume can utilize SWD and SFD fans with Vari-Green motors and Vari-Green controls. Demand controlled Variable Volume Operating Cost Analysis ventilation systems reduce Variable Volume vs. Constant Volume the amount of energy used $2,000 by decreasing the speed 1,750 of the fan when demand 1,500 is low. This in turn lessens 1,250 the amount of conditioned 1,000 air exhausted and further 750 reduces total operating 500 costs associated with air conditioning and heating 250 in multistoried buildings $0 Constant Variable such as: hotels, multifamily Volume Volume complexes, institutional Heating Cost facilities, and high rise Cooling Cost commercial buildings. Fan Operating Cost Contact [email protected] for more information. Example of potential savings based on a northeast city in the USA using Vari-Green components for variable volume. Vari-Green® Controls Transformer - Provides 24V power from the existing line voltage at the fan to the Vari-Green motor and controls. Dual voltage primary (120/240V) transformer provided with the fan. % of Operation Hypothetical (Hotel Bathroom) Variable Volume - Load Shape 100 80$$$$$$$$$$$$$$$$$$$$$$$$ 60$$$$$$$$$$$$$$$$$$$$$$$$ 40$$$$$$$$$$$$$$$$$$$$$$$$ 20$$$$$$$$$$$$$$$$$$$$$$$$ 0%$$$$$$$$$$$$$$$$$$$$$$$$ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time of Day Series 1 Demand controlled ventilation offers significant energy savings by exhausting only the necessary amount of air throughout the day. % of Operation The Vari-Green constant pressure control is preprogrammed and easy-to- Daily Operating Comparison: Variable Volume and Constant Volume Constant Volume - Load Shape 100 80 60 40 20 0% 1 2 3 4 Series 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time of Day Note: A standard VFD compatible motor can also function within a variable volume system. • Institutional facilities - Schools, prisons, multistory office buildings; bathrooms. Constant Pressure Control - Outdoor Control Vari-Green motor via static pressure on the inlet side of the fan. Includes one duct probe and transducer for use in: Remote Dial - Allows for remote, manual airflow adjustments. Wall plate with dial may be mounted in a standard 2x4 inch electrical junction box. • Multifamily structures - Apartments, condos, hotels; residential kitchen, dryer facilities and bathrooms. Two-Speed Control with Integral Transformer Control allows motor RPM to be set at two independent speeds (high or low). Meets minimum airflow requirements with the ability to bump up to high speed in an emergency or meet maximum airflow requirements, or reset to low for energy conservation. Speeds are selectable via either a dry contact input which utilizes an external switching device to toggle between speeds, or an AC digital input which allows an AC voltage signal to be used to change speeds. Air Quality – VOC - Control a Vari-Green motor via changes in volatile organic compounds (VOC’s). VOC’s are gasses that are emitted from humans, building materials, perfumes, foods, and furniture off-gassing. Range is 0-2000 CO2 ppm equivalent. Constant Pressure Control - Indoor Control Vari-Green motor via static (variable volume) or velocity (constant CFM) pressure on the inlet or outlet side of the fan. Optional, one or two, duct or room probes for use in: • Multifamily structures - Apartments, condos, hotels; dryers, residential kitchens and bathrooms. • Institutional facilities - Schools, prisons, multistory. • Institutional facilities – Schools, court house, hospitals; bathrooms, waiting rooms, cafeteria. • Commercial buildings – Office space, conference rooms, bathrooms, break room. Air Quality – Temperature and Humidity Control Vari-Green motor via changes in temperature, humidity, or both. Range is 15 to 130°F (-10° to 55°c) and 0 to 100% relative humidity. • Multifamily structures – Apartments, condos, hotels; bathrooms, utility rooms. • Commercial buildings – Office buildings; office space, conference rooms, utility rooms, bathrooms. 7 Applications High Wind and Hurricane High Wind and Hurricane SFD, SFB and SWB Series 100 and 200 Greenheck is leading the High Wind Standard for rooftop fans and ventilators. Forceful winds and wind-borne debris are the cause of most hurricane damage. Hurricane winds start at 75 mph and can exert a force of 75 pounds per square foot of pressure—or over 900 pounds on a fan and curb. Forceful winds are not the only problem, wind-borne debris can also cause detrimental effects to objects and structures. High winds and extreme forces are the cause of most storm damage. By analyzing calculations, computer simulations, actual testing, and other standards—Greenheck Atlantic, Gulf and Pacific history of major hurricane tracks. developed the High Wind Standard. Protocols designed to protect against wind-borne debris and severe wind loads: Structural Performance Load A static load that is 2 times the design load (180 pounds per square foot pressure) is applied both positive and negative to simulate wind force loads in each direction. Structural Performance per Dade County Protocol TAS-202 (ASTM E-330). Large Missile Impact Test Large Missile Impact Testing is required when objects are located 30 feet or less from the ground. The test is per Dade County Protocol TAS-201. The test unit is impacted three times with a piece of lumber (2 in. x 4 in. x 6 ft.) weighing approximately nine pounds and traveling at 34 mph. This simulates wind-borne debris striking the fan. Greenheck has gone the extra mile and worked with Miami-Dade County to design a High Velocity Miami-Dade County Hurricane Zone standard for rooftop fans. The SFD, SFB and SWB Series 100 and 200 models are certified and approved by the Miami-Dade Building Code Compliance office and Texas Department of Test Protocols Insurance for use in hurricane zones. Miami-Dade NOA Numbers The certifications can be viewed on the Miami-Dade County website under the NOA numbers listed below. Models SFD, SFB and SWB Series 100 and 200 are the first upblast aluminum/steel fans in the industry that have received a Miami-Dade NOA for high wind (150 mph) and hurricane zones. SFD, SFB and SWB Series 100 and 200: 09-0303.31 Texas Department of Insurance The certifications can be viewed on the Texas Department of Insurance Windstorm website under TDI number RV-71. Structural calculations performed by a state licensed Professional Engineer (P.E.) on models SFD, SFB State Licensed P.E. and SWB Series 100 and 200 include Finite Element Analysis (FEA) and a stamped P.E. report of the fans compliance to ASCE 7-05 Minimum Design Loads for Buildings and Other Structures Standard and the Calculations Florida Building Code. The ASCE 7-05 Standard meets the IBC, Florida and Miami-Dade County codes. Certified Independent Third-Party Testing Each of the Greenheck models have been subjected to extensive testing procedures. The SFD, SFB and SWB Series 100 and 200 have been certified by an independent third-party to the ASTM E-330 Static Pressure Difference Standard, Florida Building Code Test Protocols TAS-202 Static Pressure Difference and TAS-201 Large Missile Impact. All tests are video taped for documentation of test method and results. Computational Fluid Dynamics (CFD) All Greenheck high wind models have been analyzed using Computational Fluid Dynamics (CFD). CFD is computer software designed to simulate the flow of high speed winds over the surface of objects. The software records the force profile exerted on the fan so it can be utilized in Finite Element Analysis (FEA). Finite Element Analysis (FEA) Utilizing the results from CFD analysis Greenheck can accurately predict the stress, strain, and deflection resulting from high wind loads. Greenheck high wind units have been proven to withstand high winds through Finite Element Analysis utilizing CFD results. 8 Applications Seismic and Spark-Resistance Seismic - SFD, SFB and SWB Series 100 and 200 With changes in building codes and standards more equipment is being required to be seismically certified in areas of the country not commonly thought of as being in seismically active zones. The International Building Code (IBC) is designed to provide model code regulations that safeguard public health and safety in all U.S. communities. IBC 2009 and 2012 are the latest versions adopted on state or local levels. With this code, the standards are intended to improve the performance and design of non-structural systems subject to seismic events. The State of California, one of the most active seismic areas in the United States, has the Office of Statewide Health Planning and Development (OSHPD). OSHPD regulates the design Dev and an construction of healthcare facilities to ensure they are safe and capable of providing services to t the t public after a seismic event. OSHPD developed their own unique certification process to incorporate t the t IBC and ASCE testing standards to ensure equipment remains operable after a seismic event. e Protocols designed for seismic standards: Seismic Testing Criteria All Greenheck seismically certified models have been tested using the most severe seismic event that is found on the Spectral Response Map per IBC Figures 1613.5 (1-2). Because our testing is performed under the worst case scenario, using the highest mapped seismic load, highest level occupancy category, worst case site class, and highest code mandated importance factor, it allows Greenheck seismically certified fans to be used anywhere in the United States under any conditions. California OSHPD Test Protocols The California Office of Statewide Health Planning and Development (OSHPD) requires all certified models be shake table tested in accordance with ICC ES AC-156, in which the fans are physically subjected to the same or greater forces than they will see during a seismic event. Subjecting Greenheck model SFD, SFB and SWB Series 100 and 200 fans to this type of testing ensures the fans will operate without problems after a seismic event. OSHPD Certification No. 0113-10 The OSHPD certification numbers and supporting documents can be viewed on OSHPD’s website and ensures that the fan has been subjected to and passed rigorous testing standards. State Licensed P.E. Calculations When using the fans in applications which are not covered by California OSHPD standards Greenheck models SFD, SFB and SWB Series 100 and 200 have been certified by a third-party engineering firm to IBC 2009, 2012 and ASCE 7-05 standards. These engineers hold professional engineers (PE) licenses in all 50 states so no matter where your job is located you are backed by a PE signature for your state. Certified Independent Third-Party Testing All Greenheck Seismically Certified Fan models have gone through extensive testing procedures. Greenheck models SFD, SFB and SWB Series 100 and 200 have been certified to IBC 2009, 2012, ASCE 7-05 and California OSHPD standards through both engineering calculations and shake table testing of all models by independent third-party engineering firms. Spark-Resistant Construction The following AMCA Standards apply to fan applications that may involve the handling of potentially explosive or flammable particles, fumes or vapors. Models SFB, SWD and SWB are available with spark resistant construction options that meet the intent of these AMCA Standards. • AMCA Type A - All parts in contact with the airstream are constructed of nonferrous material (aluminum). Models SFB, SWD and SWB do not meet AMCA Type A spark resistant construction because the fan shaft is steel. • AMCA Type B - The fan wheel is constructed of nonferrous material (aluminum). A nonferrous (aluminum) rub ring surrounds the fan shaft where it passes through the fan housing. Available on models SWD and SWB Series 200 and 300. • AMCA Type C - The inlet cone is constructed of nonferrous material (aluminum). A nonferrous (aluminum) rub ring surrounds the fan shaft where it passes through the fan housing. The constructions listed minimize the potential of ferrous components making contact with each other that may produce sparks. However, they do not guarantee against the potential of producing sparks. The installer must electrically ground all fan and system components. 9 Applications Emergency Smoke Control Temperature Options Testing High temperature testing was conducted at Greenheck’s Research and Development facility with airstream temperatures in excess of 1000°F (538°C). Temperatures were monitored at the following critical locations throughout the tests: bearings, bearing compartment, motor, motor compartment, airstream and fan housing. Continuous Operating Temperatures Utility fans are suitable for applications with elevated temperature airstreams. Refer to the chart at the right for continuous operating temperature guidelines and optional accessories. High Temperature/Emergency Smoke Control The SWB Series 200 sizes 212 to 224 and Series 300 may be equipped for emergency smoke removal applications by specifying a high temperature option. The table below right indicates the construction features included in the high temperature options enabling exhaust of heat and smoke at 500°F (260°C) for a minimum of 4 hours or 1000°F (538°C) for a minimum of 15 minutes. Temperature ratings for both high temperature options were tested in accordance to UL smoke control systems. Options and Accessories Wiring Pigtail - Allows direct hookup to the power supply eliminating field wiring to the fan. Disconnect Switches A wide selection of NEMA rated switches are available for positive electrical shutoff and safety, including: dusttight, rainproof and corrosion-resistant. 10 SWB SWB SWB SWD Series Series Series SFD, SFB Continuous 100 200 300 Operating Temperatures Galvanized, and Painted Painted Aluminum Steel SFD SFB Construction Steel or Galvanized Steel Airstream Aluminum -20° to 200°F (-29° to 93°C) Standard 201° to 300°F 9 (94° to 149°C) Heat Slinger/ Shaft Seal 301° to 400°F 9 9 9 (149° to 204°C) Heat Slinger/ Shaft Seal 9 9 9 9 9 9 9 9 9 The maximum continuous operating temperature on the SWB is 400°F. For continuous operating temperatures between 401° and 1000°F use an Arrangement 1, 9 or 10, backward-inclined centrifugal fan model BISW. High Temperature SWB Features Series 200 & 300 Steel Construction Shaft Seal Heat Slinger High Temperature Option High Temperature Option with UL 9 9 9 9 9 9 9 9 Weatherhood UL Label (Power ventilators for smoke control systems) Testing for Emergency Smoke Temperature and Time Guidelines Time Code Class Tested Temperature (Hours) IRI 500°F (260°C) 4.00 SBCCI 1000°F (538°C) 0.25 BSI Class A 302°F (150°C) 5.00 BSI Class B 482°F (250°C) 2.00 BSI Class C 572°F (300°C) 0.50 BSI Class D 572°F (300°C) 1.00 BSI Class E 752°F (400°C) 2.00 MOTOR STARTERS The fundamental function of a motor starter is to protect the motor from damage that can occur from overheating. With a Greenheck motor starter, you will be provided with the best motor protection available. Specific model components may include; SmartStart™ technology, physical interface, overload protection, disconnect, magnetic contactor, NEMA-1, NEMA-3R, NEMA-4 and N NEMA-4X steel enclosures and pre-engineered easy system integration. For complete information on specific Greenheck Motor Starter models refer to greenheck.com, Products, Motor Starter page. Options and Accessories UL/cUL 762 - SWB Series 200 and 300 models are listed for grease removal (UL/cUL 762). The UL/cUL 762 option includes a weatherhood, threaded drain connection and access door. Indoor mounting requires the fan to have welded scroll construction. Weatherhood - Available to completely cover the motor and drive compartments; protecting the shaft, bearings, motor and drive components from moisture and other adverse weather conditions. Weatherhoods are vented to provide sufficient motor cooling, designed to meet OSHA guidelines and are easily removed for service access. Series 300 includes an access door. Drain Connection - Threaded drain connections can be provided to drain moisture from the bottom of the fan housing. Grease Trap (SWB Only) - Aluminum trap is designed to collect grease residue and avoid drainage onto roof surface. Disposable grease absorbents are available for easy maintenance. Access Doors - Access doors provide access for inspection and cleaning. Either bolted or hinged, quick opening access doors are available on all models except SFD. (Series 100—bolted option only) Welded Scroll Construction - Welded scroll construction is available on SWD and SWB Series 200 and 300. Aluminum Construction - Aluminum airstream option is available on SWD and SWB Series 200. Dampers - Gravity or motorized parallel blade backdraft dampers feature sturdy galvanized frames with prepunched mounting holes, aluminum blades with felt edges and balanced design for minimal resistance to airflow. Backdraft dampers are not suitable for downblast or bottom angular downblast discharge positions. The fan must be supplied with a flanged outlet to install a backdraft damper directly to the fan. Heavy-duty dampers are available for high pressure applications on fans with motors equal to or greater than 7½ horsepower. Extended Lube Lines - Lubrication lines with grease fittings are extended from shaft bearings to the base of the drive frame panel or weatherhood for easy bearing lubrication. Inlet box and Curb Cap - Used to minimize entry losses when a 90° turn is required at the fan inlet. Available on SWB Series 200. Inlet and Outlet Guards - Constructed of punched sheet metal or expanded metal mounted in a steel frame to provide protection for non-ducted installations. The guards can be easily removed for fan maintenance or inspection. Flanged Inlet and Outlet - Flanges are available for damper mounting or flanged duct connections. Inlet flanges have prepunched mounting holes. Outlet flanges are bolted on standard; welded for UL 762 applications Companion Flange - Connects to the inlet flange and then attaches to the ductwork. Recommended for slipfit duct connections. External Inlet Vane Dampers (SWB and SWD) - Available on model SWB fans, sizes 112–124 and 212–224 and SWD fans sizes 13-18. External vanes are mounted on the inlet flange. Inlet vane dampers feature zinc-plated steel blade axles, stainless steel washers and bearings. Vanes can be used for either manual or automatic operation, with controls furnished by others. Maximum operating temperature is 200°F (93°C). Coatings - A wide variety of coatings and colors are available for decorative to acidic applications on SFB, SWD and SWB Series 200 and 300. All Greenheck coatings can be found in the Performance Coatings for Commercial and Industrial Fans publication. Permatector™ is our standard coating. Typically used for applications that require corrosion resistance in indoor and outdoor environments. Hi-Pro Polyester is resistant to salt water, chemical fumes and moisture in more corrosive atmospheres. Typically used for applications requiring superior chemical resistance, excellent abrasion and outdoor UV protection. This coating exceeds protective qualities of Air Dried Heresite and Air Dry Phenolic. Baked Enamel Decorative Coatings are heat cured enamels applied as electrostatic powders. Customers can choose from 16 standard decorative colors or color match any color. Heat Slinger and/or Shaft Seal—all belt models and SWD - Heat slinger is an aluminum cooling disc mounted on the fan shaft between the inboard bearing and the fan housing. The disc dissipates heat conducted along the fan shaft. The shaft seal with an aluminum rub ring is available for applications where contaminated or high temperature air is being handled. 