25.08.2005 / ES DIGIFORCE ® 9306 ? 25.08.2005 / ES DIGIFORCE ® 9306 25.08.2005 / ES DIGIFORCE ® 9306 25.08.2005 / ES DIGIFORCE ® 9306 The Strain-Gage Load Cell +U +F +Ua -Ua -U -F 25.08.2005 / ES DIGIFORCE ® 9306 Force - Calibration Scale Value Excitation 500 5 VN 4V 3V 2V 1V 0V N Output Cal. Value Signal 1,152 mV2,304 mV3,456 mV4,608 mV 1,152 5,760 mV/V mV 00mV/V mV 25.08.2005 / ES DIGIFORCE ® 9306 Force - Calibration PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION Y N AUS 0.000 N 500.0 N 0.000 mV/V 1.152 mV/V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Force - Calibration PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION Y N AUS 0.000 N 500.0 N 0.000 mV/V 1.152 mV/V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Force - Calibration Page 1 Page 2 25.08.2005 / ES CHANNEL STRAIN GAGE SENSITIV. UNIT NOM. RANGE USED RANGE LEVEL (EL) Y EXCI. 5 V 1.152 mV/V N 500.0 kN 500.0 kN 68.2 % NEXT PREVIOUS FILTER 50 Hz INVERT OFF LOW. SCAL 0.000 KN UPP. SCAL 500.0 KN LOW. CALVAL 0.000 mV/V UPP. CALVAL 1.152 mV/V CALCULATE SCALING DIGIFORCE ® 9306 Force - Calibration Page 1 Page 2 25.08.2005 / ES CHANNEL STRAIN GAGE SENSITIV. UNIT NOM. RANGE USED RANGE LEVEL (EL) Y EXCI. 5 V 1.152 mV/V N 500.0 kN 500.0 kN 68.2 % NEXT PREVIOUS FILTER 50 Hz INVERT OFF LOW. SCAL 0.000 KN UPP. SCAL 500.0 KN LOW. CALVAL 0.000 mV/V UPP. CALVAL 1.152 mV/V CALCULATE SCALING DIGIFORCE ® 9306 Force - Calibration Page 1 Page 2 25.08.2005 / ES CHANNEL STRAIN GAGE SENSITIV. UNIT NOM. RANGE USED RANGE LEVEL (EL) Y EXCI. 5 V 1.152 mV/V N 500.0 kN 500.0 kN 68.2 % NEXT PREVIOUS FILTER 50 Hz INVERT OFF LOW. SCAL 0.000 KN UPP. SCAL 500.0 KN LOW. CALVAL 0.000 mV/V UPP. CALVAL 1.152 mV/V CALCULATE SCALING DIGIFORCE ® 9306 25.08.2005 / ES DIGIFORCE ® 9306 Shunt Calibration (only 9306) +U +F +Ua -Ua RShunt -U -F 25.08.2005 / ES DIGIFORCE ® 9306 Shunt Calibration (only 9306) Upper Scale Value = 381,465 N = 25.08.2005 / ES Nominal Force x Calibration Step Upper Calibration Value 500 N x 0,8792 mV/V 1,1524 mV/V DIGIFORCE ® 9306 Shunt Calibration (only 9306) PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION Y N 100 k 0.000 N 381.5 N 0.000 mV/V 0.879 mV/V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Shunt Calibration (only 9306) PROGRAM 1 MENU 30 CALIBATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION Y N 100 k 0.000 N 381.5 N 0.000 mV/V 0.879 mV/V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Testing with Strain Gage Simulator Typ 9405 Polarity selection (for example for tensioncompression simulation) + Excitation Simulated sensor + output - Excitation Output selection 25.08.2005 / ES Simulated sensor - output DIGIFORCE ® 9306 Testing with Strain Gage Simulator Typ 9405 Output Selection Upper Scale Value 500 N 25.08.2005 / ES x x Upper Calibration Value 0,998 mV/V 1,152 mV/V = Display = 433,2 N DIGIFORCE ® 9306 Calibration with Reference Measurement Chain TRANSCAL 7280 und Load Cell 8524 25.08.2005 / ES DIGIFORCE ® 9306 Calibrating a Displacement Sensor 8713-25 25.08.2005 / ES DIGIFORCE ® 9306 Calibrating a Displacement Sensor PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION X mm AUS 0.000 mm 20.00 mm 0.316 V 4.128 V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Calibrating a Displacement Sensor CHANNEL POTI UNIT Page 1 Page 2 25.08.2005 / ES X mm NEXT PREVIOUS FILTER 50 Hz