RM5G Series Simple Version Operation Manual http://www.rhymebus.com.tw 2014.10.23 Edition Thank you for using RHYMEBUS RM5G series drive. For proper operations and safety purposes, please read complete manual carefully (enclose CD inside the box) or visit RHYMEBUS website: http://www.rhymebus.com.tw to download the operation manual. To prevent any possible dangers ,only the qualified personnel may proceed with the installation. Please pay attention to the safety precautions marked with “DANGER” or “CAUTION” in complete manual before installation. DANGER CAUTION Power and Braking Motor Power Source Terminals of Main Circuit R,S (L,N) R,S,T (L1,L2,L3) + ○ U,V,W (T1,T2,T3) - P(+), N○ +, N○ - P○ P, N P, PR P(+), PR +, PR P○ P(+), P1 +, P1 P○ Grounding User may cause the casualty or serious damages if user does not abide by the instructions of the manual to execute the tasks. User may cause injuries to the people or damage the equipment if user does not abide by the instructions of the manual to execute the tasks. PE(or G) AC power source input terminals Single-phase; sinusoidal power source input terminals. Three-phase; sinusoidal power source input terminals. DC power source External DC power source terminal. input terminals ※Only 2007 ~ 2015, 4007 ~ 4020 models have the terminal. Drive outputs to motor terminals Output three-phase variable frequency and voltage to motor. Dynamic brake unit The terminalscan connect to dynamic braking terminal unit(option). External brakingresistor terminal The terminals can connect to external brake resistor (option). External reactor terminal The terminal can connect to DC reactor (DCL) for improving power factor. The default setting is connected by a jumper. Ground the drive in compliance with the NEC standard Grounding terminal or local electrical code. 1 Model: RM5G-1001/2-1PH~RM5G-1002-1PH ; RM5G-2001/2-1PH~RM5G-2002-1PH Model: RM5G-2001/2~RM5G-2005 ; RM5G-4001~RM5G-4005 RM5P-2001~RM5P-2005; RM5P-4002~RM5P-4007 ※2: Braking Resistor(option) ※Single-Phase connect to R/L1 R/L1,S/L2 terminal. S/L2 ※Three-Phase connect to R/L1,S/L2 ,T/L3 terminal. T/L3 PR P Induction Motor N R/L1 U/T1 S/L2 RM5G V/T2 T/L3 IM W/T3 G G Model: RM5G-2007 ~ RM5G-2015; RM5P-2010 ~ RM5P-2020; Model: RM5G-4007 ~ RM5G-4025; RM5P-4010 ~ RM5P-4030 ※2:Braking Resistor (option) ※1:DC Reactor(DCL; option) Jumper PR R/L1 Three-Phase, 50/60Hz AC Power Input S/L2 R/L1 T/L3 T/L3 S/L2 P(+) P1 Induction Motor N U/T1 RM5G/P V/T2 IM W/T3 Model: RM5G-2020 ~ RM5G-2040;RM5P-2025 ~ RM5P-2050; Model: RM5G-4030 ~ RM5G-4060; RM5P-4040 ~ RM5P-4075 ※1:DC Reactor(DCL; option) Jumper P(+) R/L1 Three-Phase, 50/60Hz AC Power Input S/L2 T/L3 R/L1 S/L2 Induction Motor N P1 U/T1 RM5G/P V/T2 T/L3 IM W/T3 Model(B Type): RM5G-2020B ~ RM5G-2040B;RM5P-2025B ~ RM5P-2050B; Model(B Type): RM5G-4030B ~ RM5G-4060B; RM5P-4040B ~ RM5P-4075B ※1: DC Reactor(DCL; option) ※2:Braking Resistor(option) Jumper PR Three-Phase 50/60Hz AC Power Input R/L1 R/L1 S/L2 S/L2 T/L3 T/L3 P(+) P1 N Induction Motor U/T1 RM5G/P V/T2 W/T3 2 IM Model: RM5G-2050 ~ RM5G-2075;RM5P-2060 ~ RM5P-2100; Model: RM5G-4075 ; RM5P-4100 ※1:DC reactor(DCL; option) Jumper P(+) R/L1 Three-Phase, 50/60Hz AC Power Input S/L2 T/L3 S/L2 T/L3 Induction Motor N P1 R/L1 U/T1 RM5G/P V/T2 IM W/T3 Model(B Type): RM5G-2050B ~ RM5G-2075B; Model(B Type): RM5G-4075B;RM5P-4125B ※2:Braking Resistor(option) PR R/L1 Three-Phase, 50/60Hz AC Power Input S/L2 T/L3 P S/L2 T/L3 Induction Motor N R/L1 U/T1 RM5G/P V/T2 IM W/T3 Model: RM5G-2100~RM5G2250; RM5P-2125~RM5P-2250 Model: RM5G-4100~RM5G-4600; RM5P-4125~RM5P-4700 ※1 DCL Jumper ※1 P+ ACL R/L1 Three-Phase, 50/60Hz AC Power Input S/L2 T/L3 P1 U/T1 R/L1 S/L2 Induction Motor NӨ RM5G/P V/T2 IM W/T3 T/L3 PE PE ※1.RM5G-100HP/RM5P-125HP above drives: AC reactor (ACL) is the standard accessory; RM5G-175HP/RM5P-200HP above drives: DC reactor (DCL) is the standard