Schedule 5—Boundary Clearances SCHEDULE 5⎯BOUNDARY CLEARANCES FOR BUILDINGS AND STRUCTURES (1) The boundary clearances in Table 1 below apply as default provisions unless other provisions are specified elsewhere in this planning scheme. (2) However, section 1 does not apply to— (a) a screen or fence not more than 2 m in height if not on a corner lot; or (b) a structure, other than a pool, that is not part of a building and that is not more than 1 m in height. Table 1 (1) Road Column 1 Column 2 Boundary Dimension of clearance boundary 1 (1) Diagram A 1 (a) There are no requirements for structures, other than swimming pools, less than 1m above natural ground. (b) For a dwelling, garage or a carport the minimum road setback is 6m. (c) No building or structure over 2m high is built within a 9m by 9m truncation at the corner of the 2 road frontages (Refer to Diagram A). (d) For open carports, the minimum road setback may be less than required by (1)(b) or (c) above if – (i) the maximum width of the carport does not exceed 3m, excluding an eaves overhang of 600mm maximum; and (ii) the building height of the carport does not exceed 4.5m. The road setback distances contained in this Schedule apply regardless of the existence of any Access Restriction Strip. May 2007 SCH5-1 Schedule 5—Boundary Clearances Column 1 Column 2 Boundary Dimension of clearance (e) For structures the minimum road setbacks are as for (1)(b), (c), and (d) above, except for – (i) swimming pools where the minimum distance from the water to the road frontage is – (A) where the vertical distance to the coping above the finished ground level is not more than 1.2m – a setback of 1.5m; or (B) where a solid wall at least 1.5m high above the coping is constructed between the water and the road frontage – no setback requirement; and (ii) screens/fences not more than 2m high; and (iii) roofed gatehouses and arches having – (A) a maximum area of 4m2; and (B) not more than 2m wide elevation to the street; and (C) not more than 3m in height. (2) Side and rear boundaries (a) Usual standard if the maximum height of the building or structure is— (i) (b) not less than 1.5m (ii) between 4.5m and 7.5m not less than 2.0m (iii) greater than 7.5m not less than 2.0m plus 0.5m for every 3 m or part of 3m by which the height is greater than 7.5m (iv) stepped the boundary clearance corresponding to the height of each step Exception for narrow rectangular or near rectangular lots if the maximum height of the building or structure is 4.5 m or less and the road frontage is— (i) SCH5-2 4.5m or less 15.001—15.500m 1.5m (ii) 14.501—15.000m 1.425m (iii) 14.001—14.500m 1.35m (iv) 13.501—14.000m 1.275m (v) 13.001—13.500m 1.2m (vi) 12.501—13.000m 1.125m (vii) 12.001—12.500m 1.05m (viii) 11.501—12.000m 0.975m (ix) 11.001—11.500m 0.9m (x) 10.501—11.000m 0.825m (xi) 10.500m or less 0.75m May 2007 Schedule 5—Boundary Clearances (c) Column 1 Column 2 Boundary Dimension of clearance Exception for narrow rectangular or near rectangular lots if the maximum height of the building or structure is between 4.5 m and 7.5 m and the road frontage is— (i) 15.001—15.500m 2.0m (ii) 14.501—15.000m 1.9m (iii) 14.001—14.500m 1.8m (iv) 13.501—14.000m 1.7m (v) 13.001—13.500m 1.6m (vi) 12.501—13.000m 1.5m (vii) 12.001—12.500m 1.4m (viii) 11.501—12.000m 1.3m (ix) 11.001—11.500m 1.2m (x) 10.501—11.000m 1.1m (xi) 10.500m or less 1.0m (d) Exception for narrow rectangular or near rectangular lots if the maximum height of the building or structure is greater than 7.5m and the road frontage is 15.5m or less not less than 2.0m plus 0.5m for every 3m or part of 3m by which the height is greater than 7.5m (e) Exception for private garages, carport, shed or the like if— up to the boundary (i) the maximum height of the building is not more than 4.5m and the mean height is not more than 3.5m; and NOTE 1 Mean height is the total elevational area of the building divided by the horizontal length of the building facing the boundary. (f) (g) (ii) the total length of all buildings facing and within the usual clearance of the relevant boundary is not greater than 9m; and (iii) the building is at least 1.5m from the window of each habitable room in an existing building on an adjoining lot. Exception for a pergola or other structure if — (i) not enclosed or roofed; and (ii) not more than 2.4m in height at the boundary; and (iii) primarily ornamental or for horticultural purposes. Exception for rainwater tanks if: up to the boundary up to the boundary (i) their height above natural ground level does not exceed 3m; and (ii) the diameter of any circular type tank does not exceed 3.5m, or, if the tank is not circular in nature, no side of the tank facing the boundary line is longer than 5m. May 2007 SCH5-3
© Copyright 2026 Paperzz