RM5G Series Simple Version Operation Manual

RM5G Series
Simple Version
Operation Manual
http://www.rhymebus.com.tw
2014.10.23 Edition
Thank you for using RHYMEBUS RM5G series drive.
For proper operations and safety purposes, please read complete manual carefully (enclose
CD inside the box) or visit RHYMEBUS website: http://www.rhymebus.com.tw to download
the operation manual. To prevent any possible dangers ,only the qualified personnel may
proceed with the installation. Please pay attention to the safety precautions marked with
“DANGER” or “CAUTION” in complete manual before installation.
DANGER
CAUTION
Power
and Braking
Motor Power Source

Terminals of Main Circuit
R,S
(L,N)
R,S,T
(L1,L2,L3)
+
○
U,V,W
(T1,T2,T3)
-
P(+), N○
+, N○
-
P○
P, N
P, PR
P(+), PR
+, PR
P○
P(+), P1
+, P1
P○
Grounding
User may cause the casualty or serious damages if user does not abide
by the instructions of the manual to execute the tasks.
User may cause injuries to the people or damage the equipment if user
does not abide by the instructions of the manual to execute the tasks.
PE(or G)
AC power source
input terminals
Single-phase; sinusoidal power source input terminals.
Three-phase; sinusoidal power source input terminals.
DC power source External DC power source terminal.
input terminals ※Only 2007 ~ 2015, 4007 ~ 4020 models have the terminal.
Drive outputs to
motor terminals
Output three-phase variable frequency and voltage to
motor.
Dynamic brake unit The terminalscan connect to dynamic braking
terminal
unit(option).
External
brakingresistor
terminal
The terminals can connect to external brake resistor
(option).
External reactor
terminal
The terminal can connect to DC reactor (DCL) for
improving power factor. The default setting is
connected by a jumper.
Ground the drive in compliance with the NEC standard
Grounding terminal or local electrical code.
1
Model: RM5G-1001/2-1PH~RM5G-1002-1PH ; RM5G-2001/2-1PH~RM5G-2002-1PH
Model: RM5G-2001/2~RM5G-2005 ; RM5G-4001~RM5G-4005
RM5P-2001~RM5P-2005; RM5P-4002~RM5P-4007
※2: Braking Resistor(option)
※Single-Phase connect to R/L1
R/L1,S/L2 terminal.
S/L2
※Three-Phase connect to
R/L1,S/L2 ,T/L3 terminal. T/L3
PR
P
Induction Motor
N
R/L1
U/T1
S/L2
RM5G
V/T2
T/L3
IM
W/T3
G
G
Model: RM5G-2007 ~ RM5G-2015; RM5P-2010 ~ RM5P-2020;
Model: RM5G-4007 ~ RM5G-4025; RM5P-4010 ~ RM5P-4030
※2:Braking Resistor
(option)
※1:DC Reactor(DCL; option)
Jumper
PR
R/L1
Three-Phase,
50/60Hz AC Power Input S/L2
R/L1
T/L3
T/L3
S/L2
P(+)
P1
Induction Motor
N
U/T1
RM5G/P
V/T2
IM
W/T3
Model: RM5G-2020 ~ RM5G-2040;RM5P-2025 ~ RM5P-2050;
Model: RM5G-4030 ~ RM5G-4060; RM5P-4040 ~ RM5P-4075
※1:DC Reactor(DCL; option)
Jumper
P(+)
R/L1
Three-Phase,
50/60Hz AC Power Input S/L2
T/L3
R/L1
S/L2
Induction Motor
N
P1
U/T1
RM5G/P
V/T2
T/L3
IM
W/T3
Model(B Type): RM5G-2020B ~ RM5G-2040B;RM5P-2025B ~ RM5P-2050B;
Model(B Type): RM5G-4030B ~ RM5G-4060B; RM5P-4040B ~ RM5P-4075B
※1: DC Reactor(DCL; option)
※2:Braking Resistor(option)
Jumper
PR
Three-Phase
50/60Hz AC Power Input
R/L1
R/L1
S/L2
S/L2
T/L3
T/L3
P(+)
P1
N
Induction Motor
U/T1
RM5G/P
V/T2
W/T3
2
IM
Model: RM5G-2050 ~ RM5G-2075;RM5P-2060 ~ RM5P-2100;
Model: RM5G-4075
; RM5P-4100
※1:DC reactor(DCL; option)
Jumper
P(+)
R/L1
Three-Phase,
50/60Hz AC Power Input S/L2
T/L3
S/L2
T/L3
Induction Motor
N
P1
R/L1
U/T1
RM5G/P
V/T2
IM
W/T3
Model(B Type): RM5G-2050B ~ RM5G-2075B;
Model(B Type): RM5G-4075B;RM5P-4125B
※2:Braking Resistor(option)
PR
R/L1
Three-Phase,
50/60Hz AC Power Input S/L2
T/L3
P
S/L2
T/L3
Induction Motor
N
R/L1
U/T1
RM5G/P
V/T2
IM
W/T3
Model: RM5G-2100~RM5G2250; RM5P-2125~RM5P-2250
Model: RM5G-4100~RM5G-4600; RM5P-4125~RM5P-4700
※1 DCL
Jumper
※1
P+
ACL
R/L1
Three-Phase,
50/60Hz AC Power Input S/L2
T/L3
P1
U/T1
R/L1
S/L2
Induction Motor
NӨ
RM5G/P
V/T2
IM
W/T3
T/L3
PE
PE
※1.RM5G-100HP/RM5P-125HP above drives: AC reactor (ACL) is the standard accessory;
RM5G-175HP/RM5P-200HP above drives: DC reactor (DCL) is the standard accessory.