accessory. Please remove the jumper between P1 and P terminal, when connecting the external DC reactor (DCL). Do Not remove the jumper, when DC reactor (DCL) does not be connected. ※2.PR terminal is suitable for braking resistor and B Type Series of RM5G is optional (Example: RM5G-2020B, include braking resistor) 3 Control Termianl Control power Type Symbol X1 X2 Input terminals X3 X4 X5 X6 COM Vin Iin FM+ AM+ M- Output terminals Control circuit terminal Function Power terminal; Control P12/12V device usage Common of analog input GND control terminals Forward command FWD terminal Reverse command REV terminal Ta1 Tb1 Tc1 Ta2 Tc2 Y1 Y2 CME Description Output DC+12V; Maximum supplied current is 20mA. Common of power terminals(P12/12V) and analog input control terminals (Vin, Iin). Connect the FWD and COM terminals for forward operation. (F_001=0,1,2) Connect the REV and COM terminals for reverse operation. (F_001=0,1,2) ․Connect the X1 and COM terminals and set the function Multi-function input F_052. terminal 1 ․Default setting: Multi-speed level 1 command ․Connect the X2 and COM terminals and set the function Multi-function input F_053. terminal 2 ․Default setting: Multi-speed level 2 command ․Connect the X3 and COM terminals and set the function Multi-function input F_054. terminal 3 ․Default setting: Jog command ․Connect the X4 and COM terminals and set the function Multi-function input F_055. terminal 4 ․Default setting: Secondary accel/decel time command ․Connect the X5 and COM terminals and set the function Multi-function input F_056. terminal 5 ․Default setting: External fault command (thr) ․Connect the X6 and COM terminals and set the function Multi-function input F_057. terminal 6 ․Default setting: Reset command Common of digital input Common of digital input control signal terminals. (FWD, controlterminals REV and X1 ~ X6) Analog input terminal Input range: DC 0~10V。 ․Input signal selection SW1: I position (current signal) SW1: V position (voltage signal) Analog input terminal ․Input range: DC 4~20mA (2~10V) or DC 0~20mA (0~10V) ․The function is set by F_126. ․Voltage meterwith 10V full scale spec. Analog output terminals (meter impedance: 10kΩ above) ․Maximum output current: 1mA Common of analog Common of analog output terminals. output terminals ․N.O (contact a); The function is set by F_060 (default setting: Error detection). ․Capacity: AC250V, 0.5AMax, cosθ=0.3 ․N.C (contact b); The function is set by F_060 (default setting: Error detection). Multi-function output ․Capacity: AC250V, 0.5AMax, cosθ=0.3 terminals (relay type) Common terminal for Ta1, Tb1. ․N.O (contact a); The function is set by F_131 (default setting: Operation detection). ․Capacity: AC250V, 0.5AMax, cosθ=0.3 Common terminal for Ta2. Multi-function output ․The function is set by F_058, F_059. ․Capacity: DC48V, 50mAMax terminals (open collector type) Common terminal of Y1, Y2. 4 Description of Terminal and Wiring Diagram Shielded Wire P Twisted-Pair Shielded Wire RM5G Forward Reverse FWD ※1 REV X1 X2 X3 SINK X4 SW2 X5 X6 SOURCE Multi-function Input Terminal 1 Multi-function Input Terminal 2 Multi-function Input Terminal 3 Multi-function Input Terminal 4 Multi-function Input Terminal 5 Multi-function Input Terminal 6 COM 12V VR 1KΩ,1/4W Vin I Analog Input Setting (Default: DC 0~10V) P PP V GND (+) FM+ GND Analog Output Terminal (+) (DC 0~10V) (-) Ta2 Tc2 Multi-function Output Terminal (Relay Type) Ta1 (AC 250V/0.5A COSθ=0.3) Tb1 Tc1 Y1 SW1 Iin AM+ ※2 Multi-function Output Terminal (Open collector) Y2 (DC 48V/50mA) CME Analog Input Setting (Default: DC 4~20mA) Voltage Board of Cooling Fan ※1.SW2: SINK /Selection SOURCE selection; The input signal mode selection of multi-function input terminal(X1~X6), FWD/REV terminals. ※2.SW1: I / V selection; I position: Iin-GND terminal is inputted with thecurrent signal.