Sensors Magnetic and Electric Field Sensors for Natural-Source and Controlled-Source Electromagnetic Methods GEOPHYSICS telephone: +1 416.491.7340 fax: +1 416.491.7378 e-mail: [email protected] web: www.phoenix-geophysics.com Magnetic Induction Coils With Built-in Pre-amplifers 0 AMTC-30 for AMT, CSAMT, FDEM 82 cm x 6 cm dia., 3 kg 100 MV/nT 10 10 Amplitude Response -5 4 10 Log 10 -5 10 Frequency (Hz) Frequency range: 10 000 Hz to 0.1 Hz 180° 0° 90° Phase Response 0 10 500 mV/nT MTC-80H for MT 97 cm x 6 cm dia., 5 kg Amplitude Response -4 10 4 10 Log Frequency (Hz) 10 10 -5 Frequency range: 400 Hz to 10 000 seconds 90° 90° Phase Response 0 MTC-50H for MT 144 cm x 6 cm dia., 8.2 kg 500 mV/nT 10 10 Amplitude Response Frequency range: -5 10 4 Log 10 -5 10 Frequency (Hz) 400 Hz to 50 000 seconds 90° 90° Phase Response 101 Noise (nT/ Hz ) MTC-80H AMTC-30 10-7 10 4 Log10 Frequency (Hz) -5 10 Typical Spectral Plot of Sensor Noise New! MTC -150 Sensor Magnetic Field Sensor for Natural-Source and Controlled-Source Electromagnetic Methods New in 2015! MTC-150 Broadband Sensor Range: 10 000 Hz to 10 000 seconds Sensitivity: 25 mv/nT Output range: Fully differential 0 5 V Dimensions: 144 cm x 6 cm dia. Weight: 6 kg Operating: 30°C to +70°C Environmental: IP68 dust- and water-resistant Compatible with all Phoenix receivers (V8, MTU-A) 2 Log10 Gamma/Sqrt(Hz) Typical amplitude (natural spectrum and noise) and noise floor Natural field, broadband mode (2014/07) Noise floor, broadband mode 0 Natural field, AMT mode (2014/11) Noise floor, AMT mode -2 AMT mode -4 Broadband mode -6 4 2 0 -2 -4 -2 -4 Typical coherency between two sensors Coherency (Hxy) Log10 Frequency (Hz) 4 2 0 1.0 0.0 Ratio (Hx1, Hy1) Broadband mode AMT mode Coherency (Hx1, Hy1) Magnitude 100.0 mV/nT 1.5 Typical calibration curves 1.0 0.5 0 4 2 0 -2 -4 -2 -4 Log10 Frequency (Hz) Phase Degrees 90 0 -90 4 2 0 New! PE5 Electrode Long life: slow to dry, easily rehydrated Only 13 cm x 7.25 cm dia., 0.75 kg Flat response from DC to 10 000 Hz Low noise, low offset, low drift Porous ceramic contact surface and conductive slurry prevent polarization Heavy-duty PVC and ABS construction protects against foul weather and temperature variations when buried in the earth New! TEM-AL MulTEM Loop Only 3.2 kg; 55 cm x 53 cm x 6 cm Effective area: 100 m2 Built-in bubble level Bandwidth: 40 kHz, critically damped Low noise (4 x 10 7 nT/ Hz at 1 kHz) Anti-saturation circuitry Operating temperature: 40 to 50 °C Independent tests proved that the performance of the new Phoenix TEM-AL loop equals or surpasses the performance of previousgeneration loops (Phoenix or Geonics). The late-time response has been improved without compromising early-time response. The dramatic reduction in size and weight makes it easy to deploy multiple loops for up to three simultaneous EM measurements at the V8 receiver. AL-100, FDEM and TDEM/LoTEM Loops Various models available; please enquire for specifics
© Copyright 2026 Paperzz