Copyright 2017 TALLEMENCO PTY LTD 1 About the Presenter River Murray to Mount Lofty Ranges – 420m lift Evaluating pump and pipeline performance with SA Water for 20 years. Testing Waikerie CIT PS 2017 Photos: R Welke Dry year, 90% water pumped from River Murray 4 major pumping systems Approx 130,000 kW $millions/annum pumping costs Tested every 2 years Over 1000 pump tests Copyright 2017 TALLEMENCO PTY LTD 2 About the Presenter Pump Testing/Commissioning MBO No 3 PS 1973 Eg, Murray Bridge – Onkaparinga Pumps 1973 3 Pumping Stations, 9 pumps, ≈ 43,000 kW TOTAL All pumps All 316SS Tested in dedicated pipework. Typically 90% pump efficiency Corrosion issues. Copyright 2017 TALLEMENCO PTY LTD Photo: R Welke 3 About the Presenter Friction testing M/W P/L Pipeline Friction testing Photos: R Welke From largest (1.8m) to smallest (80mm) pipeline, (“C” Values) Mannum - Adelaide No.3 PS Determine maintenance policy Chlorination/pigging/rodding Pumping economics Corroded cast iron pipe. Photo: R Welke Copyright 2017 TALLEMENCO PTY LTD 4 About the Presenter Defining moment, 2000 “There’s a wheel barrow in my Pipeline” 10 km of 450NB PVC Pumps reduced output Pipeline friction test, 2000 Willunga Basin Water Co Photos: R Welke Copyright 2017 TALLEMENCO PTY LTD 5 Combine “Hazen & Williams” and “Darcy Weisbach Friction factor” Graph of “Pipe Bore Roughness” to “C” value Pipeline Friction Reduction of 10% pipe efficiency (C=135) due to only 0.1mm of pipe wall roughness. 80NB to 200NB PVC Class 12 Hazen-Williams "C" Value 160.0 150.0 80NB 140.0 100NB 130.0 150NB 120.0 200NB 110.0 100.0 0 0.1 0.2 0.3 0.4 Bore Roughness - mm 0.5 This level of roughness cannot be seen with naked eye. Need to quadruple bore roughness for next 10% efficiency loss (C=120) Chart: R Welke Copyright 2017 TALLEMENCO PTY LTD 6 Hydroponic lettuce farm 3xPhotos: R Welke Pumping Energy Efficiency Audits identified > $503,000 annual elect savings (since 2012) As much energy efficiency losses in pipes (hydraulics) as in pumps Cabbage farm Pasture farm Photo: R Vardy Copyright 2017 TALLEMENCO PTY LTD 7 Tariff – locked in by energy companies OR use solar How is electric pumping costed ? $$/yr* = 2.73 x metre head x c/kWh x ML/yr motor ɳ x pump ɳ Motor efficiency fixed Pump efficiency Worn OR off-BEP Pump less water – a) scheduling b) Soil moisture monitoring Elevation Filter head loss Main line head loss Laterals head loss Layflat hose head loss Emitter head loss Residual head Testing pumps *Refer www.talle.biz/data.html Copyright 2017 TALLEMENCO PTY LTD 8 Where can energy be saved? Pump efficiency Hydraulic efficiency Typically < 50% Recoverable energy losses Excess Friction losses + excess residual Typically > 50% recoverable energy losses Motor efficiency Pump efficiency Excess residual head Total Pumped Head Emitters friction loss controllable by design and maintenance Friction Lift (fixed) Copyright 2017 TALLEMENCO PTY LTD Mains Submains Pipe ageing Pump suction Valves Filters 9 How are energy savings measured? Head Pump efficiency Flow Power PUMP TEST (to AS/NZ 3598.2 Type 2 RPM Time: Cost: Hydraulic efficiency Friction Residual ½ day – 5 days $1,000 – $20,000 + Report HYDRAULIC TEST Time: Cost: 1 - 2 days $2500-$5000 + Report Risk depends on spend level How is the risk mitigated? Copyright 2017 TALLEMENCO PTY LTD 10 IPEEAT: 2015: Irrigation Pumping Energy Efficiency Assessment Tool Divides Irrigation into 8 distinct hydraulic models: CP/LM, Boom, Gun Knocker, Rotor, Drip, spray Flood Pipe & Riser Transfer Marine Each type has a unique hydraulic signature IPEEAT assesses overall pumping energy efficiency considering both pumping efficiency and hydraulic efficiency by comparing existing on farm performance with a similar type irrigation system built to best practice design in its class Copyright 2017 TALLEMENCO PTY LTD 11 IPEEATproLP: 2017 Irrigation Pumping Energy Efficiency Assessment Tool - Professional (Long Pipe) 1) Calculates Pump Efficiency a) Evaluates peak flow efficiency b) Evaluates annual demand efficiency 2) Calculates Hydraulic Efficiency (rising main) (Needs to be tested at Peak Irrigation Flow) 3) Calculates Carbon Emissions (tonnes/annum) Suited to long or short rising mains IPEEATproLP assesses both pumping efficiency and hydraulic efficiency by comparing