Introduction This document describes the Narrow band polling protocol parameter configurations in Psion Teklogix devices. Background The protocol timing settings of the RA1001 are identical to those of the TRX7370 radio. These settings are different from the much older TRX73xx radios. As a result, using the same SYCD settings on a 7030 (with a TRX73xx radio) and a 7035/7530 (with a TRX7370/RA1001 radio) will produce different behaviour. The following tables provide recommended settings for various configurations. These configurations have been tested using the following base station polling configuration: 4 poll windows window size = 32 free window factor = 0 message mode limit = 0 Using this configuration, the base station will, on average, generate the longest poll cycles. Thus, the terminal poll timeout values represent the maximum setting of poll timeout appropriate for a given system. Terminology Each generation of terminals will be identified by the hand held terminal model number. The protocol timing is consistent within each generation. The "7030" generation represents the 7030, 8055 and 8060 terminals. The "7035" generation represents the 7035, 8255, and 8260 terminals. The "7530" generation represents the 7530, 8525 and 8530 terminals. Systems that consist of RA1001 and TRX7370 radios will be identified as "RA1001/TRX7370 modern" systems. Systems that consist of RA1001/TRX7370 and the older TRX73xx will be identified as "TRX73xx/RA1001/TRX7370 legacy" systems. TRX7370/RA1001 Preamble Configuration The configurations shown in the following tables are broken into two categories: TRX73xx/RA1001/TRX7370 legacy systems and RA1001/TRX7370 modern systems. For legacy systems, the RA1001/TRX7370 transmission preamble must be configured to be backwards compatible with the older TRX73xx radios. While a RA1001/TRX7370 system will function properly using a TRX73xx preamble, it is possible to improve performance by using a preamble optimized for the RA1001/TRX7370. As a rule of thumb for configuration, if it is unclear whether or not a RA1001/TRX7370 product will be used with older TRX73xx radios always configure the RA1001/TRX7370 to use a TRX73xx preamble. For 2-level modulation, the preamble consists of the transmission of a number of DEL characters. For the 7035 generation of terminals, the number of DELs for 2-level modulation is configured using the RTEST 'dt' command. For the 7530 generation of terminals, the number of DELs for 2level modulation is configured in the Narrow Band control panel. Press the "Advanced" button in the "Radio" tab the to access this configuration. For 4-level modulation, the preamble consists of the transmission of a period of unmodulated carrier followed by a number of DEL characters. For the 7035 generation of terminals, the unmodulated carrier duration and number of DELs are configured using the RTEST 'txd' and 'df' commands respectively. For the 7530 generation of terminals, the number of DELs for 4-level modulation is configured in the Narrow Band control panel. Press the "Advanced" button in the "Radio" tab the to access this configuration. The following table shows the recommended preamble settings for both 2- and 4-level modulations. TRX7370 TRX73xx/RA1001/TRX7370 RA1001\TRX7370 Preamble Settings Legacy System Modern System # of DELs - 2-level 10 4 # of DELs - 4-level 6 4 unmodulated carrier 11 duration - 4-level 0 TRX73xx, RA1001, TRX7370 Legacy Systems Important: These configurations are for TRX73xx/RA1001/TRX7370 systems. For these systems, the TRX7370s and RA1001s must be configured to use a transmit preamble that is backwards compatible with older