11 Mounting Options Vibration Isolators Base-mounted neoprene or spring isolators are available to lessen mechanical vibration and assure quiet operation. Free-standing, restrained and housed spring isolators are also available. Isolators are sized to match the weight of each fan. Free-Standing Open Spring Mounts Type 3, 1-inch Deflection Free-standing spring isolators are unhoused laterally stable steel springs. They provide a minimum horizontal stiffness of 0.8 times the rated vertical stiffness and provide an additional 50% overload capacity. These isolators are equipped with a topmounted adjusting bolt and an acoustical non-skid base. Springs are color coded to indicate load capacity. Rubber Mounts Type 2, ¼-inch and ½-inch Deflection Neoprene mountings consist of a steel top plate and base plate completely embedded in colored (oil-resistant) neoprene for easy identification of capacity. Neoprene mountings are furnished with a tapped hole in the center. This enables the equipment to be bolted securely to the rubber mount. Restrained Spring Mounts - Housed Spring Mounts Type 4B, 1-inch Deflection Housed spring isolators consist of steel springs assembled into a telescoping housing with a top-mounted adjusting bolt and an acoustical non-skid base. Housed spring isolators include resilient inserts to prevent metalto-metal contact and provide snubbing for side loads. Springs provide an additional 50% overload capacity and are color coded to indicate load capacity. Type 4A, 1-inch Deflection Restrained spring isolators consist of laterally stable, freestanding springs assembled into a steel housing. These assemblies are designed for vertical and horizontal motion restraint. Restrained spring isolators can be used for blocking during equipment installation and are provided with leveling bolts. Springs provide 50% overload capacity and are color coded or identified to indicate load capacity. Restrained spring mounts are recommended for equipment subject to wind loading or large torquing forces. Direct Mount - Type A Mounting Rails No base required. Isolators are attached directly to equipment. Direct isolation can be used if equipment is unitary and rigid without the use of additional support. If there is any doubt whether or not equipment can be supported directly on isolators, use rails, bases or consult the factory. with Isolators Isolation mounting rails are available with either rubber mount, free-standing open or restrained spring isolators. The isolators are mounted between aluminum rails that run the length of the fan base. Isolation rails provide easy installation on isolated systems, and are ideal for applications where there is a large overhung load. Mounting rails are available for fans up to size 36. Equipment Supports Models GESS and GESR equipment supports are available for roof mounting of utility fans up to size 36. Equipment supports are available in a number of lengths, widths, heights, and can also be built for a pitched roof. 12 Typical Installations General Clean Air or Fume Hood (Non–Grease) Flex The SFD, SFB, SWD and SWB are designed for applications ranging from clean air to contaminated air. Typical installations are shown below. Installations must include a means for inspecting, cleaning and servicing the exhaust fan. Flex 3 Wheel Diameters SWB Commercial Kitchen (Grease) Greenheck’s SWB Series 200 and 300 are designed to meet restaurant and foodservice applications. These fans are UL and cUL Listed for grease removal and have been tested under elevated temperature conditions. Due to high temperatures and grease-laden airstreams in commercial kitchen ventilation, system designers must be aware of governing codes and guidelines. The National Fire Protection Association (NFPA) is the primary source used by many local codes for commercial kitchen ventilation systems. Local code authorities should be consulted before proceeding with any kitchen ventilation project. selected. An outlet guard is strongly recommended when the fan discharge is accessible. When an outlet guard is not ordered with the fan, it must be provided by the installer. An upblast discharge is recommended. No dampers are to be used in the system. The fan discharge must be a minimum of 40 inches (1016 mm) above the roof line and the exhaust duct must be fully welded to a minimum distance of 18 inches (457 mm) above the roof surface. Weatherhood Inlet Box Installation must include a means for inspecting, cleaning and servicing the exhaust fan. Fans selected for grease removal must include a weatherhood, access door and 1-inch (25 mm) drain connection. For grease applications where the fan is mounted indoors, the welded scroll option must be Curb Cap Inlet box and curb cap are used when space is limited and a 90º turn is required less than 3 wheel diameters from the inlet. Upblast Discharge Optional Companion Flange **40 in. (1016 mm) Weatherhood 3 Wheel Diameters *18 in. (457 mm) ** Per NFPA 96 the fan discharge must be a minumum distance of 40 in. (1016 mm) above the roof surface. Duct From Kitchen Hood SWB Series 200 and 300 models are listed for grease removal (UL/ cUL 762). File no. MH11745 *Per NFPA 96 the duct must be all welded construction to a minumum distance of 18 in. (457 mm) above the roof surface. 13 SFD, SFB and SWD Discharge Positions and Dimensional Data CW BAU B CCW BAU C C SFD Dimensions B Unit Size D D A A H H CW UB I CCW UB G G I J J H H B 87⁄16 (27) (214) SFD-7.5 11⁄4 101⁄4 (32) (260) (173) SFD-9 15⁄16 1113⁄16 (33) (300) SFD-10 115⁄16 14 91⁄4 (49) (356) (235) SFB-9 E D A B B H H SFB-10 SFB-12 SFB-15 CCW TH CW TH F J SFB-18 F J I I H H SFB-20 SFB-22 SFB-25 CCW TAD CW TAD C C B B SFB-27 E E E 61⁄2 F 61⁄16 G 53⁄16 H 9 I 7 J 51⁄4 (141) (121) (165) (154) (132) (230) (178) (133) 613⁄16 513⁄16 73⁄4 71⁄4 61⁄4 92⁄3 81⁄2 63⁄4 (148) (197) (184) (159) (245) (216) (171) 73⁄4 61⁄2 815⁄16 85⁄16 73⁄16 107⁄9 91⁄2 71⁄2 (197) (165) (227) (211) (183) (274) (241) (191) 713⁄16 103⁄4 101⁄16 81⁄2 123⁄4 111⁄2 81⁄2 (198) (273) (256) (216) (324) (292) (216) F 815⁄16 G 75⁄8 H 134⁄5 I 101⁄4 J 8 (203) SFB-30 A 13⁄8 B 1211⁄16 C 81⁄4 D 7 E 91⁄2 (35) (322) (210) (178) (241) (227) (194) (350) (260) 17⁄16 141⁄2 95⁄16 713⁄16 103⁄4 101⁄16 89⁄16 151⁄6 111⁄2 91⁄4 (37) (368) (237) (198) (273) (256) (217) (385) (292) (235) 21⁄4 16 1011⁄16 91⁄16 123⁄8 119⁄16 97⁄8 151⁄6 131⁄4 93⁄4 (57) (406) (271) (230) (314) (294) (251) (385) (337) (248) 211⁄16 179⁄16 1113⁄16 915⁄16 1311⁄16 1211⁄16 107⁄8 163⁄4 145⁄8 105⁄8 (68) (446) (300) (252) (348) (322) (276) (426) (371) (270) 41⁄16 233⁄8 1513⁄16 131⁄4 185⁄16 171⁄8 145⁄8 221⁄3 195⁄8 133⁄4 (103) (594) (402) (337) (465) (435) (371) (567) (498) (349) 49⁄16 251⁄2 171⁄4 141⁄2 201⁄16 183⁄4 161⁄16 244⁄9 211⁄2 147⁄8 (116) (648) (438) (368) (510) (476) (408) (621) (546) (378) 55⁄16 28 191⁄16 16 221⁄8 203⁄4 1711⁄16 284⁄9 233⁄4 16 (135) (711) (484) (406) (562) (527) (449) (723) (603) (406) 61⁄16 3011⁄16 211⁄16 173⁄4 247⁄16 227⁄8 199⁄16 313⁄5 261⁄4 171⁄2 (154) (779) (535) (451) (621) (581) (497) (803) (667) (445) 5 34 22 19 261⁄2 241⁄2 207⁄8 33 283⁄4 187⁄8 (127) (864) (559) (483) (673) (622) (530) (838) (730) (479) 65⁄8 381⁄8 25 211⁄8 29 271⁄4 231⁄4 363⁄5 315⁄8 21 (168) (968) (635) (537) (737) (692) (591) (930) (803) (533) All dimensions in inches (millimeters). A H H CW DB G I SWD Dimensions CCW DB I G F Unit Size A B C D E F G H I J SWD-7 115⁄16 141⁄8 9¼ 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) SWD-8 15 1 ⁄16 14 ⁄8 1 9 ⁄4 13 7 ⁄16 10 ⁄4 10 ⁄8 5 8 ⁄8 15 ⁄8 11 ⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) SWD-10 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 151⁄8 111⁄2 85⁄8 (359) (198) (273) 101⁄8 (257) 85⁄8 (49) (219) (384) (292) (219) SWD-13 211⁄16 (68) 175⁄8 113⁄4 97⁄8 135⁄8 123⁄4 107⁄8 165⁄8 145⁄8 105⁄8 (448) (298) (251) (346) (324) (276) (422) (371) (270) SWD-15 31⁄8 191⁄2 131⁄16 11 151⁄8 141⁄8 121⁄8 181⁄2 161⁄4 115⁄8 (79) (495) (332) (279) (384) (359) (308) (470) (413) (295) SWD-16 31⁄2 211⁄4 145⁄15 12 169⁄16 151⁄2 131⁄4 203⁄8 173⁄4 121⁄2 (89) (540) (364) (305) (406) (394) (337) (518) (451) (318) SWD-18 41⁄16 233⁄8 1513⁄16 131⁄4 185⁄16 171⁄8 145⁄8 223⁄8 195⁄8 133⁄4 (103) (594) (402) (337) (465) (435) (371) (568) (498) (349) F H 1 3 1 1 1 H CW BAD D E CCW BAD E D C C H H A CW BH J F A F (235) All dimensions in inches (millimeters). CCW BH J G G H H Images are viewed from the drive side of fan. 14 D 43⁄4 SFB Dimensions CCW TAU D A C 59⁄16 All dimensions in inches (millimeters). Unit Size CW TAU E SFD-6 A 11⁄16 SWB Discharge Positions and Dimensional Data CW BAU B CCW BAU C C SWB Dimensions B D D A Size A B C D E F G H I J 106 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 107 15 1 ⁄16 14 ⁄8 9¼ 13 7 ⁄16 10 ⁄4 10 ⁄8 5 8 ⁄8 15 ⁄8 11 ⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 108 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 110 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 151⁄8 111⁄2 85⁄8 (359) (198) (273) 101⁄8 (257) 85⁄8 (49) (219) (384) (292) (219) 113 211⁄16 (68) 175⁄8 113⁄4 97⁄8 135⁄8 123⁄4 107⁄8 165⁄8 145⁄8 105⁄8 (448) (298) (251) (346) (324) (276) (422) (371) (270) 115 31⁄8 191⁄2 131⁄16 11 151⁄8 141⁄8 121⁄8 181⁄2 161⁄4 115⁄8 (79) (495) (332) (279) (384) (359) (308) (470) (413) (295) 116 1 3 ⁄2 21 ⁄4 5 14 ⁄15 12 9 16 ⁄16 15 ⁄2 13 ⁄4 20 ⁄8 17 ⁄4 121⁄2 (89) (540) (364) (305) (406) (394) (337) (518) (451) (318) 118 41⁄16 233⁄8 1513⁄16 131⁄4 185⁄16 171⁄8 145⁄8 223⁄8 195⁄8 133⁄4 (103) (594) (402) (337) (465) (435) (371) (568) (498) (349) 120 49⁄16 251⁄2 171⁄4 141⁄2 201⁄16 183⁄4 161⁄8 241⁄2 211⁄2 147⁄8 (116) (648) (438) (368) (510) (476) (410) (622) (546) (378) 124 13 5 ⁄16 15 30 ⁄16 1 21 ⁄16 17 ⁄4 7 24 ⁄16 22 ⁄8 9 19 ⁄16 31 ⁄2 26 ⁄4 173⁄4 (402) (786) (535) (451) (621) (581) (497) (800) (667) (451) 206 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 207 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (257) (219) (384) (292) (219) 208 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 210 115⁄16 141⁄8 91⁄4 713⁄16 103⁄4 101⁄8 85⁄8 151⁄8 111⁄2 85⁄8 (49) (359) (235) (198) (273) (257) (219) (384) (292) (219) 212 25⁄16 161⁄8 1011⁄16 9 123⁄8 115⁄8 915⁄16 151⁄8 131⁄4 93⁄4 (59) (410) (271) (229) (314) (295) (252) (384) (337) (248) 213 211⁄16 175⁄8 113⁄4 97⁄8 135⁄8 123⁄4 107⁄8 165⁄8 145⁄8 105⁄8 (68) (448) (298) (251) (346) (324) (276) (422) (371) (270) 215 1 3 ⁄8 19 ⁄2 1 13 ⁄16 11 15 ⁄8 14 ⁄8 12 ⁄8 18 ⁄2 16 ⁄4 115⁄8 (79) (495) (332) (279) (384) (359) (308) (470) (413) (295) 216 31⁄2 211⁄4 145⁄15 12 169⁄16 151⁄2 131⁄4 203⁄8 173⁄4 121⁄2 (89) (540) (364) (305) (406) (394) (337) (518) (451) (318) 218 41⁄16 233⁄8 1513⁄16 131⁄4 185⁄16 171⁄8 145⁄8 223⁄8 195⁄8 133⁄4 (103) (594) (402) (337) (465) (435) (371) (568) (498) (349) 220 49⁄16 251⁄2 171⁄4 141⁄2 201⁄16 183⁄4 161⁄8 241⁄2 211⁄2 147⁄8 (116) (648) (438) (368) (510) (476) (410) (622) (546) (378) 222 53⁄16 281⁄16 191⁄16 16 221⁄8 205⁄8 1711⁄16 283⁄4 233⁄4 161⁄4 (132) (713) (484) (406) (562) (524) (449) (730) (603) (413) 224 13 5 ⁄16 15 30 ⁄16 1 21 ⁄16 17 ⁄4 7 24 ⁄16 22 ⁄8 9 19 ⁄16 31 ⁄2 26 ⁄4 173⁄4 (402) (786) (535) (451) (621) (581) (497) (800) (667) (451) 327 51⁄8 35 231⁄4 195⁄8 267⁄8 25 211⁄2 33 283⁄4 211⁄4 (130) (889) (591) (498) (683) (635) (546) (838) (730) (540) 330 53⁄4 383⁄8 255⁄8 215⁄8 293⁄4 275⁄8 233⁄4 365⁄8 315⁄8 231⁄8 (146) (975) (651) (549) (756) (702) (603) (930) (803) (587) 333 63⁄4 421⁄8 283⁄8 2313⁄16 3213⁄16 309⁄16 261⁄16 40 34 9⁄16 (171) (1070) (721) (605) (833) (776) (662) (1016) (878) 336 713⁄16 465⁄16 315⁄16 265⁄16 363⁄16 333⁄4 2813⁄16 441⁄2 381⁄4 271⁄4 (198) (1176) (795) (668) (919) (857) (732) (1130) (972) (692) 340 87⁄8 503⁄4 347⁄16 2815⁄16 3915⁄16 373⁄16 3111⁄16 47 423⁄16 295⁄8 (225) (1289) (875) (735) (1014) (953) (805) (1194) (1072) (752) 344 101⁄8 5513⁄16 38 3115⁄16 441⁄16 411⁄16 35 52 465⁄8 325⁄16 (257) (1418) (965) (811) (1119) (1043) (889) (1321) (1184) (821) 349 11 ⁄8 61 ⁄16 41 ⁄16 35 ⁄8 48 ⁄16 45 ⁄8 38 ⁄16 57 51 ⁄16 353⁄16 (289) (1554) (1062) (892) (1230) (1146) (976) (1448) (1303) (894) A H H CW UB I CCW UB G G 1 1 1 (235) J H H CW TAU E CCW TAU D A E D A B B H 1 1 1 3 3 H CCW TH CW TH F J F J I I H H CCW TAD CW TAD C C B B E E A H H CW DB G I CCW DB I G F F H H CW BAD D E CCW BAD E D C 1 3 3 (273) 1 7 1 7 1 1 1 1 1 1 1 C H H A CW BH J H 3 I J G 1 F 25 (635) A CCW BH F J G H Images are viewed from the drive side of fan. 3 3 13 1 7 1 7 5 All dimensions in inches (millimeters). 15 Engineering Data Selection Effects of Installation on Performance The first consideration in any fan selection is the amount of air to be moved and the resistance to this air movement. Air volume requirements are established through specific codes or accepted industry standards. Once the air volume is known, system resistance can be determined by summing up the losses through the system components. Duct layout, duct size, coils, filters, dampers, and fan accessories all affect system resistance. ASHRAE Guide and Data Books and manufacturer’s data on individual system components are common sources of information available to the system designer. Fan ratings presented in the performance tables and curves of this catalog are in accordance with AMCA Standard 210 “Laboratory Methods of Testing Fans for Aerodynamic Performance Rating.” The AMCA test procedure utilizes an open inlet and a straight outlet duct to assure maximum static regain. In most applications, several fans may meet the required airflow and system resistance conditions. An optimum fan selection requires evaluation of alternative fan types and fan sizes, as they relate to initial cost, operating cost, available space, and allowable sound levels. The relative importance of these facts varies with each system. Any installation with inlet or discharge configurations that deviate from this standard may result in reduced fan performance. Restricted or unstable flow at the fan inlet can cause pre rotation of incoming air or uneven loading of the fan wheel yielding large system losses and increased sound levels. Free discharge or turbulent flow in the discharge ductwork will also result in system effect losses. The examples below show system layouts and inlet and discharge configurations which can affect fan performance. o 7 MAX. POOR GOOD FAIR Two types of wheels are available: 1. Backward-inclined or airfoil wheels turn at twice the speed of forward-curved fans and feature: • Higher operating efficiencies • A non-overloading horsepower curve which reaches a peak near the middle of the normal operation range • Stronger wheel design allowing for operation at higher static pressures 2. Forward-curved wheels typically have lower performance capabilities compared to the backward inclined and contain: FAIR POOR POOR One Impeller Dia. Turning Varies Should be at least 1/2 Impeller Dia. POOR FAIR GOOD POOR FAIR GOOD • Overloading type wheel (meaning that changes in performance can result in significant brake horsepower changes) • Forward-curved wheels have lower sound levels Comprehensive air performance data for these utility fans can be found in the fan tables and fan curves section, starting on page 18. Not Greater than o 60 Including Angle POOR 16 POOR FAIR SFD and SWD Direct Drive Model SWD (7 -10) M F H C J B G A N K L D E Model SFD Model SWD (13 - 18) N N F H M P P C J BB AA B G A N K K C C M M JJ K L D E E E E E LL H H H H G G F F D D DIMENSIONAL DATA Model SFD 6 7.5 9 10 SWD A B C D E F G H J K L M N 73⁄8 51⁄4 16 11 5/8 1411⁄16 83⁄16 11⁄16 91⁄16 6 11⁄4 7/8 111⁄4 53⁄16 (187) (133) (406) (279) (16) (373) (208) (27) (230) (152) (32) (22) (286) (132) 9 51⁄4 181⁄16 121⁄4 5/8 145⁄16 81⁄8 11⁄16 95⁄8 8 11⁄4 11⁄8 1311⁄16 63⁄8 (229) (133) (459) (311) (16) (364) (206) (27) (244) (203 (32) (29) (348) (162) 101⁄8 61⁄4 205⁄16 133⁄4 5/8 177⁄8 103⁄8 11⁄16 103⁄4 10 11⁄4 13⁄8 1513⁄16 77⁄16 (257) (159) (516) (349) (16) (454) (264) (27) (273) (254) (32) (35) (402) (189) 121⁄8 63⁄4 245⁄16 161⁄4 9/16 193⁄8 113⁄8 11⁄16 123⁄4 12 11⁄4 13⁄8 185⁄8 81⁄2 (308) (171) (618) (413) (14) (492) (289) (27) (324) (305) (32) (35) (473) (216) A B C D E F G H J K L M N 7 11 2 9 ⁄4 23 ⁄4 21 ⁄4 12 ⁄8 11 ⁄4 8 ⁄8 11 ⁄2 16 ⁄8 16 10 ⁄8 26 5⁄8 (279) (51) (248) (591) (552) (308) (286) (219) (292) (429) (406) (257) (676) 8 11 2 9 3⁄4 23 1⁄4 21 3⁄4 12 1⁄8 11 1⁄4 8 5⁄8 11 1⁄2 16 7⁄8 16 10 1⁄8 26 5⁄8 (279) (51) (248) (591) (552) (308) (286) (219) (292) (429) (406) (257) (676) 10 11 2 9 3⁄4 23 1⁄4 21 3⁄4 12 1⁄8 11 1⁄4 8 5⁄8 11 1⁄2 16 7⁄8 16 10 1⁄8 26 5⁄8 (279) (51) (248) (591) (552) (308) (286) (219) (292) (429) (406) (257) (676) 13 14 2 10 5⁄8 25 3⁄4 23 1⁄4 13 3⁄4 14 1⁄8 10 5⁄8 14 1⁄2 19 3⁄8 17 5⁄8 12 3⁄4 31 1⁄4 (356) (51) (270) (654) (591) (349) (359) (270) (369) (492) (448) (324) (794) 15 7⁄8 2 11 5⁄8 27 24 1⁄2 13 3⁄4 15 5⁄8 11 5⁄8 16 7⁄8 21 1⁄8 19 1⁄2 14 1⁄8 34 3⁄4 (403) (51) (295) (686) (622) (349) (397) (295) (429) (537) (495) (359) (883) 17 1⁄2 2 12 3⁄4 28 25 1⁄2 13 3⁄4 17 3⁄8 12 1⁄2 18 1⁄8 22 3⁄8 20 5⁄8 15 1⁄2 38 1⁄8 15 16 18 P 3 1 3 1 1 5 1 7 1 (445) (51) (324) (713) (648) (349) (441) (318) (461) (568) (524) (394) (969) 19 1⁄4 2 14 1⁄8 29 1⁄2 26 7⁄8 13 3⁄4 19 5⁄16 13 3⁄4 19 7⁄8 22 3⁄8 22 5⁄8 17 1⁄8 42 (489) (51) (359) (750) (683) (349) (491) (349) (505) (568) (575) (435) (1067) Max. Motor *Unit Frame Size Weight 30 56 (14) 56 145T 184T 40 (18) 75 (34) 113 (51) 69 — — (31) — — (31) — — (31) — — (44) — — 69 69 96 123 (56) 133 — — (60) 147 — — (67) All dimensions in inches (millimeters). Weight given in pounds (kilograms) 17 SFD - Direct Drive Model Number Code The model number code is designed to completely identify the fan. The correct code letters must be specified to designate the correct construction. The remainder of the model number is determined by the size and performance. SW B - 1 10 - AF - 3 - CW - Drive Fan Size Wheel Rotation Discharge Position B - Belt D - Direct 06 through 49 CW - Clockwise CCW - Counterclockwise UB TAU TH TAD DB BAD BH BAU Airfoil Wheel AF - (backward inclined wheel is standard) Wheel Type SW - Backward-Incline SF - Forward-Curved SFD dimensional drawings found on page 17. Series (SWB Only) Motor HP 100 - Galvanized Construction 200 - PermatectorTM Coated Steel Construction 300 - Galvanized and Permatector Coated Steel Construction 4 = 1/4 3 = 1/3 5 = 1/2 7 = 3/4 10 = 1 Motor RPM A = 1725 B = 1140 C = 860 ® Model SFD Direct Drive Motor HP 6B 6B 1/4 1725 1/6 1140 1/2 1725 VG 7.5 1/2 5A 10 1140 1/4 4A 9 1/6 4C 1/4 860 5B 1/2 1140 15A 1 1⁄2 1725 3C 1/3 860 7B 3/4 1140 30A 3 1725 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 15 20 30 50 75 = = = = = 11⁄2 2 3 5 71⁄2 100 150 200 300 400 = = = = = (Direct Drive only) D = 1550 E = 1050 G = 1300 VG = Vari-Green Fan RPM VG 6 TH 0.125 407 0.06 6.7 667 0.24 13.6 672 0.16 10.6 1062 0.59 20 839 0.18 9.2 1159 0.46 16.1 1806 1.64 31 1259 0.36 12.3 1713 0.86 19.4 2641 3.03 39 0.25 338 0.05 6.0 628 0.22 12.8 612 0.14 9.8 1028 0.56 18.6 748 0.15 7.8 1097 0.42 14.9 1765 1.59 29 1176 0.32 11.3 1653 0.82 18.5 2603 2.98 37 International (See CAPS for performance) K = 950 RPM J = 1475 RPM 0.375 232 0.03 4.7 585 0.20 12.3 549 0.13 9.4 988 0.53 16.8 645 0.12 7.0 1028 0.38 14.3 1725 1.54 28 1085 0.29 10.0 1592 0.77 17.6 2564 2.93 36 10 15 20 30 40 Model SFD 6 7.5 9 10 Static Pressure in Inches wg 0.5 0.75 1 1.25 541 0.17 11.7 467 0.10 8.6 949 0.50 15.8 487 0.09 6.6 957 0.34 13.6 1683 1.48 27 965 0.25 9.2 1528 0.72 17.0 2525 2.87 35 - Upblast Top Angular Upblast Top Horizontal Top Angular Downblast Downblast Backward Angular Downblast Backward Horizontal Backward Angular Upblast Wheel Diameter 6-5/16 (160) 7-2/3 (195) 9-1/8 (232) 10-3/4 (273) 1.5 2 Outlet Area 0.27 (0.03) 0.33 (0.03) 0.44 (0.04) 0.57 (0.05) 2.5 424 0.13 10.5 869 0.46 14.1 775 0.38 12.7 636 0.30 11.3 782 0.26 12.3 1595 1.36 25 1502 1.24 22 1407 1.13 21 1298 1.01 21 989 0.70 19.3 1378 0.64 15.7 2444 2.73 33 1163 0.52 13.9 2362 2.60 31 2275 2.44 30 2179 2.32 29 1942 2.01 27 1621 1.62 25 Performance certified is for installation Type B - Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 18 SWD - Vari-Green® Model SWD Wheel Diameter 7 11-3/8 (289) 8 11-3/8 (289) 10 11-3/8 (289) 13 13-1/2 (343) 15 14-3/4 (375) 16 17 (432) 18 19 (483) SWD dimensional