Please remove the jumper between P1 and P terminal, when connecting the external DC
reactor (DCL). Do Not remove the jumper, when DC reactor (DCL) does not be connected.
※2.PR terminal is suitable for braking resistor and B Type Series of RM5G is optional
(Example: RM5G-2020B, include braking resistor)
3
 Control Termianl
Control
power
Type
Symbol
X1
X2
Input terminals
X3
X4
X5
X6
COM
Vin
Iin
FM+
AM+
M-
Output terminals
Control circuit terminal
Function
Power terminal; Control
P12/12V
device usage
Common of analog input
GND
control terminals
Forward command
FWD
terminal
Reverse command
REV
terminal
Ta1
Tb1
Tc1
Ta2
Tc2
Y1
Y2
CME
Description
Output DC+12V; Maximum supplied current is 20mA.
Common of power terminals(P12/12V) and analog input
control terminals (Vin, Iin).
Connect the FWD and COM terminals for forward
operation. (F_001=0,1,2)
Connect the REV and COM terminals for reverse operation.
(F_001=0,1,2)
․Connect the X1 and COM terminals and set the function
Multi-function input
F_052.
terminal 1
․Default setting: Multi-speed level 1 command
․Connect the X2 and COM terminals and set the function
Multi-function input
F_053.
terminal 2
․Default setting: Multi-speed level 2 command
․Connect the X3 and COM terminals and set the function
Multi-function input
F_054.
terminal 3
․Default setting: Jog command
․Connect the X4 and COM terminals and set the function
Multi-function input
F_055.
terminal 4
․Default setting: Secondary accel/decel time command
․Connect the X5 and COM terminals and set the function
Multi-function input
F_056.
terminal 5
․Default setting: External fault command (thr)
․Connect the X6 and COM terminals and set the function
Multi-function input
F_057.
terminal 6
․Default setting: Reset command
Common of digital input Common of digital input control signal terminals. (FWD,
controlterminals
REV and X1 ~ X6)
Analog input terminal Input range: DC 0~10V。
․Input signal selection
SW1: I position (current signal)
SW1: V position (voltage signal)
Analog input terminal
․Input range: DC 4~20mA (2~10V) or
DC 0~20mA (0~10V)
․The function is set by F_126.
․Voltage meterwith 10V full scale spec.
Analog output terminals
(meter impedance: 10kΩ above)
․Maximum output current: 1mA
Common of analog
Common of analog output terminals.
output terminals
․N.O (contact a); The function is set by F_060 (default
setting: Error detection).
․Capacity: AC250V, 0.5AMax, cosθ=0.3
․N.C (contact b); The function is set by F_060 (default
setting: Error detection).
Multi-function output
․Capacity: AC250V, 0.5AMax, cosθ=0.3
terminals
(relay type)
Common terminal for Ta1, Tb1.
․N.O (contact a); The function is set by F_131 (default
setting: Operation detection).
․Capacity: AC250V, 0.5AMax, cosθ=0.3
Common terminal for Ta2.
Multi-function output ․The function is set by F_058, F_059.
․Capacity: DC48V, 50mAMax
terminals
(open collector type) Common terminal of Y1, Y2.
4
 Description of Terminal and Wiring Diagram
Shielded
Wire
P
Twisted-Pair
Shielded Wire
RM5G
Forward
Reverse
FWD
※1
REV
X1
X2
X3 SINK
X4
SW2
X5
X6 SOURCE
Multi-function Input Terminal 1
Multi-function Input Terminal 2
Multi-function Input Terminal 3
Multi-function Input Terminal 4
Multi-function Input Terminal 5
Multi-function Input Terminal 6
COM
12V
VR
1KΩ,1/4W
Vin
I
Analog Input Setting
(Default: DC 0~10V)
P PP
V
GND
(+)
FM+
GND
Analog Output Terminal
(+) (DC 0~10V)
(-)
Ta2
Tc2 Multi-function Output Terminal
(Relay Type)
Ta1
(AC 250V/0.5A COSθ=0.3)
Tb1
Tc1
Y1
SW1
Iin
AM+
※2
Multi-function Output Terminal
(Open collector)
Y2 (DC 48V/50mA)
CME
Analog Input Setting
(Default: DC 4~20mA)
 Voltage
Board of Cooling Fan
※1.SW2:
SINK /Selection
SOURCE selection;
The input signal mode selection of multi-function input terminal(X1~X6), FWD/REV terminals.