existing on farm performance with a similar type pumping and pipeline system built to best practice design Copyright 2017 TALLEMENCO PTY LTD 12 Case Study 1: Lateral Move (2014) Emitter type – LM Defining moment, 2000 Residual Pressure above nozzle - kPa End nozzle Layflat Static Head, metres No filter Surface pump River/dam 140 ML /yr $12,800/yr 24c/kWh. ave 84m pumped head Belt drive Water level Copyright 2017 TALLEMENCO PTY LTD 13 Component. Pump effy Elevation m Residual head m Sum of head components $$/ML annual pumping cost Case Study 1: Lateral Move 2014 (IPEEAT) Measured 65% 6m 15m 84m 91 Expected 75% 6m 15m 48m 45 Major findings: mainline C=80 pump effy 65% Potential annual savings $6,818 Justifies pumping energy audit Copyright 2017 TALLEMENCO PTY LTD 14 Component. Pump effy Elevation m Residual head m Sum of head components $$/ML annual pumping cost Case Study 1: Lateral Move (IPEEATproLP) Measured 65% 6m 15m 84m 91 Expected 75% 6m 15m 48m 45 Major findings: mainline C=80 pump effy 65% Potential annual savings $5,515 ($56k amortised over 10 yrs) Justifies pipeline efficiency audit Copyright 2017 TALLEMENCO PTY LTD 15 Case Study 2: Flood 2011 Flood Pumps, Hay NSW Emitter type Flood Direct drive 5600 ML /yr $20,400/yr 10c/kWh. ave 5.3m pumped head Residual Pressure at centre line of outlet 0 kPa Surface motor No filter Static Head, metres River level “mean” Copyright 2017 TALLEMENCO PTY LTD 16 Component. Pump effy Elevation m Residual head m Sum of head components $$/ML annual pumping cost Case Study 2: Flood (IPEEATproLP) Measured 43% 5.1m 0m 5.4m 3.8 Expected 75% 5.1m 0m 5.4m 2.2 Major findings: pump effy 43% Potential annual savings $7,450 ($76k amortised over 10 yrs) Justifies pumping energy audit Copyright 2017 TALLEMENCO PTY LTD 17 Case Study 3: Knocker/Drip 2015 Residual Pressure end of R/M - kPa 260 Ha Mixed Irrigation, built 1960’s VFD’s No filter Static Head, 55 metres Surface pump Direct drive Water level 1388 ML /yr $160,000/yr 20.5c/kWh. ave 120m pumped head River Murray Copyright 2017 TALLEMENCO PTY LTD 18 Pump effy Elevation m Sum of head components $$/ML annual pumping cost Measured 65% 55m 80 84m 115 Expected 75% 55m 140 48m 58 C Value Component. Case Study 3: Knocker/drip 2015 (IPEEATproLP) Major findings: Mainline with C=80, pump effy 65% Total Potential annual savings $79,000 Justifies pumping energy audit ($25k/yr) Justifies pipeline efficiency audit ($54k/yr) Copyright 2017 TALLEMENCO PTY LTD 19 Case Study 4: Centre Pivot (IPEEATproLP audit only) 260 Ha Mixed Irrigation VFD’s Residual Pressure end of R/M - kPa Filter Static Head, 63 metres Surface pump Direct drive 1425 ML /yr $247,000/yr 18.2c/kWh. ave 108m pumped head Water level River Murray Copyright 2017 TALLEMENCO PTY LTD 20 Case Study 4: Centre Pivot Major findings: Pump effy annual 33% Pump effy peak flow 67% Mainline effy 102% (over-optimized) Potential annual savings $133k ($1.4mill amortised over 10 yrs) Justifies pumping energy audit Copyright 2017 TALLEMENCO PTY LTD 21 Why use IPEEATpro as an auditing tool? 1) Saving tax payers money in Govt Energy Efficiency programs 2) Expedites Energy Efficiency Programs 3) Optimising needs for pump specialist resources for site audits What future for pump testing? 1) Verifying IPEEATpro audits to AS/NZ 3598.2 Type 2 2) Specialist testing for very large water supply and irrigation pumps 3) Commissioning testing Copyright 2017 TALLEMENCO PTY LTD 22 Proudly Presented by .. Prepared by Tallemenco Pty Ltd ABN 92 105 345 506 PO Box 74, Greenacres, S.A., 5086Australia [email protected] www.talle.biz Mob 0414 492 256 Int’l Cell +61 414 492 256 "Pumping and Hydraulics' Solutions for Irrigation and Water Supply" Copyright 2017 TALLEMENCO PTY LTD 23 Who is Tallemenco? (SA based Company) • Rob Welke, MD, 49 yrs in water industry • including 25 yrs with SA Water, testing pumps and pipelines • Including 24 yrs in irrigation industry • Including 14 yrs practising as a pumping and hydraulic consultant (Tallemenco) • No Commercial ties (no affiliation with products or companies) • Member of American Society of Irrigation Consultants • Assoc. Diploma Mechanical Engineering • Certified Irrigation Agronomist • Certificate IV, Training and Assessment Copyright 2017 TALLEMENCO PTY LTD 24
© Copyright 2026 Paperzz