(default) V position:Iin-GND terminal is inputted with the voltage signal. ※3.The analog input selection is set by F_126 (default: DC 2~10V(4~20mA)) Voltage Selection Board of Cooling Fan ※RM5G-4075 / RM5P-4100 above models have the voltage selection board shown in above figure when removing the main circuit terminal cover of the drive. Please carefully select the jumper position according to the power source(actual power voltage level) to avoid the burnout of the fan or the overheating of the drive.(EX: When the power source is 460V, selecting the position from 380V to 460V) 5 Digital Type Keypad (KP-201C) for RM5G/P 1. T.S: Indicate the status of terminals 2. Unit indicator 1. ON: Primary frequency command is set by keypad or UP/DOWN terminal 2. OFF: Primary frequency command is set by multi-function input terminals Blinking: Under acceleration or deceleration ON: Constant speed OFF: Stop Drive start key 1. Enter function setting mode 2. Back to monitor mode Up/down key of changing functions and parameters 1. Enter parameter setting mode 2. Back to function setting mode 3. Switch monitor mode 1. Drive stops(cut off output frequency of drive) 2. Fault reset Operation of Keypad The operation of the digital keypad includes fault messages and three modes. The switching methods are shown as below figure: KEYPAD Hz A FUN KEYPAD PROG V Parameter setting mode Function setting mode Monitor mode Hz V KEYPAD DATA A PROG FUN Hz V A DATA STOP RESET PROG KEYPAD Hz V A Fault message *When the keypad is idle for three minutes at “function setting mode”or “parameter setting mode”, drive will switch back to the“main display”. The operation steps are shown as below table (by default setting) Operation Steps Display KEYPAD 1.Start the drive and enter the monitor mode. Hz V A KEYPAD 2.Press PROG key and enter the function setting mode. Hz V A KEYPAD 3.Press FUN DATA key and enter the parameter setting mode. Hz V A KEYPAD 4.Press FUN DATA key and return to the function setting mode. Hz V A KEYPAD 5.Press PROG key and return to the monitor mode. Hz 6 V A Description of Monitor Mode FUN There are eight displays can be selected in the monitor mode. Press DATA to switch the display in accordance with below sequence under monitor mode. User can determine one of eight displays as the main display from function F_006 (Selection of Main Display). Please refer to the following illustrations: Enter monitor mode Display 1 (Output Frequency) Display 2 (Frequency Command) KEYPAD Hz Display 3 (Output Voltage) KEYPAD V KEYPAD FUN FUN DATA DATA A Hz V A Hz DATA Display 8 (Terminal Status) Display 4 (DC Bus Voltage) Monitor Mode KEYPAD V KEYPAD A Hz FUN A DATA KEYPAD KEYPAD V V FUN DATA Hz A FUN FUN DATA Hz V A Display 7 (Machine Speed(MPM)) KEYPAD FUN FUN DATA DATA Hz V A Display 6 (Motor Speed(RPM)) Hz V A Display 5 (Output Current) a. Select one of eight displays as the main display from function F_006 (Selection of Main Display). b. Determine one of eight displays as the main display according to the application. When the parameter of function is completed without pressing key, the drive will automatically switch back to the main display after 3 minute. 7 Parameter List Func. Name Description 0: Software version1: Drive model number 2: Drive running hours F_000 Drive Information 3: Drive supply power time 4: Software checksum code 5: Reserved Rotation direction Start command command 0: FWD or REV terminal FWD or REV terminal F_001 Start Command Selection 1: FWD terminal REV terminal 2: FWD, REV terminal Keypad “RUN” key 3: Forward direction 4: Reverse direction 0:Frequency command by analog signal via terminal. 1:Frequency command by keypad. 2: Motor speed (RPM) command by keypad. 3: Machine speed (MPM) command by keypad. 4: Frequency command by UP/DOWN terminal. F_002 Primary Frequency Command Selection F_003 Selection of “STOP” Key Validity F_004 Frequency Command Selection F_005 Selection of Frequency Command Auto-Storing 0: In the monitor mode, frequency command cannot be changed. 