※2.SW1: I / V selection; I position: Iin-GND terminal is inputted with thecurrent signal.(default)
V position:Iin-GND terminal is inputted with the voltage signal.
※3.The analog input selection is set by F_126 (default: DC 2~10V(4~20mA))
 Voltage Selection Board of Cooling Fan
※RM5G-4075 / RM5P-4100 above models have the voltage selection board shown in
above figure when removing the main circuit terminal cover of the drive. Please carefully
select the jumper position according to the power source(actual power voltage level) to
avoid the burnout of the fan or the overheating of the drive.(EX: When the power source
is 460V, selecting the position from 380V to 460V)
5
 Digital Type Keypad (KP-201C) for RM5G/P
1. T.S: Indicate the status
of terminals
2. Unit indicator
1. ON: Primary frequency
command is set by
keypad or UP/DOWN
terminal
2. OFF: Primary frequency
command is set by
multi-function input
terminals
Blinking: Under acceleration
or deceleration
ON: Constant speed
OFF: Stop
Drive start key
1. Enter function setting mode
2. Back to monitor mode
Up/down key of changing
functions and parameters
1. Enter parameter setting mode
2. Back to function setting mode
3. Switch monitor mode
1. Drive stops(cut off output
frequency of drive)
2. Fault reset
 Operation of Keypad
The operation of the digital keypad includes fault messages and three
modes. The switching methods are shown as below figure:
KEYPAD
Hz
A
FUN
KEYPAD
PROG
V
Parameter setting mode
Function setting mode
Monitor mode
Hz
V
KEYPAD
DATA
A
PROG
FUN
Hz
V
A
DATA
STOP
RESET
PROG
KEYPAD
Hz
V
A
Fault message
*When the keypad is idle for three minutes at “function
setting mode”or “parameter setting mode”, drive will switch
back to the“main display”.
The operation steps are shown as below table (by default setting)
Operation Steps
Display
KEYPAD
1.Start the drive and enter the monitor mode.
Hz
V
A
KEYPAD
2.Press PROG key and enter the function setting mode.
Hz
V
A
KEYPAD
3.Press
FUN
DATA
key and enter the parameter setting mode.
Hz
V
A
KEYPAD
4.Press
FUN
DATA
key and return to the function setting mode.
Hz
V
A
KEYPAD
5.Press PROG key and return to the monitor mode.
Hz
6
V
A

Description of Monitor Mode
FUN
There are eight displays can be selected in the monitor mode. Press DATA to switch the
display in accordance with below sequence under monitor mode. User can determine one of
eight displays as the main display from function F_006 (Selection of Main Display). Please
refer to the following illustrations:
Enter monitor mode
Display 1
(Output Frequency)
Display 2
(Frequency Command)
KEYPAD
Hz
Display 3
(Output Voltage)
KEYPAD
V
KEYPAD
FUN
FUN
DATA
DATA
A
Hz
V
A
Hz
DATA
Display 8
(Terminal Status)
Display 4
(DC Bus Voltage)
Monitor
Mode
KEYPAD
V
KEYPAD
A
Hz
FUN
A
DATA
KEYPAD
KEYPAD
V
V
FUN
DATA
Hz
A
FUN
FUN
DATA
Hz
V
A
Display 7
(Machine Speed(MPM))
KEYPAD
FUN
FUN
DATA
DATA
Hz
V
A
Display 6
(Motor Speed(RPM))
Hz
V
A
Display 5
(Output Current)
a. Select one of eight displays as the main display from function F_006 (Selection of Main
Display).
b. Determine one of eight displays as the main display according to the application. When
the parameter of function is completed without pressing key, the drive will automatically
switch back to the main display after 3 minute.
7
 Parameter List
Func.
Name
Description
0: Software version1: Drive model number
2: Drive running hours
F_000 Drive Information 3: Drive supply power time
4: Software checksum code
5: Reserved
Rotation direction
Start command
command
0:
FWD or REV terminal FWD or REV terminal
F_001
Start Command
Selection
1:
FWD terminal
REV terminal
2:
FWD, REV terminal
Keypad “RUN” key
3:
Forward direction
4:
Reverse direction
0:Frequency command by analog signal via terminal.
1:Frequency command by keypad.
2: Motor speed (RPM) command by keypad.
3: Machine speed (MPM) command by keypad.
4: Frequency command by UP/DOWN terminal.
