C193-E029 U l tra H ig h P erformance Liq u i d C h ro m a t o g ra p h SPD-M30A Photodiode Array Detector The Shimadzu Nexera UHPLC system has evolved even further with the Nexera X2. Incorporating the new SPD-M30A photodiode array detector, this system provides the highest sensitivity and resolution under a variety of conditions, whether UHPLC or HPLC. Intelligence: The i -PDeA function separates co-eluted peaks, and enables the visualization of unseen peaks The new analysis function, i -PDeA (intelligent Peak Deconvolution Analysis, Patent pending), offers the user unprecedented analysis methods. These include the resolution of co-eluted peaks into single components, the visualization of unseen peaks, and even the deletion of unnecessary peaks to simplify analysis. Even co-eluted peaks… Are rendered as single components in the chromatogram Stability: Temperature-controlled TC-Optics function for obtaining even more reliable data The SPD-M30A further strengthens baseline stability via TC-Optics (Temperature Controlled Optics), a newly designed optical system. TC-Optics not only provides baseline stability during analysis, but also contributes to shortening the stabilization time required from instrument startup until analysis can start. As a result, it provides more reliable data, while improving total analytical throughput. mAU mAU 10 SPD-M30A 254 nm 25 20 30°C Room temperature 0 15 -10 10 25°C 5 SPD-M30A -20 0 Other vendor’s PDA detector -5 -30 -10 -15 -20 Other vendor’s PDA detector 0 100 200 300 400 500 600 min -40 0 10 20 30 40 50 min Stability with Respect to Room Temperature Shifts Baseline After Instrument Startup With the SPD-M30A, the baseline remains essentially In comparison to the competing PDA detector, the baseline constant even if the room temperature shifts. stabilizes much faster after instrument startup. Sensitivity and Resolution: Superior sensitivity and resolution are achieved with the capillary cell (SR-Cell) Broad compatibility from a single system, from UHPLC to HPLC The SPD-M30A also features a newly design capillary cell The SR-Cell can be used for both UHPLC and HPLC. As a result, a (SR-Cell), which provides both high sensitivity and high Nexera SR system equipped with the SPD-M30A can be utilized for a resolution. With its excellent sensitivity and wide dynamic wide range of analyses without replacing the cell. detection range, both the peak from the principal component HPLC conditions and a 0.005% infinitesimal peak can be quantified simultaneously, as shown in the example below. Main peak mAU 1750 μAU 0.0 2.5 5.0 10.0 12.5 15.0 17.5 min Faster speed 600 1250 7.5 400 S/N 9.53 UHPLC conditions 200 0 750 0.5 0.7 0.9 min Impurity peak 250 0 0.0 0.5 1.0 min Example of analysis when adding impurities of 0.005% for a main component 0.00 0.50 1.00 1.50 2.00 2.50 min Example of Faster Batch Analysis of Artificial Colorants The High-End Nexera SR System: Nexera X2 Centered on the SPD-M30A Equipped with the SPD-M30A, the Nexera SR is a high-end system in the Nexera X2 series. The cell and the optical system have been redesigned in detail, to achieve the highest level of sensitivity, low noise, and high resolution. In addition, it is equipped with the new i -PDeA function that obtains separated peaks through the deconvolution of co-eluted peaks (using the Shimadzu Workstation). With its high-sensitivity, high-resolution capabilities, the Nexera SR could be called the pinnacle of the Nexera X2 series. Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol “TM” or “®”. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. www.shimadzu.com/an/ © Shimadzu Corporation, 2013 Printed in Japan 3655-12221-20ANS
© Copyright 2025 Paperzz