drawings found on page 17. ® Model VG SWD Motor HP Fan RPM 1/4 1725 1/2 2500 1/4 1725 1/2 2500 1/4 1725 3/4 2200 1/4 1200 1/2 1550 3/4 1725 1/2 1150 3/4 1400 1 1725 3/4 900 1 1300 2 1725 3/4 850 1 950 2 1300 7 8 10 13 15 16 18 CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones CFM BHP Sones 0.25 535 0.16 12.4 802 0.49 23 713 0.14 10.5 1092 0.4 17.6 1283 0.26 14.7 1691 0.54 21 1382 0.18 9.3 1874 0.38 13.6 2115 0.52 16 1905 0.28 10.5 2412 0.51 14 3053 0.93 19.5 2054 0.25 8.8 3173 0.72 16.1 4324 1.65 26 2880 0.39 9.8 3302 0.54 11.9 4734 1.37 20 0.5 493 0.17 11.6 778 0.5 22 630 0.15 10.2 1039 0.42 17.4 1168 0.27 13.6 1602 0.55 19.7 1191 0.19 8.9 1739 0.39 13 1995 0.53 15.6 1671 0.29 9.9 2224 0.51 13.2 2896 0.95 19 1754 0.26 8 2983 0.75 15.3 4176 1.7 24 2510 0.4 9 2964 0.55 11 4487 1.39 19.7 0.75 437 0.17 10.8 750 0.51 22 534 0.15 9.5 984 0.43 17.1 1047 0.27 12.7 1512 0.55 18.9 964 0.19 8.6 1591 0.41 12.3 1870 0.55 14.9 1416 0.29 9.2 2027 0.52 12.5 2746 0.96 18.2 1394 0.26 7 2795 0.77 14.6 4033 1.73 24 2060 0.39 8.2 2631 0.56 10.1 4240 1.41 19.2 Static Pressure in Inches wg 1 1.25 1.5 1.75 380 308 0.17 0.17 11.1 10.6 721 689 648 603 0.51 0.52 0.52 0.52 21 21 20 19.8 405 0.15 9 926 864 796 716 0.45 0.45 0.46 0.45 16.6 16.2 15.5 14.8 921 785 0.27 0.27 12 11.5 1422 1324 1226 1123 0.56 0.56 0.56 0.56 18.2 17.4 16.6 15.5 Outlet Area 0.76 (0.07) 0.76 (0.07) 0.76 (0.07) 1.03 (0.10) 1.25 (0.12) 1.52 (0.14) 1.87 (0.17) 2 2.25 2.5 566 0.52 19.3 523 0.52 18.8 477 0.52 18.2 625 0.45 14.2 520 0.46 14 1018 0.55 14.6 882 0.55 14.9 1427 0.41 11.5 1731 0.56 14.2 1246 0.4 11 1581 0.57 13.6 1419 0.56 12.9 1230 0.54 12.5 1818 0.52 11.8 2592 0.97 17.5 1605 0.52 11.2 2422 0.98 16.8 2252 0.98 16 2080 0.97 15.2 1906 0.96 14.7 2573 0.79 13.8 3890 1.76 23 2328 0.79 13.1 3748 1.79 22 2078 0.78 12.6 3593 1.82 21 3422 1.85 21 3241 1.85 20 2162 0.54 9.6 3994 1.43 18.4 3765 1.44 17.6 3496 1.43 17 3157 1.4 16.6 3052 1.84 19.7 2863 1.83 18.9 Performance certified is for installation Type B - Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 19 SFB-9 - Belt Drive 167⁄8 151⁄2 65⁄8 (394) (168) 101⁄4 101⁄8 (260) (257) 2 (51) rve 8 (203) 24 (610) 10 197⁄8 133⁄4 (254) (505) left o 1 ⁄8 5 f th is s yste m cu (429) (41) se lec t to the (349) 115⁄16 131⁄2 (343) no t (287) 14 ⁄4 (362) 1 20 (508) Do Wheel Diameter = 91⁄2 (241) Shaft Diameter = 3/4 (19) Outlet Area = 0.454 ft2 (0.042 m2) ^Approximate Unit Weight = 120 lb. (54 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor Maximum BHP at given RPM = (RPM/1747)3 (Maximum KW at a given RPM = (RPM/1926)3) Maximum RPM = 2000 and Minimum RPM = 450 Tip Speed (ft/min.) = RPM x 2.49 (Tip Speed (m/s) = RPM x 0.0126) SFB-9 CFM Maximum Motor Frame Size = 145T OV 360 792 460 1013 560 1233 660 1453 760 1674 860 1894 960 2114 1060 2334 1260 2775 1360 2995 1460 3215 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 644 0.03 6.3 681 0.05 6.8 728 0.07 7.5 780 0.09 8.5 838 0.13 9.8 909 0.17 11.1 983 0.23 11.1 1059 0.30 12.0 1216 0.48 14.2 1297 0.59 15.7 1378 0.71 17.3 0.5 0.75 1 891 0.08 11.0 930 0.11 10.8 966 0.14 10.7 1013 0.18 10.6 1064 0.23 10.9 1118 0.28 11.5 1174 0.35 12.2 1318 0.54 14.3 1392 0.66 15.7 1468 0.79 17.2 1090 0.15 10.1 1129 0.18 10.3 1166 0.23 10.7 1207 0.28 11.1 1256 0.34 11.8 1306 0.42 12.6 1417 0.61 14.6 1482 0.72 16.1 1554 0.86 17.6 1225 0.19 10.3 1264 0.23 10.6 1303 0.28 11.0 1340 0.34 11.4 1378 0.40 12.1 1426 0.49 13.2 1528 0.69 15.7 1583 0.81 17.0 1639 0.94 18.3 Static Pressure in Inches wg 1.25 1.5 1.75 1382 0.28 11.0 1422 0.34 11.8 1461 0.40 12.6 1498 0.47 13.4 1534 0.55 14.3 1631 0.77 16.8 1682 0.89 18.1 1736 1.03 19.6 1528 0.39 13.2 1568 0.46 14.0 1608 0.54 14.9 1644 0.63 15.8 1728 0.84 18.1 1777 0.98 19.5 1827 1.13 21 1628 0.44 14.5 1667 0.52 15.4 1706 0.61 16.4 1745 0.71 17.5 1818 0.92 19.5 1866 1.06 21 1915 1.22 22 2 2.25 1758 0.58 17.0 1798 0.68 18.0 1837 0.78 19.1 1911 1.01 21 1949 1.14 22 1998 1.31 24 1845 0.64 18.6 1883 0.75 19.7 1923 0.86 21 1999 1.10 23 2.5 1965 0.82 21 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 20 SFB-10 - Belt Drive 193⁄8 (492) 91⁄4 111⁄2 151⁄2 81⁄2 (394) (216) 2 (51) mc urve (235) 113⁄4 (292) 265⁄8 yste (298) (279) 221⁄4 21⁄4 151⁄8 of t his s 11 (676) (565) 16 (406) lec t to the left (57) (384) se 12 (305) ot 203⁄8 (518) 22 (559) 167⁄8 (429) Do n Wheel Diameter = 105⁄8 (270) Shaft Diameter = 3/4 (19) Outlet Area = 0.705 ft2 (0.065 m2) ^Approximate Unit Weight = 130 lb. (59 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor Maximum BHP at given RPM = (RPM/1310)3 (Maximum KW at a given RPM = (RPM/1444)3) Maximum RPM = 1650 and Minimum RPM = 400 Tip Speed (ft/min.) = RPM x 2.78 (Tip Speed (m/s) = RPM x 0.0141) SFB-10 CFM Maximum Motor Frame Size = 145T OV 600 851 790 1121 980 1390 1170 1660 1360 1930 1550 2199 1740 2469 1930 2739 2120 3008 2310 3278 2500 3548 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 526 0.05 5.6 575 0.08 6.2 633 0.13 7.1 693 0.19 8.3 760 0.27 9.9 828 0.37 11.1 898 0.50 11.4 973 0.66 12.4 1050 0.85 13.8 1128 1.08 15.3 1207 1.36 17.1 0.5 0.75 1 730 0.12 9.1 777 0.18 10.3 828 0.25 10.7 887 0.35 10.7 946 0.46 11.0 1009 0.60 11.7 1077 0.77 12.7 1145 0.97 13.9 1214 1.21 15.2 1285 1.48 16.9 897 0.23 10.3 944 0.32 10.3 994 0.42 10.7 1049 0.54 11.3 1109 0.70 12.1 1169 0.87 13.0 1232 1.09 14.1 1299 1.34 15.6 1368 1.63 17.4 1013 0.30 10.2 1045 0.38 10.6 1092 0.50 11.0 1142 0.63 11.6 1196 0.79 12.4 1256 0.99 13.6 1316 1.21 15.0 1376 1.46 16.5 1441 1.76 18.3 Static Pressure in Inches wg 1.25 1.5 1.75 1144 0.45 10.9 1181 0.57 11.3 1229 0.73 12.0 1279 0.89 13.1 1332 1.08 14.5 1393 1.33 16.0 1452 1.59 17.6 1512 1.90 19.4 1263 0.64 12.0 1309 0.81 13.0 1357 1.00 14.2 1407 1.20 15.6 1461 1.43 17.1 1522 1.72 18.8 1581 2.04 21 1349 0.73 13.3 1383 0.89 14.2 1430 1.09 15.5 1479 1.32 16.8 1529 1.56 18.3 1585 1.84 20 1645 2.18 22 2 1430 0.81 14.7 1456 0.97 15.5 1499 1.18 16.8 1546 1.43 18.1 1596 1.69 19.8 1647 1.97 22 2.25 2.5 1531 1.02 17.0 1564 1.27 18.1 1611 1.53 19.8 1603 1.17 18.7 1629 1.37 19.9 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 21 SFB-12 - Belt Drive 213⁄8 (543) 93⁄4 131⁄4 151⁄2 9 (394) (229) 2 (51) mc urve (248) 135⁄8 (337) 283⁄8 yste (346) 13 (330) 221⁄4 11⁄2 151⁄8 of t his s (721) (565) (38) 16 (406) lec t to the left (384) 12 (305) ot se 207⁄8 (530) 221⁄2 (572) 167⁄8 (429) Do n Wheel Diameter = 125⁄8 (321) Shaft Diameter = 3/4 (19) Outlet Area = 0.856 ft2 (0.08 m2) ^Approximate Unit Weight = 147 lb. (67 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor Maximum BHP at given RPM = (RPM/1111)3 (Maximum KW at a given RPM = (RPM/1225)3) Maximum RPM = 1400 and Minimum RPM = 370 Tip Speed (ft/min.) = RPM x 3.30 (Tip Speed (m/s) = RPM x 0.0168) SFB-12 CFM Maximum Motor Frame Size = 145T OV 825 964 1065 1244 1305 1525 1545 1805 1785 2086 2025 2367 2265 2647 2505 2928 2745 3208 2985 3489 3225 3769 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 455 0.07 5.7 493 0.12 6.3 533 0.18 7.1 580 0.26 8.2 632 0.36 9.6 686 0.49 11.0 747 0.67 11.8 809 0.88 13.0 873 1.13 14.5 937 1.43 16.1 1002 1.77 17.8 0.5 0.75 1 631 0.18 9.3 665 0.25 10.2 703 0.35 10.5 743 0.47 10.7 789 0.61 11.4 837 0.79 12.2 889 1.00 13.2 943 1.26 14.4 1001 1.56 15.8 1062 1.92 17.4 773 0.33 10.3 806 0.43 10.6 844 0.57 11.1 883 0.74 11.8 925 0.93 12.6 971 1.15 13.5 1019 1.41 14.6 1071 1.72 16.2 1124 2.08 17.8 871 0.40 10.5 897 0.52 11.0 931 0.67 11.5 969 0.85 12.2 1008 1.06 12.9 1048 1.30 14.1 1093 1.58 15.6 1140 1.90 17.1 Static Pressure in Inches wg 1.25 1.5 1.75 983 0.62 11.3 1010 0.77 11.8 1045 0.96 12.7 1083 1.19 13.9 1122 1.45 15.3 1162 1.75 16.7 1205 2.08 18.2 1061 0.71 12.0 1087 0.88 13.0 1116 1.07 14.0 1152 1.31 15.2 1190 1.59 16.6 1230 1.91 18.0 1158 0.99 14.4 1185 1.19 15.5 1217 1.44 16.6 1254 1.73 17.9 1292 2.06 19.5 2 2.25 2.5 1225 1.09 16.0 1251 1.32 17.0 1278 1.56 18.1 1314 1.87 19.5 1313 1.44 18.6 1340 1.70 19.8 1370 2.00 21 1373 1.56 20 1399 1.84 22 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 22 SFB-15 - Belt Drive 233⁄8 (594) 105⁄8 123⁄4 213⁄4 (270) 2 (324) (51) curv e (552) 16 145⁄8 stem (406) (371) 11⁄2 of th i (391) 243⁄4 165⁄8 s sy 153⁄8 311⁄4 (371) (629) 175⁄8 (448) ele ct to the left (38) (422) 13 (330) no ts 30 (762) 325⁄8 (829) 187⁄8 (479) Do Wheel Diameter = 15 (381) Shaft Diameter = 1 (25) Outlet Area = 1.39 ft2 (0.129 m2) Mounting Hole Size = 1/2 (13) ^Approximate Unit Weight = 214 lb. (97 kg) cfm Maximum BHP at given RPM = (RPM/720)3 All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/794)3) Maximum RPM = 1200 and Minimum RPM = 380 Tip Speed (ft/min.) = RPM x 3.93 (Tip Speed (m/s) = RPM x 0.0200) SFB-15 CFM Maximum Motor Frame Size = 184T OV 1560 1125 1860 1342 2160 1558 2460 1775 2760 1991 3060 2208 3360 2424 3660 2641 3960 2857 4260 3074 4560 3290 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 395 0.16 6.0 421 0.23 7.5 450 0.32 9.9 481 0.42 10.9 514 0.56 11.5 549 0.72 12.7 585 0.91 14.1 623 1.14 15.9 662 1.41 17.8 701 1.71 18.9 742 2.06 20 0.5 508 0.25 8.1 529 0.33 8.8 554 0.44 9.6 580 0.56 10.6 608 0.71 11.9 637 0.89 13.5 668 1.11 14.9 701 1.35 16.0 734 1.63 17.3 768 1.95 18.6 804 2.32 19.8 0.75 1 619 0.43 9.4 638 0.55 10.3 663 0.70 11.4 688 0.87 12.3 715 1.07 13.2 742 1.29 14.0 772 1.56 14.7 802 1.86 15.9 834 2.20 17.2 867 2.59 18.8 716 0.67 11.2 734 0.83 12.0 759 1.03 12.8 784 1.24 13.5 810 1.49 14.1 837 1.76 14.7 865 2.07 15.4 895 2.44 16.6 925 2.85 18.4 Static Pressure in Inches wg 1.25 1.5 1.75 803 0.97 13.4 822 1.17 14.0 846 1.41 14.6 871 1.68 15.0 897 1.98 15.4 924 2.31 16.3 951 2.67 17.6 980 3.09 19.2 865 1.09 15.2 884 1.32 15.6 903 1.57 16.0 928 1.87 16.5 953 2.18 17.0 979 2.54 17.7 1005 2.93 18.9 1032 3.35 20 941 1.47 17.2 959 1.74 17.5 980 2.04 17.9 1005 2.39 18.6 1030 2.76 19.3 1056 3.17 20 1082 3.63 22 2 2.5 2.75 1013 1.90 19.0 1031 2.22 19.4 1053 2.58 20 1078 2.98 21 1103 3.41 22 1129 3.89 23 1128 2.58 22 1147 2.98 23 1166 3.40 23 1191 3.88 24 1174 2.75 24 1192 3.17 24 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 23 SFB-18 - Belt Drive 307⁄8 (784) 22 133⁄4 (349) 2 (451) (51) curv e 195⁄8 173⁄4 (559) stem 193⁄8 (498) 42 (1067) 191⁄4 331⁄4 11⁄2 223⁄8 of t his sy (492) (489) (845) 233⁄8 (594) 251⁄8 (638) ct to th e (568) left (38) ts ele 18 (457) no 35 (889) 367⁄8 (937) Do cfm Wheel Diameter = 181⁄8 (460) Shaft Diameter = 1 (25) Outlet Area = 2.29 ft2 (0.213 m2) Mounting Hole Size = 1/2 (13) ^Approximate Unit Weight = 265 lb. (120 kg) Maximum BHP at given RPM = (RPM/614)3 All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/677)3) Maximum RPM = 1050 and Minimum RPM = 310 Tip Speed (ft/min.) = RPM x 4.75 (Tip Speed (m/s) = RPM x 0.0241) SFB-18 CFM Maximum Motor Frame Size = 184T OV 2725 1188 3150 1374 3575 1559 4000 1744 4425 1930 4850 2115 5275 2300 5700 2486 6125 2671 6550 2857 6975 3042 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 364 0.29 8.4 388 0.39 10.3 415 0.52 11.1 444 0.68 12.0 473 0.87 13.6 503 1.09 15.5 534 1.36 17.7 566 1.67 19.2 599 2.03 20 631 2.43 22 664 2.88 24 0.5 464 0.44 9.2 481 0.56 10.1 500 0.70 11.3 524 0.89 13.1 548 1.09 14.7 573 1.34 15.8 601 1.63 17.1 630 1.96 18.6 660 2.34 20 689 2.76 21 720 3.23 23 0.75 550 0.60 10.2 563 0.74 11.2 578 0.90 12.2 596 1.10 13.1 615 1.32 14.0 638 1.59 14.8 662 1.90 15.6 687 2.24 16.9 714 2.64 18.5 743 3.09 20 771 3.60 23 1 635 0.93 12.6 648 1.11 13.4 662 1.32 14.0 680 1.57 14.4 698 1.85 14.8 719 2.17 15.6 743 2.55 16.6 767 2.96 18.0 791 3.41 20 818 3.93 22 Static Pressure in Inches wg 1.25 1.5 1.75 712 1.33 15.5 725 1.56 15.8 738 1.81 15.9 756 2.12 16.2 774 2.46 16.7 793 2.83 17.9 817 3.28 19.4 840 3.77 21 865 4.30 23 782 1.80 17.7 795 2.08 17.8 809 2.38 18.1 826 2.75 18.7 844 3.15 19.5 863 3.58 21 886 4.10 22 909 4.67 24 836 2.03 19.5 848 2.34 19.7 861 2.68 20 875 3.04 20 893 3.47 21 911 3.94 22 929 4.43 24 951 5.02 26 2 2.25 898 2.60 21 910 2.97 22 923 3.35 22 938 3.78 23 956 4.28 24 974 4.81 26 992 5.38 27 943 2.86 23 957 3.26 24 970 3.67 24 982 4.11 25 998 4.61 26 1016 5.18 27 1034 5.78 29 2.5 1001 3.54 25 1013 3.99 26 1026 4.46 26 1039 4.95 27 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 24 SFB-20 - Belt Drive 335⁄8 (854) 147⁄8 233⁄4 157⁄8 (603) (403) 2 (51) 22 (559) s ys tem 211⁄2 (546) curv e (378) 211⁄8 361⁄8 (918) of t 11⁄2 241⁄2 (537) his 46 (1168) left (38) t to the (622) ts ele c 191⁄2 (495) 255⁄8 (651) 35 (889) 37 (940) 27 ⁄8 (695) 3 n Do cfm Wheel Diameter = 20 (508) Shaft Diameter = 11⁄4 (32) Outlet Area = 2.40 ft2 (0.223 m2) Mounting Hole Size = 5/8 (16) ^Approximate Unit Weight = 405 lb (184 kg) Maximum BHP at given RPM = (RPM/485)3 All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/535)3) Maximum RPM = 950 and Minimum RPM = 270 Tip Speed (ft/min.) = RPM x 5.24 (Tip Speed (m/s) = RPM x 0.0266) SFB-20 CFM Maximum Motor Frame Size = 215T OV 3275 1362 3800 1581 4325 1799 4850 2018 5375 2236 5900 2455 6425 2673 6950 2892 7475 3110 8000 3329 8525 3547 o RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 320 0.37 8.1 343 0.51 10.3 369 0.70 11.3 396 0.92 12.3 424 1.19 14.0 454 1.52 16.1 484 1.90 18.6 515 2.36 20 546 2.88 22 578 3.47 24 610 4.14 26 0.5 402 0.53 9.1 420 0.70 10.1 440 0.90 11.5 462 1.15 13.4 485 1.45 15.4 511 1.80 16.8 537 2.22 18.4 565 2.69 19.8 593 3.24 21 622 3.86 23 652 4.55 24 0.75 1 487 0.90 11.3 503 1.13 12.6 521 1.39 13.7 542 1.71 14.7 564 2.08 15.5 587 2.52 16.8 612 3.02 18.5 638 3.59 20 665 4.24 22 692 4.96 24 561 1.36 13.1 576 1.64 13.9 594 1.99 14.5 614 2.38 15.3 634 2.83 16.1 657 3.36 17.0 681 3.95 19.2 705 4.61 22 731 5.37 24 Static Pressure in Inches wg 1.25 1.5 1.75 613 1.61 14.6 628 1.91 15.0 642 2.26 15.3 661 2.68 15.5 679 3.15 16.5 700 3.70 18.0 722 4.30 19.5 745 5.00 22 769 5.77 24 676 2.19 16.7 689 2.56 16.9 704 2.98 17.3 722 3.49 18.0 741 4.04 19.3 761 4.68 21 782 5.38 23 805 6.18 25 733 2.87 18.6 747 3.30 19.0 762 3.81 19.8 780 4.41 21 799 5.05 22 819 5.79 24 840 6.59 26 2 2.5 2.75 788 3.64 21 801 4.15 21 818 4.76 22 836 5.44 24 854 6.18 25 875 7.02 28 877 4.89 24 890 5.51 25 904 6.20 27 922 7.02 29 940 7.89 31 911 5.26 26 925 5.92 26 938 6.61 28 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 25 SFB-22 - Belt Drive 363⁄4 16 233⁄4 275⁄8 (603) (702) 24 171⁄2 (610) (445) 21⁄2 (64) curv e (406) stem (933) (584) 411⁄2 11⁄2 283⁄4 of t his sy 23 521⁄2 (1334) (1054) 281⁄4 (718) se lec t to t he (730) left (38) 20 (508) no t 341⁄8 (867) 395⁄8 (1006) 303⁄4 (781) Do Wheel Diameter = 221⁄4 (565) Shaft Diameter = 11⁄4 (32) Outlet Area = 3.23 ft2 (0.300 m2) Mounting Hole Size = 5/8 (16) ^Approximate Unit Weight = 540 lb (245 kg) cfm Maximum BHP at given RPM = (RPM/418)3 All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/461)3) Maximum RPM = 900 and Minimum RPM = 240 Tip Speed (ft/min.) = RPM x 5.79 (Tip Speed (m/s) = RPM x 0.0294) SFB-22 CFM Maximum Motor Frame Size = 215T OV 4000 1240 4950 1534 5900 1829 6850 2123 7800 2418 8750 2712 9700 3007 10650 3301 11600 3596 12550 3890 13500 4185 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 285 0.44 8.6 315 0.71 11.3 350 1.09 14.1 388 1.60 17.2 428 2.25 21 470 3.08 24 512 4.09 27 555 5.33 30 599 6.79 34 643 8.51 38 688 10.5 42 0.5 359 0.64 10.5 385 0.96 13 410 1.37 15.9 441 1.91 19.3 475 2.61 22 511 3.47 25 550 4.53 28 590 5.80 32 631 7.30 37 672 9.04 40 714 11.1 44 0.75 419 0.83 12.8 441 1.20 15.4 467 1.68 17.9 491 2.25 20 520 2.98 23 552 3.87 26 587 4.97 30 623 6.27 34 662 7.83 38 701 9.62 42 742 11.7 46 1 Static Pressure in Inches wg 1.25 1.5 2 491 1.43 16.6 514 1.96 19 540 2.61 22 564 3.37 25 593 4.30 28 624 5.43 31 658 6.77 35 693 8.34 38 730 10.17 42 768 12.3 47 535 1.67 18 557 2.23 20 582 2.95 23 608 3.79 26 632 4.75 30 660 5.90 32 691 7.28 36 724 8.88 39 759 10.76 43 794 12.9 48 598 2.52 22 620 3.26 24 646 4.17 28 671 5.21 30 695 6.39 34 724 7.79 37 755 9.44 41 788 11.33 45 822 13.5 49 691 3.92 26 713 4.88 29 739 6.08 32 764 7.41 36 789 8.90 40 813 10.54 44 844 12.56 48 875 14.8 53 2.5 755 4.56 29 776 5.64 31 798 6.87 34 824 8.35 39 850 10 43 874 11.82 47 898 13.8 52 3 3.25 834 6.38 34 854 7.71 37 877 9.24 41 861 6.75 36 881 8.14 39 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 26 SFB-25 - Belt Drive 403⁄8 (1026) 171⁄2 25 (445) 191⁄2 21⁄2 (495) (64) mc urve (635) 315⁄8 261⁄4 573⁄4 257⁄8 453⁄4 11⁄2 311⁄2 (657) (1162) the left of (1467) this syst e (803) (667) (38) 311⁄8 (791) ele ct to (800) no 36 (914) 411⁄2 (1054) 33 ⁄8 (854) ts 197⁄8 (505) 5 Do Wheel Diameter = 25 (635) Shaft Diameter = 11⁄2 (38) Outlet Area = 4.21 ft2(0.391 m2) Mounting Hole Size = 5/8 (16) ^Approximate Unit Weight = 700 lb. (318 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor Maximum Motor Frame Size = 284T OV 6000 1425 6950 1651 7900 1877 8850 2103 9800 2329 10750 2554 11700 2780 12650 3006 13600 3232 14550 3457 15500 3683 (Maximum KW at a given RPM = (RPM/335)3) Maximum RPM = 750 and Minimum RPM = 190 Tip Speed (ft/min.) = RPM x 6.54 (Tip Speed (m/s) = RPM x 0.0332) SFB-25 CFM Maximum BHP at given RPM = (RPM/304)3 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 246 0.74 8.4 263 1.02 10.3 283 1.39 12.1 304 1.85 14.1 326 2.40 16.1 349 3.07 18.4 373 3.86 21 397 4.78 23 421 5.84 25 445 7.04 27 471 8.43 29 0.5 310 1.03 10.4 324 1.37 11.9 338 1.78 13.7 354 2.29 15.7 372 2.87 18.0 391 3.58 20 412 4.42 22 433 5.37 24 455 6.46 26 478 7.72 29 501 9.15 31 0.75 363 1.32 12.5 375 1.72 14.3 387 2.17 16.2 401 2.73 17.9 416 3.36 19.6 432 4.12 21 450 4.99 23 468 5.96 25 488 7.13 27 510 8.43 30 531 9.88 33 Static Pressure in Inches wg 1 1.25 1.5 2 412 1.65 14.5 419 463 2.05 2.42 15.8 17.3 431 470 508 2.57 2.95 3.34 17.3 18.6 20 444 482 518 585 3.15 3.61 4.03 4.93 19.0 20 22 25 457 495 530 593 3.86 4.32 4.83 5.76 21 22 23 26 471 508 542 605 4.65 5.19 5.70 6.79 23 24 25 27 487 522 556 617 5.57 6.16 6.73 7.89 25 26 28 29 504 537 569 629 6.62 7.22 7.88 9.07 27 28 30 32 521 553 584 643 7.79 8.48 9.13 10.51 29 31 32 34 539 570 600 657 9.09 9.86 10.58 12.04 31 33 34 36 559 588 617 671 10.62 11.37 12.18 13.68 34 35 36 39 2.5 654 6.81 29 660 7.78 30 672 9.05 32 684 10.39 34 696 11.82 36 709 13.43 39 723 15.26 42 3 3.25 716 8.96 33 722 10.11 35 734 11.62 36 746 13.21 39 743 9.57 35 748 10.74 36 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 27 SFB-27 - Belt Drive 44 (1118) 19 27 (483) 213⁄8 (543) 21⁄2 (64) urve 281⁄8 (686) of t his sys tem c 341⁄2 (714) (876) 281⁄2 611⁄8 (1553) (724) 491⁄8 35⁄8 (1248) 33 351⁄8 (892) 375⁄8 (956) el e ct to the (838) left (92) 401⁄2 (1029) 46 (1168) no ts 221⁄4 (565) Do Wheel Diameter = 271⁄2 (699) Shaft Diameter = 11⁄2 (38) Outlet Area = 4.97 ft2 (0.462 m2) Mounting Hole Size = 5/8 (16) ^Approximate Unit Weight = 845 lb. (383 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/314)3) Maximum RPM = 700 and Minimum RPM = 200 Tip Speed (ft/min.) = RPM x 7.20 (Tip Speed (m/s) = RPM x 0.0366) SFB-27 CFM Maximum BHP at given RPM = (RPM/285)3 Maximum Motor Frame Size = 286T OV 8600 1729 9750 1961 10900 2192 12050 2423 13200 2655 14350 2886 15500 3117 16650 3349 17800 3580 18950 3811 20100 4043 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 245 1.29 11.1 264 1.75 13.1 284 2.31 15.1 305 3.02 17.3 327 3.85 19.8 349 4.83 22 372 5.97 25 395 7.27 27 418 8.76 29 441 10.40 32 465 12.40 34 0.5 297 1.72 12.5 310 2.21 14.6 327 2.84 16.7 344 3.58 19.2 363 4.46 22 382 5.47 24 403 6.64 26 424 8.02 28 446 9.59 31 468 11.30 34 490 13.30 37 0.75 345 2.17 15.1 355 2.71 17.0 368 3.38 18.9 381 4.14 21 398 5.09 23 415 6.16 25 434 7.40 27 453 8.80 29 472 10.37 32 492 12.10 35 514 14.20 39 Static Pressure in Inches wg 1 1.25 1.5 2 388 427 462 2.61 3.07 3.56 16.7 18.2 20 397 434 470 3.23 3.73 4.26 18.4 19.7 21 407 444 477 540 3.94 4.51 5.05 6.24 20 21 23 26 419 454 487 547 4.78 5.39 6.03 7.28 22 23 25 27 432 465 497 556 5.73 6.41 7.09 8.45 24 25 27 29 447 478 508 566 6.83 7.57 8.30 9.80 26 28 29 31 464 491 521 576 8.14 8.84 9.68 11.25 28 30 32 34 481 508 535 588 9.60 10.38 11.17 12.90 31 33 34 36 499 525 550 601 11.24 12.10 12.92 14.74 34 35 36 39 518 543 567 614 13.10 14.00 14.90 16.70 37 38 39 41 538 561 585 