F_002
Primary
Frequency
Command
Selection
F_003
Selection of
“STOP” Key
Validity
F_004
Frequency
Command
Selection
F_005
Selection of
Frequency
Command
Auto-Storing
0: In the monitor mode, frequency command cannot
be changed.
1: In the monitor mode, frequency command is
changeable.
0: In the monitor mode, frequency command
auto-storing disable.
1: In the monitor mode, frequency command
auto-storing after 3 minutes.
F_006
Selection of
Main Display
Select 1 of 8 “monitor modes” as the main display.
Machine Speed
F_007
Ratio
Digits of Decimal
F_008 Value (Machine
Speed)
F_009
Primary Speed
0: Start command by terminal, “STOP” key disabled.
1: Start command by terminal, “STOP” key enabled.
Set the ratio of machine speed. This function
determines MPM display value.
Select the digits of decimal values displaying the
machine speed.
Jog speed
command
Multi-speed
level 3
command
OFF
OFF
OFF
Default
─
─
─
0~4
─
3
0~4
─
1
0,1
─
1
0,1
─
1
0,1
─
1
1~8
─
1
0.00~
500.00
0.01
20.00
0~3
─
0
50.00
(Note1)
60.00
OFF
Preset Speed 1
OFF
OFF
OFF
ON
F_011
F_012
F_013
F_014
F_015
F_016
F_017
Preset Speed 2
Preset Speed 3
Preset Speed 4
Preset Speed 5
Preset Speed 6
Preset Speed 7
Jog Speed
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
X
ON
ON
OFF
OFF
ON
ON
X
OFF
ON
OFF
ON
OFF
ON
X
Reference
Frequency of The frequency corresponding to accel/decel time.
Accel/Decel Time
8
Unit
Multi-speed Multi-speed
level 2
level 1
command
command
F_010
F_018
Range of
Setting
(Note2)
10.00
0.00~
400.00
0.01
Hz
20.00
30.00
0.00
0.00
0.00
0.00
6.00
50.00
0.01~
400.00
0.01
Hz
(Note1)
60.00
(Note2)
Func.
F_019
F_020
F_021
F_022
F_023
F_024
F_025
F_026
F_027
F_028
F_029
F_030
Name
Description
Range of
Setting
Primary
The acceleration time of primary speed, preset speed
Acceleration Time 4~7, and jog speed.
Primary
The deceleration time of primary speed, preset speed
Deceleration Time 4~7, and jog speed.
Acceleration Time
Acceleration time of preset speed 1.
of Preset Speed 1
Deceleration Time
Deceleration time of preset speed 1.
of Preset Speed 1
Acceleration Time
Acceleration time of preset speed 2.
of Preset Speed 2
0.0~
Deceleration Time
3200.0
Deceleration time of preset speed 2.
of Preset Speed 2
Acceleration Time
Acceleration time of preset speed 3.
of Preset Speed 3
Deceleration Time
Deceleration time of preset speed 3.
of Preset Speed 3
Secondary
Switch to secondary acceleration time by
Acceleration Time multi-function input terminal.
Secondary
Switch to secondary deceleration time by
Deceleration Time multi-function input terminal.
Set S-curve for Set S-curve to slow the acceleration and deceleration
0.0~5.0
Accel/Decel Time time at start and stop.
Limitation of
0: Output voltage of V/F pattern is not limited.
0, 1
Output Voltage 1: Output voltage of V/F pattern is limited.
Unit
Default
0.1
sec
(Note5)
0.1
sec
─
15.0
0.0
0
50.0
F_031
Maximum Output
Maximum output frequency of drive.
Frequency
0.1~400.0 0.1Hz
(Note1)
60.0
(Note2)
F_032
Starting
Frequency
F_033
Starting Voltage
Starting frequency of drive’s output.
0.1~10.0 0.1Hz
The voltage corresponds to the output starting
frequency.
0.1~50.0
0.5
8.0
0.1V
0.1~100.0
(Note3)
12.0
(Note4)
50.0
F_034
Base Frequency
The frequency corresponds to the base voltage in
V/F pattern.
0.1~400.0 0.1Hz
(Note1)
60.0
(Note2)
F_035
F_036
F_037
F_038
Base Voltage
The voltage corresponds to the base frequency in
V/F pattern.
V/F Frequency 1 Frequency at the first point of V/F pattern.
V/F Voltage 1
Voltage at the first point of V/F pattern.
V/F Frequency 2 Frequency at the second point of V/F pattern.
F_039
V/F Voltage 2
F_040
Vin Gain
Voltage at the second point of V/F pattern.
Analog input “Vin” gain ratio adjustment.
F_041
Vin Bias
Analog input “Vin” bias ratio adjustment.