1: In the monitor mode, frequency command is changeable. 0: In the monitor mode, frequency command auto-storing disable. 1: In the monitor mode, frequency command auto-storing after 3 minutes. F_006 Selection of Main Display Select 1 of 8 “monitor modes” as the main display. Machine Speed F_007 Ratio Digits of Decimal F_008 Value (Machine Speed) F_009 Primary Speed 0: Start command by terminal, “STOP” key disabled. 1: Start command by terminal, “STOP” key enabled. Set the ratio of machine speed. This function determines MPM display value. Select the digits of decimal values displaying the machine speed. Jog speed command Multi-speed level 3 command OFF OFF OFF Default ─ ─ ─ 0~4 ─ 3 0~4 ─ 1 0,1 ─ 1 0,1 ─ 1 0,1 ─ 1 1~8 ─ 1 0.00~ 500.00 0.01 20.00 0~3 ─ 0 50.00 (Note1) 60.00 OFF Preset Speed 1 OFF OFF OFF ON F_011 F_012 F_013 F_014 F_015 F_016 F_017 Preset Speed 2 Preset Speed 3 Preset Speed 4 Preset Speed 5 Preset Speed 6 Preset Speed 7 Jog Speed OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON ON X ON ON OFF OFF ON ON X OFF ON OFF ON OFF ON X Reference Frequency of The frequency corresponding to accel/decel time. Accel/Decel Time 8 Unit Multi-speed Multi-speed level 2 level 1 command command F_010 F_018 Range of Setting (Note2) 10.00 0.00~ 400.00 0.01 Hz 20.00 30.00 0.00 0.00 0.00 0.00 6.00 50.00 0.01~ 400.00 0.01 Hz (Note1) 60.00 (Note2) Func. F_019 F_020 F_021 F_022 F_023 F_024 F_025 F_026 F_027 F_028 F_029 F_030 Name Description Range of Setting Primary The acceleration time of primary speed, preset speed Acceleration Time 4~7, and jog speed. Primary The deceleration time of primary speed, preset speed Deceleration Time 4~7, and jog speed. Acceleration Time Acceleration time of preset speed 1. of Preset Speed 1 Deceleration Time Deceleration time of preset speed 1. of Preset Speed 1 Acceleration Time Acceleration time of preset speed 2. of Preset Speed 2 0.0~ Deceleration Time 3200.0 Deceleration time of preset speed 2. of Preset Speed 2 Acceleration Time Acceleration time of preset speed 3. of Preset Speed 3 Deceleration Time Deceleration time of preset speed 3. of Preset Speed 3 Secondary Switch to secondary acceleration time by Acceleration Time multi-function input terminal. Secondary Switch to secondary deceleration time by Deceleration Time multi-function input terminal. Set S-curve for Set S-curve to slow the acceleration and deceleration 0.0~5.0 Accel/Decel Time time at start and stop. Limitation of 0: Output voltage of V/F pattern is not limited. 0, 1 Output Voltage 1: Output voltage of V/F pattern is limited. Unit Default 0.1 sec (Note5) 0.1 sec ─ 15.0 0.0 0 50.0 F_031 Maximum Output Maximum output frequency of drive. Frequency 0.1~400.0 0.1Hz (Note1) 60.0 (Note2) F_032 Starting Frequency F_033 Starting Voltage Starting frequency of drive’s output. 0.1~10.0 0.1Hz The voltage corresponds to the output starting frequency. 0.1~50.0 0.5 8.0 0.1V 0.1~100.0 (Note3) 12.0 (Note4) 50.0 F_034 Base Frequency The frequency corresponds to the base voltage in V/F pattern. 0.1~400.0 0.1Hz (Note1) 60.0 (Note2) F_035 F_036 F_037 F_038 Base Voltage The voltage corresponds to the base frequency in V/F pattern. V/F Frequency 1 Frequency at the first point of V/F pattern. V/F Voltage 1 Voltage at the first point of V/F pattern. V/F Frequency 2 Frequency at the second point of V/F pattern. F_039 V/F Voltage 2 F_040 Vin Gain Voltage at the second point of V/F pattern. Analog input “Vin” gain ratio adjustment. F_041 Vin Bias Analog input “Vin” bias ratio adjustment. 