629 15.10 16.10 17.10 18.90 39 40 41 44 2.5 3 603 8.58 30 610 9.86 32 618 11.22 33 628 12.88 36 638 14.64 39 648 16.49 41 661 18.70 44 674 21.00 47 652 9.95 34 660 11.28 35 668 12.80 37 676 14.41 39 685 16.36 41 695 18.42 44 3.25 683 12.04 37 691 13.58 39 699 15.28 40 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 28 SFB-30 - Belt Drive 483⁄4 21 27 (533) 313⁄8 367⁄8 (797) (937) 233⁄8 (594) 21⁄2 (64) em c urve (686) syst (1238) 313⁄4 68 11⁄2 365⁄8 of t his (806) 533⁄4 (1727) (1365) ct to the left (38) (930) no o 423⁄4 (1086) 481⁄4 (1226) ts el e 221⁄2 (572) 383⁄8 (975) 411⁄8 (1045) D Wheel Diameter = 30 (762) Shaft Diameter = 11⁄2 (38) Outlet Area = 5.72 ft2 (0.531 m2) Mounting Hole Size = 5/8 (16) ^Approximate Unit Weight = 940 lb. (426 kg) cfm All dimensions in inches (millimeters) For additional discharge positions see page 14 ^Weight shown is largest cataloged Open Drip Proof motor 11525 2015 13050 2282 14575 2549 16100 2816 17625 3082 19150 3349 20675 3616 22200 3883 23725 4149 25250 4416 Maximum RPM = 650 and Minimum RPM = 175 Tip Speed (ft/min.) = RPM x 7.86 Maximum Motor Frame Size = 286T OV 10000 1749 (Maximum KW at a given RPM = (RPM/263)3) (Tip Speed (m/s) = RPM x 0.0399) SFB-30 CFM Maximum BHP at given RPM = (RPM/239)3 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 245 1.60 13.0 267 2.25 15.7 291 3.10 18.7 316 4.14 22 342 5.42 25 369 6.98 28 397 8.82 31 424 11.00 35 452 13.40 39 480 16.20 43 508 19.40 46 0.5 293 2.12 15.0 311 2.85 17.9 330 3.73 21 352 4.85 23 375 6.18 26 399 7.78 29 423 9.65 33 448 11.80 37 474 14.30 42 501 17.20 45 528 20.50 49 0.75 332 2.59 17.3 350 3.44 19.7 368 4.44 22 387 5.60 25 406 6.96 28 428 8.64 31 450 10.57 35 474 12.80 39 498 15.40 42 523 18.30 46 548 21.50 51 Static Pressure in Inches wg 1 1.25 1.5 2 369 403 434 3.13 3.63 4.19 18.6 20 22 383 416 446 501 3.98 4.60 5.19 6.43 21 22 24 27 401 430 459 513 5.09 5.69 6.39 7.73 24 25 27 29 419 448 474 526 6.37 7.10 7.78 9.31 27 28 30 31 437 466 492 539 7.84 8.69 9.49 11.02 30 32 33 35 456 484 510 557 9.51 10.49 11.40 13.12 33 35 36 38 477 503 529 575 11.50 12.50 13.55 15.51 36 38 39 42 499 523 547 593 13.80 14.80 15.90 18.10 40 41 43 46 521 545 566 612 16.40 17.50 18.60 21.00 43 45 46 50 545 567 588 630 19.40 20.60 21.70 24.20 47 49 51 55 569 589 610 649 22.80 23.90 25.20 27.70 52 53 55 59 2.5 3 3.25 562 9.15 32 573 10.79 34 586 12.74 37 600 14.86 41 616 17.32 45 634 20.20 49 606 10.56 35 617 12.37 38 629 14.38 40 642 16.73 44 638 13.16 40 649 15.20 42 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 29 SWB-106 - Belt Drive Series 100 183⁄4 3.5 (219) (508) (248) 2 (51) 11 26 ⁄8 (279) 211⁄4 (676) 11⁄2 15 ⁄8 1 (540) (384) 0.0 0 0 16 00 1135 0 0.5 30 0 Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.76 ft2 (0.07 m 2 ) ^Approximate Unit Weight = 135 lb. (61 kg) 1.0 25 16 ⁄8 (429) 1.5 2 1 251⁄4 (641) 263⁄4 (679) 7 3 65 153⁄4 (400) 4 ¼ 2.0 20 16 (406) 5 300 (38) 6 2.5 Do (286) 3 Static Pressure (in. wg) (292) 5 Static Pressure (Pa x 100) 111⁄4 RPM HP Density 0.075 lb/ft3 3.0 7 111⁄2 ½ 8 this syst em c urve 93⁄4 the left of 20 sel ect to 85⁄8 no t (476) 670 100 200 200 300 Volume (cfm) 400 400 600 500 800 1000 Volume (m3/hr) Maximum BHP at a given RPM = (RPM/3706)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/4086)3) Maximum RPM = 3000 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-106 CFM Maximum Motor Frame Size = 145T OV 100 132 140 184 180 237 220 289 260 342 300 395 340 447 380 500 420 553 460 605 500 658 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 936 0.02 5.4 1023 0.02 6.0 1172 0.03 6.6 1356 0.05 7.2 1550 0.07 8.0 1749 0.09 9.1 1952 0.13 10.5 2156 0.17 12.2 2361 0.23 14.7 2567 0.29 17.9 2775 0.37 22 0.5 1273 0.04 6.8 1322 0.04 7.1 1398 0.05 7.5 1522 0.07 8.2 1681 0.09 9.0 1866 0.12 10.1 2056 0.15 11.5 2253 0.20 12.8 2452 0.26 14.2 2654 0.32 16.2 2858 0.40 22 0.75 1542 0.06 8.0 1574 0.07 8.4 1632 0.08 8.9 1712 0.10 9.4 1830 0.12 10.2 1976 0.15 11.3 2158 0.19 12.5 2344 0.23 13.7 2535 0.29 15.1 2732 0.36 16.9 2931 0.44 18.9 1 1799 0.11 9.8 1843 0.12 10.2 1906 0.13 10.9 1993 0.15 11.8 2113 0.18 12.8 2258 0.22 13.7 2434 0.27 14.7 2618 0.33 16.1 2806 0.40 17.8 Static Pressure in Inches wg 1.25 1.5 1.75 1999 0.14 11.5 2031 0.16 11.9 2088 0.17 12.6 2155 0.19 13.2 2253 0.22 14.0 2379 0.26 14.9 2524 0.31 16.2 2699 0.37 17.2 2883 0.44 18.9 2179 0.18 13.1 2210 0.20 13.4 2257 0.22 13.9 2318 0.24 14.5 2391 0.27 15.2 2500 0.31 16.2 2633 0.35 17.4 2779 0.42 18.8 2956 0.49 19.8 2376 0.24 14.8 2413 0.26 15.2 2470 0.29 15.9 2537 0.32 16.6 2626 0.35 17.5 2736 0.40 18.6 2879 0.46 20 2 2.25 2.5 2531 0.29 16.3 2561 0.31 16.7 2614 0.34 17.4 2676 0.37 18.0 2745 0.41 18.7 2852 0.45 19.9 2973 0.51 21 2676 0.34 17.9 2706 0.37 18.3 2751 0.39 18.8 2808 0.42 19.5 2876 0.46 20 2963 0.51 21 2813 0.39 19.4 2844 0.42 19.8 2880 0.45 20 2936 0.48 21 3000 0.52 22 Performance certified is for installation Type B - free inlet, ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 30 600 SWB-107 - Belt Drive Series 100 183⁄4 3.5 20 93⁄4 (219) (508) (248) 2 ½ 8 (51) 3.0 3 (540) syst em this 05 0.5 20 251⁄4 (641) 263⁄4 (679) 1.0 2 1 153⁄4 (400) 16 (406) 167⁄8 (429) 1.5 15 1115 00 (384) 3 50 24 (38) 4 2.0 29 11⁄2 151⁄8 5 the left of (279) 211⁄4 ¼ 2.5 no ts ele ct to 11 265⁄8 (676) 6 Do 111⁄4 (286) Static Pressure (in. wg) 111⁄2 Static Pressure (Pa x 100) 7 (292) RPM HP Density 0.075 lb/ft3 curv e 85⁄8 ¾ (476) 60 670 0 Wheel Diameter = 11 ⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.76 ft2 (0.07 m 2 ) ^Approximate Unit Weight = 135 lb. (61 kg) 0.0 0 100 200 300 400 500 Volume (cfm) 600 700 800 3 0 200 400 600 800 1000 1200 Volume (m3/hr) Maximum BHP at a given RPM = (RPM/3706)3 (Maximum KW at a given RPM = (RPM/3851)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2900 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-107 CFM Maximum Motor Frame Size = 145T OV 140 184 200 263 260 342 320 421 380 500 440 579 500 658 560 737 620 816 680 895 740 974 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 891 0.02 4.5 1008 0.02 5.1 1184 0.04 6.0 1372 0.06 7.3 1573 0.09 8.6 1782 0.12 10.1 1994 0.17 11.8 2208 0.23 14.1 2421 0.30 16.6 2636 0.39 19.5 2852 0.50 23 0.5 1198 0.04 5.9 1264 0.04 6.2 1374 0.06 6.8 1531 0.08 7.7 1713 0.11 8.9 1900 0.15 10.6 2096 0.20 12.3 2302 0.27 14.1 2512 0.34 17.0 2723 0.44 22 Static Pressure in Inches wg 1.25 1.5 1.75 0.75 1 1494 0.07 7.3 1572 0.09 7.7 1686 0.11 8.4 1840 0.14 9.7 2020 0.19 11.3 2205 0.24 12.9 2394 0.30 14.7 2593 0.38 16.7 2799 0.48 19.0 1695 0.10 8.5 1759 0.12 8.8 1848 0.14 9.5 1970 0.18 10.7 2129 0.22 12.0 2308 0.28 13.5 2492 0.35 15.5 2680 0.43 17.6 2872 0.52 19.9 1877 0.13 9.8 1931 0.15 10.1 2005 0.18 10.6 2105 0.21 11.6 2238 0.26 12.7 2404 0.32 14.2 2583 0.39 16.1 2767 0.48 18.5 2088 0.19 11.3 2156 0.22 11.8 2244 0.25 12.6 2358 0.30 13.7 2493 0.36 14.9 2669 0.44 16.8 2850 0.53 19.1 2239 0.23 12.6 2299 0.26 13.0 2375 0.30 13.7 2472 0.34 14.7 2601 0.41 16.1 2751 0.48 17.5 2 2.25 2.5 2380 0.27 13.8 2432 0.30 14.2 2502 0.34 14.9 2593 0.39 15.9 2705 0.45 17.2 2838 0.53 18.4 2512 0.32 15.2 2559 0.35 15.6 2627 0.39 16.3 2708 0.44 17.2 2805 0.50 18.3 2684 0.40 17.0 2745 0.44 17.6 2817 0.49 18.5 Performance certified is for installation Type B - free inlet, ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 31 SWB-108 - Belt Drive Series 100 4.0 85⁄8 (219) 20 93⁄4 (508) (248) 9 (51) 3.5 ½ 8 26 ⁄8 (279) 211⁄4 (676) 11⁄2 15 ⁄8 1 (540) (38) (384) 6 5 4 3 3 2.5 ¼ 2.0 1.5 1.0 1 25 ⁄4 (641) 263⁄4 (679) 0.5 1 0 Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.76 ft2 (0.07 m 2 ) ^Approximate Unit Weight = 135 lb. (61 kg) Do 153⁄4 (400) 0 2 2 25 50 0 670 0.0 0 19 15 110 75 16 (406) 167⁄8 (429) 23 2 00 28 Static Pressure (Pa x 100) 11 this sy (286) 5 to t he left of (292) 3.0 7 no ts ele ct 11 ⁄4 1 Static Pressure (in. wg) 11 ⁄2 1 RPM HP Density 0.075 lb/ft3 ¾ 2 stem curv e 183⁄4 (476) 4 4 6 6 8 Volume (cfm x 100) 8 10 10 12 14 16 Volume (m3/hr x 100) 12 18 20 14 22 Maximum BHP at a given RPM = (RPM/3233)3 (Maximum KW at a given RPM = (RPM/3564)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2800 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-108 CFM Maximum Motor Frame Size = 145T OV 200 263 300 395 400 526 500 658 600 789 700 921 800 1053 900 1184 1000 1316 1100 1447 1200 1579 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 860 0.02 5.5 982 0.03 6.6 1141 0.04 7.2 1317 0.07 8.0 1504 0.09 9.1 1699 0.13 10.3 1899 0.18 12.1 2102 0.24 13.9 2308 0.32 15.6 2517 0.41 18.7 2728 0.52 23 0.5 1148 0.04 6.8 1235 0.05 7.0 1357 0.07 7.7 1506 0.10 8.6 1673 0.14 9.8 1849 0.18 11.5 2035 0.23 13.3 2227 0.30 14.7 2423 0.38 16.6 2623 0.48 18.7 0.75 1 1443 0.09 7.7 1551 0.11 8.2 1675 0.14 9.2 1825 0.18 10.5 1989 0.23 12.5 2162 0.29 13.9 2344 0.37 15.5 2531 0.45 17.4 2723 0.55 19.7 1635 0.12 8.7 1719 0.15 9.0 1837 0.18 9.8 1965 0.22 11.2 2119 0.28 12.9 2282 0.34 14.5 2455 0.43 16.2 2634 0.53 18.2 Static Pressure in Inches wg 1.25 1.5 1.75 1805 0.16 9.6 1872 0.19 9.8 1983 0.23 10.5 2105 0.27 11.8 2242 0.33 13.3 2396 0.40 15.0 2561 0.49 16.8 2733 0.59 18.9 2025 0.24 10.7 2117 0.28 11.1 2234 0.32 12.3 2361 0.39 13.9 2507 0.46 15.6 2662 0.54 17.4 2165 0.29 11.5 2241 0.33 12.0 2356 0.38 13.0 2478 0.44 14.6 2610 0.52 16.2 2763 0.61 18.1 2 2.25 2.5 2296 0.34 12.4 2364 0.39 12.9 2471 0.44 13.7 2589 0.50 14.8 2715 0.59 17.0 2419 0.40 13.5 2487 0.45 13.9 2579 0.50 14.6 2695 0.56 15.7 2603 0.51 14.8 2681 0.57 15.5 2796 0.63 16.6 Performance certified is for installation Type B - free inlet, ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 32 SWB-110 - Belt Drive Series 100 183⁄4 4.0 (219) 20 93⁄4 (508) (248) ¾ 2 9 ½ 3.5 (51) 3.0 151⁄8 (540) (38) (384) 5 4 3 ¼ 2.0 the le 11⁄2 3 2.5 1.5 ele ct to (279) 211⁄4 (676) 6 1.0 0.0 0 2 70 70 4 6 8 10 12 65 0 14 10 670 70 0.5 22 1 251⁄4 (641) 263⁄4 (679) 70 153⁄4 (400) 18 16 (406) 167⁄8 (429) Do 2 26 no ts 11 265⁄8 7 Static Pressure (in. wg) 111⁄4 (286) Static Pressure (Pa x 100) 111⁄2 ft o f th is s yste m 8 (292) RPM HP Density 0.075 lb/ft3 curv e 85⁄8 1 (476) 14 16 18 20 22 Volume (cfm X 100) Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.76 ft2 (0.07 m 2 ) ^Approximate Unit Weight = 135 lb. (61 kg) 0 5 10 15 20 25 30 35 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/2665)3 (Maximum KW at a given RPM = (RPM/2938)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2665 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-110 CFM Maximum Motor Frame Size = 145T OV 500 658 650 855 800 1053 950 1250 1100 1447 1250 1645 1400 1842 1550 2039 1700 2237 1850 2434 2000 2632 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 898 0.04 8.5 1040 0.06 9.0 1192 0.09 9.7 1353 0.13 10.6 1519 0.18 12.0 1688 0.25 14.2 1859 0.33 16.0 2033 0.43 18.3 2211 0.55 21 2391 0.69 24 2571 0.86 27 0.5 1094 0.07 8.8 1218 0.10 9.2 1356 0.13 9.9 1501 0.18 10.9 1653 0.24 12.7 1813 0.31 14.3 1976 0.40 16.3 2141 0.51 18.8 2310 0.63 22 2480 0.78 25 2652 0.96 27 0.75 1264 0.10 9.0 1368 0.13 9.4 1496 0.18 10.1 1633 0.23 11.6 1776 0.30 13.0 1924 0.37 14.8 2080 0.47 17.0 2241 0.59 19.6 2404 0.72 23 2569 0.88 25 1 1508 0.18 9.9 1621 0.22 10.9 1750 0.28 12.1 1888 0.36 13.4 2031 0.44 15.5 2179 0.54 17.8 2332 0.67 21 2491 0.81 24 2652 0.97 26 Static Pressure in Inches wg 1.25 1.5 1.75 1635 0.23 10.5 1735 0.27 11.5 1859 0.34 12.1 1991 0.42 13.9 2130 0.51 16.2 2274 0.62 18.9 2421 0.75 22 2573 0.89 24 1849 0.33 11.4 1961 0.39 12.6 2088 0.48 14.4 2222 0.58 17.0 2362 0.70 20 2506 0.83 23 2654 0.98 24 1955 0.39 12.1 2055 0.45 13.1 2179 0.54 15.0 2309 0.65 18.2 2446 0.77 22 2588 0.91 23 2 2.25 2.5 2054 0.45 13.3 2153 0.52 14.0 2267 0.61 16.1 2394 0.72 19.3 2526 0.85 23 2245 0.59 15.3 2349 0.67 17.3 2474 0.79 21 2603 0.93 22 2332 0.66 16.7 2433 0.75 18.6 2551 0.87 21 Performance certified is for installation Type B - free inlet, ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 33 SWB-113 - Belt Drive Series 100 233⁄8 4.0 9 (51) (362) 311⁄4 (794) 14 24 ⁄4 3 11⁄2 16 ⁄8 5 (356) (629) (38) (422) 7 6 5 4 3 Static Pressure (in. wg) Static Pressure (Pa x 100) (371) ½ 14 ⁄4 1 cur ve 8 3.0 145⁄8 2.5 3 2.0 ¼ 1.5 1.0 Wheel Diameter = 131⁄2 (343) Shaft Diameter = 3/4 (19) Outlet Area = 1.03 ft2 (0.10 m2) ^Approximate Unit Weight = 175 lb. (79 kg) no t 0 10 12 90 92 0 10 15 20 Volume (cfm X 100) 20 30 25 40 85 Do 550 5 0.0 0 30 0 60 27 ⁄2 (699) 301⁄8 (765) 187⁄8 (479) 20 0.5 1 1 16 13 (330) 23 2 175⁄8 (448) RPM HP Density 0.075 lb/ft3 3.5 em (552) 2 to the lef to f th is s yst (270) se lec t 21 ⁄4 (270) 1½ 105⁄8 3 1 105⁄8 ¾ (594) 30 50 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/2084) 3 (Maximum KW at a given RPM = (RPM/2298)3) All dimension in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2385 Tip Speed (ft/min.) = RPM x 3.53 (Tip Speed (m/s) = RPM x 0.0179) SWB-113 CFM Maximum Motor Frame Size = 184T OV 700 680 900 874 1100 1068 1300 1262 1500 1456 1700 1650 1900 1845 2100 2039 2300 2233 2500 2427 2700 2621 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 767 0.05 5.4 883 0.08 6.2 1009 0.11 7.4 1144 0.16 8.8 1283 0.22 10.0 1424 0.30 11.9 1569 0.39 13.8 1714 0.51 15.9 1860 0.64 18.1 2007 0.80 20 2154 0.99 22 0.5 939 0.09 5.7 1037 0.12 6.9 1147 0.17 8.5 1266 0.22 9.5 1391 0.29 10.8 1524 0.37 12.7 1659 0.48 14.6 1799 0.60 16.8 1940 0.75 19.0 2083 0.92 21 2228 1.12 23 0.75 1 1168 0.17 8.3 1269 0.22 9.1 1378 0.29 10.1 1494 0.37 11.5 1617 0.46 13.3 1745 0.57 15.3 1878 0.70 17.8 2014 0.85 19.7 2153 1.03 21 2293 1.24 24 1291 0.23 9.0 1378 0.28 9.7 1480 0.36 10.7 1591 0.44 12.2 1706 0.55 13.9 1828 0.66 16.1 1953 0.80 18.2 2085 0.96 20 2219 1.15 22 2356 1.36 24 Static Pressure in Inches wg 1.25 1.5 1.75 2 1482 0.35 10.2 1576 0.43 11.3 1680 0.52 12.9 1792 0.63 14.7 1907 0.76 16.9 2029 0.91 18.7 2153 1.08 21 2284 1.27 23 1580 0.41 11.0 1665 0.50 12.0 1766 0.60 13.6 1872 0.72 15.5 1984 0.86 17.4 2101 1.02 19.2 2222 1.19 21 2347 1.40 24 1753 0.58 12.8 1846 0.68 14.3 1948 0.81 16.2 2057 0.96 17.9 2170 1.13 19.8 2288 1.31 22 1837 0.65 13.8 1922 0.77 15.2 2023 0.91 16.7 2126 1.06 18.4 2238 1.24 20 2352 1.43 23 2.25 2.5 1916 0.73 15.1 1999 0.85 15.8 2093 1.00 17.2 2194 1.16 18.9 2302 1.35 21 2073 0.94 16.4 2161 1.09 17.8 2261 1.27 19.6 2364 1.46 22 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 34 35 SWB-115 - Belt Drive Series 100 253⁄4 4.0 (546) (295) 2 9 3.5 (51) 3.0 1 ⁄2 1 181⁄2 (403) (699) (38) (470) 5 4 3 lef to f th is s yst em 271⁄2 (883) 6 2.5 3 2.0 ¼ 1.5 1.0 2 21 ⁄8 (537) 0 Wheel Diameter = 14 ⁄4 (375) Shaft Diameter = 3/4 (19) Outlet Area = 1.25 ft2 (0.12 m2) ^Approximate Unit Weight = 225 lb. (102 kg) 0.5 0.0 0 Do 550 5 12 10 88 0 10 15 40 1 271⁄8 (689) 311⁄4 (794) 87 21 15 (381) 1 70 18 20 (508) 15 no ts ele ct to the 157⁄8 343⁄4 7 Static Pressure (in. wg) (400) Static Pressure (Pa x 100) (413) ½ 153⁄4 cur ve 8 161⁄4 RPM HP Density 0.075 lb/ft3 2 (295) 115⁄8 1½ 211⁄2 1 115⁄8 ¾ (654) 20 25 30 Volume (cfm X 100) 35 40 45 3 0 10 20 30 40 50 Volume (m3/hr x 100) 60 70 Maximum BHP at a given RPM = (RPM/1737)3 (Maximum KW at a given RPM = (RPM/1915)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2187 Tip Speed (ft/min.) = RPM x 3.93 (Tip Speed (m/s) = RPM x 0.0200) SWB-115 CFM Maximum Motor Frame Size = 184T OV 1000 800 1250 1000 1500 1200 1750 1400 2000 1600 2250 1800 2500 2000 2750 2200 3000 2400 3250 2600 3500 2800 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 737 0.08 6.2 843 0.11 6.9 955 0.16 8.2 1075 0.23 9.6 1196 0.32 11.1 1319 0.42 12.8 1444 0.55 14.7 1570 0.71 16.7 1698 0.89 19.0 1827 1.11 21 1956 1.35 24 0.5 879 0.13 6.7 976 0.18 7.8 1078 0.24 9.1 1184 0.31 10.3 1294 0.41 11.7 1412 0.53 13.4 1533 0.67 15.4 1654 0.84 17.6 1776 1.04 19.9 1899 1.26 22 2024 1.52 25 Static Pressure in Inches wg 1.25 1.5 1.75 0.75 1 1086 0.24 8.4 1183 0.32 9.6 1284 0.40 10.9 1389 0.51 12.4 1496 0.63 14.0 1609 0.78 16.0 1727 0.97 18.3 1847 1.18 20 1968 1.42 23 2090 1.69 25 1186 0.31 8.9 1276 0.39 10.1 1373 0.49 11.4 1474 0.61 13.0 1578 0.75 14.7 1685 0.91 16.7 1794 1.09 18.8 1911 1.31 21 2030 1.57 23 2150 1.86 26 1360 0.47 10.6 1455 0.58 12.0 1552 0.71 13.6 1654 0.86 15.4 1758 1.03 17.5 1864 1.23 19.4 1973 1.45 22 2088 1.71 24 1445 0.56 11.3 1530 0.67 12.5 1625 0.82 14.1 1724 0.98 16.0 1826 1.16 18.0 1931 1.37 20 2037 1.60 22 2146 1.87 24 1600 0.77 13.1 1695 0.92 14.7 1791 1.09 16.6 1891 1.29 18.7 1993 1.51 21 2098 1.76 23 2 2.25 2.5 1673 0.87 14.1 1759 1.02 15.3 1854 1.21 17.3 1952 1.42 19.4 2053 1.65 22 2156 1.91 24 1746 0.97 15.1 1821 1.13 16.1 1915 1.32 18.0 2010 1.55 20 2109 1.79 22 1883 1.24 17.1 1972 1.44 18.8 2067 1.67 21 2164 1.93 23 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 35 SWB-116 - Belt Drive Series 100 28 (318) (546) (324) 5 12 2 (51) 10 17 ⁄4 17 ⁄2 (451) (445) 3 4 1 17 ⁄2 1 (968) 30 1 ⁄2 1 203⁄8 (445) (762) (38) (518) 8 6 4 Static Pressure (in. wg) Static Pressure (Pa x 100) 1 381⁄8 ¾ 3 ½ 2 3 ¼ 1 0 0 400 5 10 10 50 72 5 15 20 25 30 23 20 0 75 301⁄4 (769) 323⁄8 (823) 13 Do 16 (406) 00 17 2 213⁄8 (543) 227⁄8 (581) RPM HP Density 0.075 lb/ft3 no ts ele ct to the lef to f th is s yst em cur ve 123⁄4 3 211⁄2 2 121⁄2 1½ (711) 35 40 45 50 Volume (cfm X 100) Wheel Diameter = 17 (432) Shaft Diameter = 1 (25) Outlet Area = 1.52 ft2 (0.14 m2) ^Approximate Unit Weight = 241 lb. (109 kg) 0 20 40 60 80 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/1403)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/1547)3) Maximum RPM = 2023 Tip Speed (ft/min.) = RPM x 4.32 (Tip Speed (m/s) = RPM x 0.0219) SWB-116 CFM Maximum Motor Frame Size = 184T OV 1200 789 1560 1026 1920 1263 2280 1500 2640 1737 3000 1974 3360 2211 3720 2447 4080 2684 4440 2921 4800 3158 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 750 0.15 5.8 846 0.22 7.1 949 0.31 8.8 1061 0.42 10.9 1182 0.57 13.5 1306 0.76 15.4 1432 0.99 17.6 1560 1.27 20 1690 1.60 23 1821 1.99 27 1953 2.44 32 0.75 1 1.25 943 0.30 7.8 1039 0.40 9.6 1141 0.53 11.8 1250 0.69 13.8 1369 0.89 15.8 1491 1.14 18.0 1615 1.43 21 1742 1.78 24 1869 2.18 28 1999 2.65 32 1026 0.38 8.7 1120 0.50 10.7 1216 0.65 12.5 1320 0.82 14.1 1429 1.03 16.1 1545 1.29 18.4 1667 1.60 21 1790 1.96 25 1916 2.38 28 1192 0.60 11.5 1287 0.76 12.9 1385 0.96 14.6 1490 1.18 16.6 1599 1.45 18.9 1716 1.76 22 1837 2.14 25 1960 2.58 29 Static Pressure in Inches wg 1.5 2 2.5 1259 0.71 12.0 1352 0.88 13.3 1448 1.09 15.1 1548 1.34 17.1 1654 1.62 19.6 1764 1.94 23 1881 2.32 26 2002 2.77 30 1470 1.12 14.4 1564 1.36 15.9 1659 1.64 18.6 1758 1.96 21 1863 2.32 24 1971 2.72 27 1576 1.38 16.4 1666 1.64 17.4 1761 1.95 19.9 1857 2.30 23 1955 2.70 25 2.75 3 3.5 1715 1.79 18.4 1808 2.11 21 1903 2.47 23 2001 2.89 26 1762 1.93 19.5 1853 2.26 21 1948 2.64 23 1851 2.23 22 1940 2.59 22 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 36 55 SWB-118 - Belt Drive Series 100 307⁄8 4.0 (350) (559) (359) 2 9 (51) 1 8 (1067) 331⁄4 1 ⁄2 1 223⁄8 (489) (845) (38) (568) 6 5 4 3 2.5 2.0 ½ 1.5 3 5 321⁄4 (817) 34 (864) 0 0.0 0 99 5 77 0 13 26 60 54 45 Do 0.5 14 1 20 177⁄8 (454) 233⁄8 (594) 25 (635) 16 1.0 2 12 no ts ele ct to the lef to f th is s 191⁄4 ¾ (492) 42 7 Static Pressure (in. wg) 193⁄8 (498) Static Pressure (Pa x 100) 3.0 195⁄8 RPM HP Density 0.075 lb/ft3 3 3.5 urv e 141⁄8 yst em c 22 2 133⁄4 1½ (784) 39 52 65 Volume (cfm X 100) Wheel Diameter = 19 (483) Shaft Diameter = 1 (25) Outlet Area = 1.87 ft2 (0.17 m2) ^Approximate Unit Weight = 312 lb. (142 kg) 0 20 40 60 80 100 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/1150)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/1268)3) Maximum RPM = 1660 Tip Speed (ft/min.) = RPM x 4.78 (Tip Speed (m/s) = RPM x 0.0243) SWB-118 CFM Maximum Motor Frame Size = 213T OV 1500 802 1900 1016 2300 1230 2700 1444 3100 1658 3500 1872 3900 2086 4300 2299 4700 2513 5100 2727 5500 2941 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 545 0.11 5.6 628 0.16 6.5 717 0.24 7.7 808 0.34 9.1 902 0.46 10.9 997 0.62 13.1 1095 0.82 15.5 1193 1.06 17.6 1291 1.34 20 1391 1.67 22 1491 2.05 24 0.5 667 0.19 6.6 728 0.25 7.2 806 0.34 8.2 892 0.46 