vertex - Eagle Lighting Australia

NE
TE
D
S
DE
D
SI
TE
G
M
AN
UFACTUR
ED
Glare Reducing Delta Prisms
Exposed T-bar
VERTEX
CRI 95+
W
Size
Sys. lm
lm
lm/W
CRI
Code
Suffix
1296
73
95+
EL-VER-2101- ___
Vertex | Exposed T-Bar, Delta Diffused, 4000K
18
600x300
1900
26
600x600
3350
2338
89
95+
EL-VER-2113- ___
27
1200x300
3300
2295
87
95+
EL-VER-2105- ___
30
1200x300
3600
2544
86
95+
EL-VER-2106- ___
30
1500x300
3750
2711
90
95+
EL-VER-2110- ___
34
1500x300
4200
3037
88
95+
EL-VER-2111- ___
Seismic Restraint Kit - 4 x gripple, 2 x 2m wire
EL-ACC-210-000
Wiring options
Suffix
Technical specifications
Standard
-000
Total Luminaire Efficacy Maximum < 90lm/W
DALI/STD terminal block
-200
MacAdam 3 SDCM
Maintained emergency
-800
System guarantee 5 years
DALI monitored emergency
-801
CRI 95+
Organic Response
-900
ETB VERTEX (940) 1200x300
Add one suffix code to the end of the luminaire part number to
indicate required function.
2.4m x 2.4m - 27W = 1.40W/m2/100 lux
LED
COI
IP
44/30
The combination of a V-shaped reflector
and Delta Prism Panel diffuser have been
used to mask the harsh micro points
of LEDs, creating a panel of perfectly
uniform luminance. The Vertex is COI
compliant, which assits in the detection
of cyanosis and other colour changes in
skin and body tissues.
The Vertex is positioned as the ideal
solution for office and general lighting
with an efficacy of up to 90lm/W
(1500mm x 300mm CRI95+ option)
The electronic driver is mounted to
the rear of the luminaire, in an isolated
thermal chamber. By separating the
driver, the LEDs within the luminaire
are kept at their lowest possible
operating temperature. This ensures
that the Vertex can offer the longest
possible lifetime of its LED components.
Lifetime data can be seen in the lumen
maintenance table opposite.
Options:
»
»
»
»
»
»
Plaster Recessed via Recessing Kit
Surface Mount via Mounting Kit
Emergency
Organic Response Enabled
Cyanosis
Seismic restraint kit
2.4m x 2.7m - 30W = 1.41W/m2/100 lux
Lumen Maintenance
W
Size
Spacing
ETB VERTEX (940) 1500x300
Lifetime
3.0m x 2.4m - 30W = 1.31W/m2/100 lux
3.0m x 2.7m - 34W = 1.31W/m2/100 lux
27W
1200x300
2.4m x 2.4m
L 90 B50 40,000hrs
30W
1200x300
2.4m x 2.7m
L 90 B50 35,000hrs
30W
1500x300
3.0m x 2.4m
L 90 B50 41,000hrs
34W
1500x300
3.0m x 2.7m
L 90 B50 36,000hrs
Nominal dimensions (mm)
E
fitting
ETB 600 x 300
ETB 600 x 600
ETB 1200 x 300
ETB 1500 x 300
AGi32
Spacing: Vertex 940, 1200 x 300
D
fitting dimensions
a
b
c
594
294
85
594
594
85
1194
294
85
1494
294
85
REVIT
Performance Summary
C
A
IES
2.4m x 2.4m - 27W = 328.75 lux
UGRmax: 17.6
2.4m x 2.7m - 30W = 324.64 lux
UGRmax: 18.8
Spacing: Vertex 940, 1500 x 300
B
luminous opening
d
e
560
200
560
400
1160
200
1460
200
weight
kg.