220.0 0.1~255.0 0.1V 0.1~510.0 (Note3) 380.0 (Note4) 0.0~399.9 0.1Hz 0.0~255.0 0.1V 0.0~510.0 0.0 0.0~399.9 0.1Hz 0.0 0.0~255.0 0.1V 0.0~510.0 0.00~2.00 0.01 1.00 -1.00~ 1.00 0.0 0.0 0.01 0.00 F_042 Frequency Upper The upper limit of output frequency= Limit F_031(Maximum Output Frequency )*F_042 0.00~1.00 0.01 1.00 F_043 Frequency Lower The lower limit of output frequency= F_031(Maximum 0.00~1.00 0.01 Limit Output Frequency )*F_043 0.00 9 Func. F_044 F_045 F_046 F_047 F_048 F_049 F_050 F_051 F_052 F_053 F_054 F_055 F_056 F_057 Name Description 0: Output frequency Analog Output 1: Frequency command Signal Selection 2: Output current (FM+) 3: “Vin” analog input signal. Analog Output Gain(FM+) 4: “Iin” analog input signal. 5: DC bus voltage. 6. Output voltage. Analog output gain ratioadjustment. 0: Disable 1: Overload protection for dependent cooling fan type Motor Overload motor:Enabled(OL) Protection (OL) 2: Overload protection for independentcooling fan type motor: Enabled(OL) Filter Setting of Filter the analog input signal when the frequency Analog Input command is controlled by analog input terminal. Signal (F_002=0). Motor Rated Current Set the value according to the motor rated current. Motor No-Load Current setting according to the motor’s no-load Current condition. According to the load condition, set the motor slip Motor Slip compensation for motor running at constant speed. Compensation (0.0: off) Range of Setting Unit Default 0~6 ─ 0 0.00~2.00 0.01 0~2 ─ 0~255 ─ 10%~150% of drive rated current 0.1A 0~motor rated current 0.1A -9.9~10.0 0.1Hz Number of Motor Determinate the RPM display value of monitor mode. 2~10 Poles =0: Multi-function UP/DOWN frequency ±1: Jog command Input Terminal command enter key ±2: Secondary (X1) accel/decel time command =0: Multi-function ±3: Multi-speed level 1 DC braking enable command Input Terminal (at stop) ±4: Multi-speed level 2 (X2) command =0: ±5: Multi-speed level 3 Multi-function Current limit enable command Input Terminal ±6: Reset command (X3) ±7: External fault command(thr) =0: ±8: Interruption of output Selection of primary or command(bb) secondary frequency -16~ +16 Multi-function command ±9: Coast to stop (Note 7) Input Terminal (ON: secondary frequency command(Fr) (X4) command) ±10: Speed tracing from the maximumfrequency =0: Stop command with 3-wire ±11: Speed tracing from Multi-function the setting start/stop circuit frequency Input Terminal (N.O; contact a) ±12: Holding command (X5) ±13: UP command ±14: DOWN command =0: Stop command with 3-wire ±15: Clear UP/DOWN Multi-function frequencycommand start/stop circuit Input Terminal (N.C; contact b) ±16: Analog input source (X6) selection 10 2P 1.00 1 20 According to the rated current of motor 1/3 motor rated current 0.0 4P 3 4 1 ─ 2 7 6 Func. F_058 F_059 F_060 F_061 F_062 F_063 F_064 F_065 F_066 F_067 F_068 F_069 F_070 F_071 F_072 F_073 F_074 Name Description Range of Setting 0: Disable Multi-function Output Terminal ±1: Operation command detection ±2: Constant speed detection (Y1) ±3: Zero speed detection ±4: Frequency detection Multi-function Output Terminal ±5: Overload detection(OLO) -11 ~+11 ±6: Stall prevention detection (Note 7) (Y2) ±7: Low voltage detection(LE) ±8: Braking detection Multi-function ±9: Restart after instantaneous power failure detection Output Terminal ±10: Restart after error condition detection (Ta1,Tb1) ±11: Error detection Constant Speed Set the bandwidth of constant speed detection range. 0.0~10.0 Detection Range Frequency Set the bandwidth of frequency detection range. 0.0~10.0 Detection Range Frequency Set the frequency detection level of multi-function 0.0~400.0 Detection Level output terminal. Automatic Torque According to the load condition, adjust the output Compensation 0.0~25.5 voltage of the V/F pattern. (0.0: off) Range System Overload 0: Disable 0,1 Detection (OLO) 1: Enable System Overload 0: Detection during constant speedonly 0,1 DetectingSelection 1: Detection during operation only 0: Drive keeps operation when the overload is Output Setting detected after System 0,1 1: Drive trips to protection when the overload Overload isdetected 30%~200% When the output current of drive is larger than the System Overload of drive levelwith the duration of F_069, the drive will trip to rated Detection Level protection. current When the output current of drive is larger than the System Overload level (F_068 * drive’s rated current) with the duration, 0.1~10.0 Detection Time the drive will trip to protection. 