Sensors Brochure 2015-10-16 let

Sensors
Magnetic and Electric Field Sensors for
Natural-Source and Controlled-Source
Electromagnetic Methods
GEOPHYSICS
telephone: +1 416.491.7340
fax: +1 416.491.7378
e-mail: [email protected]
web: www.phoenix-geophysics.com
Magnetic Induction Coils
With Built-in Pre-amplifers
0
AMTC-30 for AMT, CSAMT, FDEM
82 cm x 6 cm dia., 3 kg
100 MV/nT
10
10
Amplitude Response
-5
4
10
Log
10
-5
10
Frequency (Hz)
Frequency range:
10 000 Hz to 0.1 Hz
180°
0°
90°
Phase Response
0
10
500 mV/nT
MTC-80H for MT
97 cm x 6 cm dia., 5 kg
Amplitude Response
-4
10 4
10
Log Frequency (Hz)
10
10
-5
Frequency range:
400 Hz to 10 000 seconds
90°
90°
Phase Response
0
MTC-50H for MT
144 cm x 6 cm dia., 8.2 kg
500 mV/nT
10
10
Amplitude Response
Frequency range:
-5
10
4
Log
10
-5
10
Frequency (Hz)
400 Hz to 50 000 seconds
90°
90°
Phase Response
101
Noise (nT/ Hz )
MTC-80H
AMTC-30
10-7
10
4
Log10 Frequency (Hz)
-5
10
Typical Spectral Plot of
Sensor Noise
New!
MTC -150
Sensor
Magnetic Field Sensor for Natural-Source and
Controlled-Source Electromagnetic Methods
New in 2015! MTC-150 Broadband Sensor
Range: 10 000 Hz to 10 000 seconds
Sensitivity: 25 mv/nT
Output range: Fully differential 0 5 V
Dimensions: 144 cm x 6 cm dia.
Weight: 6 kg
Operating:
30°C to +70°C
Environmental: IP68 dust- and water-resistant
Compatible with all Phoenix receivers (V8, MTU-A)
2
Log10 Gamma/Sqrt(Hz)
Typical amplitude (natural
spectrum and noise) and
noise floor
Natural field, broadband mode (2014/07)
Noise floor, broadband mode
0
Natural field, AMT mode (2014/11)
Noise floor, AMT mode
-2
AMT mode
-4
Broadband mode
-6
4
2
0
-2
-4
-2
-4
Typical coherency
between two sensors
Coherency (Hxy)
Log10 Frequency (Hz)
4
2
0
1.0
0.0
Ratio (Hx1, Hy1)
Broadband mode
AMT mode
Coherency (Hx1, Hy1)
Magnitude
100.0 mV/nT
1.5
Typical calibration curves
1.0
0.5
0
4
2
0
-2
-4
-2
-4
Log10 Frequency (Hz)
Phase
Degrees
90
0
-90
4
2
0
New! PE5 Electrode
Long life: slow to dry, easily rehydrated
Only 13 cm x 7.25 cm dia., 0.75 kg
Flat response from DC to 10 000 Hz
Low noise, low offset, low drift
Porous ceramic contact surface and conductive slurry prevent
polarization
Heavy-duty PVC and ABS construction protects against foul
weather and temperature variations when buried in the earth
New! TEM-AL MulTEM Loop
Only 3.2 kg; 55 cm x 53 cm x 6 cm
Effective area: 100 m2
Built-in bubble level
Bandwidth: 40 kHz, critically damped
Low noise (4 x 10
7
nT/ Hz at 1 kHz)
Anti-saturation circuitry
Operating temperature: 40 to 50 °C
Independent tests proved that the performance of the new Phoenix
TEM-AL loop equals or surpasses the performance of previousgeneration loops (Phoenix or Geonics). The late-time response has
been improved without compromising early-time response. The
dramatic reduction in size and weight makes it easy to deploy multiple
loops for up to three simultaneous EM measurements at the V8
receiver.
AL-100, FDEM and TDEM/LoTEM Loops
Various models available; please enquire for specifics