9.8 980 0.61 11.7 1070 0.78 14.1 1162 1.00 16.3 1256 1.25 18.6 1351 1.55 21 1447 1.90 23 1544 2.31 25 Static Pressure in Inches wg 1.25 1.5 1.75 0.75 1 826 0.36 7.8 887 0.45 8.9 964 0.59 10.5 1047 0.75 12.5 1135 0.95 14.6 1223 1.18 16.9 1314 1.45 19.7 1405 1.77 21 1499 2.13 23 1593 2.55 25 969 0.58 9.9 1032 0.71 11.4 1109 0.89 13.2 1191 1.11 15.2 1279 1.36 17.6 1367 1.65 19.8 1457 1.98 21 1548 2.37 23 1640 2.80 25 1044 0.71 11.2 1102 0.86 12.5 1169 1.04 13.9 1247 1.27 15.8 1329 1.54 18.7 1417 1.85 20 1505 2.20 22 1594 2.60 24 1170 1.01 13.3 1229 1.20 14.8 1301 1.43 17.0 1379 1.72 18.4 1462 2.04 20 1550 2.42 22 1638 2.84 25 1233 1.17 14.3 1291 1.37 16.3 1352 1.60 17.9 1428 1.90 18.5 1506 2.24 20 1591 2.63 23 2 2.25 2.5 1349 1.55 17.0 1407 1.79 17.5 1475 2.08 18.8 1552 2.44 20 1631 2.85 23 1403 1.73 16.8 1461 1.99 17.8 1521 2.27 19.2 1596 2.64 21 1513 2.19 18.4 1572 2.49 19.7 1638 2.85 21 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 37 SWB-120 - Belt Drive Series 100 335⁄8 3.5 (51) 46 211⁄8 361⁄8 11⁄2 241⁄2 (537) (918) (38) (622) 3 1.5 3 1.0 0.0 0 1 1 2 2 0 5 47 3 4 5 Volume (cfm X 1000) 5 0 82 64 57 Do 70 0.5 13 2 0 Wheel Diameter = 21 ⁄8 (549) Shaft Diameter = 1 (25) Outlet Area = 2.23 ft2 (0.21 m2) ^Approximate Unit Weight = 374 lb. (170 kg) 2.0 11 27 ⁄8 (695) 4 1 35 (889) 37 (940) 3 RPM HP Density 0.075 lb/ft3 5 99 193⁄8 (492) 255⁄8 (651) 5 2.5 ½ (1168) 6 Static Pressure (in. wg) (537) ¾ Static Pressure (Pa x 100) 21 ⁄2 (546) 1 7 211⁄8 1 3 3.0 cur ve (391) yst em (603) 8 eft of this s 2 ot he l 153⁄8 no ts ele ct t (378) 233⁄4 2 147⁄8 1½ (854) 4 6 8 6 7 10 12 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/943)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/1040)3) Maximum RPM = 1357 Tip Speed (ft/min.) = RPM x 5.23 (Tip Speed (m/s) = RPM x 0.0266) SWB-120 CFM Maximum Motor Frame Size = 215T OV 1800 807 2250 1009 2700 1211 3150 1413 3600 1614 4050 1816 4500 2018 4950 2220 5400 2422 5850 2623 6300 2825 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 471 0.12 6.5 528 0.17 6.6 593 0.25 7.1 658 0.34 7.9 723 0.45 9.0 791 0.59 10.7 861 0.75 13.1 931 0.94 15.9 1003 1.16 17.6 1076 1.42 19.3 1151 1.73 21 0.5 591 0.22 6.5 633 0.29 6.7 686 0.38 7.3 743 0.49 8.3 807 0.62 10.0 873 0.79 12.3 937 0.98 14.4 1002 1.20 15.9 1069 1.45 17.8 1137 1.74 19.8 1207 2.06 21 0.75 1 728 0.42 8.0 770 0.52 8.1 820 0.64 9.1 877 0.79 10.9 937 0.97 13.0 1001 1.19 15.1 1067 1.45 16.8 1132 1.73 18.5 1196 2.04 19.3 1262 2.40 20 811 0.56 9.4 850 0.68 9.5 892 0.81 10.2 943 0.98 11.6 999 1.17 13.4 1057 1.40 15.3 1121 1.67 17.4 1186 1.98 18.5 1252 2.34 19.3 1316 2.71 21 Static Pressure in Inches wg 1.25 1.5 1.75 923 0.84 11.2 962 0.99 11.2 1006 1.17 12.4 1057 1.38 14.3 1113 1.62 16.2 1171 1.90 17.2 1234 2.23 18.1 1298 2.60 19.7 989 1.01 12.3 1028 1.18 12.4 1068 1.37 13.0 1113 1.59 15.0 1166 1.85 16.5 1222 2.15 17.0 1280 2.48 18.0 1342 2.87 20 1088 1.37 13.5 1128 1.58 13.7 1169 1.82 15.1 1217 2.09 16.4 1270 2.40 17.2 1327 2.75 18.7 2 2.25 2.5 1145 1.57 14.6 1184 1.80 14.9 1223 2.05 15.5 1267 2.33 16.7 1316 2.65 18.1 1237 2.02 16.4 1276 2.29 16.6 1316 2.58 17.8 1287 2.24 18.0 1326 2.53 18.2 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 38 8 SWB-124 - Belt Drive Series 100 405⁄8 4.0 (64) 9 3.0 311⁄2 (657) (38) (800) 5 4 3 2.0 1.5 ½ 453⁄4 11⁄2 (1162) 2.5 ¾ (1467) 6 is s 257⁄8 1 573⁄4 7 Wheel Diameter = 24 ⁄4 (629) Shaft Diameter = 1 (25) Outlet Area = 3.40 ft2 (0.32 m2) ^Approximate Unit Weight = 546 lb. (248 kg) 56 0.0 0 2 4 5 3 0 2 4 6 25 0 t no Do 4 14 60 36 (914) 411⁄2 (1054) 0.5 5 1 89 193⁄4 (502) 0 73 311⁄8 (791) 335⁄8 (854) 12 1.0 2 10 se le ct to (661) Static Pressure (in. wg) (667) Static Pressure (Pa x 100) 26 1½ 8 261⁄4 RPM HP Density 0.075 lb/ft3 3.5 cur ve (483) yst em (635) of th 21⁄2 th el eft 19 5 (451) 25 3 173⁄4 2 (1032) 6 8 Volume (cfm X 1000) 8 10 12 14 Volume (m3/hr x 1000) 10 16 12 18 20 Maximum BHP at a given RPM = (RPM/713) 3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/786)3) Maximum RPM = 1225 Tip Speed (ft/min.) = RPM x 6.41 (Tip Speed (m/s) = RPM x 0.0326) SWB-124 CFM Maximum Motor Frame Size = 256T OV 2800 824 3400 1000 4000 1176 4600 1353 5200 1529 5800 1706 6400 1882 7000 2059 7600 2235 8200 2412 8800 2588 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.25 413 0.19 4.9 464 0.27 6.0 517 0.38 7.5 572 0.51 9.1 629 0.66 11.0 687 0.86 12.9 746 1.09 14.7 806 1.37 16.5 867 1.69 18.0 927 2.07 20 989 2.50 23 0.5 0.75 1 541 0.43 6.9 588 0.56 8.3 638 0.71 9.8 691 0.91 11.6 745 1.13 13.8 800 1.38 16.4 856 1.68 17.6 913 2.03 19.0 971 2.43 21 1030 2.88 23 651 0.74 9.2 696 0.92 10.7 744 1.13 12.7 795 1.39 15.5 849 1.68 16.8 903 2.01 18.2 958 2.38 19.9 1013 2.80 22 1070 3.27 24 751 1.14 11.8 795 1.37 14.0 843 1.64 15.6 893 1.96 17.2 945 2.32 19.2 999 2.74 21 1053 3.19 23 1108 3.69 24 Static Pressure in Inches wg 1.25 1.5 1.75 843 1.62 14.4 888 1.91 15.3 935 2.24 17.3 984 2.63 19.8 1037 3.07 22 1090 3.56 24 1144 4.11 25 930 2.18 15.7 976 2.54 17.6 1024 2.94 19.9 1073 3.40 22 1125 3.92 25 1178 4.49 26 1014 2.83 18.0 1061 3.26 20 1109 3.74 22 1158 4.28 25 1210 4.87 26 2 2.25 2.5 1055 3.15 18.5 1097 3.59 20 1144 4.09 23 1192 4.64 25 1132 3.92 21 1177 4.44 23 1224 5.02 25 1170 4.26 21 1209 4.79 23 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 39 SWB-206 - Belt Drive Series 200 (219) (508) (248) 2 (51) 11 4.5 10 4.0 ½ 111⁄4 (292) (286) 265⁄8 11 (676) (279) 211⁄4 11⁄2 151⁄8 (540) (38) (384) 8 7 6 5 4 3.0 3 2.5 ¼ 2.0 1.5 Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.63 ft2 (0.06 m 2 ) ^Approximate Unit Weight = 140 lb. (64 kg) not Do 0.0 0 0 0 121 0 670 1 1 2 2 3 3 4 Volume (cfm X 100) 4 5 6 7 0 0.5 1 251⁄4 (641) 263⁄4 (679) 0 229 15 ⁄4 (400) 50 17 16 (406) 167⁄8 (429) 0 283 1.0 2 3 RPM HP Density 0.075 lb/ft3 337 3 3.5 Static Pressure (in. wg) 11 ⁄2 Static Pressure (Pa x 100) 9 1 1 ¾ system curve 93⁄4 of thi s 20 the l eft 85⁄8 sele ct to 183⁄4 (476) 5 8 6 9 10 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/3629)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/4001)3) Maximum RPM = 3370 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-206 CFM Maximum Motor Frame Size = 145T OV 70 111 120 190 170 270 220 349 270 429 320 508 370 587 420 667 470 746 520 825 570 905 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 1201 0.03 6.4 1262 0.04 6.8 1350 0.05 7.4 1489 0.07 8.0 1693 0.10 9.0 1921 0.14 10.5 2169 0.19 12.1 2422 0.26 13.7 2678 0.35 15.8 2936 0.45 18.5 3196 0.58 22 1 1.5 1.75 1722 0.09 9.2 1786 0.11 9.8 1868 0.13 10.7 1975 0.16 11.8 2138 0.20 12.9 2341 0.26 14.2 2567 0.33 15.8 2802 0.42 17.7 3051 0.53 19.3 3303 0.67 21 2079 0.16 11.9 2137 0.19 12.5 2203 0.22 13.3 2289 0.25 14.2 2395 0.28 15.2 2540 0.34 16.4 2721 0.41 18.1 2943 0.51 19.7 3170 0.62 21 2238 0.20 13.2 2292 0.23 13.8 2355 0.26 14.5 2429 0.29 15.3 2529 0.33 16.5 2643 0.39 17.6 2817 0.46 19.2 3010 0.55 21 3234 0.67 22 Static Pressure in Inches wg 2 2.5 2.75 2435 0.27 15.0 2497 0.31 15.8 2566 0.35 16.7 2659 0.39 17.8 2767 0.44 19.0 2907 0.51 20 3087 0.60 22 3296 0.72 23 2698 0.35 17.8 2760 0.40 18.6 2825 0.45 19.4 2898 0.50 20 2998 0.55 21 3108 0.62 22 3252 0.71 24 2822 0.40 19.1 2881 0.45 19.7 2945 0.51 20 3014 0.56 21 3108 0.62 22 3213 0.68 23 3330 0.77 24 3 3.5 3.75 2941 0.45 20 2997 0.51 21 3059 0.57 22 3128 0.62 22 3213 0.68 23 3313 0.74 24 3165 0.56 22 3216 0.61 23 3277 0.68 24 3343 0.75 25 3272 0.62 24 3319 0.67 24 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 40 7 11 SWB-207 - Belt Drive Series 200 183⁄4 6 (248) (51) 5 (292) (286) 26 ⁄8 5 11 (676) (279) 21 ⁄4 1 11⁄2 151⁄8 (540) (38) (384) 1 0 670 0 17 0 2 4 5 0 50 121 30 Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.63 ft2 (0.06 m 2 ) ^Approximate Unit Weight = 140 lb. (64 kg) 2 28 0 3 ¼ 70 33 4 ½ 3 90 251⁄4 (641) 263⁄4 (679) 16 ⁄8 (429) 6 2 153⁄4 (400) 7 8 4 22 16 (406) 10 ¾ Static Pressure (in. wg) 111⁄4 Static Pressure (Pa x 100) 12 111⁄2 curv e (508) RPM HP Density 0.075 lb/ft3 this syst em (219) 1 14 2 the left of 93⁄4 no ts ele ct t o 20 Do 85⁄8 1½ (476) 6 8 Volume (cfm X 100) 10 Volume (m3/hr x 100) 10 12 15 20 Maximum BHP at a given RPM = (RPM/3099)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/3417)3) Maximum RPM = 3370 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-207 CFM Maximum Motor Frame Size = 145T OV 200 317 280 444 360 571 440 698 520 825 600 952 680 1079 760 1206 840 1333 920 1460 1000 1587 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 1098 0.04 6.2 1244 0.06 7.3 1415 0.09 8.5 1591 0.13 10.0 1793 0.19 12.6 2007 0.26 16.0 2226 0.36 18.4 2449 0.47 22 2678 0.61 25 2909 0.78 28 3142 0.97 30 1 1458 0.10 9.1 1549 0.12 9.7 1687 0.16 10.7 1855 0.21 12.4 2023 0.28 15.0 2195 0.35 17.1 2395 0.45 19.5 2600 0.58 23 2815 0.73 27 3034 0.90 29 3255 1.11 32 1.5 2 1808 0.19 11.1 1923 0.23 12.1 2064 0.29 14.2 2230 0.37 16.5 2404 0.47 18.9 2565 0.57 21 2751 0.69 24 2951 0.85 27 3156 1.03 30 2060 0.27 13.3 2139 0.32 14.1 2259 0.38 15.5 2406 0.47 17.9 2574 0.57 21 2751 0.70 23 2911 0.83 26 3084 0.98 28 3282 1.17 31 Static Pressure in Inches wg 2.5 3 3.5 2333 0.40 15.7 2446 0.48 17.4 2577 0.57 19.5 2725 0.68 22 2898 0.81 25 3075 0.97 27 3235 1.13 29 2534 0.51 17.7 2618 0.58 19.1 2735 0.68 21 2878 0.80 24 3034 0.93 25 3208 1.11 28 2777 0.68 21 2893 0.79 23 3021 0.92 25 3168 1.06 26 3332 1.24 29 4 4.5 5 2941 0.80 22 3040 0.91 24 3158 1.04 26 3300 1.20 28 3103 0.94 24 3179 1.03 25 3295 1.17 27 3255 1.07 25 3311 1.16 26 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 41 SWB-208 - Belt Drive Series 200 183⁄4 6 (248) ¾ (51) 5 11 265⁄8 (279) 211⁄4 (676) 11⁄2 151⁄8 (540) (38) (384) 8 6 0 0 50 0 4 5 0 22 17 121 670 2 70 0 Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.63 ft2 (0.06 m 2 ) ^Approximate Unit Weight = 140 lb. (64 kg) 2 90 30 251⁄4 (641) 263⁄4 (679) 167⁄8 (429) 3 ¼ 1 2 153⁄4 (400) 3 33 4 ½ 4 28 16 (406) 10 Do 111⁄4 (286) Static Pressure (in. wg) 111⁄2 (292) Static Pressure (Pa x 100) 12 RPM HP Density 0.075 lb/ft3 stem curv e (508) this sy (219) 14 2 left of 93⁄4 the 20 no ts ele ct to 85⁄8 1½ (476) 6 8 10 Volume (cfm X 100) 10 15 12 14 20 25 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/3242)3 (Maximum KW at a given RPM = (RPM/3574)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 3370 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-208 CFM Maximum Motor Frame Size = 145T OV 250 397 370 587 490 778 610 968 730 1159 850 1349 970 1540 1090 1730 1210 1921 1330 2111 1450 2302 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 1125 0.04 7.0 1270 0.06 7.7 1445 0.09 8.6 1640 0.12 9.2 1852 0.18 11.2 2076 0.24 13.5 2310 0.33 15.3 2548 0.44 17.5 2790 0.57 19.9 3035 0.73 22 3282 0.91 26 0.75 1343 0.06 8.0 1451 0.09 8.3 1606 0.12 9.1 1785 0.16 10.5 1980 0.22 12.4 2189 0.29 14.1 2409 0.38 16.0 2637 0.50 18.1 2872 0.63 21 3111 0.80 23 3352 0.99 25 1 1.5 1610 0.11 8.8 1753 0.16 9.7 1918 0.21 11.3 2101 0.27 12.9 2298 0.34 14.6 2507 0.44 16.6 2725 0.56 18.8 2951 0.70 21 3184 0.87 24 1909 0.18 10.9 2014 0.23 11.4 2160 0.29 12.5 2323 0.37 13.8 2505 0.45 15.6 2697 0.56 17.7 2896 0.69 20 3110 0.84 22 3329 1.02 25 Static Pressure in Inches wg 2 2.5 3 2172 0.26 13.2 2240 0.30 13.1 2378 0.38 14.4 2528 0.47 14.8 2693 0.57 16.5 2874 0.69 18.6 3065 0.82 21 3263 0.98 23 2472 0.39 15.3 2575 0.47 16.2 2715 0.57 17.8 2871 0.69 17.6 3041 0.82 19.5 3222 0.97 21 2681 0.49 17.6 2755 0.56 18.1 2892 0.68 19.9 3039 0.81 18.6 3198 0.95 20 3.5 4 4.5 2874 0.59 19.9 2941 0.67 21 3056 0.79 22 3196 0.93 22 3350 1.09 21 3121 0.79 22 3210 0.90 22 3348 1.06 23 3289 0.91 23 3357 1.01 23 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 42 16 SWB-210 - Belt Drive Series 200 183⁄4 6 (51) 265⁄8 11 (676) (279) 211⁄4 11⁄2 151⁄8 (540) (38) 6 3 ¼ 2 17 70 12 35 251⁄4 (641) 263⁄4 (679) 0 0 1 05 2 153⁄4 (400) 3 40 28 4 ½ 23 16 (406) 167⁄8 (429) 8 4 337 (384) 10 Static Pressure (in. wg) 111⁄4 (286) Static Pressure (Pa x 100) 11 ⁄2 (292) ¾ 5 12 1 RPM HP Density 0.075 lb/ft3 2 cur ve (248) to the lef to f th is s yst em (508) 14 2 no ts ele ct 93⁄4 Do (219) 20 1½ 85⁄8 1 (476) 700 0 0 3 6 9 12 15 18 21 24 27 Volume (cfm X 100) Wheel Diameter = 113⁄8 (289) Shaft Diameter = 3/4 (19) Outlet Area = 0.63 ft2 (0.06 m2) ^Approximate Unit Weight = 140 lb. (64 kg) 0 10 20 30 40 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/2649)3 (Maximum KW at a given RPM = (RPM/2921)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 3370 Tip Speed (ft/min.) = RPM x 2.91 (Tip Speed (m/s) = RPM x 0.0148) SWB-210 CFM Maximum Motor Frame Size = 145T OV 625 992 800 1270 975 1548 1150 1825 1325 2103 1500 2381 1675 2659 1850 2937 2025 3214 2200 3492 2375 3770 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 1158 0.08 6.3 1311 0.12 7.4 1480 0.17 8.6 1661 0.24 10.0 1853 0.32 11.9 2054 0.43 14.0 2258 0.56 16.5 2465 0.72 18.3 2674 0.91 20 2885 1.13 22 3096 1.39 25 1 1501 0.17 7.6 1583 0.21 8.2 1714 0.27 9.5 1872 0.35 11.0 2041 0.45 12.9 2214 0.57 15.1 2402 0.71 17.0 2594 0.89 18.7 2793 1.09 21 2996 1.33 23 3201 1.60 25 1.5 1809 0.27 9.4 1846 0.31 9.8 1936 0.38 10.7 2063 0.47 12.3 2214 0.58 14.3 2381 0.72 16.0 2550 0.88 17.6 2724 1.06 19.3 2913 1.28 21 3104 1.53 24 3300 1.82 26 2 2106 0.44 11.9 2143 0.50 12.4 2250 0.60 13.9 2379 0.72 15.2 2528 0.87 16.6 2694 1.05 18.3 2863 1.25 20 3034 1.47 22 3214 1.73 24 Static Pressure in Inches wg 2.5 3 3.5 2334 0.58 13.9 2371 0.65 14.3 2431 0.74 14.8 2541 0.87 15.9 2676 1.03 17.3 2825 1.21 19.0 2990 1.43 21 3159 1.68 23 3329 1.95 25 2578 0.81 15.4 2615 0.90 15.8 2704 1.03 16.7 2815 1.20 18.1 2958 1.39 19.7 3108 1.61 21 3274 1.88 23 2768 0.97 16.6 2805 1.07 17.1 2854 1.19 17.6 2964 1.37 18.8 3082 1.58 20 3229 1.81 22 4 4.5 5 2982 1.26 18.3 3019 1.38 18.8 3103 1.55 19.6 3214 1.77 21 3345 2.01 23 3148 1.45 19.5 3185 1.58 20 3235 1.73 21 3344 1.96 22 3305 1.65 21 3342 1.79 21 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 43 SWB-212 - Belt Drive Series 200 213⁄8 6 2 (394) (244) (51) 14 5 12 151⁄8 (38) 0 0 Wheel Diameter = 12 ⁄2 (318) Shaft Diameter = 1 (25) Outlet Area = 0.85 ft2 (0.08 m 2 ) ^Approximate Unit Weight = 170 lb. (77 kg) 700 5 25 0 10 15 20 Volume (cfm X 100) 1 0 10 2 0 229⁄10 (582) 17 121 55 27 21 ⁄8 (543) 3 40 1 2 12 (305) ¼ 22 16 (406) 167⁄8 (429) 4 3 2 326 (384) 6 ft o f (330) (565) the le 11⁄2 ½ 3 sel ect to (721) 8 4 no t 13 221⁄4 10 Do 28 ⁄8 3 Static Pressure (in. wg) 13 (330) Static Pressure (Pa x 100) ¾ 131⁄4 (337) RPM HP Density 0.075 lb/ft3 this syst em c urve 95⁄8 2 (248) 151⁄2 1½ 93⁄4 1 (543) 20 30 25 30 40 50 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/2372)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/2615)3) Maximum RPM = 3262 Tip Speed (ft/min.) = RPM x 3.21 (Tip Speed (m/s) = RPM x 0.0163) SWB-212 CFM Maximum Motor Frame Size = 145T OV 600 706 850 1000 1100 1294 1350 1588 1600 1882 1850 2176 2100 2471 2350 2765 2600 3059 2850 3353 3100 3647 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 1022 0.08 6.0 1150 0.11 7.2 1325 0.17 8.7 1522 0.25 10.5 1732 0.36 12.8 1947 0.50 15.6 2177 0.69 18.4 2409 0.92 21 2641 1.20 23 2874 1.53 27 3108 1.91 30 1 1372 0.16 7.9 1447 0.21 8.5 1561 0.28 9.8 1728 0.38 11.7 1905 0.51 14.0 2104 0.66 16.8 2312 0.86 19.0 2524 1.10 21 2739 1.39 24 2968 1.75 27 3199 2.17 31 1.5 2 1710 0.33 10.4 1799 0.42 11.4 1913 0.52 13.2 2080 0.67 15.7 2255 0.84 17.6 2443 1.05 19.7 2646 1.31 22 2855 1.62 25 3067 1.98 28 1941 0.45 12.7 2005 0.56 13.6 2113 0.68 14.9 2233 0.84 16.5 2403 1.03 18.4 2578 1.26 21 2761 1.53 23 2962 1.85 26 3169 2.23 29 Static Pressure in Inches wg 2.5 3 3.5 2208 0.71 15.2 2291 0.85 16.0 2404 1.02 17.4 2538 1.22 19.2 2708 1.47 21 2883 1.76 24 3065 2.10 27 2392 0.87 16.5 2457 1.03 17.2 2564 1.21 18.4 2679 1.43 20 2830 1.69 22 3001 2.00 25 2562 1.03 17.8 2625 1.21 18.5 2712 1.41 19.5 2825 1.65 21 2944 1.91 23 3112 2.24 26 4 4.5 5 2719 1.20 19.0 2783 1.40 19.8 2851 1.62 21 2962 1.87 22 3076 2.16 24 2931 1.59 21 2995 1.83 22 3091 2.10 23 3071 1.79 23 3135 2.05 23 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 44 35 SWB-213 - Belt Drive Series 200 233⁄8 6 (51) (362) 311⁄4 14 (794) (356) 243⁄4 11⁄2 165⁄8 (629) (38) (422) 10 3 2 ¼ 5 0 11 40 10 15 20 2 0 290 0 Do 700 60 1 24 Wheel Diameter = 133⁄4 (349) Shaft Diameter = 1 (25) Outlet Area = 1.03 ft2 (0.10 m 2 ) ^Approximate Unit Weight = 183 lb. (83 kg) 3 20 20 0 4 80 18 ⁄8 (479) 4 5 15 271⁄2 (699) 301⁄8 (765) 7 6 2 13 (330) 175⁄8 (448) 8 Static Pressure (in. wg) 141⁄4 145⁄8 (371) Static Pressure (Pa x 100) 12 RPM HP Density 0.075 lb/ft3 lef to f th is s yst em cur ve (270) 3 no ts ele ct to the (552) 2 2 (270) 14 ½ 105⁄8 ¾ 213⁄4 1 105⁄8 1½ (594) 20 25 30 Volume (cfm X 100) 35 40 60 40 45 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/2002)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor (Maximum KW at a given RPM = (RPM/2207)3) Maximum RPM = 2902 Tip Speed (ft/min.) = RPM x 3.53 (Tip Speed (m/s) = RPM x 0.0179) SWB-213 CFM Maximum Motor Frame Size = 184T OV 1000 971 1280 1243 1560 1515 1840 1786 2120 2058 2400 2330 2680 2602 2960 2874 3240 3146 3520 3417 3800 3689 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 998 0.12 6.9 1134 0.18 8.2 1290 0.26 9.6 1457 0.37 11.5 1629 0.51 13.7 1807 0.68 16.4 1987 0.89 18.8 2170 1.14 21 2355 1.44 23 2541 1.79 26 2729 2.19 29 0.75 1144 0.18 7.5 1248 0.24 8.7 1384 0.33 10.2 1540 0.45 12.0 1703 0.59 14.2 1874 0.78 17.0 2048 1.01 19.0 2226 1.27 21 2407 1.58 23 2589 1.94 26 2773 2.36 30 1 1287 0.24 8.4 1358 0.31 9.2 1478 0.40 10.8 1619 0.53 12.6 1775 0.69 15.0 1938 0.88 17.3 2107 1.12 19.3 2280 1.40 21 2457 1.72 24 2636 2.10 27 2817 2.53 30 Static Pressure in Inches wg 1.5 2 2.5 3 1585 0.46 11.0 1660 0.56 12.2 1778 0.70 14.1 1913 0.87 16.3 2063 1.09 18.1 2222 1.34 20 2386 1.64 22 2555 1.99 25 2727 2.40 27 1850 0.74 14.2 1931 0.89 15.5 2051 1.08 17.1 2184 1.30 18.8 2332 1.58 21 2489 1.89 23 2650 2.26 25 2816 2.68 28 2034 0.95 15.8 2093 1.10 16.5 2181 1.29 17.9 2307 1.53 19.7 2440 1.81 22 2587 2.16 24 2744 2.54 26 2249 1.32 17.7 2318 1.52 18.8 2423 1.78 20 2550 2.07 22 2685 2.42 25 2832 2.83 27 3.5 4 4.5 2462 1.77 19.8 2543 2.03 21 2656 2.34 23 2784 2.69 26 2596 2.03 21 2665 2.29 22 2758 2.62 24 2884 2.99 27 2730 2.31 23 2790 2.58 24 2869 2.90 25 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 45 SWB-215 - Belt Drive Series 200 253⁄4 6 (296) 2 (546) (295) (51) 14 5 12 (38) 4 left of 27 4 260 18 00 9 22 00 600 0 0 00 0 18 10 27 ⁄8 (689) 311⁄4 (794) 1 211⁄8 (537) the ¼ 1 2 15 (381) 2 00 14 20 (508) 6 3 (470) 3 se lec t to 181⁄2 (699) ½ 11⁄2 8 no t (403) 271⁄2 4 Do (883) 10 Static Pressure (in. wg) 15 ⁄8 7 ¾ 343⁄4 Static Pressure (Pa x 100) 153⁄4 (400) 1 161⁄4 (413) RPM HP Density 0.075 lb/ft3 this sys tem cur ve 115⁄8 3 211⁄2 2 115⁄8 1½ (654) 36 45 54 Volume (cfm X 100) Wheel Diameter = 151⁄4 (387) Shaft Diameter = 1 (25) Outlet Area = 1.25 ft2 (0.12 m 2 ) ^Approximate Unit Weight = 231 lb. (105 kg) 0 20 40 60 80 Volume (m3/hr x 100) Maximum BHP at a given RPM = (RPM/1679)3 (Maximum KW at a given RPM = (RPM/1851)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2604 Tip Speed (ft/min.) = RPM x 3.93 (Tip Speed (m/s) = RPM x 0.0200) SWB-215 CFM Maximum Motor Frame Size = 184T OV 1200 960 1550 1240 1900 1520 2250 1800 2600 2080 2950 2360 3300 2640 3650 2920 4000 3200 4350 3480 4700 3760 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 886 0.15 6.9 1009 0.22 8.2 1150 0.32 9.7 1301 0.45 11.5 1458 0.62 13.8 1620 0.83 16.5 1785 1.09 19.0 1951 1.41 21 2120 1.78 24 2290 2.21 26 2460 2.72 30 0.75 1024 0.21 7.5 1112 0.29 8.7 1236 0.40 10.2 1377 0.54 12.1 1525 0.72 14.3 1680 0.96 17.0 1839 1.23 19.2 2001 1.56 21 2166 1.95 24 2332 2.41 27 2500 2.93 30 1 1157 0.29 8.5 1214 0.37 9.3 1322 0.49 10.8 1449 0.64 12.7 1591 0.84 15.0 1738 1.08 17.4 1893 1.37 19.4 2050 1.72 22 2211 2.13 24 2374 2.60 27 1.5 Static Pressure in Inches wg 2 2.5 3 1421 0.56 11.2 1487 0.68 12.3 1593 0.85 14.2 1715 1.07 16.3 1852 1.33 18.2 1996 1.65 20 2145 2.02 22 2299 2.46 25 2456 2.97 28 1661 0.91 14.4 1732 1.09 15.6 1840 1.32 17.2 1961 1.59 19.0 2095 1.94 21 2238 2.33 23 