30%~200% Stall Prevention If stall is occurred during acceleration, the motor of drive Level at rated keeps running at constant speed. (200%: off) Acceleration current 30%~200% Stall Prevention While the stall is occurred during constant speed of drive Level at Constant running condition, the prevention of stall is to rated Speed decrease the speed of motor.(200%: off) current Acceleration Time Setting after Stall Set the acceleration time after stall prevention under 0.1~ Prevention under the constant speed. 3200.0 Constant Speed Deceleration Time Setting for Stall Set the deceleration time at the stallprevention under 0.1~ Prevention under the constant speed. 3200.0 Constant Speed Stall Prevention 0: Disable Setting at 0, 1 Deceleration 1: Enable F_075 DC Braking Level Set the current level of DC braking. 11 0~150% of drive rated current Unit Default 3 ─ 2 11 0.1Hz 2.0 0.1Hz 2.0 0.1Hz 0.0 0.1 1.0 ─ 0 ─ 0 ─ 0 1% 160 0.1 sec 0.1 1% 170 1% 160 0.1 sec (Note5) 0.1 sec (Note5) ─ 1 1% 50 15.0 15.0 Func. Name Description Time of DC F_076 Set the time for DC braking after drive stopped. Braking after Stop Time of DC F_077 Braking before Set the time for DC braking before drive started. Start 0: Drive cannot be restarted Operation 1: Drive can be restarted Selection at 2: Ramp to stop F_078 Instantane- ous 3: Drive will re-accelerate again during ramp to stop Power Failure interval, when the power is restored. F_079 F_080 F_081 F_082 F_083 F_084 Voltage Level of Ramp to Stop by Set the voltage of power source for ramp to stop. Power Failure When the auto-restart times of error conditions Auto-restart Times (OC,OE,GF only) reach the setting value, the drive Setting of Error must be restarted manually. Trip 0: disable Switching The setting value is higher and the motor noise is Frequency lower. 0: Ramp to stop 1: Coast to stop Stop Mode 2: Coast to stop+ DC braking Reverse 0: Reverse rotation allowed. Prohibition 1: Reverse rotation NOT allowed. Jump Frequency 1 Avoid mechanical resonance point 1. Range of Setting Unit Default 0.0~20.0 0.1 sec 0.5 0.0~20.0 0.1 sec 0.0 0~3 ─ 0 150.0~ 192.0 300.0~ 384.0 0.1V 0~16 1 0~6 ─ 0~2 ─ 0 0, 1 ─ 0 175.0 (Note3) 320.0 (Note4) 0 1 (Note6) 0.0~400.0 0.1Hz 0.0 F_085 Jump Frequency 2 Avoid mechanical resonance point 2. 0.0~400.0 0.1Hz 0.0 F_086 Jump Frequency 3 Avoid mechanical resonance point 3. 0.0~400.0 0.1Hz 0.0 0.0~25.5 0.1Hz 0.0 F_087 Jump Frequency Set the range of the jump frequency 1, 2, 3. Range When the current is higher than the “speed The Current Level F_088 of Speed Tracing tracingcurrent level”, the output frequency will trace downward. 0~200% of drive rated current 1% 150 F_089 Delay Time before Speed Tracing Set the output delay time before the speed tracing. 0.1~5.0 0.1 sec 0.5 F_090 The V/F Pattern of Set the percentage of V/F output voltage at the speed 0~100% Speed Tracing tracing. F_091 Display the latest 5 error records. 0: Parameters are changeable. Maximum frequency cannot exceed 120.0Hz. 1: Parameters are locked. Maximum frequency Parameter Setting cannot exceed 120.0Hz. F_092 2: Parameters are changeable. Maximum frequency Lock can exceed 120.0Hz. 3: Parameters are locked. Maximum frequency can exceed 120.0Hz. Automatic Voltage 0: Disable F_093 Regulation (AVR) 1: Enable 0: Disable Drive Overload 1: Thermal protection F_094 2: Current limit overload protection (OL1) 3: Both 1 and 2 enable F_095 Error Record Power Source The value of setting according to the actual power source. 