220.0
0.1~255.0
0.1V
0.1~510.0
(Note3)
380.0
(Note4)
0.0~399.9 0.1Hz
0.0~255.0
0.1V
0.0~510.0
0.0
0.0~399.9 0.1Hz
0.0
0.0~255.0
0.1V
0.0~510.0
0.00~2.00 0.01
1.00
-1.00~
1.00
0.0
0.0
0.01
0.00
F_042
Frequency Upper The upper limit of output frequency=
Limit
F_031(Maximum Output Frequency )*F_042
0.00~1.00 0.01
1.00
F_043
Frequency Lower The lower limit of output frequency= F_031(Maximum
0.00~1.00 0.01
Limit
Output Frequency )*F_043
0.00
9
Func.
F_044
F_045
F_046
F_047
F_048
F_049
F_050
F_051
F_052
F_053
F_054
F_055
F_056
F_057
Name
Description
0: Output frequency
Analog Output
1: Frequency command
Signal Selection 2: Output current
(FM+)
3: “Vin” analog input signal.
Analog Output
Gain(FM+)
4: “Iin” analog input
signal.
5: DC bus voltage.
6. Output voltage.
Analog output gain ratioadjustment.
0: Disable
1: Overload protection for dependent cooling fan type
Motor Overload
motor:Enabled(OL)
Protection (OL)
2: Overload protection for independentcooling fan
type motor: Enabled(OL)
Filter Setting of Filter the analog input signal when the frequency
Analog Input command is controlled by analog input terminal.
Signal
(F_002=0).
Motor Rated
Current
Set the value according to the motor rated current.
Motor No-Load Current setting according to the motor’s no-load
Current
condition.
According to the load condition, set the motor slip
Motor Slip
compensation for motor running at constant speed.
Compensation
(0.0: off)
Range of
Setting
Unit
Default
0~6
─
0
0.00~2.00 0.01
0~2
─
0~255
─
10%~150%
of drive
rated
current
0.1A
0~motor
rated
current
0.1A
-9.9~10.0 0.1Hz
Number of Motor
Determinate the RPM display value of monitor mode. 2~10
Poles
=0:
Multi-function
UP/DOWN frequency
±1: Jog command
Input Terminal command enter key
±2: Secondary
(X1)
accel/decel time
command
=0:
Multi-function
±3: Multi-speed level 1
DC braking enable
command
Input Terminal (at stop)
±4: Multi-speed level 2
(X2)
command
=0:
±5: Multi-speed level 3
Multi-function
Current limit enable
command
Input Terminal
±6: Reset command
(X3)
±7: External fault
command(thr)
=0:
±8: Interruption of output
Selection of primary or
command(bb)
secondary frequency
-16~ +16
Multi-function
command
±9: Coast to stop
(Note 7)
Input Terminal
(ON:
secondary
frequency
command(Fr)
(X4)
command)
±10: Speed tracing from
the
maximumfrequency
=0:
Stop command with 3-wire ±11: Speed tracing from
Multi-function
the setting
start/stop circuit
frequency
Input Terminal (N.O; contact a)
±12:
Holding command
(X5)
±13: UP command
±14: DOWN command
=0:
Stop command with 3-wire ±15: Clear UP/DOWN
Multi-function
frequencycommand
start/stop circuit
Input Terminal (N.C; contact b)
±16: Analog input source
(X6)
selection
10
2P
1.00
1
20
According
to the
rated
current of
motor
1/3 motor
rated
current
0.0
4P
3
4
1
─
2
7
6
Func.
F_058
F_059
F_060
F_061
F_062
F_063
F_064
F_065
F_066
F_067
F_068
F_069
F_070
F_071
F_072
F_073
F_074
Name
Description
Range of
Setting
0: Disable
Multi-function
Output Terminal ±1: Operation command detection
±2: Constant speed detection
(Y1)
±3: Zero speed detection
±4: Frequency detection
Multi-function
Output Terminal ±5: Overload detection(OLO)
-11 ~+11
±6: Stall prevention detection
(Note 7)
(Y2)
±7: Low voltage detection(LE)
±8: Braking detection
Multi-function
±9: Restart after instantaneous power failure
detection
Output Terminal
±10: Restart after error condition detection
(Ta1,Tb1)
±11: Error detection
Constant Speed
Set the bandwidth of constant speed detection range. 0.0~10.0
Detection Range
Frequency
Set the bandwidth of frequency detection range.
0.0~10.0
Detection Range
Frequency
Set the frequency detection level of multi-function
0.0~400.0
Detection Level output terminal.
Automatic Torque
According to the load condition, adjust the output
Compensation
0.0~25.5
voltage of the V/F pattern. (0.0: off)
Range
System Overload 0: Disable
0,1
Detection (OLO) 1: Enable
System Overload 0: Detection during constant speedonly
0,1
DetectingSelection 1: Detection during operation only
0: Drive keeps operation when the overload is
Output Setting
detected
after System
0,1
1: Drive trips to protection when the overload
Overload
isdetected
30%~200%
When the output current of drive is larger than the
System Overload
of drive
levelwith the duration of F_069, the drive will trip to
rated
Detection Level
protection.
current
When the output current of drive is larger than the
System Overload
level (F_068 * drive’s rated current) with the duration, 0.1~10.0
Detection Time
the drive will trip to protection.