2385 2.79 26 1830 1.16 15.9 1879 1.34 16.6 1958 1.58 18.0 2072 1.88 19.8 2193 2.23 22 2326 2.66 24 2020 1.61 17.9 2083 1.86 19.0 2176 2.18 21 2293 2.54 23 2416 2.98 25 3.5 4 4.5 2165 1.92 19.3 2213 2.17 20 2285 2.49 22 2388 2.88 24 2333 2.48 21 2396 2.81 23 2456 2.83 23 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 46 SWB-216 - Belt Drive Series 200 28 6 1 ⁄2 203⁄8 (762) (38) 95 5 600 0 1 0 2 2 3 4 Volume (cfm X 1000) 4 8 Wheel Diameter = 163⁄4 (425) Shaft Diameter = 11⁄4 (32) Outlet Area = 1.52 ft2 (0.14 m 2 ) ^Approximate Unit Weight = 251 lb. (114 kg) 0 65 0 10 301⁄4 (769) 323⁄8 (823) 16 1 20 20 3 2 16 (406) ¼ 237 4 ½ 2 13 213⁄8 (543) 227⁄8 (581) 6 3 D (518) 8 no t (445) 30 1 4 ¾ (968) 10 o 17 ⁄2 1 Static Pressure (in. wg) 38 ⁄8 1 Static Pressure (Pa x 100) 17 ⁄2 (445) 1 17 ⁄4 (451) 1 1½ 5 12 3 RPM HP Density 0.075 lb/ft3 curv e (51) this sys tem (324) left of (546) 14 the (318) 2 se lec t to 123⁄4 5 211⁄2 3 121⁄2 2 (711) 6 5 8 6 7 10 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/1414)3 (Maximum KW at a given RPM = (RPM/1559)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2378 Tip Speed (ft/min.) = RPM x 4.32 (Tip Speed (m/s) = RPM x 0.0219) SWB-216 CFM Maximum Motor Frame Size = 184T OV 1200 789 1650 1086 2100 1382 2550 1678 3000 1974 3450 2270 3900 2566 4350 2862 4800 3158 5250 3454 5700 3750 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 762 0.15 5.9 848 0.22 7.1 970 0.32 8.5 1109 0.46 10.1 1256 0.65 12.2 1410 0.90 14.6 1566 1.21 17.5 1724 1.59 19.7 1884 2.05 22 2046 2.60 25 2208 3.25 28 0.75 900 0.22 6.9 959 0.31 7.6 1059 0.42 9.0 1182 0.58 10.6 1320 0.79 12.7 1462 1.04 15.1 1616 1.37 17.6 1770 1.78 19.9 1926 2.25 22 2084 2.81 25 2244 3.47 29 1 1.5 1072 0.40 8.4 1147 0.53 9.6 1255 0.70 11.2 1381 0.92 13.3 1520 1.20 15.7 1661 1.53 17.9 1813 1.95 20 1967 2.45 23 2123 3.04 25 2279 3.71 29 1267 0.61 10.4 1322 0.77 11.1 1400 0.96 12.7 1505 1.20 14.7 1626 1.51 16.6 1758 1.89 18.5 1900 2.34 21 2042 2.85 23 2194 3.46 26 2348 4.19 30 Static Pressure in Inches wg 2 2.5 3 1487 1.03 13.3 1543 1.25 14.4 1629 1.52 15.7 1734 1.84 17.4 1853 2.24 19.3 1985 2.73 21 2124 3.29 24 2265 3.92 27 1632 1.30 14.8 1687 1.56 15.6 1749 1.85 16.6 1841 2.20 18.3 1950 2.61 20 2069 3.11 22 2200 3.72 25 2338 4.41 28 1818 1.88 16.8 1874 2.20 17.6 1949 2.57 19.2 2042 3.01 21 2156 3.53 23 2277 4.14 26 3.5 4 4.5 1939 2.21 18.1 1994 2.57 18.9 2050 2.96 20 2141 3.43 22 2239 3.97 24 2355 4.60 27 2106 2.94 20 2162 3.38 21 2234 3.86 23 2326 4.43 25 2211 3.33 21 2267 3.80 22 2324 4.30 24 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 47 SWB-218 - Belt Drive Series 200 307⁄8 6 (359) (51) 5 19 ⁄4 331⁄4 (1067) 11⁄2 223⁄8 (489) (845) (38) (568) 8 6 4 1 3 2 ¾ ½ 7 0 2 30 87 18 1 10 D 555 15 0 0 90 0 214 3 ¼ 11 321⁄4 (819) 34 (864) 4 1 2 177⁄8 (454) 233⁄8 (594) 25 (635) 10 o 42 1 Static Pressure (in. wg) 193⁄8 (492) 1½ 195⁄8 Static Pressure (Pa x 100) 12 (498) RPM HP Density 0.075 lb/ft3 this sys tem curv e 2 (559) to the left of (349) 14 no ts ele ct 141⁄8 5 22 2 133⁄4 3 (784) 3 4 5 Volume (cfm X 1000) 6 7 Wheel Diameter = 185⁄8 (473) Shaft Diameter = 11⁄4 (32) Outlet Area = 1.87 ft2 (0.17 m2 ) ^Approximate Unit Weight = 324 lb. (147 kg) Maximum BHP at a given RPM = (RPM/1196)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 2147 Tip Speed (ft/min.) = RPM x 4.78 0 2 4 6 8 10 12 Volume (m3/hr x 1000) (Maximum KW at a given RPM = (RPM/1319)3) (Tip Speed (m/s) = RPM x 0.0243) SWB-218 CFM Maximum Motor Frame Size = 213T OV 2000 1070 2500 1337 3000 1604 3500 1872 4000 2139 4500 2406 5000 2764 5500 2941 6000 3209 6500 3476 7000 3743 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 762 0.26 10.1 862 0.37 10.1 974 0.52 11.5 1092 0.72 13.6 1218 0.97 15.7 1346 1.28 18.2 1475 1.66 21 1605 2.10 24 1737 2.63 27 1869 3.26 31 2003 3.98 34 1 963 0.49 11.3 1023 0.62 11.6 1110 0.80 12.6 1211 1.03 14.2 1322 1.32 16.4 1438 1.66 18.8 1557 2.08 21 1683 2.58 24 1810 3.15 28 1938 3.81 31 2067 4.57 35 1.5 1136 0.75 13.4 1185 0.92 13.0 1245 1.12 13.9 1327 1.36 15.2 1423 1.68 17.3 1530 2.07 19.6 1643 2.52 22 1758 3.04 25 1877 3.65 28 2002 4.37 31 2128 5.18 35 2 1330 1.24 15.2 1380 1.47 15.5 1443 1.74 16.8 1525 2.07 18.7 1619 2.48 21 1723 2.97 24 1834 3.54 26 1949 4.18 29 2065 4.91 32 Static Pressure in Inches wg 2.5 3 3.5 1459 1.58 17.9 1507 1.85 18.3 1557 2.15 19.1 1626 2.51 21 1709 2.92 23 1804 3.43 25 1907 4.03 27 2017 4.72 30 2131 5.49 33 1623 2.24 21 1672 2.58 22 1727 2.95 23 1800 3.41 24 1885 3.91 26 1981 4.54 28 2084 5.25 31 1730 2.65 24 1779 3.02 25 1828 3.43 25 1890 3.90 26 1967 4.45 28 2055 5.07 30 4 4.5 5 1878 3.48 27 1927 3.93 27 1979 4.42 28 2048 5.00 29 1971 3.95 29 2020 4.44 29 2069 4.96 30 2060 4.43 31 2108 4.96 32 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 48 8 SWB-220 - Belt Drive Series 200 335⁄8 6 5 21 ⁄8 1 (1168) 11⁄2 24 ⁄2 1 (537) (918) (38) 4 ½ 0 5 2 0 2 4 6 Volume (cfm X 1000) 4 6 8 10 1 79 507 65 Wheel Diameter = 203⁄8 (518) Shaft Diameter = 11⁄4 (32) Outlet Area = 2.23 ft2 (0.21 m2 ) ^Approximate Unit Weight = 389 lb. (176 kg) 0 75 0 13 35 (889) 37 (940) 16 ¼ 1 196 3 2 193⁄8 (492) ¾ 2 85 10 255⁄8 (651) 273⁄8 (695) 6 3 D (622) 8 4 1 361⁄8 10 Static Pressure (in. wg) 46 Static Pressure (Pa x 100) 211⁄8 (537) 1½ 21 ⁄2 (546) 2 12 1 sys tem curv e (51) this (390) RPM HP Density 0.075 lb/ft3 the left of (603) 7½ se lec t to (378) 14 2 no t 153⁄8 o 233⁄4 5 147⁄8 3 (854) 8 12 14 10 16 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/1027)3 (Maximum KW at a given RPM = (RPM/1132)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 1961 Tip Speed (ft/min.) = RPM x 5.23 (Tip Speed (m/s) = RPM x 0.0266) SWB-220 CFM Maximum Motor Frame Size = 215T OV 2000 897 2650 1188 3300 1480 3950 1771 4600 2063 5250 2354 5900 2646 6550 2937 7200 3229 7850 3520 8500 3812 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 647 0.25 8.7 731 0.36 9.2 836 0.53 10.6 951 0.76 13.0 1072 1.06 15.2 1198 1.44 17.8 1325 1.90 21 1453 2.47 24 1583 3.15 28 1714 3.97 31 1846 4.92 36 1 860 0.51 11.5 897 0.65 11.2 970 0.85 12.1 1064 1.11 13.7 1171 1.46 15.8 1285 1.88 18.4 1401 2.40 21 1525 3.04 25 1650 3.78 28 1776 4.64 32 1904 5.63 36 1.5 2 1065 1.00 13.4 1104 1.21 13.5 1177 1.51 14.9 1267 1.88 16.8 1370 2.35 19.4 1481 2.92 22 1594 3.59 25 1711 4.37 28 1835 5.32 32 1960 6.38 37 1206 1.39 15.9 1243 1.64 15.8 1289 1.94 16.4 1364 2.35 18.4 1454 2.84 21 1555 3.45 24 1664 4.18 26 1777 5.01 29 1892 5.96 33 Static Pressure in Inches wg 2.5 3 3.5 1367 2.10 19.0 1405 2.43 19.4 1461 2.85 21 1539 3.37 23 1630 4.00 25 1731 4.76 27 1840 5.66 30 1952 6.67 34 1480 2.58 22 1517 2.96 23 1556 3.38 23 1624 3.94 25 1706 4.58 26 1799 5.37 29 1900 6.30 32 1621 3.51 26 1658 3.98 26 1708 4.52 26 1781 5.23 28 1867 6.01 30 4 4.5 4.75 1717 4.08 28 1754 4.60 28 1792 5.15 28 1857 5.87 30 1935 6.70 32 1807 4.67 30 1845 5.23 31 1882 5.83 31 1932 6.52 32 1851 4.97 32 1888 5.55 32 1925 6.18 32 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 49 SWB-222 - Belt Drive Series 200 367⁄8 6 5 (584) 411⁄2 11⁄2 (1054) (38) (730) 4 0 2 0 4 8 0 5 74 477 70 0 179 ¼ 153 1 12 0 Wheel Diameter = 225⁄8 (575) Shaft Diameter = 11⁄4 (32) Outlet Area = 2.74 ft2 (0.25 m2 ) ^Approximate Unit Weight = 450 lb. (204 kg) ½ 05 341⁄8 (867) 395⁄8 (1006) ¾ 2 3 2 20 (508) 3 10 28 ⁄4 (718) 301⁄2 (775) 1 6 4 Do 283⁄4 8 Static Pressure (in. wg) 23 521⁄2 (1334) 10 1 Static Pressure (Pa x 100) 231⁄2 (597) 1½ 233⁄4 2 12 (603) curv e (64) RPM HP Density 0.075 lb/ft3 this syst em (432) left of (610) the 2 ⁄2 (413) 14 1 no ts ele ct to 17 7½ 24 5 161⁄4 3 (937) 6 8 Volume (cfm X 1000) 5 10 10 15 20 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/897)3 (Maximum KW at a given RPM = (RPM/989)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 1798 Tip Speed (ft/min.) = RPM x 5.82 (Tip Speed (m/s) = RPM x 0.0296) SWB-222 CFM Maximum Motor Frame Size = 215T OV 2500 912 3250 1186 4000 1460 4750 1734 5500 2007 6250 2281 7000 2555 7750 2828 8500 3102 9250 3376 10000 3650 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 602 0.30 9.3 677 0.43 9.7 768 0.61 11.2 868 0.86 13.6 976 1.18 15.8 1085 1.60 18.4 1197 2.10 21 1310 2.71 25 1424 3.43 29 1539 4.28 32 1655 5.28 36 1 783 0.59 11.5 831 0.77 11.5 892 0.99 12.6 975 1.27 14.2 1065 1.64 16.5 1164 2.09 19.0 1267 2.66 22 1376 3.32 25 1485 4.12 29 1596 5.04 32 1708 6.10 37 1.5 949 0.93 14.3 971 1.15 13.8 1019 1.43 14.3 1080 1.75 15.6 1158 2.14 17.5 1244 2.64 20 1339 3.23 23 1439 3.95 26 1542 4.80 29 1650 5.77 33 1760 6.87 37 2 1099 1.56 16.6 1137 1.88 16.8 1186 2.27 17.7 1249 2.70 19.5 1326 3.22 22 1410 3.85 25 1503 4.61 27 1601 5.47 30 1703 6.51 34 Static Pressure in Inches wg 2.5 3 3.5 1226 2.01 20 1241 2.36 20 1289 2.80 21 1339 3.30 22 1405 3.85 24 1484 4.52 26 1568 5.30 28 1659 6.22 31 1756 7.25 35 1347 2.88 24 1383 3.36 24 1432 3.91 25 1487 4.53 26 1553 5.20 27 1635 6.03 30 1719 6.98 32 1452 3.42 27 1470 3.92 27 1518 4.54 27 1567 5.22 28 1628 5.95 29 1698 6.78 31 1780 7.78 34 4 4.5 5 1556 4.52 29 1598 5.18 30 1647 5.92 30 1698 6.73 31 1764 7.59 33 1648 5.16 32 1674 5.84 32 1722 6.63 33 1771 7.50 34 1735 5.82 35 1746 6.51 35 1793 7.36 35 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 50 12 SWB-224 - Belt Drive Series 200 405⁄8 6 (635) (483) (64) 3 5 257⁄8 453⁄4 (657) 11⁄2 (1162) (38) 311⁄2 (800) 3 1 ½ 65 5 424 0 411⁄2 (1054) Wheel Diameter = 243⁄4 (629) Shaft Diameter = 11⁄2 (38) Outlet Area = 3.40 ft2 (0.32 m 2 ) ^Approximate Unit Weight = 568 lb. (258 kg) 0 0 2 0 4 5 6 8 Volume (cfm X 1000) 10 10 15 88 3 15 1 60 13 ¾ 25 11 2 D 36 (914) 33 ⁄8 (854) 4 2 193⁄4 (502) 5 6 0 89 315⁄8 (803) 8 4 1½ 573⁄4 (1467) 10 Static Pressure (in. wg) (660) 2 26 261⁄4 Static Pressure (Pa x 100) 12 (667) RPM HP Density 0.075 lb/ft3 to the left of t his sys tem cur ve (451) 2 ⁄2 14 1 no ts ele ct 19 o 25 7½ 173⁄4 5 (1032) 12 14 20 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/749)3 (Maximum KW at a given RPM = (RPM/826)3) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown is largest cataloged Open Drip Proof motor Maximum RPM = 1588 Tip Speed (ft/min.) = RPM x 6.41 (Tip Speed (m/s) = RPM x 0.0326) SWB-224 CFM Maximum Motor Frame Size = 256T OV 3000 882 3900 1147 4800 1412 5700 1676 6600 1941 7500 2206 8400 2471 9300 2735 10200 3000 11100 3265 12000 3529 RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones RPM BHP Sones 0.5 526 0.34 7.4 594 0.50 8.5 674 0.71 10.0 760 1.00 12.4 851 1.36 14.5 946 1.82 17.1 1041 2.38 20 1139 3.07 24 1239 3.89 28 1339 4.85 31 1440 5.98 34 0.75 614 0.51 9.1 659 0.68 9.4 729 0.92 11.0 809 1.24 13.0 894 1.64 15.2 982 2.13 17.8 1076 2.73 21 1170 3.44 25 1266 4.29 29 1364 5.28 32 1463 6.43 35 1 699 0.71 12.7 726 0.89 10.4 783 1.14 11.7 856 1.49 13.5 936 1.92 15.8 1020 2.44 18.6 1108 3.08 22 1200 3.83 25 1294 4.71 29 1390 5.73 32 1486 6.90 35 1.5 861 1.37 14.5 890 1.64 13.2 945 2.01 14.7 1015 2.49 17.0 1093 3.09 19.7 1175 3.79 23 1261 4.60 27 1348 5.55 30 1440 6.65 32 1534 7.89 36 Static Pressure in Inches wg 2 2.5 3 1001 2.20 16.1 1036 2.60 16.5 1093 3.11 18.2 1162 3.74 21 1240 4.51 24 1320 5.39 27 1404 6.41 30 1490 7.57 33 1106 2.84 18.9 1126 3.22 19.1 1171 3.77 20 1230 4.45 22 1301 5.24 25 1378 6.20 27 1458 7.28 30 1221 3.95 22 1251 4.49 23 1300 5.19 24 1362 6.03 25 1433 7.01 28 1510 8.16 31 3.5 4 4.5 1309 4.72 25 1329 5.24 25 1369 5.98 26 1423 6.85 26 1489 7.87 28 1411 6.10 27 1438 6.80 27 1484 7.69 28 1487 6.98 29 1508 7.65 29 Performance certified is for installation Type B - Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The AMCA Certified Ratings Seal applies to air performance only. 51 SWB-327 - Belt Drive Series 300 461⁄4 7 (762) (545) (106) 16 281⁄2 (724) sys tem this to the left of 1 ¾ 2 4 2 48 ⁄4 (1226) 527⁄16 (1332) 3 1 0 Wheel Diameter = 27 (686) Shaft Diameter = 111⁄16 (43) Outlet Area = 4.19 ft2 (0.389 m 2 ) ^Approximate Unit Weight = 917 lb. (417 kg) 7 72 92 6 0 57 29 1 D 1 353⁄4 (908) 0 0 0 10 2 4 5 6 31 33 (838) 6 12 (838) 8 13 (89) 4 25 14 5 5 31⁄2 (1292) 33 10 no ts ele ct (813) 1½ 32 507⁄8 5 2 613⁄4 (1568) 12 o (727) Static Pressure (in. wg) (730) 3 285⁄8 Static Pressure (Pa x 100) 14 283⁄4 RPM HP Density 0.075 lb/ft3 6 curv e 43⁄16 15 217⁄16 10 (540) 30 7½ 211⁄4 5 (1175) 76 90 7 8 10 12 Volume (cfm X 1000) 10 15 14 20 16 25 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/629)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/693)3) Maximum RPM = 1425 Tip Speed (ft/min.) = RPM x 7.07 (Tip Speed (m/s) = RPM x 0.0359) Maximum Motor Frame Size = 256T SWB-327 CFM OV 5000 1193 5900 1408 6800 1622 7700 1837 8600 2052 9500 2267 10400 2482 11300 2696 12200 2911 13100 3126 14000 3341 52 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 1 551 663 0.66 1.10 10.3 / 72 11.8 / 75 604 712 0.89 1.40 11.5 / 74 12.9 / 76 666 764 1.17 1.75 12.9 / 76 14 / 77 731 815 1.53 2.17 14.5 / 78 15.2 / 79 801 872 1.97 2.65 16.3 / 80 17 / 80 871 934 2.51 3.23 18.5 / 82 19.2 / 82 942 997 3.14 3.90 21 / 84 22 / 84 1014 1066 3.89 4.70 24 / 86 24 / 86 1086 1135 4.74 5.62 27 / 88 28 / 88 1160 1205 5.72 6.67 30 / 90 32 / 91 1233 1276 6.83 7.85 35 / 92 37 / 93 1.5 756 1.57 13.2 / 77 800 1.92 14.1 / 78 849 2.34 15.2 / 79 900 2.83 16.6 / 80 951 3.40 18.3 / 81 1003 4.03 20 / 83 1059 4.76 22 / 85 1121 5.59 25 / 87 1184 6.54 29 / 89 1249 7.62 33 / 91 1317 8.87 38 / 94 Static Pressure in Inches wg 2 2.5 3 3.5 841 2.08 14.9 / 79 878 953 1022 2.48 3.07 3.69 15.6 / 79 17.6 / 81 19.6 / 83 923 991 1058 1120 2.95 3.59 4.26 4.96 16.6 / 80 18.2 / 82 19.9 / 83 22 / 85 971 1037 1098 1157 3.50 4.19 4.91 5.65 18.1 / 81 19.4 / 83 21 / 84 22 / 85 1022 1085 1145 1201 4.14 4.88 5.66 6.45 19.7 / 83 21 / 84 22 / 85 24 / 86 1074 1136 1194 1248 4.86 5.67 6.50 7.35 21 / 84 23 / 85 25 / 87 26 / 88 1125 1188 1244 1297 5.66 6.56 7.45 8.35 24 / 86 26 / 87 27 / 88 29 / 89 1177 1239 1296 1348 6.55 7.53 8.51 9.47 27 / 88 28 / 89 31 / 90 32 / 91 1236 1291 1347 1400 7.55 8.60 9.66 10.7 30 / 90 32 / 91 34 / 92 35 / 92 1298 1345 1399 8.68 9.78 10.9 35 / 92 36 / 93 37 / 93 1361 1407 9.94 11.1 39 / 94 40 / 94 4 4.5 5 1179 5.67 24 / 86 1215 6.43 24 / 86 1253 7.26 25 / 87 1299 8.21 28 / 89 1347 9.27 31 / 90 1397 10.5 33 / 91 1234 6.40 26 / 88 1270 7.22 26 / 88 1307 8.11 27 / 88 1348 9.10 29 / 89 1395 10.2 32 / 91 1322 8.02 28 / 89 1358 8.97 29 / 89 1395 10.0 30 / 90 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 18 30 SWB-327-AF - Belt Drive Series 300 461⁄4 6 (545) (106) 32 (1568) 507⁄8 (89) 48 ⁄4 (1226) 1 Do n 1 353⁄4 (908) 0 527⁄16 (1332) Wheel Diameter = 27 (686) Shaft Diameter = 111⁄16 (43) Outlet Area = 4.19 ft2 (0.389 m 2 ) ^Approximate Unit Weight = 877 lb. (399 kg) 0 0 2 0 6 61 71 0 4 5 76 5 84 2 281⁄2 (724) ¾ 13 4 1 2 8 96 33 (838) 6 3 1½ 47 11 (838) 2 13 33 (813) (1292) 8 4 50 14 31⁄2 10 Static Pressure (in. wg) 613⁄4 Static Pressure (Pa x 100) 28 ⁄8 (727) 3 28 ⁄4 (730) RPM HP Density 0.075 lb/ft3 5 12 5 3 7½ urv e (762) 14 ec tt ot he lef to f th is s yst em c 43⁄16 ot se l 217⁄16 15 (540) 30 10 211⁄4 5 (1175) 8 6 8 10 Volume (cfm X 1000) 10 15 12 20 14 16 25 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/671)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/740)3) Maximum RPM = 1450 Tip Speed (ft/min.) = RPM x 7.07 (Tip Speed (m/s) = RPM x 0.0359) Maximum Motor Frame Size = 256T SWB-327-AF CFM OV 6000 1431 6700 1599 7400 1766 8100 1933 8800 2100 9500 2267 10200 2434 10900 2601 11600 2768 12300 2935 13000 3102 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 664 0.86 10 / 72 719 1.07 11.1 / 74 776 1.31 12.6 / 76 834 1.59 14.2 / 77 893 1.91 16.1 / 79 953 2.28 18.3 / 81 1013 2.70 21 / 83 1074 3.17 22 / 84 1136 3.70 23 / 85 1198 4.30 24 / 86 1260 4.96 26 / 87 1 755 1.38 11.3 / 74 804 1.63 12.4 / 75 856 1.92 13.7 / 77 908 2.24 15.4 / 79 963 2.61 17.3 / 81 1019 3.03 19.2 / 82 1075 3.51 20 / 83 1133 4.03 22 / 84 1192 4.61 23 / 85 1251 5.26 24 / 87 1311 5.96 26 / 88 1.5 833 1.90 12.6 / 75 881 2.21 13.8 / 77 928 2.55 15.3 / 79 977 2.93 16.8 / 80 1028 3.35 18.1 / 82 1081 3.82 19.3 / 83 1134 4.33 21 / 84 1189 4.91 22 / 85 1245 5.54 23 / 86 1301 6.24 25 / 87 1358 7.00 26 / 88 Static Pressure in Inches 2 2.5 3 906 975 2.44 3.01 14 / 77 15.6 /79 946 1013 1075 2.80 3.41 4.04 15.3 / 79 16.6 / 80 17.4 / 81 994 1052 1112 3.21 3.85 4.52 16.8 / 80 17.4 / 81 18.2 / 82 1041 1100 1152 3.64 4.35 5.05 17.7 / 81 18.4 / 82 19.1 / 82 1089 1147 1200 4.11 4.88 5.65 18.7 / 82 19.4 / 83 20 / 83 1139 1194 1247 4.62 5.45 6.29 19.7 / 83 20 / 84 21 / 84 1190 1243 1294 5.19 6.07 6.95 21 / 84 21 / 84 22 / 85 1242 1293 1342 5.81 6.73 7.68 22 / 85 23 / 85 23 / 86 1296 1345 1392 6.49 7.46 8.46 23 / 86 24 / 86 25 / 87 1351 1398 1443 7.23 8.25 9.29 25 / 87 25 / 87 26 / 87 1406 8.04 26 / 88 wg 3.5 4 1169 1223 5.22 5.93 19 / 82 19.9 / 83 1208 1260 5.79 6.54 19.8 / 83 21 / 84 1247 1299 6.41 7.21 21 / 84 22 / 85 1295 1340 7.12 7.94 22 / 85 23 / 85 1343 1388 7.86 8.75 23 / 86 24 / 86 1390 1435 8.62 9.59 24 / 86 25 / 87 1438 9.46 25 / 87 4.5 5 1310 7.32 22 / 85 1348 8.03 22 / 85 1387 8.79 23 / 86 1429 9.63 25 / 87 1395 8.86 23 / 86 1433 9.66 24 / 87 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 53 SWB-330 - Belt Drive Series 300 503⁄4 7 (848) (605) (106) 16 6 this sys tem to the left of D 5 0 5 0 79 0 76 35 Wheel Diameter = 30 (762) Shaft Diameter = 115⁄16 (49) Outlet Area = 5.17 ft2 (0.480 m 2 ) ^Approximate Unit Weight = 1088 lb. (495 kg) 0 11 0 60 664 3 47 527 9 1 1 32 2 54 (1372) 583⁄16 (1478) 381⁄2 (978) ¾ 90 317⁄8 (810) 2 4 10 353⁄4 (908) 3 1 (930) 6 4 12 (89) 8 1½ 31⁄2 (1419) 365⁄8 10 2 (895) 557⁄8 5 no ts e le ct 351⁄4 681⁄4 (1734) 12 o (808) Static Pressure (in. wg) 3113⁄16 3 315⁄8 Static Pressure (Pa x 100) 14 (803) RPM HP Density 0.075 lb/ft3 curv e (587) 43⁄16 15 2313⁄16 10 333⁄8 5 231⁄8 7½ (1289) 10 15 Volume (cfm X 1000) 10 15 20 25 20 30 35 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/527)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/581)3) Maximum RPM = 1279 Tip Speed (ft/min.) = RPM x 7.85 (Tip Speed (m/s) = RPM x 0.0399) Maximum Motor Frame Size = 256T SWB-330 CFM OV 7000 1353 8000 1547 9000 1740 10000 1934 11000 2127 12000 2321 13000 2514 14000 2707 15000 2901 16000 3094 17000 3288 54 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 1 531 630 1.02 1.62 12.7 / 76 13.8 / 77 580 671 1.31 2.00 13.9 / 77 15 / 79 631 713 1.67 2.43 15.1 / 79 16 / 80 686 755 2.12 2.93 16.7 / 80 17.4 / 81 742 804 2.65 3.51 18.4 / 82 19 / 82 799 855 3.28 4.18 20 / 83 21 / 84 857 906 4.00 4.95 22 / 85 23 / 85 915 962 4.84 5.85 25 / 86 25 / 87 974 1018 5.79 6.87 27 / 88 28 / 88 1033 1075 6.86 8.02 30 / 90 31 / 90 1093 1132 8.07 9.31 33 / 91 34 / 92 1.5 709 2.25 15.3 / 79 748 2.69 16.3 / 80 789 3.21 17.5 / 81 831 3.80 18.7 / 82 872 4.45 19.9 / 83 914 5.19 21 / 84 961 6.02 24 / 86 1011 6.96 26 / 87 1062 8.01 28 / 89 1114 9.19 32 / 91 1170 10.5 35 / 92 Static Pressure 2 2.5 782 849 2.93 3.65 16.7 / 80 18.5 / 82 816 879 3.42 4.19 17.6 / 81 19.1 / 82 854 914 4.00 4.82 18.7 / 82 19.9 / 83 894 953 4.66 5.54 19.9 / 83 21 / 84 936 993 5.40 6.35 21 / 84 23 / 85 978 1034 6.23 7.26 23 / 85 24 / 86 1019 1076 7.13 8.27 25 / 86 26 / 88 1061 1117 8.13 9.35 27 / 88 28 / 89 1109 1159 9.25 10.5 30 / 89 31 / 90 1159 1202 10.5 11.8 33 / 91 34 / 92 1210 1252 11.9 13.3 37 / 93 39 / 94 in Inches 3 911 4.39 20 / 84 940 5.00 21 / 84 970 5.68 21 / 84 1007 6.46 23 / 85 1045 7.32 24 / 86 1085 8.30 26 / 87 1127 9.38 28 / 88 1169 10.6 30 / 90 1210 11.8 33 / 91 1252 13.2 36 / 93 wg 3.5 4 4.5 5 997 5.83 23 / 86 1026 6.58 23 / 86 1057 7.39 24 / 86 1095 8.33 25 / 87 1134 9.36 27 / 88 1174 10.5 29 / 89 1215 11.8 32 / 91 1257 13.1 35 / 92 1050 6.69 25 / 87 1079 7.50 25 /87 1109 8.38 26 / 87 1142 9.35 27 / 88 1180 10.5 29 / 89 1219 11.6 31 / 90 1259 13.0 34 / 92 1128 8.44 27 / 88 1158 9.39 27 / 89 1188 10.4 28 / 89 1224 11.6 30 / 90 1262 12.8 33 / 91 1175 9.40 29 / 90 1204 10.4 29 / 90 1234 11.5 30 / 90 1266 12.7 32 / 91 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 25 40 SWB-330-AF - Belt Drive Series 300 503⁄4 6 urve stem c this sy ft o f he le 02 11 56 3 2 38 ⁄2 (978) 1 51 54 (1372) 583⁄16 (1478) 