12 1% 100 ─ ─ ─ 0~3 ─ 0 0,1 ─ 1 0~3 ─ 3 190.0~ 240.0 340.0~ 480.0 0.1V 220.0 (Note3) 380.0 (Note4) Func. Name Description The drive accelerates to the holding frequency and F_096 Holding Frequency running at constant speed. Holding Time The drive runs at holding frequency by constant F_097 Interval speed and running the time interval. Range of Setting Unit 0.0~400.0 0.1Hz Default 0.5 0.0~25.5 0.1 sec 0.0 F_098 Grounding Fault 0: Disable Protection (GF) 1: Enable(GF) 0, 1 ─ 1 F_099 External Indicator Select the monitor mode of external indicator 1 1 0: Disable 0~8 ─ 1 F_100 External Indicator Select the monitor mode of external indicator 2 2 0: Disable 0~8 ─ 2 F_101 External Indicator Select the monitor mode of external indicator 3 3 0: Disable 0~8 ─ 3 0~4 ─ 0 0.1Hz 3.0 0.1 sec (Note5) 0.1 sec (Note5) 0.1Hz 0.0 0.01 Hz 0.00 1ms 10 ─ 1 ─ 20 ─ 17 ─ 8 ─ 5 ─ 3 ─ 1 ─ 0 F_102 F_103 F_104 F_105 F_106 F_107 F_108 F_110 F_111 F_112 F_113 F_114 F_115 F_116 F_117 V/F Pattern Selection 0:Linear. 1: Energy-saving mode (auto-adjust V/F pattern according to the load condition). 2: Square curve. th 3: 1.7th power curve. 4: 1.5 power curve. Subtracted When the power failure, drive will reduce the Frequency of frequency level before ramp to stop. 0.0~20.0 Deceleration at F_078 Operation Selection at Instantaneous Power Power Failure Failure =2 or 3 Deceleration Time Set a deceleration time down to the turning frequency 0.0~ 1 of Ramp to Stop set in F_106. 3200.0 by Power Failure Deceleration Time Set a deceleration slope below the frequency set in 0.0~ 2 of Ramp to Stop F_106 3200.0 by Power Failure Set the turning frequency level of ramp to stopwhen Turning Frequency the deceleration time is switched from F_104 setting 0.0~400.0 of Ramp to Stop value to F_105setting value. When the noise of analog input signal is Analog Frequency large,appropriately increase the dead band to 0.00~2.55 Dead Band stabilize the frequency command. But adjusting this function will reduce the tuning linearity of input signal. Digital Input When the pulse width of digital signal is lower than 5~16 Response Time setting time, the signal disabled. ADJ4 Function Set the function of ADJ4switch of KP-202 keypad. 0~49 Selection ADJ5 Function Set the function of ADJ5switch of KP-202 keypad. 0~49 Selection ADJ6 Function Set the function of ADJ6switch of KP-202 keypad. 0~49 Selection DIP1 Function Set the function of DIP1switch of KP-202 keypad. 0~15 Selection DIP2 Function Set the function of DIP2switch of KP-202 keypad. 0~15 Selection DIP3 Function Set the function of DIP3switch of KP-202 keypad. 0~15 Selection DIP4 Function Set the function of DIP4switch of KP-202 keypad. 0~15 Selection Pot Knob of KP-202 keypad Set the function of pot knob of KP-202 keypad. 0~49 Function Selection 13 15.0 15.0 Func. F_118 F_119 F_120 F_121 F_122 F_123 F_124 F_125 F_126 F_127 F_128 F_129 F_130 F_131 F_132 Name Description Range of Setting 0: Clear the UP/DOWN frequency command when UP/DOWN power failure. 0, 1 Memory Selection 1: Save the UP/DOWN frequency command at F_121 when power failure. 0: 0.01Hz UP/DOWN 1~8: x0.05Hz Frequency 0~250 9: 0.5Hz Resolution 10~250: x0.1Hz 1~5: Cntinuousaccel./decel. when the terminal is UP/DOWN Trigger activated with the duration (1 ~ 5 sec). 1~6 Mode 6: Edge trigger UP/DOWN 0.00~ Frequency Adjust UP/DOWN frequency by KP-201C keypad. 400.00 Adjustment Secondary 0:Frequency command by analog signal via terminal. Frequency 1: Frequency command by keypad. 0~2 CommandSelectio 2: Frequency command by UP/DOWN terminal. n 0: Vin+Iin 1: Vin-Iin Analog 2: Iin-Vin 0~3 InputSelection 3: Vin or Iin (switch by multi-function input terminal X1 ~ X6). 0: Analog input gain. Analog Input 1: Frequency command. Selection 2: Current limit level. 