TRX73xx radios. Click [here] for more detail. Configuration 1 - 9140, 9150 Base Station, 7030, 7035, 7530 4-Level 19200 Baud 9140 (TRX7355) 9150 (TRX7370) 9160 (RA1001) 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 15 Txon = 24 Rtxon = 36 Sycd = 31 Rtxon = 40 Collision Tmo = 20 1 Sycd = TBD Rtxon = TBD Collision Tmo = TBD 1 Sycd = 14 Txon = 26 Poll Timeout = 20 Tx off Time = 2 Tx off Wait = 8 Sycd = 17 Window Delay = 20 Poll Timeout = 20 9160 (RA1001) 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) 4-Level 9600 Baud 9140 (TRX7355) 9150 (TRX7370) Sycd = 13 Txon = 23 Rtxon = 20 Sycd = 23 Rtxon = 19 Collision Tmo = 26 1 Sycd = TBD Rtxon = TBD Collision Tmo = TBD 1 Sycd = 12 Txon = 14 Poll Timeout = 25 Tx off Time = 4 Tx off Wait = 2 Sycd = 17 Window Delay = 23 Poll Timeout = 25 2-Level 9600 Baud 9140 (TRX7355) 9150 (TRX7370) 9160 (RA1001) 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 15 Txon = 18 Rtxon = 14 Sycd = 23 Rtxon = 13 Collision Tmo = 17 1 Sycd = TBD Rtxon = TBD Collision Tmo = TBD 1 Sycd = 10 Txon = 15 Poll Timeout = 22 Tx off Time = 0 Tx off Wait = 0 Sycd = 17 Window Delay = 19 Poll Timeout = 22 2-Level 4800 Baud 9140 (TRX7355) 9150 (TRX7370) 9160 (RA1001) 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 10 Txon = 8 Rtxon = 8 Sycd = 17 Rtxon = 8 Collision Tmo = 32 1 Sycd = TBD Rtxon = TBD Collision Tmo = TBD 1 Sycd = 9 Txon = 8 Poll Timeout = 37 Tx off Time = 0 Tx off Wait = 0 Sycd = 25 Window Delay = 23 Poll Timeout = 37 Configuration 2 - 9130 RRM, 7030, 7035, 7530 4-Level 19200 Baud 9300 (9130-TRX7355) 7030 (TRX7355) Sycd = TBD Txon = TBD Rtxon = TBD 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = TBD Txon = TBD Window Delay = TBD Poll Timeout = TBD 2 Poll Timeout = TBD 2 Tx off Time = TBD Tx off Wait = TBD 4-Level 9600 Baud 9300 (9130-TRX7355) 7030 (TRX7355) Sycd = TBD Txon = TBD Rtxon = TBD 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = TBD Txon = TBD Window Delay = TBD Poll Timeout = TBD 2 Poll Timeout = TBD 2 Tx off Time = TBD Tx off Wait = TBD 2-Level 9600 Baud 9300 (9130-TRX7355) 7030 (TRX7355) Sycd = 22 Txon = 24 Rtxon = 14 7035 (TRX7370) 7530 (RA1001) Sycd = 8 Sycd = 12 Txon = 14 Window Delay = 19 Poll Timeout = 22 2 Poll Timeout = 22 2 2-Level 4800 Baud 9300 (9130-TRX7355) 7030 (TRX7355) Sycd = 17 Txon = 8 Rtxon = 6 7035 (TRX7370) 7530 (RA1001) Sycd = 4 Sycd = 9 Txon = 6 Window Delay = 21 Poll Timeout = 30 2 Poll Timeout = 30 2 Note: In the 7530 generation, the above settings are the default values in the Narrow Band Control Panel. Configuration 3 - Network Timeplexed 9150, 7030, 7035, 7530 4-Level 19200 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = TBD Rtxon = 8 Collision Tmo = 32 1 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = 9 Sycd = 25 Rtxon = TBD Txon = 8 Window Delay = 23 Collision Tmo = TBD 1 Poll Timeout = 37 2 Poll Timeout = 37 2 Tx off Time = 0 Tx off Wait = 0 4-Level 9600 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 28 Rtxon = 13 Collision Tmo = 26 1 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 28 Sycd = 12 Sycd = 22 Rtxon = 13 Txon = 14 Window Delay = 19 Collision Tmo = 26 1 Poll Timeout = 20 2 Poll Timeout = 22 2 Tx off Time = 4 Tx off Wait = 2 2-Level 9600 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 28 Rtxon = 13 Collision Tmo = 17 1 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 28 Sycd = 8 Sycd = 17 Rtxon = 13 Txon = 14 Window Delay = 19 Collision Tmo = 17 1 Poll Timeout = 20 2 Poll Timeout = 22 2 Tx off Time = 0 Tx off Wait = 0 2-Level 4800 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 17 Rtxon = 9 Collision Tmo = 32 1 7030 (TRX7355) 7035 (TRX7370) 