2.8
5.0
5.0
6.5
3.0m x 2.4m - 30W = 319.19 lux
UGRmax: 18.2
3.0m x 2.7m - 34W = 324.13 lux
UGRmax: 18.7
Design parameters
Maintenance: 0.8
Reflectance: 70/50/20
Ceiling height: 2.7m
Working plane: 0.72m
NE
TE
D
S
DE
D
SI
TE
G
M
AN
UFACTUR
ED
Glare Reducing Delta Prisms
Exposed T-bar
VERTEX
CRI 80+
W
Size
Sys. lm
lm
lm/W
CRI
Code
Suffix
1311
98
80+
EL-VER-2100- ___
LED
IP
44/30
Vertex | Exposed T-Bar, Delta Diffused, 4000K
13
600x300
1750
21
600x600
3100
2363
114
80+
EL-VER-2112- ___
21
1200x300
3100
2301
110
80+
EL-VER-2102- ___
25
1200x300
3500
2667
109
80+
EL-VER-2103- ___
25
1500x300
3850
2904
115
80+
EL-VER-2108- ___
28
1500x300
4100
3094
112
80+
EL-VER-2109- ___
Seismic Restraint Kit - 4 x gripple, 2 x 2m wire
EL-ACC-210-000
The combination of a V-shaped reflector
and Delta Prism Panel diffuser have been
used to mask the harsh micro points
of LEDs, creating a panel of perfectly
uniform luminance.
The Vertex is positioned as the ideal
solution for office and general lighting
with an efficacy of up to 115lm/W
(1500mm x 300mm CRI80 option)
The electronic driver is mounted to
the rear of the luminaire, in an isolated
thermal chamber. By separating the
driver, the LEDs within the luminaire
are kept at their lowest possible
operating temperature. This ensures
that the Vertex can offer the longest
possible lifetime of its LED components.
Lifetime data can be seen in the lumen
maintenance table opposite.
Options:
Wiring options
Suffix
Technical specifications
Standard
-000
Total Luminaire Efficacy Maximum < 115lm/W
DALI/STD terminal block
-200
MacAdam 3 SDCM
Maintained emergency
-800
System guarantee 5 years
DALI monitored emergency
-801
CRI 80+
Organic Response
-900
»
»
»
»
»
Plaster Recessed via Recessing Kit
Surface Mount via Mounting Kit
Emergency
Organic Response Enabled
Seismic restraint kit
IES
REVIT
AGi32
ETB VERTEX (840) 1200x300
Add one suffix code to the end of the luminaire part number to
indicate required function.
2.4m x 2.4m - 21W = 1.10W/m2/100 lux
2.4m x 2.7m - 25W = 1.10W/m2/100 lux
Lumen Maintenance
W
Size
Spacing
ETB VERTEX (840) 1500x300
Lifetime
3.0m x 2.4m - 25W = 1.03W/m2/100 lux
3.0m x 2.7m - 28W = 1.03W/m2/100 lux
21W
1200x300
2.4m x 2.4m
L 90 B50 64,000hrs
25W
1200x300
2.4m x 2.7m
L 90 B50 57,000hrs
25W
1500x300
3.0m x 2.4m
L 90 B50 64,000hrs
28W
1500x300
3.0m x 2.7m
L 90 B50 59,000hrs
Nominal dimensions (mm)
Performance Summary
Spacing: Vertex 840, 1200 x 300
C
D
E
A
fitting
ETB 600 x 300
ETB 600 x 600
ETB 1200 x 300
ETB 1500 x 300
fitting dimensions
a
b
c
594
294
85
594
594
85
1194
294
85
1494
294
85
2.4m x 2.4m - 21W = 329.70 lux
UGRmax: 17.8
2.4m x 2.7m - 25W = 342.36 lux
UGRmax: 18.5
Spacing: Vertex 840, 1500 x 300
B
luminous opening
d
e
560
200
560
400
1160
200
1460
200
weight
kg.
2.8
5.0
5.0
6.5
3.0m x 2.4m - 25W = 342.05 lux
UGRmax: 18.6
3.0m x 2.7m - 28W = 330.44 lux
UGRmax: 18.6
Design parameters
Maintenance: 0.8
Reflectance: 70/50/20
Ceiling height: 2.7m
Working plane: 0.72m