0~3 (Vin) 3: Analog input (Vin) can adjust output voltage of V/F pattern 0: Analog input gain. Analog Input 1: Frequency command. Selection 2: Current limit level. 0~3 (Iin) 3: Analog input (Iin) can adjust output voltage of V/F pattern Iin Range 0: 4~20mA (2~10V). 0,1 Selection 1: 0~20mA (0~10V). Analog Input The gain ratio of analog input terminal Iin. 0.00~2.00 Gain(Iin) Analog Input -1.00~ The bias ratio of analog input terminal Iin. Bias(Iin) 1.00 0: Output frequency. 1: Frequency command. Analog Output 2: Output current. Signal Selection 3: Vin frequency command 0~6 (AM+) 4: Iin frequency command. 5: DC bus voltage 6: Output voltaga Analog Output AM+ analog output adjustment ratio. 0.00~2.00 Gain(AM+) Multi-function The way of settings are same as multi-function output -11~+11 Output Terminal terminals setting.(F_058 ~ F_060) (Note 7) (Ta2/Tc2) DC Braking Active frequency level of DC braking at stop. Frequencyat Stop F_133 Current Limit Level Monitor the setting value of current limit level percentage. 14 Unit Default ─ 0 ─ 0 ─ 1 0.01 Hz 0.00 ─ 0 ─ 0 ─ 1 ─ 1 ─ 0 0.01 1.00 0.01 0.00 ─ 2 0.01 1.00 ─ 1 0.1~60.0 0.1Hz ─ ─ 0.5 ─ Func. Name Description Range of Setting Unit Default ─ ─ ─ ─ 0 1 0 1 ─ ─ 0 0: Disable CLF: Clear fault records dEF60: Restore the default value of drive for 60Hz. dEF50: Restore the default value of drive for 50Hz. F_134 Default Setting SAv: Save the setting value. rES: Restore the setting value. rd_EE: Read the parameters from drive to digital keypad Wr_EE: Write the parameters from digital keypad to drive 1: Paramerter cannot be changed after F0.18 locked, Parameter Display but it can display the setting value. Selection of F_135 0~1 Parameter Lock 2: Paramerter cannot be changed after F0.18 locked, but it cannot display the setting value. Parameter Lock Setting the password of parameter lock. F_136 0~9999 Password Setting Parameter Lock F_137 Decording the password of parameter lock. 0~9999 Decoding Setting 0: Disable CLF: Clear fault records dEF60: Restore the default value of drive for 60Hz. F_154 dEF50: Restore the default value of drive for 50Hz. Default Setting SAv: Save the setting value. ─ rES: Restore the setting value. rd_EE: Read the parameters from drive to digital keypad(KP-201C) Wr_EE: Wr_EE: Write the parameters from digital keypad(KP-201C) to drive The color as means the functions can be set during operation. Note: 1. Default value of 50Hz. 2. Default value of 60Hz. 3. Specification of 200V series. 4. Specification of 400V series. 5. 0.5 ~ 5HP: 5sec 7.5 ~ 30HP: 15sec 40HP above: 30sec 6. RM5G series: When switching frequency setting exceeds 4, the drive must be de-rating or selecting higher capacity. RM5P series: When switching frequency setting exceeds 2, the drive must be de-rating or selecting higher capacity. 7.+: Represents a contact (N.O) -: Represents b contact (N.C) 15 Error Trip Messages of Drive Display Description Display (EEr) Description (OLO) KEYPAD KEYPAD EEPROM error Hz V A System overload Hz (AdEr) V A (thr) KEYPAD KEYPAD A/D converter error Hz V A External fault Hz (SC) V A (PAdF) KEYPAD Keypad interruption during copy KEYPAD Fuse open Hz V A Hz (LE1) KEYPAD Hz V V A (OH) KEYPAD Under voltage during operation A Drive overheating Hz (OC) V A (OL) KEYPAD KEYPAD Drive over current Hz V A Motor overload Hz (GF) V A (OL1) KEYPAD KEYPAD Grounding fault Hz V A Drive overload Hz V A (OE) KEYPAD Over voltage Hz V A Warning Messages of Drive Display Description Display (LE) Power source under voltage KEYPAD Hz V Description (PrEr) A KEYPAD Software fault Hz V A (Err_00) KEYPAD (bb) Drive output interruption KEYPAD Hz V Hz V A (Err_01) KEYPAD A Hz (Fr) V A (dtF) KEYPAD KEYPAD Direction command error Coast to stop Hz V A Hz KEYPAD V V A (Wr_F) (db) Hz Err_00: Keypad cable trip.(beforeconnecting) Err_01: Keypad cable trip.(connected) Over voltage at stop A Different software version inter-copy KEYPAD Hz 16 V A
© Copyright 2026 Paperzz