Tender specification/sample service specification Zemdrain® Classic controlled permeability formwork liner (CPF) on panel formwork Item Service Quantity Unit UP € TP € Shuttering of the wall surface area consisting of panel formwork and liner as addition to wall position _____ for one-time use 001 The concrete-side surface of the girder formwork must be prepared in a clean and oil-free manner without any release agent residues and must be covered immediately before placing with a CPF liner to be delivered in accordance with the manufacturer's specifications. CPF liner for improving the concrete in the cover zone by means of reducing the water/cement ratio for one-time use. The following values will be improved demonstrably by the liner: Carbonation resistance Frost/thaw resistance Surface tensile strength Surface hardness Reduction of the water penetration depth Reduction of the chloride penetration depth No release agent must be used. Selected liner: Zemdrain® Classic from Max Frank GmbH & Co.KG or equivalent. Offered fabricate: ____________________ (Alternative products must achieve the same improvement values at least, the values must be demonstrated.) Install the liner as follows: Tension and attach the liners in accordance with the manufacturer's specifications. All formwork joints must be sealed carefully according to the specifications of the liner manufacturer. The formwork must be covered at higher temperatures than during the concreting process. The lined formwork should be the final element of the formwork to be erected in order to keep the period till concreting as short as possible. The formwork around the components must be removed after ____ days. Max Frank GmbH & Co. KG - Mitterweg 1 405LV07/01-INT/GB-06/12 - 94339 Leiblfing - Germany - Phone +49 9427 189-0 - Fax +49 9427 1588 a i i a a a a a a a a a a a a a www. m a xf r a n k . c o m Option 1 The liner is to remain attached to the concrete component for another ____ days ( max ____ ) for protection purposes and is to be covered with PE film additionally. Option 2 The liner must be removed together with the formwork. The liners must be disposed of after having been removed, re-using the liners is expressly prohibited. Unit: m² Manufacturer: Max Frank GmbH & Co. KG, 94339 Leiblfing, Germany Max Frank GmbH & Co. KG - Mitterweg 1 405LV07/01-INT/GB-06/12 - 94339 Leiblfing - Germany - Phone +49 9427 189-0 - Fax +49 9427 1588 a i i a a a a a a a a a a a a a www. m a xf r a n k . c o m
© Copyright 2025 Paperzz