7530 (RA1001) Sycd = 17 Sycd = 8 Sycd = 24 Rtxon = 9 Txon = 9 Window Delay = 23 Collision Tmo = 32 1 Poll Timeout = 40 2 Poll Timeout = 40 2 Tx off Time = 0 Tx off Wait = 0 RA1001, TRX7370 Modern Systems Important: These configurations are for RA1001/TRX7370 systems. For these systems, the TRX7370s and RA1001s must be configured to use a transmit preamble optimized for a RA1001/TRX7370 system. Click here for more detail. Configuration 1 - 9150 Base Station, 7035, 7530 4-Level 19200 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 30 Rtxon = 7 Collision Tmo = 20 1 7035 (TRX7370) 7530 (RA1001) Sycd = 30 Sycd = 12 Rtxon = 7 Window Delay = 6 Collision Tmo = 30 1 Poll Timeout = 14 4-Level 9600 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 18 Rtxon = 4 Collision Tmo = 26 1 2-Level 9600 Baud 7035 (TRX7370) 7530 (RA1001) Sycd = 18 Sycd = 13 Rtxon = 4 Window Delay = 9 Collision Tmo = 30 1 Poll Timeout = 23 Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 18 Rtxon = 4 Collision Tmo = 17 1 7035 (TRX7370) 7530 (RA1001) Sycd = 18 Sycd = 13 Rtxon = 4 Window Delay = 9 Collision Tmo = 17 1 Poll Timeout = 23 2-Level 4800 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 10 Rtxon = 3 Collision Tmo = 32 1 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = 13 Rtxon = TBD Window Delay = 17 3 Collision Tmo = TBD 1 Poll Timeout = 42 Configuration 2 - Network Timeplexed 9150, 7035, 7530 4-Level 19200 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = TBD Rtxon = TBD Collision Tmo = 20 1 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = TBD Rtxon = TBD Window Delay = TBD Collision Tmo = TBD 1 Poll Timeout = TBD 2 4-Level 9600 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = TBD Rtxon = TBD Collision Tmo = 26 1 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = TBD Rtxon = TBD Window Delay = TBD Collision Tmo = TBD 1 Poll Timeout = TBD 2 2-Level 9600 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = 28 Rtxon = 13 Collision Tmo = 17 1 7035 (TRX7370) 7530 (RA1001) Sycd = 28 Sycd = 17 Rtxon = 13 Window Delay = 19 Collision Tmo = 17 1 Poll Timeout = 22 2 2-Level 4800 Baud Controller 9150 (TRX7370) 9160 (RA1001) Sycd = TBD Rtxon = TBD Collision Tmo = 32 1 7035 (TRX7370) 7530 (RA1001) Sycd = TBD Sycd = TBD Rtxon = TBD Window Delay = TBD Collision Tmo = TBD 1 Poll Timeout = TBD 2 Notes 1. The RA1001/TRX7370 radios provide a collision detection function. A TRX7370 or RA1001 will signal a collision if carrier is asserted for a specified period of time without a SOH character being decoded. This period of time is called the collision timeout and may be configured with the RTEST 'cl' command. The "collision timeout" values in the above tables for the 9150 are the recommended settings for this value. It should be noted that the 9150 has a "Collision Size" parameter in its list of Polling Protocol parameters. Since the functionality controlled by this parameter is superseded by the RA1001/TRX7370 collision timeout, it does not require setting and should be left at its default value. 2. The Poll Timeout listed for Timeplexed systems is for configurations with one RRM (serial or network) in a group. If more than one RRM exists in a group the Poll Timeout value should be multiplied by total number of RRMs in the group. 3. The Window Delay for a 4800 baud RA1001\TRX7370 system is larger than necessary in order to comply with a configuration restriction of the 9150. For this configuration the terminal should operate fine with a setting of 10-12. However, the minimum setting of RTXON in the 9150 is 3 which prohibits the use of the more optimized settings.
© Copyright 2025 Paperzz