30%~200%
Stall Prevention
If stall is occurred during acceleration, the motor
of drive
Level at
rated
keeps running at constant speed. (200%: off)
Acceleration
current
30%~200%
Stall Prevention While the stall is occurred during constant speed
of drive
Level at Constant running condition, the prevention of stall is to
rated
Speed
decrease the speed of motor.(200%: off)
current
Acceleration Time
Setting after Stall Set the acceleration time after stall prevention under
0.1~
Prevention under the constant speed.
3200.0
Constant Speed
Deceleration Time
Setting for Stall Set the deceleration time at the stallprevention under 0.1~
Prevention under the constant speed.
3200.0
Constant Speed
Stall Prevention 0: Disable
Setting at
0, 1
Deceleration 1: Enable
F_075 DC Braking Level Set the current level of DC braking.
11
0~150%
of drive
rated
current
Unit
Default
3
─
2
11
0.1Hz
2.0
0.1Hz
2.0
0.1Hz
0.0
0.1
1.0
─
0
─
0
─
0
1%
160
0.1
sec
0.1
1%
170
1%
160
0.1
sec
(Note5)
0.1
sec
(Note5)
─
1
1%
50
15.0
15.0
Func.
Name
Description
Time of DC
F_076
Set the time for DC braking after drive stopped.
Braking after Stop
Time of DC
F_077 Braking before Set the time for DC braking before drive started.
Start
0: Drive cannot be restarted
Operation
1: Drive can be restarted
Selection at
2: Ramp to stop
F_078
Instantane- ous 3: Drive will re-accelerate again during ramp to stop
Power Failure
interval, when the power is restored.
F_079
F_080
F_081
F_082
F_083
F_084
Voltage Level of
Ramp to Stop by Set the voltage of power source for ramp to stop.
Power Failure
When the auto-restart times of error conditions
Auto-restart Times
(OC,OE,GF only) reach the setting value, the drive
Setting of Error
must be restarted manually.
Trip
0: disable
Switching
The setting value is higher and the motor noise is
Frequency
lower.
0: Ramp to stop
1: Coast to stop
Stop Mode
2: Coast to stop+ DC braking
Reverse
0: Reverse rotation allowed.
Prohibition
1: Reverse rotation NOT allowed.
Jump Frequency 1 Avoid mechanical resonance point 1.
Range of
Setting
Unit
Default
0.0~20.0
0.1
sec
0.5
0.0~20.0
0.1
sec
0.0
0~3
─
0
150.0~
192.0
300.0~
384.0
0.1V
0~16
1
0~6
─
0~2
─
0
0, 1
─
0
175.0
(Note3)
320.0
(Note4)
0
1
(Note6)
0.0~400.0 0.1Hz
0.0
F_085 Jump Frequency 2 Avoid mechanical resonance point 2.
0.0~400.0 0.1Hz
0.0
F_086 Jump Frequency 3 Avoid mechanical resonance point 3.
0.0~400.0 0.1Hz
0.0
0.0~25.5 0.1Hz
0.0
F_087
Jump Frequency
Set the range of the jump frequency 1, 2, 3.
Range
When the current is higher than the “speed
The Current Level
F_088 of Speed Tracing tracingcurrent level”, the output frequency will trace
downward.
0~200%
of drive
rated
current
1%
150
F_089
Delay Time before
Speed Tracing Set the output delay time before the speed tracing.
0.1~5.0
0.1
sec
0.5
F_090
The V/F Pattern of Set the percentage of V/F output voltage at the speed
0~100%
Speed Tracing tracing.
F_091
Display the latest 5 error records.
0: Parameters are changeable. Maximum frequency
cannot exceed 120.0Hz.
1: Parameters are locked. Maximum frequency
Parameter Setting cannot exceed 120.0Hz.
F_092
2: Parameters are changeable. Maximum frequency
Lock
can exceed 120.0Hz.
3: Parameters are locked. Maximum frequency can
exceed 120.0Hz.
Automatic Voltage 0: Disable
F_093 Regulation (AVR)
1: Enable
0: Disable
Drive Overload 1: Thermal protection
F_094
2: Current limit overload protection
(OL1)
3: Both 1 and 2 enable
F_095
Error Record
Power Source
The value of setting according to the actual power
source.
12
1%
100
─
─
─
0~3
─
0
0,1
─
1
0~3
─
3
190.0~
240.0
340.0~
480.0
0.1V
220.0
(Note3)
380.0
(Note4)
Func.
Name
Description
The drive accelerates to the holding frequency and
F_096 Holding Frequency
running at constant speed.
