x-lux standard - B

X-LUX STANDARD – BR 597 218
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted. Inclusive ATEX-certification for
complete construction.
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- central closing device for cover
- Polycarbonate reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 18W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area -40°C to +55°C
- Dimensions (L x B x H) 785 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 400 mm
- CE-sign, F-sign
- ATEX-certification
- T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 218
X-LUX STANDARD – BR 597 236
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted. Inclusive ATEX-certification for
complete construction.
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- central closing device for cover
- Polycarbonate reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 36W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area -40°C to +55°C
- Dimensions (L x B x H) 1390 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 236
X-LUX STANDARD – BR 597 336
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted. Inclusive ATEX-certification for
complete construction.
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- central closing device for cover
- Polycarbonate reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 3x 36W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area -40°C to +55°C
- Dimensions (L x B x H) 1390 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 336
X-LUX STANDARD – BR 597 258
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted. Inclusive ATEX-certification for
complete construction.
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- central closing device for cover
- Polycarbonate reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 58W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area -40°C to +55°C
- Dimensions (L x B x H) 1690 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 258
X-LUX STANDARD – BR 597 358
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted. Inclusive ATEX-certification for
complete construction.
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- central closing device for cover
- Polycarbonate reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 3x 58W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area -40°C to +55°C
- Dimensions (L x B x H) 1690 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 358
X-LUX STANDARD – BR 597 218 – 3H
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted, as self-contained light fitting with
AUTOTEST-Function according to DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838 for installations according to DIN VDE
0108 / 10.89 for separate operation. Inclusive ATEX-certification for complete construction.
- Duration 3 hours
- Maintained and non maintained version
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- Steel reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 58W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area 0°C to 55°C
- Built-in battery for 3 hours duration
- Dimensions (L x B x H) 785 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 400 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 218 – 3H
X-LUX STANDARD – BR 597 236 – 3H
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted, as self-contained light fitting with
AUTOTEST-Function according to DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838 for installations according to DIN VDE
0108 / 10.89 for separate operation. Inclusive ATEX-certification for complete construction.
- Duration 3 hours
- Maintained and non maintained version
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- Steel reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 36W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area 0°C to 55°C
- Built-in battery for 3 hours duration
- Dimensions (L x B x H) 1390 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 236 – 3H
X-LUX STANDARD – BR 597 258 – 3H
Explosion-proof light fitting in standard design for use in EX-zones 1 and 2, wall-/ceiling mounted, as self-contained light fitting with
AUTOTEST-Function according to DIN EN 60598-1, DIN EN 60598-2-22 and DIN EN 1838 for installations according to DIN VDE
0108 / 10.89 for separate operation. Inclusive ATEX-certification for complete construction.
- Duration 3 hours
- Maintained and non maintained version
- Explosion-proof, for use in EX-zone 1 and 2
- Wall-/Ceiling mounted
- Polyester fibre glass housing, grey (RAL 7035), unbreakable
- Polycarbonate cover, transparent, unbreakable
- Steel reflector, white powder coated
- Inclusive steel mounting brackets for wall-/ceiling mounting, also suitable for pendant mounting
- Supply voltage 230V AC
- for bulb T8 - 2x 58W
- Electronic ballast
- Protection degree IP 66
- Insulation class I
- Temperature class T4, T5*
- Certification code Ex II 2G EX de IIC T5-T4; 2D EX tD A21 IP66/67 T75°C
- Application area 0°C to 55°C
- Built-in battery for 3 hours duration
- Dimensions (L x B x H) 1690 x 217 x 145 mm, (H1 x S x S1) 170 x 230 x 205
- Mounting hole distance (L1) 700 mm
- CE-sign, F-sign
- ATEX-certification
T5* max. operating temperature +40°C (ceiling mounted)
Manufacturer: B-SAFETY or equal
Article No.:
BR 597 258 – 3H