INVERTED OFF LOW. SCAL 0.000 mm UPP. SCAL 20.00 mm LOW. CALVAL 0.257 V UPP. CALVAL 5.000 V CALCULATE SCALING DIGIFORCE ® 9306 Calibrating a Displacement Sensor 20mm End Block 8713-25 25.08.2005 / ES DIGIFORCE ® 9306 Calibrating a Displacement Sensor PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION X mm AUS 0.000 mm 20.00 mm 0.316 V 4.128 V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Calibrating a Displacement Sensor PROGRAM 1 MENU 30 CALIBRATION CHANNEL UNIT SHUNT CALIBRATION LOWER SCALE VALUE UPPER SCALE VALUE LOWER CAL. VALUE UPPER CAL. VALUE DO CALIBRATION X mm AUS 0.000 mm 20.00 mm 0.316 V 4.128 V SELECT ITEM ENTER MEASURE F1 25.08.2005 / ES S_TEST F2 F3 HISTORY F4 DIGIFORCE ® 9306 Calibrating a Displacement Sensor CHANNEL POTI UNIT Page 1 Page 2 25.08.2005 / ES X mm NEXT PREVIOUS FILTER 50 Hz INVERTED OFF LOW. SCAL 0.000 mm UPP. SCAL 20.00 mm LOW. CALVAL 0.257 V UPP. CALVAL 4.075 V CALCULATE SCALING DIGIFORCE ® 9306 Calibrating a Displacement Sensor CHANNEL POTI UNIT Page 1 Page 2 25.08.2005 / ES X mm NEXT PREVIOUS FILTER 50 Hz INVERTED OFF LOW. SCAL 0.000 mm UPP. SCAL 20.00 mm LOW. CALVAL 0.257 V UPP. CALVAL 4.075 V CALCULATE SCALING DIGIFORCE ® 9306 Y = f (x) Channel Y Sampling controlled by X-Channel User-selectable sampling interval Channel X 25.08.2005 / ES DIGIFORCE ® 9306 Y = f (x,t) Channel Y Sampling controlled by time (t) User-selectable sampling interval Channel X 25.08.2005 / ES DIGIFORCE ® 9306 Y = f (t) Channel Y Sampling controlled by time (t) User-selectable sampling interval t 25.08.2005 / ES DIGIFORCE ® 9306 X = f (t) Channel X Sampling controlled by time (t) User-selectable sampling interval t 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Absolut 1 A A A 2 B B B 3 1 Pin always in same starting position 2 Work piece has negligible tolerances 3 Work piece support always at same height 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Absolut Channel Y Channel X Calibrated zero point of displ. sensor for measurement function y=f(x) or y=f(x,t), or START edge for y=f(t) 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Trigger 1 A A A 2 B B Part 1 B Part 2 Part 3 1 Press touches the part at different displacement positions (TRIGGER POINT) 2 25.08.2005 / ES Tolerances of part B would cause the press-fit curve to shift along the displacement axis DIGIFORCE ® 9306 Reference: Trigger Channel Y Trigger threshold Channel X X is set to zero when the trigger threshold is reached. The evalutation windows are now referenced to this dynamic zero point. 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Final Force / Blockwindow 1 A B A B A B 2 1 If the trigger point is not reproducible, neither TRIGGER Y nor ABSOLUTE reference are suitable 2 Reference point for the evaluation windows is here the lower dimension of the hole 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Final Force Channel Y Final Force Channel X X-Max as reference point 25.08.2005 / ES DIGIFORCE ® 9306 Reference: Blockwindow 1 Spread in values is cut off 2 Reference is the entry point to the lower edge of the block window or its imaginary extension Channel Y 1 2 Channel X X entry coordinate used as reference 25.08.2005 / ES DIGIFORCE ® 9306 External START ~ 2 ms 30 ... 150 ms Signal Source START PLC IO 9306 NIO 9306 READY 9306 25.08.2005 / ES DIGIFORCE ® 9306
© Copyright 2026 Paperzz