Holding
Time
The drive runs at holding frequency by constant
F_097
Interval
speed and running the time interval.
Range of
Setting
Unit
0.0~400.0 0.1Hz
Default
0.5
0.0~25.5
0.1
sec
0.0
F_098
Grounding Fault 0: Disable
Protection (GF) 1: Enable(GF)
0, 1
─
1
F_099
External Indicator Select the monitor mode of external indicator 1
1
0: Disable
0~8
─
1
F_100
External Indicator Select the monitor mode of external indicator 2
2
0: Disable
0~8
─
2
F_101
External Indicator Select the monitor mode of external indicator 3
3
0: Disable
0~8
─
3
0~4
─
0
0.1Hz
3.0
0.1
sec
(Note5)
0.1
sec
(Note5)
0.1Hz
0.0
0.01
Hz
0.00
1ms
10
─
1
─
20
─
17
─
8
─
5
─
3
─
1
─
0
F_102
F_103
F_104
F_105
F_106
F_107
F_108
F_110
F_111
F_112
F_113
F_114
F_115
F_116
F_117
V/F Pattern
Selection
0:Linear.
1: Energy-saving mode (auto-adjust V/F pattern
according to the load condition).
2: Square
curve.
th
3: 1.7th power curve.
4: 1.5 power curve.
Subtracted
When the power failure, drive will reduce the
Frequency of frequency level before ramp to stop.
0.0~20.0
Deceleration at F_078 Operation Selection at Instantaneous Power
Power Failure Failure =2 or 3
Deceleration Time
Set a deceleration time down to the turning frequency 0.0~
1 of Ramp to Stop
set in F_106.
3200.0
by Power Failure
Deceleration Time
Set a deceleration slope below the frequency set in
0.0~
2 of Ramp to Stop
F_106
3200.0
by Power Failure
Set the turning frequency level of ramp to stopwhen
Turning Frequency
the deceleration time is switched from F_104 setting 0.0~400.0
of Ramp to Stop
value to F_105setting value.
When the noise of analog input signal is
Analog Frequency large,appropriately increase the dead band to
0.00~2.55
Dead Band
stabilize the frequency command. But adjusting this
function will reduce the tuning linearity of input signal.
Digital Input
When the pulse width of digital signal is lower than
5~16
Response Time setting time, the signal disabled.
ADJ4 Function Set the function of ADJ4switch of KP-202 keypad.
0~49
Selection
ADJ5 Function Set the function of ADJ5switch of KP-202 keypad.
0~49
Selection
ADJ6 Function Set the function of ADJ6switch of KP-202 keypad.
0~49
Selection
DIP1 Function Set the function of DIP1switch of KP-202 keypad.
0~15
Selection
DIP2 Function
Set the function of DIP2switch of KP-202 keypad.
0~15
Selection
DIP3 Function
Set the function of DIP3switch of KP-202 keypad.
0~15
Selection
DIP4 Function Set the function of DIP4switch of KP-202 keypad.
0~15
Selection
Pot Knob of
KP-202 keypad Set the function of pot knob of KP-202 keypad.
0~49
Function Selection
13
15.0
15.0
Func.
F_118
F_119
F_120
F_121
F_122
F_123
F_124
F_125
F_126
F_127
F_128
F_129
F_130
F_131
F_132
Name
Description
Range of
Setting
0: Clear the UP/DOWN frequency command when
UP/DOWN
power failure.
0, 1
Memory Selection 1: Save the UP/DOWN frequency command at F_121
when power failure.
0: 0.01Hz
UP/DOWN
1~8: x0.05Hz
Frequency
0~250
9: 0.5Hz
Resolution
10~250: x0.1Hz
1~5: Cntinuousaccel./decel. when the terminal is
UP/DOWN Trigger
activated with the duration (1 ~ 5 sec).
1~6
Mode
6: Edge trigger
UP/DOWN
0.00~
Frequency
Adjust UP/DOWN frequency by KP-201C keypad.
400.00
Adjustment
Secondary
0:Frequency command by analog signal via terminal.
Frequency
1: Frequency command by keypad.
0~2
CommandSelectio
2: Frequency command by UP/DOWN terminal.
n
0: Vin+Iin
1: Vin-Iin
Analog
2: Iin-Vin
0~3
InputSelection
3: Vin or Iin
(switch by multi-function input terminal X1 ~ X6).
0: Analog input gain.
Analog Input
1: Frequency command.
Selection
2: Current limit level.
0~3
(Vin)
3: Analog input (Vin) can adjust output voltage of V/F
pattern
0: Analog input gain.
Analog Input
1: Frequency command.
Selection
2: Current limit level.
0~3
(Iin)
3: Analog input (Iin) can adjust output voltage of V/F
pattern
Iin Range
0: 4~20mA (2~10V).
