Gas Turbine Governor Model Data Sheet Submit this form as a pdf attachment by e-mail to: [email protected] or submit by mail: using the address given on the IESO’s Web site (www.ieso.ca) All information submitted in this process will be used by the IESO solely in support of its obligations under the “Electricity Act, 1998”, the “Ontario Energy Board Act, 1998”, the “Market Rules” and associated policies, standards and procedures and its licence. All submitted information will be assigned the appropriate confidentiality level upon receipt. Terms and acronyms used in this Form that are italicized have the meanings ascribed thereto in Chapter 11 of the “Market Rules”. Gas Turbine Governor (GAST) SPEED PMECH GAST Speed Power Speed SPEED D urb t 1 ü R VMAX - Load Ref. + VAR(L) S Low Value Gate 1 ü ü ü ü 1 + T1s 1 ü ü ü ü 1 + T2s + S PMECH VMIN S + S KT + - 1 ü ü ü ü 1 + T3s + Load Limit IMO-FORM-1476 v.3.0 REV-15-02 Confidential Page 1 of 2 Market Participant Name Market Participant ID # This model is located at system bus # IBUS machine # I This model uses CONs starting with # J and STATEs starting with # K and VAR # L CONs # Description STATEs # Description J R (Speed Droop) K Fuel Valve J+1 T1 (>0) (Seconds) K+1 J+2 T2 (>0) (Seconds) K+2 Fuel Flow Exhaust Temperature J+3 J+5 T3 (>0) (Seconds) Ambient Temperature Load Limit, AT KT VAR J+6 VMAX L J+7 VMIN J+8 Dturb J+4 Value # Description Load Reference IBUS, 'GAST', I, R, T1, T2, T3, AT, KT, VMAX, VMIN, Dturb Page 2 of 2 Confidential IMO-FORM-1476 v.3.0 REV-15-02
© Copyright 2024 Paperzz