1 1 ¾ 2 81 2 317⁄8 (810) 2 9 70 4 64 353⁄4 (908) 4 2 3 96 (930) 6 3 5 130 13 (1419) (89) RPM HP Density 0.075 lb/ft3 12 365⁄8 8 1½ 3 ⁄2 1 4 to t 351⁄4 (895) 557⁄8 10 Static Pressure (in. wg) 681⁄4 (1734) 5 12 13 no ts ele ct (106) Do (605) Static Pressure (Pa x 100) (808) (848) 14 15 31 ⁄16 43⁄16 3 31 ⁄8 (803) 5 2313⁄16 10 (587) 333⁄8 7½ 231⁄8 5 (1289) 0 Wheel Diameter = 30 (762) Shaft Diameter = 115⁄16 (49) Outlet Area = 5.17 ft2 (0.480 m 2 ) ^Approximate Unit Weight = 998 lb. (454 kg) 0 0 5 0 10 15 Volume (cfm X 1000) 10 20 20 25 30 40 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/563)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/621)3) Maximum RPM = 1305 Tip Speed (ft/min.) = RPM x 7.85 (Tip Speed (m/s) = RPM x 0.0399) Maximum Motor Frame Size = 256T SWB-330-AF CFM OV 8000 1547 8800 1702 9600 1856 10400 2011 11200 2166 12000 2321 12800 2475 13600 2630 14400 2785 15200 2940 16000 3094 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 631 1.23 11.7 / 75 678 1.49 13 / 76 726 1.79 14.1 / 78 775 2.14 15.6 / 79 825 2.53 17.3 / 81 875 2.97 19.2 / 82 925 3.46 21 / 84 976 4.02 24 / 86 1027 4.64 26 / 87 1079 5.32 27 / 88 1131 6.07 28 / 89 1 709 1.91 12.9 / 76 752 2.22 14 / 77 795 2.58 15.3 / 79 840 2.97 16.8 / 80 886 3.42 18.5 / 82 933 3.92 20 / 83 980 4.48 23 / 85 1028 5.09 24 / 86 1077 5.76 26 / 87 1127 6.50 27 / 88 1176 7.31 28 / 89 Static Pressure in Inches 1.5 2 2.5 3 779 839 901 957 2.61 3.31 4.05 4.81 14.2 / 77 15.5 / 79 16.9 / 80 18.4 / 82 818 878 933 988 2.98 3.76 4.53 5.34 15.4 / 79 16.7 / 80 18 / 81 19.6 / 83 858 918 970 1020 3.40 4.24 5.08 5.93 16.6 / 80 18 / 81 19.5 / 83 21 / 84 900 957 1010 1056 3.85 4.75 5.68 6.57 18 / 81 19.5 / 83 21 / 84 21 / 84 944 997 1049 1097 4.35 5.32 6.29 7.29 19.6 / 83 21 / 84 22 / 85 22 / 85 987 1039 1088 1136 4.91 5.92 6.96 8.01 22 / 84 22 / 85 23 / 85 23 / 86 1033 1082 1129 1175 5.51 6.58 7.68 8.79 23 / 86 23 / 86 24 / 86 24 / 86 1079 1126 1172 1215 6.18 7.31 8.46 9.64 24 / 86 24 / 86 25 / 87 25 / 87 1125 1171 1215 1257 6.92 8.09 9.30 10.5 26 / 87 26 / 87 26 / 87 27 / 88 1172 1217 1259 1300 7.72 8.95 10.2 11.5 27 / 88 27 / 88 27 / 88 28 / 89 1220 1263 1303 8.59 9.87 11.2 28 / 89 29 / 89 29 / 89 wg 3.5 4 4.5 5 1039 6.18 21 / 83 1071 6.81 21 / 84 1103 7.49 22 / 85 1139 8.25 23 / 86 1180 9.08 24 / 86 1219 9.92 25 / 87 1258 10.8 26 / 88 1298 11.8 27 / 88 1119 7.72 22 / 85 1150 8.45 23 / 85 1182 9.24 24 / 86 1219 10.1 25 / 87 1260 11.1 26 / 87 1299 12.0 27 / 88 1195 9.43 24 / 86 1227 10.3 25 / 87 1259 11.2 25 / 87 1297 12.2 27 / 88 1238 10.4 25 / 87 1269 11.3 25 / 87 1301 12.3 26 / 88 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 55 SWB-333 - Belt Drive Series 300 559⁄16 7 5 56 ⁄8 (1432) 609⁄16 (1538) 1 3 419⁄16 (1056) Wheel Diameter = 33 (838) Shaft Diameter = 115⁄16 (49) Outlet Area = 6.26 ft2 (0.582 m 2 ) ^Approximate Unit Weight = 1231 lb. (560 kg) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood 0 0 0 5 0 87 1 76 9 4 2 317⁄8 (810) 2 1 383⁄4 (984) 3 95 (1016) 6 1½ (89) 8 4 no t 31⁄2 (1543) 40 10 63 11 97 10 (1894) (813) 2 603⁄4 5 3 381⁄4 749⁄16 12 Do (889) Static Pressure (in. wg) 35 (878) Static Pressure (Pa x 100) 349⁄16 curv e 6 14 this syst em (106) RPM HP Density 0.075 lb/ft3 left of (665) the (848) 16 se lec t to (635) 43⁄16 20 263⁄16 15 333⁄8 10 25 7½ (1175) 1 64 2 56 50 1 44 9 5 10 15 20 Volume (cfm X 1000) 10 20 30 25 40 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/445)3 (Maximum KW at a given RPM = (RPM/491)3) Maximum RPM = 1163 Tip Speed (ft/min.) = RPM x 8.64 (Tip Speed (m/s) = RPM x 0.0439) Maximum Motor Frame Size = 256T SWB-333 CFM OV 7500 1198 9000 1437 10500 1677 12000 1916 13500 2156 15000 2396 16500 2635 18000 2875 19500 3115 21000 3354 22500 3594 56 RPM BHP Sones / LwiA RPM BHP Sones RPM BHP Sones / LwiA RPM BHP Sones RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 440 0.96 10 / 71 489 1.32 11.7 / 74 547 1.81 14.1 / 77 606 2.42 16.8 / 80 666 3.17 19.8 / 83 727 4.08 23 / 85 789 5.16 26 / 87 852 6.44 29 / 89 916 7.94 33 / 91 981 9.67 38 / 93 1046 11.6 42 / 95 Static Pressure in Inches 1 1.5 2 2.5 3 535 615 686 756 821 1.61 2.31 3.09 3.94 4.86 11.3 / 74 13 / 76 14.9 / 78 17.8 / 81 21 / 83 576 650 717 779 836 2.09 2.87 3.71 4.62 5.57 13.1 / 76 14.7 / 78 16.1 / 79 17.6 / 81 19.7 / 83 619 690 753 811 867 2.68 3.57 4.49 5.43 6.47 15.3 / 78 16.8 / 80 18 / 81 19.2 / 82 21 / 83 666 733 794 849 901 3.36 4.41 5.41 6.46 7.53 17.8 / 81 19 / 82 20 / 83 21 / 84 23 / 85 721 778 836 890 940 4.21 5.34 6.50 7.64 8.81 20 / 83 21 / 84 23 / 85 24 / 86 25 / 87 779 826 880 932 980 5.23 6.40 7.72 9.00 10.3 23 / 85 24 / 86 25 / 87 27 / 88 28 / 88 838 882 927 976 1023 6.44 7.70 9.05 10.5 11.9 26 / 87 27 / 88 29 / 89 30 / 89 31 / 90 898 940 978 1023 1067 7.83 9.21 10.6 12.1 13.7 30 / 90 31 / 90 32 / 91 34 / 91 35 / 92 958 998 1035 1070 1114 9.42 10.9 12.4 14.0 15.7 34 / 92 36 / 92 36 / 93 37 / 93 38 / 93 1019 1058 1093 1127 1161 11.3 12.9 14.5 16.1 17.8 39 / 94 39 / 94 40 / 94 41 / 95 42 / 95 1081 1117 1152 13.3 15.1 16.8 43 / 95 43 / 96 45 / 96 wg 3.5 4 4.5 5 895 6.60 23 / 85 919 7.55 22 / 85 950 8.66 24 / 86 987 10.0 27 / 87 1026 11.6 30 / 89 1067 13.3 32 / 91 1110 15.3 36 / 92 1154 17.4 39 / 94 951 7.68 26 / 87 968 8.65 25 / 86 999 9.86 26 / 87 1031 11.2 28 / 88 1070 12.9 31 / 90 1109 14.7 33 / 91 1151 16.8 37 / 93 1004 8.80 31 / 89 1018 9.83 28 / 88 1044 11.1 27 / 88 1075 12.5 29 / 89 1111 14.2 32 / 90 1150 16.1 35 / 92 1068 11.1 31 / 90 1088 12.3 29 / 89 1118 13.9 30 / 90 1150 15.6 33 / 91 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 30 50 SWB-333-AF - Belt Drive Series 300 559⁄16 6 (106) 5 38 ⁄4 1 (1894) 603⁄4 (813) 3 ⁄2 (1543) 1 Wheel Diameter = 33 (838) Shaft Diameter = 115⁄16 (49) Outlet Area = 6.26 ft2 (0.582 m 2 ) ^Approximate Unit Weight = 1166 lb. (530 kg) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood 0 0 5 0 5 10 15 Volume (cfm X 1000) 10 86 0 69 3 56 ⁄8 (1432) 3 609⁄16 (1538) 6 55 07 2 Do 38 1 94 2 2 10 317⁄8 (810) 4 3 4 82 383⁄4 (984) 419⁄16 (1056) 6 RPM HP Density 0.075 lb/ft3 11 (89) (1016) 8 4 1½ 40 10 2 749⁄16 3 (889) Static Pressure (in. wg) 35 (878) Static Pressure (Pa x 100) 12 349⁄16 10 is s yst em cur ve (665) lef to f th (848) 14 no ts ele ct to the 43⁄16 20 263⁄16 15 (635) 333⁄8 7½ 25 5 (1175) 20 20 25 30 40 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/482)3 (Maximum KW at a given RPM = (RPM/531)3) Maximum RPM = 1186 Tip Speed (ft/min.) = RPM x 8.64 (Tip Speed (m/s) = RPM x 0.0439) Maximum Motor Frame Size = 256T SWB-333-AF CFM 9000 OV 1437 10000 1597 11000 1757 12000 1916 13000 2076 14000 2236 15000 2396 16000 2555 17000 2715 18000 2875 19000 3035 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 541 1.25 12.3 / 75 584 1.52 14.3 / 77 628 1.84 16.5 / 79 674 2.21 18.9 / 82 719 2.65 21 / 83 766 3.14 22 / 84 812 3.70 24 / 86 859 4.33 26 / 87 907 5.03 28 / 88 954 5.82 30 / 90 1002 6.67 32 / 91 Static Pressure 1 1.5 2 2.5 613 679 742 801 2.01 2.79 3.61 4.42 14.1 / 77 16.3 / 79 19.4 / 81 21 / 82 652 714 772 828 2.36 3.21 4.09 5.01 16.1 / 79 17.7 / 80 20 / 82 24 / 83 692 751 805 858 2.75 3.67 4.62 5.61 17.8 / 81 19.2 / 82 21 / 83 25 / 84 734 789 841 890 3.20 4.19 5.21 6.25 19.4 / 82 21 / 83 22 / 84 25 / 85 776 829 878 925 3.69 4.77 5.86 6.96 21 / 83 22 / 84 24 / 85 26 / 87 820 870 916 962 4.23 5.41 6.56 7.74 23 / 85 24 / 86 26 / 87 28 / 88 864 911 957 999 4.84 6.09 7.33 8.59 25 / 86 26 / 87 27 / 88 30 / 89 909 954 997 1039 5.52 6.83 8.17 9.49 27 / 88 28 / 88 29 / 89 31 / 90 954 998 1039 1079 6.28 7.65 9.08 10.5 29 / 89 30 / 90 31 / 90 33 / 91 1000 1042 1082 1120 7.13 8.54 10.0 11.6 31 / 90 32 / 91 33 / 91 34 / 92 1046 1086 1125 1161 8.07 9.51 11.1 12.7 33 / 91 34 / 92 36 / 92 37 / 93 in Inches wg 3 3.5 881 5.91 25 / 85 909 6.62 31 / 86 938 7.33 31 / 87 969 8.10 31 / 88 1005 8.94 31 / 89 1041 9.85 32 / 90 1078 10.8 33 / 91 1117 11.9 35 / 91 1157 13.0 36 / 92 956 7.63 31 / 87 985 8.44 39 / 89 1015 9.27 37 / 89 1046 10.2 35 / 90 1081 11.1 34 / 91 1117 12.2 36 / 91 1154 13.3 37 / 92 4 4.5 5 1003 8.55 31 / 89 1029 9.58 38 / 90 1058 10.5 43 / 91 1088 11.4 41 / 91 1119 12.5 39 / 92 1154 13.6 39 / 92 1072 10.6 36 / 90 1099 11.7 43 / 91 1128 12.7 46 / 92 1158 13.8 44 / 93 1139 12.8 42 / 92 1167 14.0 50 / 93 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 57 SWB-336 SWB- - - Belt Drive Series Series 300 61 7 (735) (106) 6 Wheel Diameter = 361⁄2 (927) Shaft Diameter = 23⁄16 (56) Outlet Area = 7.66 ft2 (0.712 m 2 ) ^Approximate Unit Weight = 1530 lb. (695 kg) this sy 1 1 0 0 0 10 73 6 64 54 2 376 430 474 5 51 0 1½ 10 2 591⁄8 (1502) 635⁄16 (1608) 2 4 10 7 317⁄8 (810) 3 0 81 41 ⁄2 (1054) 455⁄16 (1151) 1 6 92 (1130) 8 to t he left of (1705) 4 2 (89) 10 3 31⁄2 441⁄2 (1067) 671⁄8 5 no ts ele ct 42 823⁄4 (2102) 12 Do (983) Static Pressure (in. wg) (972) 5 3811⁄16 Static Pressure (Pa x 100) 14 381⁄4 RPM HP Density 0.075 lb/ft3 stem curv e (848) 16 25 43⁄16 20 2815⁄16 15 (692) 333⁄8 10 271⁄4 7½ (1549) 3 15 20 Volume (cfm X 1000) 20 30 25 30 40 50 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/376)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/415)3) Maximum RPM = 1051 Tip Speed (ft/min.) = RPM x 9.56 (Tip Speed (m/s) = RPM x 0.0486) Maximum Motor Frame Size = 286T SWB-336 CFM OV 7500 979 9500 1240 11500 1501 13500 1762 15500 2023 17500 2284 19500 2545 21500 2806 23500 3067 25500 3328 27500 3590 58 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 362 0.86 10.7 / 71 405 1.25 11.9 / 73 456 1.77 13.7 / 76 513 2.46 16.2 / 79 572 3.35 19.1 / 82 631 4.45 22 / 85 692 5.79 26 / 87 754 7.41 29 / 89 817 9.33 33 / 91 881 11.6 38 / 93 944 14.2 43 / 96 1 454 1.54 10.8 / 73 490 2.06 12.6 / 75 531 2.74 14.6 / 78 575 3.56 17.1 / 80 623 4.54 19.9 / 82 680 5.80 23 / 85 738 7.30 27 / 87 796 9.07 30 / 90 855 11.1 34 / 92 916 13.5 39 / 94 976 16.3 45 / 96 1.5 532 2.33 12.9 / 76 561 2.94 14.1 / 77 597 3.73 16.1 / 79 638 4.72 18.7 / 81 680 5.89 21 / 84 727 7.21 24 / 86 778 8.80 27 / 88 835 10.7 31 / 90 892 13.0 35 / 92 951 15.5 40 / 94 1010 18.4 46 / 96 Static Pressure 2 2.5 606 3.24 16.1 / 79 625 685 3.90 4.95 15.9 / 79 18.7 / 82 656 712 4.76 5.91 17.8 / 81 19.3 / 82 694 745 5.87 7.07 20 / 83 21 / 84 734 784 7.20 8.52 22 / 85 24 / 85 777 825 8.75 10.2 25 / 86 27 / 87 823 867 10.4 12.2 28 / 88 30 / 89 870 913 12.4 14.3 32 / 90 33 / 91 926 959 14.8 16.6 37 / 92 38 / 93 983 1014 17.4 19.4 42 / 95 43 / 95 1041 20.5 47 / 96 in Inches wg 3 3.5 745 6.09 22 / 84 764 7.09 21 / 83 794 8.35 22 / 85 830 9.88 25 / 86 869 11.7 28 / 88 910 13.8 31 / 90 953 16.2 35 / 92 999 18.7 40 / 94 1045 21.5 44 / 95 813 8.34 23 / 85 841 9.70 24 / 86 873 11.3 26 / 87 911 13.2 29 / 89 951 15.4 33 / 91 992 18.0 37 / 92 1035 20.8 41 / 94 4 4.5 5 863 9.70 26 / 87 885 11.1 25 / 87 915 12.8 27 / 88 951 14.8 31 / 90 989 17.1 34 / 91 1030 19.8 38 / 93 911 11.1 30 / 89 926 12.5 28 / 88 957 14.3 29 / 89 988 16.4 32 / 90 1026 18.8 35 / 92 970 14.1 31 / 90 996 15.9 31 / 90 1026 18.0 33 / 91 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 35 SWB-336-AF - Belt Drive Series 300 61 6 (106) 5 (983) 42 (1067) 671⁄8 9 79 8 69 2 1 7 0 4 591⁄8 (1502) 635⁄16 (1608) 8 46 51 317⁄8 (810) 2 58 411⁄2 (1054) 455⁄16 (1151) 4 3 9 (89) (1130) 6 87 441⁄2 (1705) 1½ 31⁄2 8 2 (2102) 4 47 10 06 10 823⁄4 10 Static Pressure (in. wg) 3811⁄16 3 38 ⁄4 (972) Static Pressure (Pa x 100) 12 1 RPM HP Density 0.075 lb/ft3 25 (735) 14 20 (848) 43⁄16 5 (692) 2815⁄16 15 33 ⁄8 3 10 271⁄4 7½ (1549) 0 0 5 10 15 20 25 30 Volume (cfm X 1000) Wheel Diameter = 361⁄2 (927) Shaft Diameter = 23⁄16 (56) Outlet Area = 7.66 ft2 (0.712 m 2 ) ^Approximate Unit Weight = 1445 lb. (657 kg) 0 10 20 30 40 50 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/408)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/450)3) Maximum RPM = 1047 Tip Speed (ft/min.) = RPM x 9.56 (Tip Speed (m/s) = RPM x 0.0485) Maximum Motor Frame Size = 286T SWB-336-AF CFM OV 12000 1566 13000 1697 14000 1827 15000 1958 16000 2088 17000 2219 18000 2349 19000 2480 20000 2610 21000 2741 22000 2872 RPM BHP Sones / LwiA RPM BHP Sones RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 1 1.5 521 583 639 1.80 2.80 3.82 14.6 / 78 16.1 / 79 18.2 / 81 553 612 666 2.10 3.18 4.27 16.2 / 79 17.7 / 81 19.9 / 82 586 642 693 2.44 3.61 4.77 18 / 81 19.6 / 82 21 / 83 620 673 723 2.84 4.06 5.31 20 / 83 22 / 84 22 / 84 654 705 752 3.28 4.56 5.89 22 / 84 23 / 85 24 / 85 688 737 782 3.77 5.10 6.53 24 / 85 24 / 86 25 / 86 722 770 813 4.32 5.70 7.21 25 / 86 26 / 87 27 / 87 757 802 845 4.92 6.35 7.92 27 / 87 28 / 88 28 / 88 792 836 876 5.58 7.06 8.69 28 / 88 29 / 89 30 / 89 827 869 909 6.31 7.85 9.53 30 / 89 31 / 90 32 / 90 862 903 941 7.10 8.71 10.4 32 / 90 33 / 91 34 / 91 Static Pressure 2 2.5 693 744 4.89 6.00 21 / 82 24 / 84 716 766 5.41 6.58 22 / 83 25 / 85 742 788 5.96 7.20 23 / 84 26 / 85 769 813 6.57 7.87 24 / 85 26 / 86 796 839 7.23 8.59 25 / 86 27 / 87 825 866 7.93 9.37 27 / 87 29 / 88 854 893 8.69 10.2 28 / 88 30 / 89 884 922 9.50 11.1 30 / 89 31 / 90 915 952 10.4 12.0 31 / 90 33 / 91 946 981 11.3 13.0 33 / 91 35 / 92 977 1012 12.3 14.1 35 / 92 37 / 93 in Inches 3 792 7.06 26 / 85 812 7.80 28 / 86 833 8.48 30 / 87 856 9.21 31 / 88 879 9.99 31 / 88 905 10.8 31 / 89 932 11.7 32 / 90 959 12.7 34 / 91 986 13.7 35 / 92 1016 14.8 37 / 92 1045 15.9 38 / 93 wg 3.5 4 4.5 856 8.93 30 / 87 876 9.79 34 / 88 897 10.6 37 / 89 920 11.4 37 / 90 942 12.3 36 / 90 968 13.3 37 / 91 995 14.3 37 / 92 1021 15.4 38 / 92 917 11.0 34 / 89 937 12.0 40 / 90 959 12.9 44 / 91 981 13.9 43 / 92 1003 14.9 42 / 92 1029 16.0 42 / 93 976 13.3 40 / 91 996 14.4 47 / 92 1017 15.4 50 / 93 1040 16.5 48 / 93 5 1032 15.8 45 / 93 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 59 SWB-340 - Belt Drive Series 300 6613⁄16 7 this sys tem curv e to the left of 5 0 10 40 4 10 8 1 0 0 9 6 D 62 54 46 87 Wheel Diameter = 401⁄4 (1022) Shaft Diameter = 23⁄16 (56) Outlet Area = 9.31 ft2 (0.865 m 2 ) ^Approximate Unit Weight = 1709 lb. (777 kg) 0 1 2 621⁄16 (1576) 661⁄4 (1683) 495⁄16 (1253) 4 2 317⁄8 (810) 2 2 69 451⁄2 (1156) 3 2 79 (1194) 6 RPM HP Density 0.075 lb/ft3 93 (89) 8 4 no ts ele ct (1819) 10 3 31⁄2 47 (1168) 5 o 715⁄8 12 Static Pressure (in. wg) 46 893⁄16 (2265) 14 Static Pressure (Pa x 100) 42 ⁄8 (1083) (106) 5 3 6 5 42 ⁄16 (1072) (810) 4 ⁄16 25 (848) 31 ⁄8 16 3 7½ (752) 7 20 33 ⁄8 3 15 295⁄8 10 (1697) 3 15 20 25 Volume (cfm X 1000) 20 30 40 30 35 50 60 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/321)3 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood (Maximum KW at a given RPM = (RPM/354)3) Maximum RPM = 936 Tip Speed (ft/min.) = RPM x 10.54 (Tip Speed (m/s) = RPM x 0.0535) Maximum Motor Frame Size = 286T SWB-340 CFM OV 12500 1342 14250 1530 16000 1718 17750 1906 19500 2094 21250 2282 23000 2470 24750 2658 26500 2846 28250 3034 30000 3222 60 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA 0.5 391 1.80 10.3 / 71 428 2.32 12.6 / 74 466 2.95 15.2 / 77 506 3.72 18.1 / 79 547 4.63 19.9 / 82 589 5.70 23 / 84 631 6.94 26 / 86 673 8.37 29 / 88 716 9.98 32 / 90 758 11.8 35 / 91 801 13.8 38 / 93 1 460 2.85 12.4 / 74 488 3.51 14.8 / 76 521 4.25 16.7 / 78 555 5.12 18.5 / 80 592 6.14 21 / 82 629 7.31 24 / 85 668 8.65 27 / 87 708 10.2 30 / 88 749 11.9 33 / 90 790 13.9 36 / 91 832 16.1 39 / 93 Static Pressure in Inches 1.5 2 2.5 3 521 575 625 671 3.92 5.06 6.29 7.56 13.9 / 76 15.6 / 78 17.3 / 80 19.4 / 81 547 599 646 691 4.70 5.93 7.22 8.61 15.8 / 78 17.4 / 79 19 / 81 20 / 82 575 625 670 712 5.60 6.95 8.34 9.76 17.8 / 80 19.4 / 81 21 / 83 22 / 84 603 652 697 738 6.63 8.10 9.60 11.1 19.9 / 81 22 / 83 23 / 84 24 / 85 636 680 724 764 7.75 9.40 11.0 12.7 22 / 83 24 / 85 25 / 85 26 / 86 670 710 751 791 9.02 10.8 12.6 14.4 25 / 86 26 / 86 27 / 87 28 / 87 706 744 780 818 10.5 12.4 14.3 16.3 28 / 87 29 / 88 30 / 88 31 / 89 743 778 813 846 12.1 14.1 16.2 18.3 30 / 89 31 / 89 32 / 90 33 / 90 781 814 847 879 14.0 16.1 18.2 20.5 33 / 90 34 / 91 35 / 91 36 / 92 819 851 881 912 16.0 18.2 20.5 22.8 36 / 92 37 / 92 39 / 92 40 / 93 860 889 918 18.3 20.6 23.0 40 / 93 41 / 93 42 / 94 wg 3.5 4 4.5 5 733 10.0 22 / 83 754 11.3 23 / 84 776 12.7 25 / 86 802 14.4 27 / 87 828 16.2 29 / 88 855 18.2 32 / 89 882 20.4 35 / 91 910 22.7 38 / 92 793 12.9 24 / 85 813 14.4 26 / 86 837 16.1 28 / 88 863 18.0 31 / 89 889 20.1 33 / 90 917 22.4 36 / 91 829 14.5 26 / 86 850 16.1 27 / 87 871 17.8 29 / 88 896 19.9 32 / 89 922 22.1 34 / 91 885 17.9 29 / 88 905 19.7 31 / 89 928 21.8 33 / 90 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 40 SWB-340-AF - Belt Drive Series 300 6613⁄16 6 (848) (810) (106) 5 7 ½ 425⁄8 (1083) 89 ⁄16 3 46 71 ⁄8 5 (2265) (89) Wheel Diameter = 40 ⁄4 (1022) Shaft Diameter = 23⁄16 (56) Outlet Area = 9.31 ft2 (0.865 m 2 ) ^Approximate Unit Weight = 1579 lb. (718 kg) 1 Do 0 0 n 5 3 10 58 8 49 43 3 0 2 1 621⁄16 (1576) 661⁄4 (1683) 3 2 67 2 317⁄8 (810) 3 9 4 5 74 451⁄2 (1156) 495⁄16 (1253) 6 4 8 84 (1194) 8 RPM HP Density 0.075 lb/ft3 94 47 (1168) (1819) 31⁄2 10 Static Pressure (in. wg) 423⁄16 Static Pressure (Pa x 100) 12 (1072) 15 10 he lef to f th is s yst em cur ve (752) 14 43⁄16 el ec tt ot 317⁄8 ot s 333⁄8 25 295⁄8 20 (1697) 6 15 20 Volume (cfm X 1000) 25 30 35 1 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood 0 10 20 30 40 50 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/344)3 (Maximum KW at a given RPM = (RPM/379)3) Maximum RPM = 949 Tip Speed (ft/min.) = RPM x 10.54 (Tip Speed (m/s) = RPM x 0.0535) SWB-340-AF CFM OV 15000 1611 16500 1772 18000 1933 19500 2094 21000 2255 22500 2416 24000 2577 25500 2738 27000 2900 28500 3061 30000 3222 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA Maximum Motor Frame Size = 286T Static Pressure in Inches 0.5 1 1.5 2 2.5 3 480 535 586 632 678 720 2.44 3.65 4.89 6.20 7.48 8.79 13.3 / 74 14.6 / 76 16 / 77 17.3 / 78 18.5 / 79 18.9 / 80 518 568 616 660 701 743 2.98 4.30 5.63 7.03 8.48 9.88 15.6 / 77 16.5 / 78 17.9 / 79 19.3 / 80 19.7 / 81 20 / 81 557 602 647 689 730 767 3.60 5.02 6.48 7.95 9.50 11.1 17.6 / 79 18.7 / 80 20 / 81 21 / 82 21 / 82 21 / 82 597 638 679 720 759 795 4.33 5.83 7.43 8.99 10.6 12.3 20 / 81 21 / 82 22 / 83 22 / 83 22 / 83 23 / 84 637 674 714 752 789 824 5.16 6.75 8.45 10.2 11.9 13.6 23 / 83 24 / 84 23 / 84 23 / 84 24 / 84 24 / 85 677 712 749 784 820 853 6.10 7.79 9.58 11.4 13.2 15.1 25 / 85 25 / 85 25 / 85 25 / 85 25 / 86 25 / 86 717 750 784 818 852 885 7.16 8.94 10.8 12.8 14.7 16.7 27 / 87 27 / 87 26 / 87 26 / 87 26 / 87 27 / 88 758 789 820 853 884 916 8.34 10.2 12.2 14.3 16.4 18.4 28 / 88 28 / 88 28 / 88 28 / 88 29 / 88 30 / 89 798 829 857 888 919 948 9.66 11.7 13.7 15.9 18.1 20.3 31 / 90 31 / 90 30 / 90 31 / 90 32 / 90 32 / 90 839 869 896 924 11.1 13.2 15.4 17.6 34 / 91 34 / 91 33 / 91 34 / 91 880 908 935 12.7 14.9 17.2 37 / 93 37 / 93 37 / 93 wg 3.5 4 4.5 782 11.3 21 / 82 806 12.6 22 / 83 830 14.0 23 / 84 858 15.4 25 / 86 886 17.0 27 / 87 916 18.6 29 / 88 947 20.4 31 / 90 819 12.8 21 / 83 842 14.2 22 / 84 865 15.7 24 / 85 889 17.3 26 / 86 918 18.9 28 / 88 947 20.7 30 / 89 876 15.8 24 / 85 899 17.4 25 / 86 923 19.1 27 / 87 947 20.9 29 / 89 5 931 19.1 27 / 87 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 61 SWB-344 - Belt Drive Series 300 733⁄8 7 (895) (119) 6 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood left of t his sys tem the t to ele c no ts 0 0 0 46 3 39 1 D 0 4 8 Wheel Diameter = 441⁄2 (1130) Shaft Diameter = 27⁄16 (62) Outlet Area = 11.39 ft2 (1.06 m 2 ) ^Approximate Unit Weight = 2127 lb. (967 kg) 0 1 58 53 6 2 705⁄16 (1786) 75 (1905) 2 4 66 363⁄4 (933) 3 73 50 (1270) 537⁄8 (1368) 6 4 3 (1321) 8 7 84 2 79 31⁄2 (2003) (89) 52 10 o 501⁄2 (1283) 787⁄8 5 5 985⁄8 (2505) 12 Static Pressure (in. wg) 471⁄8 (1197) 7½ 465⁄8 Static Pressure (Pa x 100) 14 (1184) RPM HP Density 0.075 lb/ft3 curv e (970) 16 30 411⁄16 25 351⁄4 10 (821) 383⁄16 20 325⁄16 15 (1864) 10 10 20 20 30 Volume (cfm X 1000) 30 40 50 40 60 70 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/271)3 (Maximum KW at a given RPM = (RPM/299)3) Maximum RPM = 847 Tip Speed (ft/min.) = RPM x 11.65 (Tip Speed (m/s) = RPM