0,1
Selection
1: 0~20mA (0~10V).
Analog Input
The gain ratio of analog input terminal Iin.
0.00~2.00
Gain(Iin)
Analog Input
-1.00~
The bias ratio of analog input terminal Iin.
Bias(Iin)
1.00
0: Output frequency.
1: Frequency command.
Analog Output 2: Output current.
Signal Selection 3: Vin frequency command
0~6
(AM+)
4: Iin frequency command.
5: DC bus voltage
6: Output voltaga
Analog Output
AM+ analog output adjustment ratio.
0.00~2.00
Gain(AM+)
Multi-function
The way of settings are same as multi-function output -11~+11
Output Terminal
terminals setting.(F_058 ~ F_060)
(Note 7)
(Ta2/Tc2)
DC Braking
Active frequency level of DC braking at stop.
Frequencyat Stop
F_133 Current Limit Level
Monitor the setting value of current limit level
percentage.
14
Unit
Default
─
0
─
0
─
1
0.01
Hz
0.00
─
0
─
0
─
1
─
1
─
0
0.01
1.00
0.01
0.00
─
2
0.01
1.00
─
1
0.1~60.0 0.1Hz
─
─
0.5
─
Func.
Name
Description
Range of
Setting
Unit
Default
─
─
─
─
0
1
0
1
─
─
0
0: Disable
CLF: Clear fault records
dEF60: Restore the default value of drive for 60Hz.
dEF50: Restore the default value of drive for 50Hz.
F_134
Default Setting SAv: Save the setting value.
rES: Restore the setting value.
rd_EE: Read the parameters from drive to digital
keypad
Wr_EE: Write the parameters from digital keypad to
drive
1: Paramerter cannot be changed after F0.18 locked,
Parameter Display but it can display the setting value.
Selection of
F_135
0~1
Parameter Lock 2: Paramerter cannot be changed after F0.18 locked,
but it cannot display the setting value.
Parameter Lock
Setting the password of parameter lock.
F_136
0~9999
Password Setting
Parameter Lock
F_137
Decording the password of parameter lock.
0~9999
Decoding Setting
0: Disable
CLF: Clear fault records
dEF60: Restore the default value of drive for 60Hz.
F_154
dEF50: Restore the default value of drive for 50Hz.
Default Setting SAv: Save the setting value.
─
rES: Restore the setting value.
rd_EE: Read the parameters from drive to digital
keypad(KP-201C)
Wr_EE: Wr_EE: Write the parameters from digital
keypad(KP-201C) to drive
The color as
means the functions can be set during operation.
Note:
1. Default value of 50Hz.
2. Default value of 60Hz.
3. Specification of 200V series.
4. Specification of 400V series.
5. 0.5 ~ 5HP: 5sec
7.5 ~ 30HP: 15sec
40HP above: 30sec
6. RM5G series: When switching frequency setting exceeds 4, the drive must be de-rating or selecting
higher capacity.
RM5P series: When switching frequency setting exceeds 2, the drive must be de-rating or selecting
higher capacity.
7.+: Represents a contact (N.O)
-: Represents b contact (N.C)
15
Error Trip Messages of Drive
Display
Description
Display
(EEr)
Description
(OLO)
KEYPAD
KEYPAD
EEPROM error
Hz
V
A
System overload
Hz
(AdEr)
V
A
(thr)
KEYPAD
KEYPAD
A/D converter error
Hz
V
A
External fault
Hz
(SC)
V
A
(PAdF)
KEYPAD
Keypad interruption
during copy
KEYPAD
Fuse open
Hz
V
A
Hz
(LE1)
KEYPAD
Hz
V
V
A
(OH)
KEYPAD
Under voltage
during operation
A
Drive overheating
Hz
(OC)
V
A
(OL)
KEYPAD
KEYPAD
Drive over current
Hz
V
A
Motor overload
Hz
(GF)
V
A
(OL1)
KEYPAD
KEYPAD
Grounding fault
Hz
V
A
Drive overload
Hz
V
A
(OE)
KEYPAD
Over voltage
Hz
V
A
Warning Messages of Drive
Display
Description
Display
(LE)
Power source
under voltage
KEYPAD
Hz
V
Description
(PrEr)
A
KEYPAD
Software fault
Hz
V
A
(Err_00)
KEYPAD
(bb)
Drive output
interruption
KEYPAD
Hz
V
Hz
V
A
(Err_01)
KEYPAD
A
Hz
(Fr)
V
A
(dtF)
KEYPAD
KEYPAD
Direction command
error
Coast to stop
Hz
V
A
Hz
KEYPAD
V
V
A
(Wr_F)
(db)
Hz
Err_00: Keypad cable
trip.(beforeconnecting)
Err_01: Keypad cable
trip.(connected)
Over voltage at
stop
A
Different software
version inter-copy
KEYPAD
Hz
16
V
A