HOME Active Infrared (through-beam) Counter Version 3.0 To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar. To advance the slides backward, use one of the following keys: PageUp, Left Arrow (), Up Arrow (), or BackSpace. To exit the presentation at any time, press the escape (Esc) key or click the yellow Exit button at the bottom right of the screen. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME Active Infrared (through-beam) Counter Version 3.0 To advance the slides forward, click the left mouse button or use one of the following keys: PageDown, Right Arrow (), Down Arrow (), or SpaceBar. To advance the slides backward, use one of the following directly keys: PageUp, Left Arrow You (),can Up go Arrow (), to or BackSpace. topics by selecting then clicking on a To exit the presentation at any time, press the escape (Esc) topic atatthe key or click the yellow Exit button the bottom bottom of right of the screen. the screen. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME Active Infrared (through-beam) Counter Version 3.0 TrailMaster Model TM1550 (with 4K Memory) TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TrailMaster HOME Model TM1550 Red alignment indicator light Power Switch Press TIME SET and SET UP buttons simultaneously. Sight line for alignment with transmitter Data Port Camera Connector (for optional accessory) (for optional data collector unit) TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA Power Switch TM1550—Installation Instructions HOME Recommended Tools: Screwdriver, (Philips head) Step 1. In forested locations, select a site along the trail with up to 10” diameter trees on both sides of the trail. The extra set(s) of straps (included with your counter) can be used to lengthen the straps, thus allowing the attachment to large diameter trees. Step 2. Mount the Receiver unit (with nylon straps, provided on the unit) to one tree, with the sensor (located on the right side of the unit) facing the opposite tree. (Note, use the alignment sighting line to aim the receiver’s sensor in the direction of the opposite tree where the Transmitter unit will be mounted.) TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TM1550—Installation Instructions HOME Step 3. Turn “on” the Receiver unit’s power switch and press the “Set Up” button on the front of the unit. Step 4. Mount the Transmitter unit on the opposite tree (up to 150 feet away). Note, the sensor of the transmitter is located on the front face of the unit. This sensor should be aiming back towards the Receiver unit. Turn the power switch on. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TM1550—Installation Instructions HOME Step 5. At this time, you should notice the “red” alignment indicator on the Receiver unit blinking indicating the transmitter and receiver units are initially aligned. Step 6. Tighten all mounting straps on each unit. Then, take several passes back and forth on the trail to verify that the counter is counting. If not, reposition the Receiver unit to align the sensor’s beam. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting HOME This section will illustrate how to set up the TIME and DATE function for the receiver unit. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting mm.dd hh:mm xx press press HOME …the display will toggle between time and date for several seconds, then display the total counts. Turn the receiver unit on. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting hh:mm press and hold …the display will show the time with the hours blinking. next, hold down the TIME SET button for five seconds. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting hh:mm press …the hour number will advance from 0 to 24 each time the R/O ADV button is pressed. press the R/O ADV button to advance the hour (0-24). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting hh:mm press once HOME …the display will show the time with the minutes blinking. To change the minutes, press the TIME SET button once. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting hh:mm press …the minutes number will advance from 01 to 59 each time the R/O ADV button is pressed. press the R/O ADV button to advance the minutes (01-59). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting yr xx press once HOME …the display will show the year with the second to last digit of the year blinking. To change the year, press the TIME SET button once. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting yr 0x press …the number will advance each time the R/O ADV button is pressed. press the R/O ADV button to advance the number (0-9). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting yr 0x press once …the display will show the year with the last digit of the year blinking. press the TIME SET button again to change the last digit of the year. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting yr 04 press HOME …the number will advance each time the R/O ADV button is pressed. press the R/O ADV button to advance the number (0-9). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting mm.dd press once …the display will show the month and day. The month number will be blinking. To change the month and day, press the TIME SET button once. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting 7.dd press HOME …the month will advance each time the R/O ADV button is pressed. press the R/O ADV button to advance the number (1-12). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting 7.dd press once …the display will show the month and day. The date number will be blinking. To change the day, press the TIME SET button once. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME TIME and DATE Setting 7.14 press HOME …the day will advance each time the R/O ADV button is pressed. press the R/O ADV button to advance the number (1-31). TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TIME and DATE Setting 7.14 press the TIME SET button when done. press TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME Changing PULSE RATE HOME 2 This section will illustrate how to adjust the pulse rate function for the receiver unit. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA Changing PULSE RATE -P 2 HOME …the display will show the pulse rate - P and blinking number from 1 through 30. press the TIME SET button twice. press twice TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA Changing PULSE RATE -P 5 press HOME …the display will show the pulse rate - P and blinking number from 1 through 30. press the R/O ADV button to change the rate from 1 to 30. Tip: use 5 for pedestrians or 2 for vehicles. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA HOME 3867 This section will illustrate how to set clear or “zero” the counter. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA HOME S. uP “Resetting the Counter” Press TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA HOME c lr “Resetting the Counter” Press TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA HOME 0 “Resetting the Counter” Press TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA CLEARING EVENT DATA 0 The counter is now ready to begin counting. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME READ OUT of EVENT DATA HOME 386 This section will illustrate how read out the event data from the receiver unit. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME READ OUT of EVENT DATA 386 Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started Time 12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 To extract your collected date/timestamped data from the counter, do the following... 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA Log noXX Recorded Counts READ OUT of EVENT DATA 386 Note, the number displayed is the total counts (cumulative) for the entire sampling period. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME READ OUT of EVENT DATA 386 Note, the number displayed is the total counts (cumulative) for the entire sampling period. To find out when these counts occurred, do the following . . . TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME READ OUT of EVENT DATA 12. 1 HOME …the date will appear (month.day) 1 Press here TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA READ OUT of EVENT DATA 15.31 HOME …the time will appear (hour.minute) 2 Press here again TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA READ OUT of EVENT DATA 1 3 Press here again HOME …the count will appear Note, the count displayed is a cumulative total of successive counts. TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA READ OUT of EVENT DATA Ehru HOME …when this message is displayed it indicates you have reached the end of the recorded counts. 4 Press here again TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME READ OUT of EVENT DATA You should be recording this information onto the form. The form enclosed with your shipment may be different from the one shown here. Traffic Counter Data Collection Sheet Sampling Location or Site Name: _______________ Counter brand and serial number or property number: ________________ Interval Setting: 1 hour Name of Data Collector: _________________ Date: _________________ Place a check in this column to denote time counter was started Time 12:00 a.m. (midnight) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 12:00 p.m. (noon) 12:30 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 7:30 8:00 8:30 9:00 9:30 10:00 10:30 11:00 11:30 TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA Log noXX Recorded Counts Operating Specs HOME TM1550 Four “C” Batteries (transmitter unit) power source Four “C” Batteries battery life 8 months weight & dimensions range (separation between transmitter and receiver) (receiver unit) 1 lb (receiver) 10 oz (transmitter) 150 ft. adjustable sensitivity (pulse rate) yes non-volatile data memory yes TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA TM1500—Product Service Information Goodson and Associates, Inc. 10614 Widmer Lenexa, KS 66215 Contact: Bill Goodson Phone: 913-345-8555 or 1-800-544-5415 Fax: 913/345-8272 Website: www.trailmaster.com TIME and DATE Setting CLEARING EVENT DATA Changing PULE RATE READ OUT of EVENT DATA HOME
© Copyright 2026 Paperzz