x 0.0592) Maximum Motor Frame Size = 324T SWB-344 CFM OV 15000 1316 17000 1492 19000 1668 21000 1843 23000 2019 25000 2194 27000 2370 29000 2546 31000 2721 33000 2897 35000 3072 62 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA Static Pressure 0.5 1 1.5 2 2.5 350 413 468 517 563 2.12 3.38 4.67 6.06 7.55 10.7 / 72 12.5 / 74 14.6 / 76 16.6 / 78 17.7 / 80 381 436 490 537 580 2.70 4.12 5.54 7.02 8.60 12.7 / 74 14.6 / 76 16.9 / 78 17.7 / 80 19.2 / 81 413 463 513 559 600 3.39 4.95 6.54 8.15 9.81 14.9 / 76 17.1 / 78 18.7 / 80 19.4 / 81 21 / 82 446 492 537 582 622 4.23 5.89 7.67 9.42 11.2 17.6 / 79 20 / 80 20 / 81 21 / 83 23 / 84 481 522 563 605 645 5.21 6.99 8.91 10.9 12.8 21 / 81 22 / 82 22 / 83 24 / 84 25 / 86 516 554 592 629 668 6.35 8.26 10.3 12.4 14.5 23 / 83 23 / 84 24 / 85 26 / 86 28 / 87 551 585 621 657 692 7.67 9.69 11.9 14.1 16.4 25 / 85 26 / 86 27 / 87 29 / 88 30 / 88 586 619 652 685 718 9.18 11.3 13.6 16.0 18.4 28 / 87 29 / 88 30 / 88 31 / 89 32 / 89 622 653 684 715 746 10.9 13.2 15.6 18.0 20.6 31 / 89 32 / 90 33 / 90 34 / 90 35 / 91 658 688 716 746 775 12.8 15.2 17.7 20.4 23.0 35 / 91 36 / 91 36 / 91 37 / 92 38 / 92 695 723 749 777 804 15.0 17.5 20.1 22.9 25.7 38 / 92 38 / 92 39 / 93 40 / 93 41 / 93 in Inches wg 3 3.5 621 10.3 21 / 83 639 11.6 23 / 84 659 13.1 25 / 85 682 14.7 27 / 87 704 16.6 29 / 88 727 18.6 31 / 89 751 20.9 33 / 90 775 23.3 36 / 91 804 25.8 39 / 92 832 28.6 42 / 94 660 12.0 23 / 84 677 13.4 24 / 85 694 14.9 26 / 86 716 16.7 28 / 87 738 18.7 30 / 88 761 20.9 32 / 89 784 23.3 34 / 91 807 25.9 37 / 92 831 28.7 40 / 93 4 4.5 712 15.3 25 / 86 730 17.0 27 / 87 748 18.8 29 / 88 770 20.9 31 / 89 792 23.2 33 / 90 815 25.7 35 / 91 838 28.4 38 / 92 745 17.2 27 / 87 763 19.0 28 / 88 780 21.0 30 / 88 800 23.1 32 / 89 822 25.6 34 / 91 844 28.2 37 / 92 5 794 21.1 29 / 88 811 23.2 31 / 89 829 25.4 33 / 90 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 50 80 SWB-344-AF - Belt Drive Series 300 733⁄8 6 (895) (119) 5 47 ⁄8 (1197) 985⁄8 501⁄2 (2505) 787⁄8 31⁄2 52 (1283) (2003) Wheel Diameter = 44 ⁄2 (1130) Shaft Diameter = 27⁄16 (62) Outlet Area = 11.39 ft2 (1.06 m 2 ) ^Approximate Unit Weight = 1997 lb. (908 kg) 0 0 5 0 10 15 20 25 30 Volume (cfm X 1000) 1 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood 0 8 0 42 Do 71 53 ⁄8 (1368) 1 8 2 705⁄16 (1786) 75 (1905) 49 363⁄4 (933) 7 4 3 2 7 62 0 57 50 (1270) 6 5 3 0 79 (1321) 8 7½ 4 860 (89) 10 Static Pressure (in. wg) 46 ⁄8 (1184) Static Pressure (Pa x 100) 12 1 5 RPM HP Density 0.075 lb/ft3 10 yst em cur ve (970) 15 14 411⁄16 no ts ele ct to the lef to f th is s 351⁄4 30 (821) 383⁄16 25 325⁄16 20 (1864) 20 35 40 40 45 60 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/291)3 (Maximum KW at a given RPM = (RPM/321)3) Maximum RPM = 860 Tip Speed (ft/min.) = RPM x 11.65 (Tip Speed (m/s) = RPM x 0.0592) Maximum Motor Frame Size = 324T SWB-344-AF CFM OV 15000 1316 17000 1492 19000 1668 21000 1843 23000 2019 25000 2194 27000 2370 29000 2546 31000 2721 33000 2897 35000 3072 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA Static Pressure 0.5 1 1.5 2 2.5 376 433 484 532 2.03 3.26 4.56 5.86 10.1 / 71 11.8 / 72 13.9 / 75 15.5 / 77 411 463 511 555 597 2.56 3.94 5.38 6.85 8.32 12 / 73 13.7 / 75 15.6 / 77 16.8 / 78 18.2 / 79 447 494 539 581 621 3.20 4.74 6.29 7.93 9.57 14.3 / 76 15.8 / 77 17.2 / 78 18.6 / 79 19.9 / 81 485 528 570 609 646 3.97 5.64 7.34 9.09 10.9 16.9 / 78 18 / 79 19.2 / 80 21 / 81 22 / 82 524 562 601 639 674 4.87 6.66 8.54 10.4 12.3 19.5 / 81 20 / 81 22 / 82 23 / 83 24 / 84 563 598 634 670 703 5.92 7.83 9.87 11.9 13.9 22 / 83 23 / 83 24 / 84 26 / 85 26 / 85 602 634 668 701 734 7.12 9.16 11.3 13.5 15.7 25 / 85 26 / 85 27 / 86 27 / 86 27 / 86 642 672 703 734 765 8.50 10.66 12.9 15.3 17.6 28 / 87 29 / 88 29 / 87 29 / 87 29 / 87 682 711 739 769 797 10.1 12.4 14.7 17.2 19.8 31 / 89 31 / 89 31 / 89 31 / 89 30 / 89 722 750 775 803 831 11.8 14.2 16.7 19.4 22.1 33 / 90 33 / 90 33 / 90 33 / 90 33 / 90 762 789 813 839 13.8 16.3 19.0 21.7 35 / 92 35 / 92 35 / 92 35 / 92 in Inches wg 3 3.5 659 11.2 21 / 82 682 12.7 23 / 83 707 14.4 24 / 84 736 16.1 26 / 85 765 17.9 27 / 87 795 20.0 29 / 88 826 22.3 31 / 89 858 24.8 33 / 90 694 12.9 22 / 82 717 14.5 23 / 83 740 16.3 25 / 85 766 18.2 26 / 86 795 20.2 28 / 87 823 22.4 29 / 88 854 24.8 31 / 90 4 4.5 5 750 16.4 24 / 84 773 18.3 25 / 85 797 20.4 27 / 86 823 22.6 28 / 88 851 24.9 30 / 89 804 20.3 26 / 86 827 22.5 27 / 87 851 25.0 29 / 88 833 22.3 26 / 86 856 24.7 28 / 88 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 63 SWB-349 - Belt Drive Series 300 805⁄16 7 (1397) 861⁄8 All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood curv e 8 Wheel Diameter = 49 (1245) Shaft Diameter = 27⁄16 (62) Outlet Area = 13.8 ft2 (1.28 m 2 ) ^Approximate Unit Weight = 2433 lb. (1106 kg) 0 9 1 49 45 8 2 D 13 0 57 71 2 73 ⁄16 (1875) 781⁄2 (1994) 2 4 7 363⁄4 (933) 3 5 541⁄2 (1384) 583⁄8 (1483) 6 62 (1448) 8 67 (89) 4 76 31⁄2 (2188) 57 10 this sys tem (2751) 5 o 55 1085⁄16 12 Static Pressure (in. wg) (1313) Static Pressure (Pa x 100) 51 ⁄16 7½ 51 ⁄16 (1303) 10 14 11 5 RPM HP Density 0.075 lb/ft3 6 to the left of (119) no ts ele ct (970) (984) 40 (894) 16 30 411⁄16 25 38 ⁄16 383⁄4 3 20 353⁄16 15 (2040) 0 0 10 0 20 20 30 40 Volume (cfm X 1000) 40 60 Volume (m3/hr x 1000) 50 80 Maximum BHP at a given RPM = (RPM/231)3 (Maximum KW at a given RPM = (RPM/255)3) Maximum RPM = 769 Tip Speed (ft/min.) = RPM x 12.83 (Tip Speed (m/s) = RPM x 0.0652) Maximum Motor Frame Size = 324T SWB-349 CFM OV 20000 1449 22500 1630 25000 1811 27500 1992 30000 2173 32500 2355 35000 2536 37500 2717 40000 2898 42500 3079 45000 3260 64 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA Static Pressure 0.5 1 1.5 2 2.5 339 391 440 483 523 3.08 4.76 6.44 8.20 10.1 13 / 74 14.7 / 76 16.7 / 78 18.8 / 80 20 / 81 368 415 461 503 541 3.91 5.77 7.65 9.57 11.5 15.1 / 77 17.1 / 78 19.1 / 80 21 / 82 21 / 83 399 442 483 524 561 4.92 6.92 9.03 11.1 13.3 17.6 / 79 19.7 / 80 22 / 82 23 / 83 23 / 84 431 470 508 546 582 6.11 8.26 10.6 12.9 15.2 20 / 81 23 / 82 24 / 84 24 / 84 25 / 86 464 499 534 568 604 7.51 9.80 12.3 14.8 17.3 24 / 83 26 / 84 26 / 85 26 / 86 28 / 87 497 529 562 594 626 9.13 11.6 14.2 16.9 19.7 28 / 86 28 / 86 28 / 87 29 / 87 31 / 88 530 560 591 621 650 11.0 13.6 16.3 19.2 22.2 29 / 87 29 / 88 30 / 88 32 / 89 34 / 90 564 592 620 648 676 13.1 15.9 18.8 21.8 24.9 32 / 89 33 / 90 34 / 90 35 / 91 37 / 91 598 625 650 677 703 15.5 18.5 21.5 24.7 27.9 35 / 91 36 / 91 38 / 92 39 / 92 40 / 93 632 657 681 707 731 18.2 21.3 24.5 27.8 31.2 39 / 93 41 / 93 42 / 93 42 / 94 43 / 94 666 690 713 736 760 21.2 24.5 27.9 31.3 34.9 44 / 94 44 / 94 45 / 95 46 / 95 46 / 95 in Inches 3 560 12.1 21 / 83 577 13.7 23 / 84 595 15.5 25 / 85 616 17.5 27 / 87 637 19.8 30 / 88 658 22.4 33 / 90 680 25.1 35 / 91 703 28.1 38 / 92 730 31.3 41 / 93 756 34.8 44 / 94 wg 3.5 595 14.1 23 / 84 611 15.9 24 / 85 628 17.7 26 / 86 647 19.9 29 / 88 668 22.4 31 / 89 689 25.1 34 / 90 710 28.0 36 / 91 732 31.3 39 / 92 754 34.7 42 / 93 4 4.5 5 643 18.1 26 / 86 660 20.2 28 / 87 676 22.4 30 / 89 696 25.0 32 / 90 717 27.9 35 / 91 738 31.0 37 / 92 760 34.4 40 / 93 690 22.6 29 / 88 706 25.0 31 / 89 724 27.7 33 / 90 744 30.7 36 / 91 765 34.0 38 / 92 718 25.2 31 / 89 734 27.7 32 / 90 751 30.4 34 / 91 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance only. 60 100 SWB-349-AF - Belt Drive Series 300 805⁄16 6 5 (1303) (1313) 1085⁄16 55 (2751) (1397) 861⁄8 31⁄2 57 (2188) (89) 6 2 3 4 5 72 42 2 n 67 Do 5 1 4 73 ⁄16 (1875) 781⁄2 (1994) 5 48 2 363⁄4 (933) 3 61 4 7½ 53 541⁄2 (1384) 583⁄8 (1483) 8 4 780 (1448) 10 10 Static Pressure (in. wg) 5111⁄16 Static Pressure (Pa x 100) 51 ⁄16 RPM HP Density 0.075 lb/ft3 yst em cur ve (119) 12 5 20 15 is s (984) the lef to f th (970) 14 o 411⁄16 ot se lec tt 383⁄4 40 (894) 383⁄16 30 353⁄16 25 (2040) 13 0 Wheel Diameter = 49 (1245) Shaft Diameter = 27⁄16 (62) Outlet Area = 13.8 ft2 (1.28 m 2 ) ^Approximate Unit Weight = 2298 lb. (1045 kg) All dimensions in inches (millimeters) For additional discharge positions see page 15 ^Weight shown includes largest cataloged Open Drip Proof motor and weatherhood 0 0 10 0 20 20 30 Volume (cfm X 1000) 40 40 50 60 80 Volume (m3/hr x 1000) Maximum BHP at a given RPM = (RPM/248)3 (Maximum KW at a given RPM = (RPM/273)3) Maximum RPM = 780 Tip Speed (ft/min.) = RPM x 12.83 (Tip Speed (m/s) = RPM x 0.0652) Maximum Motor Frame Size = 324T SWB-349-AF CFM OV 20000 1449 22000 1594 24000 1739 26000 1884 28000 2028 30000 2173 32000 2318 34000 2463 36000 2608 38000 2753 40000 2898 RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA RPM BHP Sones / LwiA Static Pressure 0.5 1 1.5 2 2.5 365 413 457 499 537 2.93 4.56 6.27 7.99 9.74 12.4 / 73 13.7 / 75 15.5 / 77 17.5 / 79 18.9 / 80 391 437 478 517 555 3.54 5.31 7.13 9.06 10.9 13.7 / 75 15.2 / 76 17.1 / 78 18.8 / 80 20 / 81 419 461 501 537 572 4.24 6.18 8.11 10.2 12.3 15.6 / 77 17 / 78 18.9 / 80 20 / 81 21 / 82 448 486 524 559 592 5.04 7.10 9.20 11.4 13.6 17.7 / 79 19.1 / 80 20 / 81 22 / 82 23 / 83 477 512 547 581 613 5.96 8.14 10.4 12.7 15.1 20 / 81 21 / 82 22 / 82 24 / 83 25 / 84 506 539 572 604 635 7.00 9.30 11.8 14.2 16.6 23 / 83 23 / 83 24 / 84 26 / 85 27 / 86 536 565 597 628 658 8.17 10.6 13.2 15.8 18.3 25 / 85 26 / 85 27 / 86 28 / 86 30 / 87 566 594 623 652 681 9.48 12.0 14.7 17.5 20.2 27 / 86 28 / 87 29 / 87 31 / 88 32 / 88 596 623 650 678 705 10.9 13.6 16.4 19.3 22.3 30 / 88 31 / 88 32 / 89 33 / 89 33 / 89 626 652 676 703 729 12.5 15.4 18.3 21.3 24.5 33 / 89 34 / 90 35 / 90 35 / 90 34 / 90 656 681 704 730 754 14.3 17.3 20.3 23.5 26.7 36 / 91 37 / 91 36 / 91 36 / 91 36 / 91 in Inches wg 3 3.5 589 12.9 21 / 82 607 14.3 23 / 83 624 15.9 24 / 84 644 17.5 26 / 85 665 19.2 29 / 87 686 21.0 30 / 87 709 23.0 32 / 88 732 25.2 33 / 89 755 27.5 34 / 90 779 30.0 36 / 91 639 16.4 24 / 84 656 18.1 26 / 85 673 19.9 28 / 86 693 21.8 29 / 87 714 23.8 30 / 88 735 25.9 32 / 89 757 28.1 33 / 89 4 4.5 5 686 20.4 27 / 85 703 22.3 28 / 86 721 24.4 29 / 87 740 26.6 31 / 88 761 28.8 32 / 89 714 22.7 27 / 86 731 24.7 28 / 87 748 27.0 30 / 87 766 29.3 31 / 88 757 27.2 29 / 87 775 29.6 30 / 88 Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (Bhp) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels and inlet hemispherical sone levels for installation type B: Free inlet, Ducted outlet, calculated per AMCA Standard 301. The AMCA Certified Ratings Seal applies to air performance and LwiA values only. 65 Page Header Specifications Model SFD Direct Drive Utility Fans Supply, exhaust or return air fans shall be of the direct drive utility fan type, in AMCA Arrangement 4 with a singlewidth, single-inlet housing, in clockwise or counterclockwise rotation as specified. The housing shall be constructed of heavy-gauge galvanized steel with lock formed seams permitting no air leakage. The housing shall be easily rotated in the field to any of the eight standard discharge positions. Housing supports and drive frame shall be constructed of heavy-gauge galvanized steel to minimize vibration and rigidly support the motor and wheel. The fan wheel shall be of the forward-curved type and shall be constructed of heavy-gauge aluminum. Wheels shall be statically and dynamically balanced. The wheel cone and fan inlet cone shall be carefully matched for maximum performance and operating efficiency. Motors shall be heavy-duty ball bearing type matched to the fan load and furnished at the specified voltage, phase and enclosure. All fans shall bear the AMCA Air Performance seal. Utility fans shall be model SFD (with forwardcurved wheels) as manufactured by Greenheck Fan Corporation of Schofield, Wisconsin, USA. Model SWB Series 100, 200 and 300 Belt Drive Utility Fans Supply, exhaust and return air fans shall be of the belt-driven utility fan type in AMCA Arrangement 10 with a singlewidth, single-inlet housing, in clockwise or counterclockwise rotation as specified. The housing shall be constructed of heavygauge galvanized steel on Series 100 Series 200 Series 100 Series 300 models and includes an airtight lock seam. Series 200 and 300 models shall have a heavyWheels shall be statically and dynamically balanced. gauge painted steel housing or optional aluminum The wheel cone and fan inlet cone shall be carefully housing on Series 200. Housing shall have an airtight matched for maximum performance and operating lock seam or optional welded seam. The housing shall efficiency. be field rotatable to any of the eight standard discharge positions. To prevent vibration and to rigidly support Motors shall be heavy-duty ball bearing type matched the shaft and bearings, Series 100 and 200 drive frame to the fan load and furnished at the specified voltage, and bearing supports shall be constructed of welded phase and enclosure. The fan shaft shall be ground and steel members coated with Permatector™ and Series polished solid steel mounted in heavy-duty pillow block 300 shall be constructed of reinforced heavy-gauge ball bearings. Bearings shall be selected for a minimum galvanized steel. L10 life in excess of 100,000 hours (L50 average life of 500,000 hours) at maximum cataloged operating speed. The fan wheel shall be of the non-overloading Drives shall be sized for a minimum of 150% of driven backward-inclined, centrifugal type. The fan wheel shall horsepower. Pulleys shall be of the fully machined cast be constructed of heavy-gauge aluminum on Series iron type, keyed and securely attached to the fan and 200 fans sizes 206-210 and all Series 100 fans. Series motor shafts. The motor pulley shall be adjustable for 200 and 300 wheels shall be constructed of heavyfinal system balancing for applications with 10 hp or gauge steel with optional aluminum on Series 200 fans less motors. size 212 and larger and all Series 300 sizes. Series 300-AF fans shall have an aluminum backward-inclined airfoil wheel. 66 All fans shall bear the AMCA Air Performance seal. Utility fans shall be model SWB (with backwardinclined wheels) as manufactured by Greenheck Fan Corporation in Schofield, Wisconsin, USA. SWB- Specifications Series Model SFB Belt Drive Utility Fans Supply, exhaust and return air fans shall be of the belt driven utility fan type in AMCA Arrangement 10 with a single-width, singleinlet housing, in clockwise or counterclockwise rotation as specified. The housing shall be constructed of heavygauge steel with airtight lock formed seams. The housing shall be easily rotated in the field to any of the eight standard discharge positions. Housing supports and drive frame shall be constructed of welded steel members to prevent vibration and to rigidly support the shaft and bearings. Model SFB fan wheels shall be of the forward-curved type, constructed of heavy-gauge steel with uniform stamped steel blades. Model SWD Direct Drive Utility Fans Supply, exhaust, and return air fans shall be of the direct-driven utility fan type in AMCA Arrangement 4 with a single width, single inlet housing, in clockwise or counterclockwise rotation as specified. The housing shall be constructed of galvanized steel, painted steel, or aluminum with welded or air tight lock formed seams. Housings shall be field rotatable to any of the eight standard discharge positions. Housing supports and drive frame shall be constructed of heavy-gauge galvanized or painted steel to minimize vibration and rigidly support the motor and wheel. The fan wheel shall be of the non-overloading backward inclined, centrifugal fan type and constructed of heavy-gauge aluminum. Wheels shall be statically and dynamically balanced. The wheel cone and fan Wheels shall be statically and dynamically balanced. The wheel cone and fan inlet cone shall be carefully matched for maximum performance and operating efficiency. Motors shall be heavy-duty, ball bearing type, matched to the fan load and furnished at the specified voltage, phase and enclosure. The fan shaft shall be ground and polished solid steel mounted in heavy-duty, sealed, pillow block ball bearings. Bearings shall be selected for a minimum L10 life in excess of 100,000 hours (L50 average of 500,000 hours) at maximum cataloged operating speed. Drives shall be sized for a minimum of 150% of driven horsepower. Pulleys shall be of the fully machined cast iron type, keyed and securely attached to the fan and motor shafts. The motor pulley shall be adjustable for final system balancing. All fans shall bear the AMCA Air Performance seal. Utility fans shall be model SFB (with forwardcurved wheels) as manufactured by Greenheck Fan Corporation of Schofield, Wisconsin, USA. inlet cone shall be carefully matched for maximum performance and operating efficiency. The motor shall be an electronic commutation (EC) type motor specifically designed for fan applications. AC induction type motors are not acceptable. Other examples of unacceptable motors are: Shaded Pole, Permanent Split Capacitor (PSC), Split Phase, Capacitor Start and 3 phase induction type motors. Motors shall be permanently lubricated with heavy-duty ball bearings to match the fan load and prewired to the specific voltage and phase. The motor shall be controllable down to 20% of full speed (80% turndown). Speed shall be controlled by either potentiometer dial mounted on the motor or by a 0-10 VDC signal. The motor shall be a minimum of 85% efficient at all speeds. Fan performance shall be based on tests conducted in accordance with AMCA Standard 210 for air moving devices, and fans shall be licensed to bear the AMCA Certified Ratings Seal for air performance. Utility fans shall be model SWD (with backward inclined wheels) as manufactured by Greenheck Fan Corporation in Schofield, Wisconsin, USA. 67 Vari-Green® Specifications Vari-Green® Motor Motor to be an electronic commutation (EC) motor specifically designed for fan applications. AC induction type motors are not acceptable. Examples of unacceptable motors are: Shaded Pole, Permanent Split Capacitor (PSC), Split Phase, Capacitor Start and 3 phase induction type motors. Motors shall be permanently lubricated with heavy-duty ball bearings to match the fan load and prewired to the specific voltage and phase. Internal motor circuitry shall convert AC power supplied to the fan to DC power to operate the motor. Motor shall be speed controllable down to 20% of full speed (80% turndown). Speed shall be controlled by either a potentiometer dial mounted on the motor or by a 0-10 VDC signal. Motor shall be a minimum of 85% efficient at all speeds. Vari-Green® Controls Constant Pressure Greenheck’s Constant Pressure system shall be a complete package designed to regulate fan speed based on demand while maintaining a constant static pressure. System shall include fan with Vari-Green Motor, Vari-Green Constant Pressure control, transformer, and pressure tap. Vari-Green Constant Pressure control shall have the transducer integrated with a touch button control panel. Control shall have a run mode and a program mode preventing unwanted changes when in run mode. Transformer shall be factory-supplied to provide power to the Vari-Green Constant Pressure controller. System shall include a self-sealing aluminum pressure tube with ¼-inch connection. Fan shall be centrifugal direct drive type in upblast, downblast, or inline configuration with controllable EC Vari-Green motor. Remote Dial Remote dial shall be a Vari-Green control specifically designed to provide 0-10 VDC signal to Greenheck’s Vari-Green Motor. 2-Speed 2-Speed control shall be a Vari-Green Control specifically designed to allow the Vari-Green Motor to operate at two distinct speeds. 2-Speed Control shall include two dials that may be set at any point between 0 and 10 VDC and an integral transformer capable of reducing 115/230 volt AC power to 24 volt AC power. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com 00.F&V.1020 R3 1-2014 SP Copyright © 2014 Greenheck Fan Corp.
© Copyright 2026 Paperzz